INSPECTION WORKSHEET 03122024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: CC-0013-2023 Case Module: Permit
Inspection Date: March 12, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Firestopping
Job Address: 78 MAIN ST
, Parcel Number:
Contact Type Company Name Name
Owner 78-80 Main Street LLC
Contractor Foothills Builders
Architect Rucinski Hall Architecture
Checklist Item
Status
Permit card visible from the road
Building Inspector notes
3/1/24 fire stopping at vertical penetrations verified at exterior walls and
partitions separating rental spaces only
- fire stopping at draft stopping at floor trusses verified
3/12/24 partial approval for fire stopping
- remainder of fire stopping at vertical penetrations at first floor verified.
PASS
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Fireproofing
Firestopping
PASS
Draft stopping 1000 sq. ft. floor trusses
for Residential or Commercial
Draft stopping 3000 sq. ft. floor trusses
for attics
PASS
Bath fans connected to exterior vent
Penetration sealed
PASS
Exterior wall outlets sealed
16 inch minimum insulation in cavity
Garage fire separation
House side is 1/2 inch or 5/8 inch Type X
Garage ceiling, with living space above,
5/8 inch Type X
Mark Smith