Loading...
INSPECTION WORKSHEET 02232024 (2) INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0108-2022 Case Module: Permit Inspection Date: February 23, 2024 Inspection Status: Reinspect Inspector: Charles Dyer Inspection Type: Residential Final Job Address: 211 ASSEMBLY POINT RD , Parcel Number: Contact Type Company Name Name Owner N/A Owner N/A Contractor Larmon House Movers Inc Architect AJA Architecture & Planning Checklist Item Status Building Inspector notes provide kitchen sink / provide temporary guard at deck / provide final electrical / provide garage doors / provide bedroom doors with hardware PASS 4 inch min building number address visible from road Chimney height, B vent, direct vent location PASS Chimney rain cap installed PASS Fresh air intake PASS Fresh air supply 3 feet from grade PASS 3 inch plumbing vent through roof, minimum 18 inches PASS Outside spigots have air gap PASS Roof complete PASS Exterior finish complete FAIL Platform at all exterior doors PASS Handrail required with 4 or more risers Guards at stairs, decks and patios 30 inches or more above grade FAIL Guard at stairwell at 34 inches or more FAIL Window guards req at less than 2' above floor and 6' above grade PASS Guard at deck and porches 36" or more in height FAIL Handrail termination at newell post or wall FAIL Interior and exterior handrails 34" to 38" high FAIL Wood deck 2 feet or more from grade diagonal bracing required provide diagonal bracing at 6x6 posts FAILN/O 4 or more Deck Joist Ledger Connections starting 24" from each end PASS Deck ledgers to be bolted per code PASS Grade away from foundation sloping 6 inches in the first 10 feet FAIL 6 inch clearance to sill plate from grade PASS Gas meter and or regulator shut off 12 inches min above grade propane N/O HVAC vent terminal 10 feet from lot line and openings PASS Dryer duct max length 35 feet or per manufacturer's instructions PASS Interior privacy doors and trim required provide doors and hardware FAIL Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight complete 2nd bath N/O Low flow toilet 1.3 gallon per flushing cycle at completed bath FAIL Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Heat detector required in attached garage PASS Attic access 22 inches x 30 inches minimum with 30 inch high clearance PASS Attic access insulation R-value must equal ceiling R- value PASS Attic access gasketed PASS Crawl space and knee wall access insulated and gasketed PASS Bathroom fans required, if no window PASS All plumbing fixtures complete FAIL Backflow preventors where required PASS Foundation insulation to basement floor PASS All Hot Water Systems R 3 on 3/4 inches or larger piping PASS Duct work sealed properly PASS Intake openings for HVAC PASS Furnace shut off within 30 ft. or within line of site PASS Propane tank proper setback from property line or structure PASS Furnace and hot water heater operating PASS Pressure relief valve, heat trap, water temp 110 degrees or less PASS Pressure relief valve down spout within 6 inches of floor PASS 1/2 inch Gypsum or House Wall and Gable PASS 5/8 inch Type X with living space above PASS 20 minute fire door and self-closing hardware PASS Seals on garage doors, esp. wood provide garage doors N/O Basement wall insulation R- value verified PASS Basement egress: 5 s.f. window w/sill or Bilco door PASS Jack posts in basement lagged at top and bottom PASS Garage floor pitched PASS Gas log in sealed or glass enclosure PASS Fin elect; energy saving light bulbs 90 percent FAIL Final survey plot plan provide final survey FAILN/O Arc fault breaker habitable spaces PASS Flex gas pipe bonding PASS As built septic system PASS Site plan or variance approval inspection FAIL Fuel Tanks above flood plain elevation PASS Ok to issue temporary certificate of occupancy FAIL Ok to issue certificate of occupancy FAIL Charles Dyer Code Enforcement Officer