Loading...
INSPECTION WORKSHEET 03152024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0672-2023 Case Module: Permit Inspection Date: March 15, 2024 Inspection Status: Failed Inspector: Mark Smith Inspection Type: Residential Final Job Address: , Parcel Number: Contact Type Company Name Name Contractor Crown Field Services Owner U.S. Bank Trust N.A., Trustee Checklist Item Status Building Inspector notes 2/20/24 The final inspection has failed for the following reasons. 1) The home has been winterized and there is no heat, electricity or water turned on. 2) The heat needs to be on in order to turn the water on. 3) The electricity needs to be on and a final inspection performed by a third party electrical inspector approved by the Town of Queensbury. Note: Please address these issues before scheduling a Final Inspection by the Town of Queensbury Building and Code Enforcement Department. 3/15/24 final inspections for single family dwelling not approved. - provide proof of final electrical inspection - install rockwool fire stopping at floor penetration for tub drain N/O 4 inch min building number address visible from road Chimney height, B vent, direct vent location Chimney rain cap installed Fresh air intake Fresh air supply 3 feet from grade 3 inch plumbing vent through roof, minimum 18 inches Outside spigots have air gap Roof complete Exterior finish complete Platform at all exterior doors PASS Handrail required with 4 or more risers Guards at stairs, decks and patios 30 inches or more above grade Guard at stairwell at 34 inches or more Guard at deck and porches 36" or more in height Handrail termination at newell post or wall Interior and exterior handrails 34" to 38" high 6 inch clearance to sill plate from grade PASS Gas meter and or regulator shut off 12 inches min above grade HVAC vent terminal 10 feet from lot line and openings Dryer duct max length 35 feet or per manufacturer's instructions Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight Low flow toilet 1.3 gallon per flushing cycle Safety glazing required within 5 feet of tub and shower Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required in bedrooms with gas appliances PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS All plumbing fixtures complete PASS All Hot Water Systems R 3 on 3/4 inches or larger piping PASS Duct work sealed properly PASS Intake openings for HVAC PASS Furnace shut off within 30 ft. or within line of site PASS Furnace and hot water heater operating Pressure relief valve, heat trap, water temp 110 degrees or less Pressure relief valve down spout within 6 inches of floor Jack posts in basement lagged at top and bottom Fin elect; energy saving light bulbs 90 percent Arc fault breaker habitable spaces Flex gas pipe bonding Ok to issue temporary certificate of occupancy Ok to issue certificate of occupancy Mark Smith Code Enforcement Officer