INSPECTION WORKSHEET 03152024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0672-2023 Case Module: Permit
Inspection Date: March 15, 2024 Inspection Status: Failed
Inspector: Mark Smith Inspection Type: Residential Final
Job Address:
, Parcel Number:
Contact Type Company Name Name
Contractor Crown Field Services
Owner U.S. Bank Trust N.A., Trustee
Checklist Item
Status
Building Inspector notes
2/20/24
The final inspection has failed for the following reasons.
1) The home has been winterized and there is no heat, electricity or water
turned on.
2) The heat needs to be on in order to turn the water on.
3) The electricity needs to be on and a final inspection performed by a
third party electrical inspector approved by the Town of Queensbury.
Note: Please address these issues before scheduling a Final Inspection
by the Town of Queensbury Building and Code Enforcement Department.
3/15/24 final inspections for single family dwelling not approved.
- provide proof of final electrical inspection
- install rockwool fire stopping at floor penetration for tub drain
N/O
4 inch min building number address
visible from road
Chimney height, B vent, direct vent
location
Chimney rain cap installed
Fresh air intake
Fresh air supply 3 feet from grade
3 inch plumbing vent through roof,
minimum 18 inches
Outside spigots have air gap
Roof complete
Exterior finish complete
Platform at all exterior doors
PASS
Handrail required with 4 or more risers
Guards at stairs, decks and patios 30
inches or more above grade
Guard at stairwell at 34 inches or more
Guard at deck and porches 36" or more
in height
Handrail termination at newell post or wall
Interior and exterior handrails 34" to 38"
high
6 inch clearance to sill plate from grade
PASS
Gas meter and or regulator shut off 12
inches min above grade
HVAC vent terminal 10 feet from lot line
and openings
Dryer duct max length 35 feet or per
manufacturer's instructions
Interior privacy doors and trim required
PASS
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
Low flow toilet 1.3 gallon per flushing
cycle
Safety glazing required within 5 feet of
tub and shower
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
PASS
Smoke Detectors are required on every
level and in every bedroom
PASS
Smoke Detectors are required outside
every bedroom area
PASS
Smoke Detectors have battery back up
PASS
Smoke detectors are interconnected
PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas
PASS
Carbon monoxide detectors are required
in bedrooms with gas appliances
PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace)
PASS
All plumbing fixtures complete
PASS
All Hot Water Systems R 3 on 3/4 inches
or larger piping
PASS
Duct work sealed properly
PASS
Intake openings for HVAC
PASS
Furnace shut off within 30 ft. or within line
of site
PASS
Furnace and hot water heater operating
Pressure relief valve, heat trap, water
temp 110 degrees or less
Pressure relief valve down spout within 6
inches of floor
Jack posts in basement lagged at top and
bottom
Fin elect; energy saving light bulbs 90
percent
Arc fault breaker habitable spaces
Flex gas pipe bonding
Ok to issue temporary certificate of
occupancy
Ok to issue certificate of occupancy
Mark Smith