ApplicationArea Variance [ZBA approved: November 15, 2019]
General Information
Tax Parcel ID Number: ____________________
Zoning District: ____________________
Detailed Description of Project [include current & proposed use]:
Location of Project: _______________________________________________________________
Applicant Name: Mailing Address
Home Phone City, State, Zip
Work Phone Cell Phone
E-Mail: FAX No.
Agent’s Name: Mailing Address
Home Phone City, State, Zip
Work Phone Cell Phone
E-mail FAX No.
Owner’s Name Mailing Address
Home Phone City, State, Zip
Work Phone Cell Phone
E-mail FAX No.
Page 1
Studio A Landscape Architecture+Engineering, DPC/
Jon Lapper, esq.
kcatellier@studioadpc.com
jcl@bpsrlaw.com
38 High Rock Ave, Suite 3 | PO 272 /
1 Washington Ave.
Saratoga Springs, NY 12866/
Glens Falls, NY 12801
Area Variance [ZBA approved: November 15, 2019]
Site Development Data
Area / Type Existing sq. ft. Proposed
Addition sq. ft.
Total sq. ft.
A. Building footprint
B. Detached Garage
C. Accessory Structure(s)
D. Paved, gravel or other hard surfaced area
E. Porches / Decks
F. Other
G. Total Non-Permeable [Add A-F]
H. Parcel Area [43,560 sq. ft. / acre]
I. Percentage of Impermeable Area of Site [I=G/H]
Setback Requirements
Area Required Existing Proposed
Front Yard [1]
Front Yard [2]
Shoreline
Side Yard [1]
Side Yard [2]
Rear Yard [1]
Rear Yard [2]
Travel Corridor
Height [maximum]
Permeability
Number of parking spaces
Page 2
Area Variance [ZBA approved: November 15, 2019]
Additional Project Information
1. Will the proposal require a Septic Variance from the Town Board of Health? _______________
2. If the parcel has previous approvals, list application number(s): _________________________
3. Does this project require coverage under the New York State Pollutant Discharge Elimination System (SPDES) Permit
Program? __ Yes / __ No
4. Estimated project duration: Start Date: __________ End Date: __________
5. Estimated total cost of project: _______________
6. Total area of land disturbance for project: _______________
Floor Area Ratio Worksheet
FLOOR AREA RATIO (FAR) -- The relationship of building size to lot size, derived by dividing the total building floor
area by the lot size in square feet, yielding a percentage.
Zoning District Symbol Floor Area Ratio [FAR]
Waterfront Residential WR 0.22
Commercial Moderate / Commercial
Intensive
CM / CI 0.3
A. The combined area of all square footage, as measure from exterior walls of all structures on the property, including all
floors of the structures, garages, basements and attics with more than five (5) feet of ceiling height and covered
porches. Building square footage does not include: Open deck, docks and that portion of covered docks extending
over water and one storage shed of one hundred twenty (120) square feet or less. Any additional sheds will be
included. (See “FLOOR AREA RATIO”).
B. Commercial or industrial: the total area in square feet as measured from the exterior of the outside walls of a building
or structure, and when applicable, the sum total of all floor areas of the principal and accessory buildings or structures
on the project site.
Parcel Area ___________________________ sq. ft.
Existing Floor Area ___________________________ sq. ft. [see above definition]
Proposed Additional Floor Area ___________________________ sq. ft.
Proposed Total Floor Area ___________________________ sq. ft.
Total Allowable Floor Area ___________________________ (Area x _____) [see above table]
Page 3
Area Variance [ZBA approved: November 15, 2019]
Compliance with Zoning Ordinance
Requesting relief from SECTION: ________________________________
Need relief from the requirement(s) listed below which can not be met by the project as proposed.
[Check all that apply]
The following questions reflect the criteria for granting this type of variance. Please complete them; use additional sheets if
needed.
1. Whether an undesirable change will be produced in the character of the neighborhood or a detriment to
nearby property will be created by the granting of this area variance?
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
2. Whether the benefit sought by the applicant can be achieved by some method, feasible for the applicant
to pursue, other than an area variance?
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
3. Whether the requested area variance is substantial?
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
4. Whether the proposed variance will have an adverse effect or impact on the physical or environmental
conditions in the neighborhood or district?
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
5. Whether the alleged difficulty was self-created?
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
Page 4
Area Variance [ZBA approved: November 15, 2019]
Section 179-14-030
Application materials and site plan drawing is to include sufficient information for the Board to review and provide a decision. The
applicant is to provide a site plan drawing(s) – a survey showing existing conditions, a proposed conditions map (see page 00 for
specific criteria) and include any other attachments that address A - D as applicable to the proposed project.
A. General Shown on Sheet #
1 Title, Name, Address of applicant & person responsible for preparation of drawing
2 Deed
3 North arrow, Tax Map ID, date prepared and scale [minimum: 1 inch = 40 feet ]
4 Boundaries of the property plotted to scale, zoning boundary
5 Principal structures, accessory structures with exterior dimensions
6 Site improvements incl. outdoor storage areas, driveways, parking areas, etc.: existing &
proposed
7 Setbacks for all structures and improvements: existing & proposed
8 Elevations and floor plans of all proposed and affected structures
B. Water & Sewer Shown on Sheet #
1 Project sewage disposal facilities, design details, construction details, flow rates, and number of
bedrooms proposed
2 Water supply [i.e. well] & septic on adjoining lots with separation distances to existing or
proposed on-site water supply and septic
3 Separation distances for proposed sewage disposal system to well and water bodies
4 Existing public or private water supply [well, lake, etc.]. Method of securing public or private
water, location, design and construction of water supply including daily water usage
5 Percolation test location and results
C. Parking / Permeable Areas Shown on Sheet #
1 Number of spaces required for project including calculations and justification: existing &
proposed
2 No. of existing parking spaces, number to be removed, number to maintain and type of surfacing
material [e.g., gravel, paved]
3 Provision for pedestrian and handicap access and parking: existing & proposed
4 Design details of ingress, egress, loading areas and cutting: existing & proposed
5 Location and character of green areas [existing and proposed], modification to green area, buffer
zone to remain undisturbed
6 Lighting, location and design of all existing and proposed outdoor lighting
D. Additional Site Development and Miscellaneous Shown on Sheet #
1 On-site & adjacent watercourses, streams, rivers, lake and wetlands
2 Utility / energy distribution system [gas, electric, solar, telephone]: existing & proposed
3 Location, design and construction details of all existing and proposed site improvements
including: drains, culverts, retaining walls, fences, fire & emergency zones and hydrants, etc.
4 Square footage of bldg. area proposed for office, manufacturing, retail sales or other commercial
activities: existing & proposed
5 Signage: Location, size, type, design and setback: existing & proposed
6 Waiver Request: provide letter with application requesting any waivers: please reference
specific items
7 Commercial / Industrial Development requires submission of Landscaping, Stormwater
Management, Grading & Lighting Plans
8 Identification of Federal, State or County permits required for the project together with a record
of application for all necessary permits
Page 5
lighting to be downcast fixtures,
specific fixtures, T.B.D.
Area Variance Pre-Submission Conference Form / Section 179-9-040
1. Applicant Name: __________________________________________________
2. Tax Map ID ________________Location:_______________________
3. Zoning Classification __________
4. Reason for Review: __________________________________________________________
5. Zoning Section #: ________________________
6. Pre-Submission Meeting Notes: Provided Outstanding; Please provide by
Deed ____ _____________
General Information complete ____ _____________
Site Development Data Complete ____ _____________
Setback Requirements Complete ____ _____________
Additional Project Information Complete ____ _____________
FAR addressed ____ _____________
Compliance with Zoning Ordinance ____ _____________
Checklist items addressed ____ _____________
Environmental Form completed ____ _____________
Signature Page completed ____ _____________
Staff Representative: ________________________________
Applicant / Agent: ________________________________ Date: ___________
Page 6
Geraldine Eberlein
227.17-1-25 12 Seelye Road North
WR 0.30 ac
Application for demolish existing home and guest to construct a single family residence, project work includes a replacement of the boulder wall along the
shore
179-3-040WR dimensions, maybe 147 driveway
X
X
X
X
X
X
NA
X
AV70-2007-dock setback
residential lighting, stormwater, zoning map
Laura Moore via email 12/15/2022
12/15/2022
The applicant proposes demolition of an existing home and guest cottage to construct a new home with a
footprint of 2,411 sq ft and a new floor area of 3,361 sq ft. The project includes associated site work for a
new permeable driveway, stormwater management, and shoreline landscaping. The project includes
installation of a new septic system on the adjoining property.The project requires site plan for new floor area
in a CEA and hard surfacing within50 ft of the shoreline. The project requires area variances for front yard
setback where 13.5 ft is proposed and 30 ft is required, shoreline setback where 68.77 ft is required and 60 ft
is proposed, Floor area relief where 25.6% is proposed and 22% is the maximum allowed and permeability
where 70.4% is required and 75% is required.
Items reviewed: site plan application, area variance application, site plans, floor plans, elevations, deed
Items to be updated or provided
1) page 2- height to be noted on the application, height information will be needed in regards to topography
2) page 4 - add AV70-2007 dock
3) page 6 and 7 - items to be addressed Letter G - residential lighting to be down cast fixtures, Letter J needs
to demonstrate a 25 year storm, M - zoning map
4) site plan drawings - the setbacks to the building needs to noted on the drawing to each of the property
lines and the shoreline, the setback from the permeable driveway area to the shoreline will need to be noted -
if it is less than 100 ft it will trigger a variance
5) survey will need to be stamped, easement also need to be noted for access on Seelye Road
6)confirmation of outdoor kitchen location to discuss with Craig
7) The project appear to have 4 maybe 5 variances is there a way to reduce the number of requests
Geraldine Eberlein
Kirsten Catellier for Studio A 11/10/2022
38 High Rock Ave, Suite 3 | P.O. Box 272 | Saratoga Springs, NY 12866 | 518.450.4030
PROPOSED SINGLE FAMILY RESIDENCE
Geraldine Eberlein
2 Essex Street
Malta, NY 12020
AREA VARIANCE APPLICATION – Responses to Criteria
1. Whether an undesirable change will be produced in the character of the neighborhood or
a detriment to nearby property will be created by the granting of this area variance?
Response 1: No, an undesirable change will not be produced in the character of the
neighborhood by the granting of this area variance. The existing guest house with a front
yard setback of 1 ft. is proposed to be removed, along with the existing residence, and is
proposed to be replaced with a single-family residence. The proposed location of the
single-family residence will improve sight lines for the existing residence to the north of
the property. Extensive landscaping is also proposed along the shoreline, which will
improve the visual impacts of the property from the lake. The proposed project is in
character with the other residences located in the neighborhood.
2. Whether the benefit sought by the applicant can be achieved by some method, feasible
for the applicant to pursue, other than an area variance?
Response 2: The proposed project can not be achieved by any means other than an area
variance. There is a shoreline setback of 68.77 ft. and a front yard setback of 30 ft. The
average width of the parcel is 126.8 ft. The setbacks have considerably reduced the
building envelope to a length of 28 ft. These setbacks have resulted in a small building
envelope that is difficult to fit a single-family residence with a garage within.
In addition, an infiltration device servicing the runoff generated by the proposed
driveway is required. A 100 ft. shoreline setback creates a small area of the parcel in
which an infiltration device can be located. Though, due to the shallow seasonal high
groundwater table and the site topography, it is not feasible to capture and convey the
runoff to an infiltration device while maintaining a vertical separation of 2 ft. from the
groundwater table.
3. Whether the requested area variance is substantial?
Response 3: Yes, the requested area variances and FAR are substantial, though, the lot is
smaller than current zoning standards for lot size. Considering the smaller lot area, only a
small area of impervious surfaces can be permitted under town code. In order to lessen
the impact of impervious surfaces, permeable pavers are being used wherever feasible.
The requested lot permeability is 4.6% below the minimum allowable permeability. In
addition, the FAR is also negatively impacted by the small lot area. The requested FAR is
3.5% over the allowable FAR.
The proposed front yard setback of 13.5 ft. is an improvement of the existing front yard
setback of 1 ft. A variance of 16.5 ft, or 55% of the required front yard setback is
requested. The building conforms to the minimum shoreline setback of 50 ft. Though, the
shoreline setback is increased to 68.77 ft. due to the average of shoreline setback of the
neighboring lots. A variance of 14.77 ft., or 21.5% of the shoreline setback is requested.
The required shoreline setback for infiltration practices servicing areas subject to vehicle
traffic is 100 ft. A variance of 29.5 ft, or 29.5% of the shoreline setback is requested.
4. Whether the proposed variance will have an adverse effect or impact on the physical or
environmental conditions in the neighborhood or district?
Response 4: No, the proposed variances will not have an adverse effect on the
neighborhood or district. The project will result in a positive change overall. An existing
guest house located 1 ft. off of the property line is being removed, which will improve the
front and side yard setbacks, as well as improve site lines for the adjacent property to the
south. Stormwater management practices are also proposed to accommodate runoff
generated by the increase in impervious surfaces on site. No stormwater management
currently exists on site. Shoreline buffering, which does not currently exist, is proposed as
well to protect the quality of Lake George. Additionally, the existing rip-rap along the
shoreline is proposed to be replaced with a boulder revetment above the mean high
water line which will stabilize the shoreline. The proposed wastewater treatment system
meets all NYSDOH and Town of Queensbury Requirements.
Additionally, the proposed permeable paver driveway will not create an adverse effect on
the environmental conditions. The NYSDEC recommends using permeable pavers to treat
runoff generated by low traffic roads. The Stormwater Design Manual states that one of
the most notable benefits of utilizing permeable pavers is the effective pollutant
treatment for solids, metal, nutrients, and hydrocarbons. The EPA has analyzed the
pollutant removal performance of permeable paver technologies and has estimated high
removal percentages for sediments and nutrients. The permeable paver drive will be the
most effective way to treat the runoff generated by the proposed driveway, while
mitigating any adverse effects on the water quality of Lake George that may typically be
created by encroaching on the required 100 ft. setback.
5. Whether the alleged difficulty was self-created?
Response 5: Yes, the alleged difficulty is self-created by the applicant’s desire to improve
the current lot conditions.