Loading...
Zemanek Full Sumbmission SPR1 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 TOWN OF QUEENSBURY Site Plan Review Application Review Process: 1. Required Pre-submission meeting with staff to determine general completeness to be held no later than 1 week prior to deadline day.Call (518) 761-8265 or (518) 761-8220 for an appointment. 2. Submittal of complete application: 1 original and 14 copies of the application package by monthly deadline. 3. Determination of application completeness. All necessary information must be provided and appropriate fee(s) paid for consideration for placement on an agenda for that month. 4.Incomplete applications will not be considered for placement on any agenda until all missing information has been submitted. 5. Submittal to Warren County Planning, if applicable. 6. Planning Board meeting, generally the third & fourth Tuesday of each month. You will be advised in writing as to which meeting to attend. 7. Following the meeting you will be provided with a copy of the resolution stating the Board’s decision on your application. If your application was approved, the next likely step is a Building Permit. Final drawings must be provided for the next phase of review. If your application was denied, your project cannot proceed as submitted. DOCUMENTATION REQUIREMENTS (hard copy & electronic): Please submit 1 original & 14 copies of the completed application package to include: Completed Application pages 2-9, signed & dated Pre-Submission Meeting Notes:signed by staff Copy of Deed Checklist & Plot Plan Environmental Assessment Form for any non-residential project Fee:$100 (0 – 10,000 sq. ft.); $250 (10,001 – 30,000 sq. ft.); $500 (30,001 -100,000 sq. ft.); $1,000 (100,000+ sq. ft.) Staff & Contact Information: Craig Brown, Zoning Administrator craigb@queensbury.net Laura Moore, Land Use Planner lmoore@queensbury.net Sunny Sweet, Office Specialist – Planning sunnys@queensbury.net (518) 761-8220 Visit our website at www.queensbury.net for further information and forms 2 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 General Information Tax Parcel ID Number: ____________________ Zoning District: ____________________ Lot size: _____________________ Detailed Description of Project [includes current & proposed use]: __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ Location of project: ________________________________________________________________________________ Applicant Name: Address: Home Phone Cell: Work Phone Fax E-Mail: Agent’s Name:Address: Home Phone Cell: Work Phone Fax E-mail Owner’s Name Address Home Phone Cell Work Phone Fax E-mail 3 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 Site Development Data Area / Type Existing sq. ft. Proposed Addition sq. ft. Total sq. ft. A. Building footprint B. Detached Garage C. Accessory Structure(s) D. Paved, gravel or other hard surfaced area E. Porches / Decks F. Other G. Total Non-Permeable [Add A-F] H. Parcel Area [43,560 sq. ft. / acre] I. Percentage of Impermeable Area of Site [I=G/H] Setback Requirements Area Required Existing Proposed Front [1] Front [2] Shoreline Side Yard [1] Side Yard [2] Rear Yard [1] Rear Yard [2] Travel Corridor Height [max] Permeability No. of parking spaces Required Existing Proposed 2 Acres 0.05 Acres 0.45 Acres 150' 10' 86.58' 150' 0' 0' 150' 10' 87.06' Existing Sq. ft. Proposed Addition Sq. Ft. Total Sq. Ft. A. Main House 0 1008 1008 B. Shed (with lean to) 0 0 0 C. 0 1326 1326 D. Walkways, Patio, Landscape Steps 0 0 0 E. Total Non-Permeable (Sq. Ft.) [Add A-F] 0 2334 2334 F. Parcel Area [43,560 sqft/acre] 2,218 17,615 19,833 G. 2,218 17,615 19,833 H. 0.0% 11.8% 11.8% Required Existing Proposed 30' 0' 133.75' 50' 0' 54.76' 20' 0' 29.21' 20' 0' 29.23' 30' N/A N/A N/A N/A N/A 28' 0 27.6' 75% 100.0% 88.2% 202 Height [max] No. of parking spaces Minimum Lot Size: Parcel Information: LOT 2 Owner: Paul & Corina Zemanek Tax map I.D. Lot 2 #: 289.10-1-52.2 Zoning Designation: Waterfront Residential (WR) 0.05 Ac; 2,218 (sf) Proposed Area Lot 2: 0.455 Ac; 19,833 (sf) Site Requirements: LOT 2 Existing Area Lot 2: Area Minimum Lot Width: Minimum Road Frontage: Minimum Water Frontage: Site Development Data: LOT 2 Area / Type Travel Corridor LOT 2 Shoreline Side Yard [1] (East) Side Yard [2] (West) Front (Toward Glen Lake Road) Area Setback Requirements: LOT 2 Driveway Rear Yard Total Developable Parcel Area (F-G) Percentage of Impermeable Area of Site Permeability 4 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 Additional Project Information 1. Will the proposal require a Septic Variance from the Town Board of Health? _______________ 2. If the parcel has previous approvals, list application number(s): _________________________ 3. Does this project require coverage under the New York State Pollutant Discharge Elimination System (SPDES) Permit Program ? _______________ 4. Estimated project duration: Start Date __________ End Date __________ 5. Estimated total cost of project: _______________ 6. Total area of land disturbance for project: _______________ Floor Area Ratio Worksheet FLOOR AREA RATIO (FAR) -- The relationship of building size to lot size, derived by dividing the total building floor area by the lot size in square feet, yielding a percentage. Zoning District Symbol Floor Area Ratio [FAR] Waterfront Residential WR 0.22 Commercial Moderate/ Intensive CM/ CI 0.3 A. The combined area of all square footage, as measure from exterior walls of all structures on the property, including all floors of the structures, garages, basements and attics with more than five (5) feet of ceiling height and covered porches. Building square footage does not include: Open deck, docks and that portion of covered docks extending over water and one storage shed of one hundred twenty (120) square feet or less. Any additional sheds will be included. (See “FLOOR AREA RATIO”). B. Commercial or industrial: the total area in square feet as measured from the exterior of the outside walls of a building or structure, and when applicable, the sum total of all floor areas of the principal and accessory buildings or structures on the project site. A. Parcel Area ___________________________ sq. ft. B. Existing Floor Area ___________________________ sq. ft. [see above definition] C. Proposed Additional Floor Area ___________________________ sq. ft. D. Proposed Total Floor Area ___________________________ sq. ft. E. Total Allowable Floor Area ___________________________ (Area x _____) [see above table] *If D is larger than E. a variance or revisions to your plan may be needed. Consult with Staff. Zoning District Symbol Floor Area Ratio (FAR) WR 0.22 Existing Floor Area Ratio (FAR) Computations: Existing Property Size A. 2,218.00 sq. ft. B. 0.00 sq. ft. C. 487.96 sq. ft. D. Proposed Floor Area Ratio (FAR) Computations: Proposed Property Size A. 19,833.00 sq. ft. B. 2,568.00 sq. ft. C. 4363.26 sq. ft. D.Proposed Floor Area Ratio (FAR) - 3 Floors Total Allowable Floor Area 12.95% Total Allowable Floor Area Existing Floor Area Ratio (FAR) Floor Area Ratio Worksheet: LOT 2 Existing Floor Area Proposed Floor Area - 3 Floors Parcel Area Parcel Area Waterfront Residential (WR) 0.00% (LAKE SIDE) (ROAD SIDE) 25 ' - 7 3 4" 9' - 1 1 8" EXISTING GRADE AT TOP OF SLOPE EXISTING GRADE AT BOTTOM OF SLOPE 27 ' - 7 3 4" 9'-11 8" RETAINING WALLS AS NECESSARY 5 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 § 179-9-080 Requirements for Site Plan Approval. The Planning Board shall not approve a Site Plan unless it first determines that such site plan meets the following Standards. Please prepare responses to each of the following topics: STANDARDS A.The proposed project furthers or is consistent with the policies of the Town’s Comprehensive Plan. B.The proposed project complies with all other requirements of this Chapter, including the site plan review standards as set forth in Paragraph F of this section, the dimensional, bulk and density regulations of the zoning district in which it is proposed to be located (Article 3 and Table 1), the applicable requirements of all other Articles that apply. C.The site plan encourages pedestrian activity internally and, if practicable, to and from the site with pedestrian paths or sidewalks connected to adjacent areas. D.The site plan must conform to Chapter 136 Sewage and Sewage Disposal, Chapter 147 Stormwater Management Local Law, and other applicable local laws. E.The proposed use shall be in harmony with the general purpose or intent of this Chapter, specifically taking into account the location, character and size of the proposed use and the description and purpose of the district in which such use is proposed, the nature and intensity of the activities to be involved in or conducted in connection with the proposed use and the nature and rate of any increase in the burden on supporting public services and facilities which will follow the approval of the proposed use. F.The establishment, maintenance and operation of the proposed use will not create public hazards from traffic, traffic congestion or the parking of vehicles and/or equipment or be otherwise detrimental to the health, safety or general welfare of persons residing or working in the neighborhood or to the general welfare of the town. Traffic access and circulation, road intersections, road and driveway widths and traffic controls will be adequate. G.Off-street parking and l9oading facilities will be appropriately located and arranged and sufficient to meet traffic anticipated to be generated by the new use. The establishment of vehicle links between parking areas of adjacent properties are provided where feasible. This furthers the Town’s goal of reducing curb cuts and reducing congestion. A twenty-foot wide connection is required. If adjacent properties are either undeveloped or previously developed without having made provision for future linkage, then a future connection must be identified and provided for in the site plan under review for such future linkage when the time arises. The Planning Board may require proof that the applicant has made contact with adjacent property owners for purposes of coordinating linkages with adjacent properties. H.The project shall not have an undue adverse impact upon the natural, scenic, aesthetic, ecological, wildlife, historic, recreational or open space resources of the town or the Adirondack Park or upon the adequate provision of supporting facilities and services made necessary by the project, taking into account the commercial, industrial, residential, recreational or other benefits that might be derived from the project. In making the determination hereunder, the Planning Board shall consider those factors pertinent to the project contained in the development considerations set forth herein under § 179-9-080 of this Chapter, and in so doing, the Planning Board shall make a net overall evaluation of the project in relation to the development objectives and general guidelines set forth in § 179-9-080 of this Article. I.The provision for and arrangement of pedestrian traffic access and circulation, walkway structures, control of intersections with vehicular traffic and overall pedestrian convenience shall be safe and adequate for pedestrian movement. Pedestrian connections between adjacent sites shall be provided to encourage pedestrian use. J.Stormwater drainage facilities will prevent an increase of post development drainage flows as compared to pre-development drainage flows. Drainage of the site shall recharge ground water to the extent practical. Surface waters flowing off-site shall not degrade any streams or adversely affect drainage on adjacent properties or public roads. Facilities shall be in conformance with the drainage standards of Chapter 147 of the Town Code and the Town of Queensbury Subdivision Regulations where applicable. K.The water supply and sewage disposal facilities will be adequate and will meet all applicable and current requirements set forth by Department of Health regulations and Chapter 136 of the Town Code. L.The adequacy, type and arrangement of trees, shrubs and other suitable plantings, landscaping and screening shall effectively provide a visual and/or noise buffer between the applicants and adjoining lands, including the maximum retention of existing vegetation and maintenance, including replacement of dead or deceased plants. M.Fire lanes, emergency zones and fire hydrants will be adequate and meet the needs and requirements of emergency service providers. N.The design of structures, roadways and landscaping in areas susceptible to ponding, flooding and/or erosion will minimize or avoid such impacts to the maximum extent practicable. O.The site plan conforms to the design standards, landscaping standards and performance standards of this chapter. Stephen Traver, Chairman, and Planning Board Members February 2023 Re: Zemanek Residence, Elm Drive on Glen Lake Page 1 of 3 § 179-9-080 Requirements for Site Plan Approval. The Planning Board shall not approve a Site Plan unless it first determines that such site plan meets the following Standards. Please prepare responses to each of the following topics: Standards A. The proposed project furthers or is consistent with the policies of the Town’s Comprehensive Plan. Yes, one single family residence on a .455± acre parcel in the WR zone around Glen Lake is consistent with the current comprehensive plan and existing development around Glen Lake. B. The proposed project complies with all other requirements of this Chapter, including the site plan review standards as set forth in Paragraph F of this section, the dimensional, bulk, and density regulations of the zoning district in which it is proposed to be located (Article 3 and Table 1), the applicable requirements of all other Articles that apply. All applicable standards will be met except for minimum lot size, minimum lot width, minimum road frontage, minimum water frontage, stormwater within 100’ of shoreline and access to the lot, which is proposed by means of an existing driveway off Elm Drive (same owner). (Area variance required for nonconforming area standards.) C. The site plan encourages pedestrian activity internally and, if practicable, to and from the site with pedestrian paths or sidewalks connected to adjacent areas. Not applicable for private residential property. D. The site plan must conform to Chapter 136 Sewer and Sewage Disposal, Chapter 147 Stormwater Management Local Lay, and other applicable local laws. Sewage Disposal and Stormwater Maintenance Systems compliant with Chapters 136 & 147 are proposed. E. The proposed use shall be in harmony with the general purpose or intent of this Chapter, specifically taking into account the location, character and size of the proposed use and the description and purpose of the district in which such use is proposed, the nature and intensity of the activities to be involved in or conducted in connection with the proposed use and the nature and rate of any increase in the burden on supporting public services and facilities which will follow the approval of the proposed use. One single family residence is proposed on a .455± acre parcel in the WR zone. The project is being designed to be as inconspicuous and as least disruptive of the site as practical. No steep slopes are to be impacted, existing driveway to be used for access and no tree clearing is proposed. F. The establishment, maintenance and operation of the proposed use will not create public hazards from traffic, traffic congestion or the parking of vehicles Stephen Traver, Chairman, and Planning Board Members February 2023 Re: Zemanek Residence, Elm Drive on Glen Lake Page 2 of 3 and/or equipment or be otherwise detrimental to the health, safety or general welfare of persons residing or working in the neighborhood or to the general welfare of the town. Traffic access and circulation, road intersections, road and driveway widths, and traffic controls will be adequate. One new single family residence will be accessed by sharing an existing driveway; therefore, no undue traffic hazard will be introduced. G. Off-street parking and loading facilities will be appropriately located and arranged and sufficient to meet traffic anticipated to be generated by the new use. The establishment of vehicle links between parking areas of adjacent properties are provided where feasible. This furthers the Town’s goal of reducing curb cuts and reducing congestion. A twenty-foot wide connection is required. If adjacent properties area either undeveloped or previously developed without having made provision for future linking, then a future connection must be identified and provided for in the site plan under review for such future linking when the time arises. The Planning Board may require proof that the applicant has made contact with adjacent property owners for purposes of coordinating linkages with adjacent properties. Not applicable for private residential property. H. The project shall not have an undue adverse impact upon the natural, scenic, aesthetic, ecological, wildlife, historic, recreational or open space resources of the town or the Adirondack Park or upon the adequate provision of supporting facilities and service made necessary by the project, taking into account the commercial, industrial, residential, recreational or other benefits that might be derived from the project. In making the determination hereunder, the Planning Board shall consider those factors pertinent to the project contained in the development considerations set forth herein under § 179-9-080 of this chapter, and in so doing, the Planning Board shall made a net overall evaluation of the project in relation to the development objectives and general guidelines set forth in § 179-9-080 of this Article. Little to no adverse impact on natural resources on the site is expected, based on the following that have been incorporated into the project, positive impacts are expected: 1. An existing driveway will be shared for access to the site, thus minimizing new driveway construction. 2. No significant impact to steep slopes is necessary. 3. No tree clearing is required on the building site. 4. New stormwater management practices for both lots. I. The provisions for and arrangement of pedestrian traffic access and circulation, walkway structures, control of intersections with vehicular traffic and overall pedestrian convenience shall be safe and adequate for pedestrian movement. Pedestrian connections between adjacent sites shall be provided to encourage pedestrian use. Not applicable for private residential property. Stephen Traver, Chairman, and Planning Board Members February 2023 Re: Zemanek Residence, Elm Drive on Glen Lake Page 3 of 3 J. Stormwater drainage facilities will prevent an increase of post development drainage flows as compared to pre-development drainage flows. Drainage of the site shall recharge ground water to the extent practical. Surface waters flowing off-site shall not degrade any streams or adversely affect drainage on adjacent properties or public roads. Facilities shall be in conformance with the drainage standards of Chapter 147 of the Town Code and the Town of Queensbury Subdivision Regulations where applicable. Stormwater management is proposed for all impervious areas of both lots, including driveway, house, walkways, patios, etc. The system has been sized to mitigate the rate of runoff from a “25 year” storm event, consistent with Town standards. K. The water supply and sewage disposal facilities will be adequate and will meet all applicable and current requirements set forth by Department of Health Regulations and Chapter 136 of the Town Code. Both the Water Supply and Sewage Disposal systems will be adequate for the anticipated needs, and in conformance with Town and State standards. L. The adequacy, type and arrangement of trees, shrubs and other suitable plantings, landscaping and screening shall effectively provide a visual and/or noise buffer between the applicants and adjoining lands, including the maximum retention of existing vegetation and maintenance, including replacement of dead or deceased plants. Tree cover on the site will be left intact entirely and only minimal shrub removal to facilitate the construction of the new residence. Existing surrounding screening trees along property lines will provide excellent screening from all public vantage points. M. Fire lanes, emergency zones and fire hydrants will be adequate and meet the needs and requirements of emergency service providers. The driveway has been planned to facilitate emergency vehicle access, and the house will have a sprinkler system to aid in fire suppression and response. N. The design of structures, roadways and landscaping in areas susceptible to ponding, flooding and/or erosion will minimize or avoid such impacts to the maximum extent practicable. The house site is located such that it is not readily susceptible to flooding, and the driveway and landscaped areas have been designed to minimize flood risk. O. The site plan conforms to the design standards, landscaping standards and performance standards in this chapter. Site design follows Queensbury standards. F:\DataFile\2021 Proj\Resid\21-008 Brown SP\Work Docs\21008 22xxxx SP\Srce Files\21008 220421 SP Quest.doc 6 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 § 179-9-050 Checklist-Application for Site Plan Review. Application materials and site plan shall include sufficient information for the Board to review and provide a decision. The applicant is to provide a site plan drawing and all attachments that address items A-V. The applicant may request a waiver from A-V and is to provide reasons for waiver(s) requested. Please label information to be submitted. REQUIREMENTS Sheet # A.A vicinity map drawn at the scale that shows the relationship of the proposal to existing community facilities which affect or serve it, such as roads, shopping areas, schools, etc. The map shall also show all properties, identify owners, subdivisions, streets and easements within 500 feet of the property. Such a sketch may be superimposed on a United States Geological Survey map of the area. B.The site plan shall be drawn at a scale of forty feet to the inch (1” = 40 feet) or such other scale as the Planning Board may deem appropriate, on standard 24” x 36” sheets, with continuation on 8 l/2 “x 11” sheets as necessary for written information. The information listed below shall be shown on the site plan and continuation sheets. C.Name of the project, boundaries, date, north arrow, and scale of the plan. D.Name and address of the owner of record, developer, and seal of the engineer, architect or landscape architect. If the applicant is not the record owner, a letter of authorization shall be required from the owner. E.The location and use of all existing and proposed structures within the property, including all dimensions of height and floor area, all exterior entrances, and all anticipated future additions and alterations. F.The location of all present and proposed public and private ways, off-street parking areas, driveways, outdoor storage areas, sidewalks, ramps, curbs, paths, landscaping, walls and fences. Location, type and screening details for all waste disposal containers shall also be shown. G.The location, height, intensity and bulb type (sodium, incandescent, etc.) of all external lighting fixtures. The direction of illumination and methods to eliminate glare onto adjoining properties must also be shown in compliance with § 179-6-020. H.The location, height, size, materials and design of all proposed signs. I.The location of all present and proposed utility systems including: 1. Sewage or septic system; 2. Water supply system; 3. Telephone, cable and electrical systems; and 4. Storm drainage system including existing and proposed drain lines, culverts, catch basins, headwalls, endwalls, hydrants, manholes and drainage swales. J.Plans to prevent the pollution of surface or groundwater, erosion of soil both during and after construction, excessive runoff and flooding of other properties, as applicable. A Stormwater Pollution Prevention Plan (SWPPP) for all land development activities (excluding agricultural activities) on the site that results in land disturbance of one acre or more. A SWPPP shall comply with the requirements of the DEC SPDES MS-4 General Permit and Chapter 147 of the Town of Queensbury Code. It shall be at the discretion of the Planning Board as to whether a SWPPP or an erosion and control plan shall be required for a site plan review project land disturbance of less than one acre. K.Existing and proposed topography at two-foot contour intervals, or such other contour interval as the Planning Board shall allow. All elevations shall refer to the nearest United States Coastal and Geodetic Bench Mark. If any portion of the parcel is within the 100-year floodplain, the area will be shown and base flood elevations given. Areas shall be indicated within the proposed site and within 50 feet of the proposed site where soil removal or filling is required, showing the approximate volume in cubic yards. L.A landscape plan showing all existing natural land features than may influence the design of the proposed use such as rock outcrops, stands of trees, single trees eight or more inches in diameter, forest cover and water sources and all proposed changes to these features, including sizes and types of plants. Water sources include ponds, lakes, wetlands and watercourses, aquifers, floodplains and drainage retention areas. M.Land Use District boundaries within 500 feet of the site’s perimeter shall be drawn and identified on the site plan, as well as any Overlay Districts that apply to the property. 7 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 REQUIREMENTS (CONTINUED)Sheet # N.Traffic flow patterns within the site, entrances and exits, loading and unloading areas, as well as curb cuts on the site and within 100 feet of the site. The Planning Board may, at its discretion, require a detailed traffic study for large developments or for those in heavy traffic areas, which shall include: 1. The projected number of motor vehicle trips to enter or leave the site, estimated for weekly and annual peak hour traffic levels; 2. The projected traffic flow pattern including vehicular movements at all major intersections likely to be affected by the proposed use of the site; 3. The impact of this traffic on levels of service on abutting public streets and at affected intersections. Existing and proposed weekly and annual peak hour traffic levels and road capacity levels shall also be given. O.For new construction or alterations to any structure, a table containing the following information shall be included: 1. Estimated area of structure to be used for particular purposes such as retain operation, office, Storage, etc.; 2. Estimated maximum number of employees; 3. Maximum seating capacity, where applicable; and 4. Number of parking spaces existing and required for the intended use. P.1. Floor Plans. 2. Elevations at a scale of one-quarter inch equals one foot (1/4” = 1 foot) for all exterior facades of the proposed structure(s) and/or alterations to or expansions of existing facades, showing design features and indicating the type and color of materials to be used. Q.Soil logs, water supply well and percolation test results, and storm water runoff calculations as needed to determine and mitigate project impacts. R.Plans for disposal of construction and demolition waste, either on-site or at an approved disposal facility. S.Plans for snow removal, including location(s) of on-site snow storage. T.An Environmental Assessment Form (“EAF”) as required by the SEQRA regulations, with Part 1 completed by the Applicant shall be submitted as part of the application. If the proposed project requires a special use permit and an EAF has been submitted in conjunction with a special use permit application, a duplicate EAF is not required for the site plan application. U.If an application is for a parcel or parcels on which more than one use is proposed, the applicant may submit a single application for all such uses, provided the proposed uses are accurately delineated on a site plan drawn pursuant to the requirements set forth above. The Planning Board may grant the application with respect to some proposed uses and not others. For purposes of reviewing an application (and for SEQRA compliance) all proposed uses on a single parcel or on contiguous parcels shall be considered together. V.A brief narrative statement on how the project proposed for review furthers or is consistent with the vision, goals and policies in the Town’s Comprehensive Plan. Town of Queensbury Site Plan Pre-Submission Conference Form / Section 179-9-040 1. Applicant Name: __________________________________________________ 2. Tax Map ID ________________ Location: _______________________ 3. Zoning Classification __________ 4. Reason for Review: __________________________________________________________ 5. Zoning Section #: ________________________ 6. Pre-Submission Meeting Notes: Provided Outstanding; Please provide by Deed ____ _____________ General Information complete ____ _____________ Site Development Data Complete ____ _____________ Setback Requirements Complete ____ _____________ Additional Project Information Complete ____ _____________ FAR addressed ____ _____________ Requirements for Site Plan-Standards ____ _____________ Checklist items addressed ____ _____________ Environmental Form completed ____ _____________ Signature Page completed ____ _____________ Staff Representative: ________________________________ Applicant / Agent: ________________________________ Date: ___________ Paul Zemanek Lot 2 rev2 289.10-1-52.2 Elm Drive adjacent to 10 Elm Drive WR Applicant proposes a new single family home of 1,400 sq ft footprint with a floor area of 4200 sq ft. The existing parcel is vacant and site work includes new septic, well, driveway access from the adjoining lot, and stormwater management. Along with a lot line adjustment from .05 ac to 0.45ac. 179-3-040 WR, 179-6-065 new floor area X X X X X X X NA X Height proposed 38 ft and 2 7/8 inches Laura Moore via email 01/19/2024 Aaron Robert via email 12/07/2023 01/19/2024 Applicant proposes a new single family home of 1,400 sq ft footprint with a floor area of 4,200 sq ft. The existing parcel is vacant and site work includes new septic, well, driveway access from the adjoining lot. The project work includes shoreline planting plan and stormwater management. The project parcel is associated with a lot line adjustment with the adjoining lot. Site Plan review for new floor area in a CEA. Area Variance for lot having no road frontage and access from adjoining lot_179-4-050, height relief where proposed is 38 ft and 27/8 inches where maximum height allowed is 28 ft _179-3-040 . Note since lot improvements include an increase in lot size, lot width, minimum water frontage variances are not triggered due to the increase to be more compliant. Items reviewed: revised area variance application for lots 289.10-1-52.1 & 289.10-1-52.2, site plan application for 289.10-1-52.2, site drawings, stamped survey Items to be updated or provided: 1) Shared water source will trigger Town Board variance - Town Board variances need to occur prior to site plan or zoning board project review. 2) page 6 and 7 -Item G Lighting --Change to indicate note on sheet 3 of 9 (C1)--indicates fixtures to be dark sky compliant. 3) side setbacks to be noted as 20 ft 8 IRF IRFSHED 10' Right of Way As Per Deed Reference B.484 P. 116, B.1104 P. P.242 1  ƒ       ( 218 . 9 3 ' 6    ƒ       ( 1 0 0 . 0 0 ' 6ƒ ( 50.00' 209 . 8 7 ' 6  ƒ       : 6ƒ : 17.71' Proposed Area 289.10-1-52.2 Proposed Area 5 0 . 0 0 ' 1    ƒ       : 1 0 0 . 1 7 ' 1    ƒ       : Doc k 2 n d S t o r y D e c k Con c r e t e W a l k Con c r e t e W a l k 2 S t o r y Woo d F r a m e H o u s e 10' W i d e R i g h t - O f - W a y F r o m G l e n L a k e R a o d t o G l e n L a k e a s Per 4 8 4 / 1 1 6 - 5 2 1 / 1 8 3 - 5 2 1 / 1 8 5 - 1 1 0 4 / 2 4 2 Sh e d Le a n T o She d Ti m b e r R e t a i n i n g W a l l Propane Tank Well Crushed Stone ParkingFlag Pole  “7R6KRUH  “7R6KRUH      “  $ O R Q J  6 K R U H      “  $ O R Q J  6 K R U H ( T i e L i n e ) ( T i e L i n e ) 289.10-1-52.1  “7R6KRUH Lands N/F of Harvey D. Wilson 2 St o r y Woo d F r a m e H o u s e CIRF IRF Square Fence Post Found B.R.F. Lands N/F of Zemanek Lands N/F of Miller Lands N/F of Gary G. Pinero Lands N/F of Betty Spadaro Asp h a l t D r i v e Deed Reference 1 Paul Zemanek & Sheryl Zemanek To Paul S. Zemanek III Dated: April 8, 2002 Book 1287 Page 54 Map References: 1 Map of Lands Proposed To be Conveyed By Ebert C. Hibbard To Glen Wilson Dated: June 21, 1967 Last Revised: March 21, 1978 By Coulter & McCormack Licensed Land Surveyors 2 Map of Lands of Glen Wilson Dated: March 22, 1978 Last Revised: October 25, 1978 By Coulter & McCormack Licensed Land Surveyors 3 Map of a Survey made for Francis T. & A. Joyce Donohue Dated April 02, 2003 By Van Dusen & Steves Land Surveyors Legend B.R.F. = Bathey Rod Found CIRF = Capped Iron Rod Found IRF = Iron Rod Found = Wood Fence Line = Utility Pole    “    “ 10' W i d e R i g h t - O f - W a y F r o m G l e n L a k e R a o d t o G l e n L a k e a s Per 4 8 4 / 1 1 6 - 5 2 1 / 1 8 3 - 5 2 1 / 1 8 5 - 1 1 0 4 / 2 4 2 (Ex i s t i n g L o t L i n e ) 289 . 1 0 - 1 - 5 2 . 2 D E E D P A R C E L I I D E E D P A R C E L I I I D E E D P A R C E L I (Fo r m e r L i f e E s t a t e t o P a t r i c k S p a d a r o ) 1  ƒ       ( 206 . 9 9 ' 10660.0 Sq. Feet 0.299 Acres 22716.5 Sq. Feet 0.52 Acres    “ DWG. NO. 16-051 Zemanek (IN FEET) 050'25'50'100' NOTE # SEE DRAWING # FOR NOTE DETAIL # SEE DRAWING # FOR DETAIL DETAIL REFERENCE TAG: NOTE REFERENCE TAG: SECTION CUT DIRECTION SECTION LETTER SEE DRAWING # FOR SECTION SECTION REFERENCE TAG: LEGEND: REVISION INDICATOR: 1 D1 A D1 NOTE: G-1 C1 X TP # PT # PERCOLATION TEST: TEST HOLE: EXISTING STRUCTURES/OBJECTS/UTILITIES SURVEYED AND OR FIELD VERIFIED: PROPOSED STRUCTURES/OBJECTS/ UTILITIES: LINE TYPE: PROPERTY LINE: 12 EAST WASHINGTON STREET GLENS FALLS, N.Y.PHONE: (518) 792-2907 PRO # JARRETT En gineers, PLLC Civil & Environmental En gineerin g 22-003 -LOCATION PLAN SCALE: N.T.S. 1 NEIGHBORHOOD PLAN SCALE: SEE GRAPHIC SCALE PAUL ZEMANEK ZEMANEK RESIDENTIAL DEVELOPMENT ELM DRIVE ON GLEN LAKE TOWN OF QUEENSBURY, NEW YORK GR I D -ZONE MAP SCALE: N.T.S. SITE LOCATION SITE LOCATION GR I D RT. 143 TO GLENS FALLS TO NORTH QUEENSBURY/ LAKE GEORGE GLEN LAKE ROAD DESIGN INFORMATION: PROPERTY INFORMATION: -OWNER: PAUL ZEMANEK -APPLICANT: PAUL ZEMANEK -ZONING: WATERFRONT RESIDENTIAL (WR) -TAX MAP# 289.10-1-52.1 & 289.10-1-52.2 -PARCEL SIZE: 289.10-1-52.1 = 0.72± ACRES & 289.10-1-52.2 = 0.05± ACRES -STEEP SLOPES: MODERATE ALONG SHORELINE -WETLANDS: PROPERTY WITHIN STATE REGULATED WETLAND CHECK ZONE -SHORELINE OF PROPERTY IN ZONE A,AE FEMA 100 YR FLOODPLAIN TOWN OF QUEENSBURY JURISDICTION: -LOT LINE ADJUSTMENT -QUEENSBURY (ZONING) AREA VARIANCES: LOT 1 & LOT 2 -QUEENSBURY (PLANNING) SITE PLAN REVIEW: LOT 2 DEVELOPMENT: DISTRICT: WATERFRONT RESIDENTIAL (WR) - 2 ACRES PER LOT DENSITY: EXISTING LOT 1: 0.72± ACRES EXISTING LOT 2: 0.05± ACRES 0.72± ACRES + 0.05± ACRES = 0.77± ACRES 0.77± ACRES - 0.07± ACRES OF STEEP SLOPES = 0.70± NET DEVELOPABLE ACRES PROPOSED LOTS: #1 - 0.315± ACRES TOTAL - 0.034± ACRES OF SLOPES = 0.29± NET DEVELOPABLE ACRES #2 - 0.455± ACRES TOTAL - 0.042± ACRES OF SLOPES = 0.41± NET DEVELOPABLE ACRES 0.29± NET DEVELOPABLE ACRES + 0.41± NET DEVELOPABLE ACRES = 0.70± ACRES LOT ACCESS: -SHARED DRIVEWAY FOR BOTH LOT 1 AND 2 WATER SUPPLY: -LOT 1: PROPOSED DRILLED WELL -LOT 2: PROPOSED CONNECTION TO EXISTING DRILLED WELL IN ACCORDANCE WITH TOWN OF QUEENSBURY AND NYSDOH STANDARDS WASTEWATER MANAGEMENT: -LOT 1: EXISTING WASTEWATER TREATMENT SYSTEM -LOT 2: PROPOSED WASTEWATER TREATMENT SYSTEMS IN ACCORDANCE WITH TOWN OF QUEENSBURY AND NYSDOH STANDARDS STORMWATER MANAGEMENT & EROSION CONTROL: -PER TOWN OF QUEENSBURY & NYSDEC STANDARDS ELECTRIC POWER: -LOT 1: EXISTING ELECTRIC & GAS SERVICE BY NATIONAL GRID; CABLE & PHONE SERVICE BY VERIZON AND/OR SPECTRUM, ETC. -LOT 2: PROPOSED ELECTRIC & GAS SERVICE BY NATIONAL GRID; CABLE & PHONE SERVICE BY VERIZON AND/OR SPECTRUM, ETC. SCHOOL DISTRICT: -LAKE GEORGE SITE LOCATION; WATERFRONT RESIDENTIAL (WR) ZONE GENERAL NOTES: G-1) LOCATION PLAN IMAGERY AND NEIGHBORHOOD PLAN WITH TAX MAP INFORMATION OBTAINED FROM WARREN COUNTY COMMUNITY MAP GIS; ZONE MAP IMAGERY OBTAINED FROM QUEENSBURY ZONING MAP. GLEN LAKE GLEN LAKE R O A D GR I D RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 REV #DATE ISSUED / REVISIONS 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING NOT FOR CONSTRUCTION "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." SHED 10' Right of Way As Per Deed Reference B.484 P. 116, B.1104 P. P.242 N 4 6 ° 4 7 ' 0 1 " E 218 . 9 3 ' S 4 3 ° 1 2 ' 5 9 " E 1 0 0 . 0 0 ' S 43°12'59" E 50.00' 209 . 8 7 ' S 4 6 ° 4 7 ' 0 1 " W S 46°47'01" W 17.71' Proposed Area 289.10-1-52.2 Area 5 0 . 0 0 ' N 3 9 ° 5 4 ' 5 1 " W 1 0 0 . 1 7 ' N 3 9 ° 5 4 ' 5 1 " W Doc k 2 n d S t o r y D e c k Con c r e t e W a l k Con c r e t e W a l k 2 S t o r y Woo d F r a m e H o u s e 10' W i d e R i g h t - O f - W a y F r o m G l e n L a k e R a o d t o G l e n L a k e a s Per 4 8 4 / 1 1 6 - 5 2 1 / 1 8 3 - 5 2 1 / 1 8 5 - 1 1 0 4 / 2 4 2 Sh e d Le a n T o She d Ti m b e r R e t a i n i n g W a l l Propane Tank Well Crushed Stone ParkingFlag Pole 2.1' ± To Shore 2.1' ± To Shore 7 5 . 6 ' ± A l o n g S h o r e 7 5 . 2 ' ± A l o n g S h o r e ( T i e L i n e ) ( T i e L i n e ) 289.10-1-52.1 5.7' ± To Shore Lands N/F of Harvey D. Wilson 2 St o r y Woo d F r a m e H o u s e CIRF IRF Square Fence Post Found B.R.F. Lands N/F of Zemanek Lands N/F of Miller Lands N/F of Gary G. Pinero Lands N/F of Betty Spadaro Asp h a l t D r i v e 1 5 . 3 3 ' 1 6 . 8 6 ' 10' W i d e R i g h t - O f - W a y F r o m G l e n L a k e R a o d t o G l e n L a k e a s Per 4 8 4 / 1 1 6 - 5 2 1 / 1 8 3 - 5 2 1 / 1 8 5 - 1 1 0 4 / 2 4 2 (Ex i s t i n g L o t L i n e ) 289 . 1 0 - 1 - 5 2 . 2 D E E D P A R C E L I I D E E D P A R C E L I I I D E E D P A R C E L I (Fo r m e r L i f e E s t a t e t o P a t r i c k S p a d a r o ) N 4 6 ° 4 7 ' 0 1 " E 206 . 9 9 ' 10660.0 Sq. Feet 0.299 Acres 22716.5 Sq. Feet 0.52 Acres 100' NEIGHBORING WELL OFFSET 100' NEIGHBORING WELL OFFSET 100' WELL OFFSET (IN FEET) 020'10'20'40' REV #DATE ISSUED / REVISIONS 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING NOT FOR CONSTRUCTION GENERAL NOTES: G-1) SURVEY & MAP INFORMATION PROVIDED BY VAN DUSEN AND STEVES LAND SURVEYORS. "MAP OF SURVEY MADE FOR PAUL AND CORINA ZEMANEK. TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK". MAP DATED 06/09/2016, REVISED 10/03/17. G-2) CONTRACTOR TO LOCATE EXISTING UTILITIES PRIOR TO CONSTRUCTION; CONTACT DIG SAFELY NEW YORK (1-800-962-7962) AND RECORD FILE #. VERIFY BUILDING CONNECTIONS, LOCATION AND ELEVATION, PRIOR TO INITIATING CONSTRUCTION; CONFLICTS OR DISCREPANCIES SHALL BE REPORTED TO THE OWNER OR ENGINEER IMMEDIATELY. NOTIFY ENGINEER IMMEDIATELY IF SITE CONDITIONS ARE NOT AS INDICATED. ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering EXISTING CONDITIONS EX1 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 2 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 2 EXISTING CONDITIONS SCALE: SEE GRAPHIC SCALE TP # 221027-01 A PT # 221027-01 TP # 221027-01 TP # 221027-02 PT # 221027-02 TP # 221027-03 PT # 221027-03 TP # 221027-04 PT # 221027-04 TP # 221027-05 PT # 221027-05 TP # 221027-06 PT # 221027-06 TP # 221027-07 PT # 221027-07 TP # 221027-08 PT # 221027-08 "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 R.U. HOLMES ENGINEERS, PLLC. R.U. HOLMES ENGINEERS, PLLC. NO R T H APPROXIMATE LOCATION OF NEIGHBORING WELL APPROXIMATE LOCATION OF NEIGHBORING WASTEWATER APPROXIMATE LOCATION OF NEIGHBORING WASTEWATER APPROXIMATE LOCATION OF NEIGHBORING LAKE WATER SUPPLY APPROXIMATE LOCATION OF EXISTING ON-SITE WELL APPROXIMATE LOCATION OF NEIGHBORING WASTEWATER 218 . 9 3 ' 1 0 0 . 0 0 ' 5 0 . 0 0 ' 209 . 8 7 ' 17.7 1 ' Doc k Con c r e t e W a l k Con c r e t e W a l k She dR e t a i n i n g W a l l Pr o p a n e Lands N/F of Harvey D. Wilson 2 St o r y Woo d F r a m e H o u s e Lands N/F of Zemanek Lands N/F of Gary G. Pinero Lands N/F of Betty Spadaro 15.33' 16.86' PRO P O S E D HOU S E 86.58 63.66 50.00' 30.00 EXIS T I N G HOU S E 30.00 10" 10" 20.00' 20.00' 1 3 . 5 6 ' 212 . 6 7 ' SW- E SW- A SW - C SW - A LOT 2 LOT 1 20.00' 20.00' SW - B SW - D 15.00' 100' WELL OFFSET 100' NEIGHBORING WELL OFFSET 20.00' SW-E SW-B 0.315 AC 50.00' SW - D SW - B 0.455 AC 37.03 Well Sh e d Le a n T o 100' NEIGHBORING WELL OFFSET 30' 100' WELL OFFSET 54.76' 29.23' 29.21' 133.75' (IN FEET) 020'10'20'40' REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering SITE PLAN C1 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 3 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 3 SITE PLAN SCALE: SEE GRAPHIC SCALE PROPOSED AREA FOR WASTEWATER LEACH FIELD AND EXPANSION AREA PROPOSED DRIVEWAY CONFIGURATION FOR NEW HOUSE ON LOT 2 PROPOSED AREAS FOR STORMWATER MANAGEMENT, TYP. PROPOSED DRIVEWAY CONFIGURATION FOR EXISTING HOUSE ON LOT 1 PROPOSED AREAS FOR STORMWATER MANAGEMENT, TYP. EXISTING DRILLED WELL DRAWING NOTES: POTENTIAL DEVELOPMENT: 1.) DEVELOPMENT DEPICTED ON THESE DRAWINGS IS INTENDED TO SHOW THAT THE LOTS ARE FEASIBLE FOR RESIDENTIAL DEVELOPMENT WHICH IS IN CONFORMANCE WITH STANDARDS IN EFFECT AT THE TIME OF LOT LINE ADJUSTMENT/SUBDIVISION. THE DEVELOPMENT SHOWN IS NOT INTENDED TO BE THE ONLY CONFIGURATION THAT IS APPROPRIATE FOR THESE LOTS, AND ALTERNATIVES PROPOSED BY FUTURE OWNERS ARE SUBJECT TO THE REQUIREMENTS SHOWN ON THESE PLANS. 2.) ALL DEVELOPMENT IN THIS LOT LINE ADJUSTMENT/SUBDIVISION SHALL FOLLOW THE REQUIREMENTS SET FORTH ON THIS SET OF DRAWINGS. STORMWATER CONSTRUCTION: 1.) UPON COMPLETION OF CONSTRUCTION ON STORMWATER DEVICES, PROVIDE SEDIMENTATION PROTECTION DURING REMAINDER OF CONSTRUCTION BY MEANS OF ONE OF THE PRACTICES LISTED UNDER 'SEDIMENT CONTROL BARRIER' ON 'ENVIRONMENTAL CONTROL DETAILS' DRAWING 'EC1'. ADDITIONAL PROTECTION CAN BE AFFORDED BY APPLYING IMMEDIATE SITE VEGETATIVE STABILIZATION AND/OR MULCHING. WASTEWATER DESIGN INFORMATION: -NEW YORK STATE DEPARTMENT OF HEALTH -TOWN OF QUEENSBURY POTABLE WATER SUPPLY: EXISTING DRILLED WELL CURRENTLY SUPPLIES LOT 1; AND IS PROPOSED TO SUPPLY LOT 2. NEW 2" (MIN.) HDPE WATER SERVICE LINE TO LOT 2 DEVELOPMENT; INSTALLATION SHALL BE IN ACCORDANCE WITH QUEENSBURY WATER DEPARTMENT, AWWA, AND NYSDOH STANDARDS. NO KNOWN EXISTING POTABLE WATER SUPPLIES LOCATED WITHIN 100' OF PROPOSED WASTEWATER DISPOSAL SYSTEM. DESIGN FLOW: SEE 'WASTEWATER LEACHING SYSTEM SIZING' CHART (INSTALLATION OF WATER SAVER FIXTURES THROUGHOUT RESIDENCE REQUIRED, NO KITCHEN GARBAGE GRINDERS OR SPAS / HOT TUBS CONNECTED TO WASTEWATER DISPOSAL SYSTEM) SEPTIC TANK: SEE 'WASTEWATER LEACHING SYSTEM SIZING' CHART SEPTIC TANK EFFLUENT FILTER: PROVIDE (1) MODEL A1801-4X22, 'ZABEL' RESIDENTIAL FILTER LEACHING SYSTEM (TRENCH SYSTEM): SEE 'WASTEWATER LEACHING SYSTEM SIZING' CHART FOR TOTAL DAILY FLOW AND MINIMUM LENGTH OF QUICK 4 'EQUALIZER 36' TRENCH REQUIRED. EFFLUENT DISTRIBUTION: GRAVITY DOSING / DISTRIBUTION FROM SEPTIC TANK WASTEWATER SYSTEM SIZING # BEDROOMS (GPD)LATERAL LENGTH (FT)BASAL AREA (SQ. FT.)SEPTIC TANK SIZE (GALS) 3 BEDROOM (330 GPD)104 1,650 1,000 4 BEDROOM (440 GPD)138 2,200 1,250 5 BEDROOM (550 GPD)172 2,750 1,500 NOTE: LATERAL LENGTHS BASED ON A 25% REDUCTION IN TOTAL LATERAL LENGTH IF LEACHING CHAMBERS WITH A MINIMUM WIDTH OF 22" PROVIDED. LOT 1 AREA VARIANCES REQUESTED FROM THE TOWN OF QUEENSBURY VARIANCE:REQUIRED:PROPOSED LOT 1: 1.MINIMUM LOT SIZE 2.0 AC 0.315 AC 2.MINIMUM LOT WIDTH 150'63.56' 3.MINIMUM ROAD FRONTAGE 150'50' 4.MINIMUM WATER FRONTAGE 150'63.72' 1 1 2 3 4 2 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING EXISTING POWER LINE TYP. EXISTING POWER LINE TYP. LOT 2 AREA VARIANCES REQUESTED FROM THE TOWN OF QUEENSBURY VARIANCE:REQUIRED:PROPOSED LOT 2: 1.MINIMUM ROAD FRONTAGE 150'0' 2.ACCESS THROUGH NEIGHBORING PROPERTY N/A NEEDED EXISTING WALKWAYS PROPOSED FOR REMOVAL, TYP. - 507 SQ. FT. "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 APPROXIMATE AREA OF EXISTING SEPTIC FOR EXISTING HOUSE ON LOT 1 EXISTING POINT WELL PROPOSED FOR REMOVAL, TYP. - 18 SQ. FT. EXISTING SHED WITH LEAN TO PROPOSED FOR REMOVAL, TYP. - 178 SQ. FT. EXISTING SHED PROPOSED FOR REMOVAL, TYP. - 33 SQ. FT. NO R T H AREAS OF DRIVEWAY PROPOSED FOR REMOVAL, -1496 SQ. FT. LIGHTING NOTES: 1) ALL PROPOSED LIGHTS TO BE DOWN CAST DARK SKY COMPLIANT FIXTURES. A,2 WD1 2 RG1 2 RG1 PROPOSED EROSION AND SEDIMENT CONTROLS 1 EC1 PROPOSED DRILLED WELL REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering STORMWATER AND SITE DATA C2 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 4 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 LOT 1: SITE DEVELOPMENT DATA LOT 1: STORMWATER CALCULATIONS LOT 2: SITE DEVELOPMENT DATA LOT 2: STORMWATER CALCULATIONS 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 218 . 9 3 ' 1 0 0 . 0 0 ' 5 0 . 0 0 ' 209 . 8 7 ' 17.7 1 ' Doc k Con c r e t e W a l k Con c r e t e W a l k She dR e t a i n i n g W a l l Pr o p a n e Lands N/F of Harvey D. Wilson 2 St o r y Woo d F r a m e H o u s e Lands N/F of Zemanek Lands N/F of Gary G. Pinero Lands N/F of Betty Spadaro PRO P O S E D HOU S E EXIS T I N G HOU S E 1 3 . 5 6 ' 212 . 6 7 ' SW- E SW- A SW - C SW - A LOT 2 LOT 1 SW - B SW - D SW-E SW- B 0.315 AC SW - D SW - B 0.455 AC Well Sh e d Le a n T o (IN FEET) 020'10'20'40' REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering PLANTING PLAN C3 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 5 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 4 PLANTING PLAN SCALE: SEE GRAPHIC SCALE 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 NO R T H EXISTING VEGETATION, TYP. EXISTING SCREENING HEDGE EXISTING SHORELINE PLANTINGS EXISTING SHORELINE PLANTINGS EXISTING SCREENING HEDGE EXISTING VEGETATION, TYP. SHORELINE BUFFER REQUIREMENTS FOR THE TOWN OF QUEENSBURY 35' BUFFER ZONE X 87' ALONG SHORELINE = 3,045 SF OF BUFFER AREA REQUIRED:EXISTING:ADDITIONAL: 1)TREES: 1 LARGE TREE, 3" DIAMETER AT BREAST HEIGHT FOR EVERY 700 SF OF BUFFER AREA. (3,045 / 700 = 4.35 = 5 TREES)5 15 0 2)SHRUBS: 7 LARGE SHRUBS FOR EVERY 350 SF OF BUFFER AREA (3,045 / 350 = 8.7 X 7 = 60.9 = 61 SHRUBS)61 32 29 3)HERBACEOUS PLANTS: 14 PLANTS FOR EVERY 350 SF OF BUFFER AREA (3,045 / 350 = 8.7 X 14 = 121.8 = 122 PLANTS)122 77 45 SHORELINE BUFFER NOTES: 1) REQUESTING CREDIT FOR EXCESS TREES OVER THE AMOUNT REQUIRED FOR A REDUCTION IN SHRUBS AND PERENNIALS. POTENTIAL NATIVE PLANTINGS SEE QUEENSBURY PLANT LIST FOR ADDITIONAL OPTIONS SCIENTIFIC NAME COMMON NAME MIN. SIZE COMMENTS Tsuga Canadensis Canadian Hemlock 2" Cal. / 10'-12'B & B Pinus Strobus White Pine 2" Cal. / 10'-12'B & B Acer Rubrum Red Maple 3" Cal. / 14'-16'B & B Quercus Palustris Pin Oak 3" Cal. / 14'-16'B & B Betula Nigra River Birch 3" Cal. / 14'-16'B & B Cercis Canadensis Eastern Redbud 2" Cal. / 10'-12'B & B Amelanchier Canadensis Serviceberry 2" Cal. / 10'-12'B & B Cornus Florida Flowering Dogwood 2" Cal. / 10'-12'B & B Aronia Arbutifolia Red Chokeberry 2 Gal.Container Viburnum Dentatum Arrowwood Viburnum 2 Gal.Container Cornus Alba 'Sibirica'Red Twig Dogwood 2 Gal.Container Viburnum Acerfolium Maple-leaf Viburnum 2 Gal.Container Clethera Alnifolia Summersweet 2 Gal.Container Comptonia Peregrina Sweet Fern 2 Gal.Container Hydrangea Arborescens Smooth Hydrangea 2 Gal.Container Rhododendron Rhododendron 2 Gal.Container Physocarpus Opulifolius Ninebark 2 Gal.Container Juniperus Horizontalis Creeping Juniper 2 Gal.Container Kalmia Latifolia Mountain Laurel 2 Gal.Container Monarda Spp.Bee Balm 1 Gal.Container Symphyotrichum Novae-Angliae New England Aster 1 Gal.Container Rudbeckia Hirta Black-Eyed Susan 1 Gal.Container Aquilegia Columbine 1 Gal.Container Lobelia Siphilitica Great Blue Lobelia 1 Gal.Container Heuchera, spp.Coral Bell 1 Gal.Container Echinacea Purpurea Purple Coneflower 1 Gal.Container Asclepias Incarnata Swamp Milkweed 1 Gal.Container Arctostaphylos Uva-Ursi Bearberry 1 Gal.Container Andropogon Gerardii Big Bluestem Grass 1 Gal.Container Panicum Virgatum Switch Grass 1 Gal.Container Matteuccia Struthiopteris Ostrich Fern 1 Gal.Container Astilbe Spp.Astilbe 1 Gal.Container Athyrium Niponicum Painted Fern 1 Gal.Container Parthenocissus Quinquefolia Virginia Creeper 1 Gal.Container Iris Versicolor Blue Flag Iris 1 Gal.Container LANDSCAPING NOTES: 1.) ALL TREES SHALL BE MIN. 4' HIGH AND/OR 1-1/2" DBH, WHICHEVER IS GREATER, AND SHALL BE GUARANTEED FOR ONE FULL GROWTH SEASON FOLLOWING PLANTING. 2.) SHRUBS SHALL BE 2 GALLON CONTAINER, MIN., OR EQUIVALENT SIZE AND SHALL BE GUARANTEED FOR ONE FULL GROWING SEASON. 3.) HERBACEOUS PERENNIALS SHALL BE 1 GALLON SIZE OR LARGER. 4.) ALL PLANTINGS SHALL BE SUPPLIED FROM A SOURCE APPROVED BY ENGINEER, AND SHALL BE PLANTED IN ACCORDANCE WITH DETAILS HEREIN OR IN ACCORDANCE WITH NURSERY RECOMMENDATIONS. PROPOSED SHORELINE SHRUB PLANTINGS, TYP. PROPOSED SHORELINE PERENNIAL PLANTINGS, TYP. 35' SHORELINE SETBACK 2'-01 16" PERMANENT MARKER OVER COVER 12" (MIN.) WATERTIGHT JOINTS (TYP.) FINISHED GRADE PRECAST CONCRETE RISER AS REQ'D EFFLUENT PIPE; INSTALL AS SHOWN ON PLAN UNDISTURBED NATIVE SOIL FORT MILLER PRECAST SEPTIC TANK OR EQUIVALENT NATIVE BACKFILL THOROUGHLY COMPACTED CRUSHED STONE FOUNDATION SOIL PIPE; INSTALL AS SHOWN ON 'SYSTEM PLAN' INLET 12" (MIN.) OUTLET 15" PROVIDE EXTENDED BASE FOR ANTI-FLOTATION PURPOSES OR EQUIVALENT 6" (MIN.) 3" 1 WD1 SEPTIC TANK DETAIL NON-SHRINK GROUT NSF APPROVED EFFLUENT FILTER ("POLYLOK PL-122", OR EQUIVALENT) 18" MIN.4" SANITARY TEE WATERTIGHT MANHOLE FRAME & COVER; SYRACUSE CASTINGS #1502 OR EQUIVALENT; GRADE TO DRAIN AWAY FROM COVER 22" 12" OUTLET END END INLET 48" EFFECTIVE 53" ACTUAL 2 WD1 "QUICK 4 EQUALIZER 36" DETAIL SCALE: N.T.S. 4" PVC EQUALIZATION PIPE END PLATE WITH STANDARD END "QUICK 4 EQUALIZER 36" INFILTRATION CHAMBERS 4" PVC DISTRIBUTOR FROM DISTRIBUTION BOX END PLATE WITH STANDARD INVERT A WD1 TYPICAL SECTION THROUGH WASTEWATER LEACHING SYSTEM SCALE: N.T.S. LEACHING LATERAL: 'QUICK 4 EQUALIZER 36' CHAMBER UNIT BY 'INFILTRATOR SYSTEMS, INC.' 2 WD1 GRADE TO DRAIN FINISHED GRADE SEED TO GROWTH & MULCH ALL FILLED & DISTURBED AREAS BACK FILL WITH NATIVE SOIL MINUS COBBLES AND ROCKS IN EXCESS OF 2" Ø EXISTING GRADE 4" MIN. TOPSOIL 2' ±6' O.C. (TYP.)NATIVE SOIL SURFACE PREPARATION L1-L10 WD1 REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering WASTEWATER DETAILS WD1 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 6 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 LEACHING SYSTEM INSTALLATION: L1.LEACHING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ASTM F481, NYSDOH, NYSDEC, AND OTHER APPLICABLE STANDARDS UNLESS OTHERWISE DIRECTED HEREON. L2.REMOVE VEGETATION AND TOPSOIL WITHIN FOOTPRINT OF LEACHING SYSTEM AND STOCK PILE TOPSOIL FOR RE-USE. CONTRACTOR TO EXPOSE LEACHING SYSTEM FOOTPRINT FOR EXAMINATION BY ENGINEER. L3.LEACHING SYSTEM(S) SHALL BE INSTALLED TO (RELATIVE) ELEVATIONS SHOWN, AND ELEVATIONS OF EXISTING GRADE AND SITE FEATURES SHALL BE DOCUMENTED PRIOR TO START OF CONSTRUCTION. L4.FILL MATERIAL, IF REQUIRED FOR LEACHING SYSTEM(S), SHALL BE CLEAN GRANULAR SOIL (SAND OR LOAMY SAND) DEVOID OF LARGE STONES, CLAY, ORGANIC DUFF, & NON-SOIL COMPONENTS (DEBRIS, ETC.). PERCOLATION RATE(S) OF FILL SHALL BE AS SPECIFIED ON PLANS AND/OR IN DETAILS. PERCOLATION RATE(S) TO BE VERIFIED BY A QUALIFIED INDEPENDENT PARTY (I.E. SOIL SCIENTIST OR PROFESSIONAL SOILS ENGINEER) IN BORROW PIT PRIOR TO EXCAVATION; SUBMIT WRITTEN RESULTS TO OWNER AND ENGINEER AT LEAST FIVE BUSINESS DAYS PRIOR TO HAULING. L5. FILL SHALL BE GRADED AND THOROUGHLY COMPACTED IN SIX-INCH LIFTS. THE FILL SHALL BE GRADED TO THE LIMITS AND DEPTHS DEPICTED ON THE PLANS AND DETAILS. L6.PERCOLATION TESTS SHALL ALSO BE PERFORMED (IN ACCORDANCE WITH NYSDOH STANDARDS) IN PLACE IN LEACHING SYSTEM FOLLOWING COMPACTION. PERCOLATION TEST(S) TO VERIFY FILL SUITABILITY SHALL BE PERFORMED AT THE FREQUENCY SPECIFIED ON THE PLAN AND/OR SECTION. FAILING TESTS SHALL REQUIRE ADDITIONAL TESTS EVERY 1000 SF AROUND EACH FAILED TEST UNTIL THE LIMITS OF FAILING SOIL ARE IDENTIFIED. FAILING SOIL SHALL BE REMOVED AND REPLACED WITH COMPLIANT SOIL. L7.IN NO CASE SHALL WHEELED EQUIPMENT, EXCEPT PLOWS WHERE REQUIRED, BE ALLOWED DIRECTLY ON THE SOIL WITHIN THE LEACHING AREA FOOTPRINT. (NO RUBBER TIRED EQUIPMENT SHOULD EVER BE ALLOWED WITHIN THE WASTEWATER ABSORPTION AREA). TRACKED EQUIPMENT SHALL BE USED FOR INSTALLATION, AND WHERE FILL MATERIAL IS REQUIRED, IT SHALL BE DUMPED AT THE EDGE OF THE LEACHING AREA AND PUSHED IN PLACE AHEAD OF THE EQUIPMENT; TRACKED EQUIPMENT SHALL BEAR DIRECTLY ON 12” MINIMUM OF FILL MATERIAL AND NOT ON NATIVE SOIL. L8.INSTALL LEACHING SYSTEM COMPONENTS, INCLUDING CHAMBER UNITS WHERE APPLICABLE, PER MANUFACTURERS RECOMMENDATIONS UNLESS OTHERWISE DIRECTED HEREON. VERIFY THAT SYSTEM IS AT CORRECT ELEVATION(S) USING A LEVEL, TRANSIT, OR LASER. L9.SEQUENCE OF CONSTRUCTION TO BE AS FOLLOWS: ·FIND FILL SOURCE AND VERIFY SUITABILITY WITH PERC TESTS AT SOURCE. ·ALL TREES SHALL BE CUT AT GRADE; STUMPS WITHIN THE LEACHING SYSTEM FOOTPRINT SHALL BE REMOVED IF REQUIRED FOR SITE PREPARATION. ·REMOVE AND STOCKPILE TOPSOIL FOR PLACEMENT ON THE FINISHED SYSTEM. ·EXCAVATE TO DESIGNED SUBGRADE (IF NECESSARY); EXAMINE SUBGRADE FOR POOR (SLOWLY PERMEABLE) SOILS, BEDROCK, DELETERIOUS MATERIALS, SMEARING, ETC. REMOVE DELETERIOUS MATERIAL, INCLUDING SLOWLY PERMEABLE SOILS, WITHIN SYSTEM FOOTPRINT, AS DIRECTED BY ENGINEER. ·SCARIFY SUBGRADE; CHECK FOR AND REMOVE SMEARING AS REQUIRED PRIOR TO PLACEMENT OF SPECIFIED GRANULAR FILL. ALSO, RAKE THE LEACHING AREA JUST PRIOR TO PLACEMENT OF THE LEACHING DEVICE, INCLUDING UNDER CHAMBERS TO LOOSEN COMPACTION DUE TO FOOT TRAFFIC. ·PLACE AND COMPACT SYSTEM FILL IMMEDIATELY AFTER SUBGRADE HAS BEEN PREPARED AND APPROVED, TO REQUIRED ELEVATION. ·PERFORM PERCOLATION TESTS IN THE PLACED FILL MATERIAL TO CONFIRM DESIGN RATE. ·INSTALL LEACHING DEVICE TO GRADES AND IN CONFIGURATION SHOWN ON PLANS / SECTIONS. ·BACKFILL AROUND AND ABOVE THE LEACHING DEVICE WITH SOIL SPECIFIED ON PLANS; CARE SHALL BE TAKEN TO COMPACT SOIL IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS SO THAT THERE WILL BE NO DAMAGE OR DISRUPTION OF LEACHING SYSTEM DEVICE OR SUBGRADE SOILS. ·CROWN THE FILL TO DRAIN, AND INSTALL THE RESERVED NATIVE TOPSOIL, AND/OR A CLAYEY LOAM OR SILTY LOAM TOPSOIL, CAP AS DEPICTED ON THE PLANS (TO ALLOW OXYGEN TRANSFER BUT LITTLE INFILTRATION OF PRECIPITATION). ·SEED/PLANT, AND THEN MULCH, ENTIRE SYSTEM; MAINTAIN UNTIL GROWTH IS ESTABLISHED. 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 1 WD2 PIPE TRENCH: WATER & SEWER LINES SCALE: N.T.S. 18" ± 4" MIN (6" IF ROCK BELOW) 6" MIN. (TYP.) 18" MIN SEE NOTES BELOW 1) BURIAL DEPTH: SEWER: 4'0" MIN. COVER; WATER: 5'-6" MIN. COVER. 2A) WATER LINES: IF AVAILABLE DEPTH PROVIDES BETWEEN 3'-0" AND 5'-6" COVER, PROVIDE RIGID FOAM INSULATION OVER AND/OR AROUND PIPE. IF AVAILABLE DEPTH PROVIDES LESS THAN 3'-0" COVER, CONTACT ENGINEER FOR ASSISTANCE. 2B) SEWER LINES: IF AVAILABLE DEPTH PROVIDES BETWEEN 2'-0" AND 4'-0" COVER, PROVIDE RIGID INSULATION OVER AND/OR AROUND PIPE. IF AVAILABLE DEPTH PROVIDES LESS THAN 2'-0" COVER, REFER TO 'SHALLOW PIPE INSTALLATION' DETAIL. 3) IN VEHICULAR TRAFFIC AREAS, IF 3'0" COVER CANNOT BE ACHIEVED, PIPE(S) SHOULD BE PLACED IN A PROTECTIVE CASING(S). 2 WD2 SHALLOW PIPE INSTALLATION SCALE: N.T.S. 10"± TREATED LUMBER MARKER ABOVE ALL BURIED COVERS; SET LEVEL W/ GRADE PROVIDE ADJUSTABLE LEVELING DEVICE ON EACH OUTLET 4" PVC GRAVITY SEWER @ 0.5% MIN. SLOPE 12" MIN. OF CLEAN SAND OR PEA GRAVEL FOUNDATION 3 WD2 DISTRIBUTION BOX SCALE: N.T.S. INLET OUTLET FORT MILLER BOX OR EQUIVALENT REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering WASTEWATER DETAILS WD2 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 7 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 GENERAL WASTEWATER NOTES G-1 CONSTRUCTION OF NEW PIPING, TANKS, AND LEACHING SYSTEM(S), ETC. SHALL BE IN CONFORMANCE WITH APPLICABLE NYSDEC, NYS DEPT. OF HEALTH, AND LOCAL COUNTY/TOWN STANDARDS, AS WELL AS DETAILS / SPECS ON THESE DOCUMENTS. CONFLICTS SHALL BE BROUGHT TO ENGINEERS ATTENTION PRIOR TO CONSTRUCTION. G-2 INSTALLATION OF WATER SAVER FIXTURES THROUGHOUT RESIDENCE REQUIRED (POST 1994). NO KITCHEN GARBAGE GRINDERS, OR SPAS/HOT TUBS ARE TO BE CONNECTED TO THE WASTEWATER DISPOSAL SYSTEM. PIPING P-1)ALL GRAVITY SEWER PIPE & FITTINGS SHALL BE PVC SDR 26 OR 35 (SEE PLANS), ASTM D3034; OR HPDE SDR 17, ASTM D3350; INSTALLATION SHALL BE IN ACCORDANCE WITH ASTM D2321, UNI-BELL “HANDBOOK OF PVC PIPE, DESIGN, AND INSTALLATION”, AND MANUFACTURER'S RECOMMENDATIONS. P-2)GRAVITY SEWER PIPE JOINTS TO BE BELL & SPIGOT PUSH ON TYPE, ASTM D1312, DESIGNED FOR USE WITH PROJECT PIPING P-3)GRAVITY SEWER SHALL BE INSTALLED AT STRAIGHT & CONTINUOUS GRADE BETWEEN STRUCTURES (I.E. NO LOW OR HIGH POINTS), UNLESS OTHERWISE DIRECTED HEREON OR BY ENGINEER. GRAVITY SEWER SHALL BE LAID AT THE FOLLOWING MINIMUM GRADES UNLESS OTHERWISE DIRECTED ON PLANS: RAW SEWAGE: 4” @ 2%, 6” @ 1%; SETTLED SEWAGE (EFFLUENT): 4” AND 6” @ 0.5%±. ALL SEWER SHALL BE LEAKAGE TESTED BY A NYSDEC APPROVED METHOD. P-4)FORCE MAIN SHALL BE HDPE, ASTM D2239 OR F714, 100 PSI MIN PRESSURE RATING; OR, PVC, ASTM D2241, 100 PSI MIN PRESSURE RATING; FORCE MAIN TO BE INSTALLED PER ASTM D2774 AND PIPE MANUFACTURER'S RECOMMENDATIONS. FORCE MAIN FITTINGS SHALL BE RESTRAINED OR THRUST BLOCKED TO PREVENT MOVEMENT. FORCE MAIN TO BE PRESSURE TESTED BY A NYSDEC APPROVED METHOD. P-5)HDPE PIPE AND FITTINGS ARE TO BE JOINED BY THE BUTT (HEAT) FUSION PROCESS, AND JOINING EQUIPMENT SHOULD BE AS APPROVED BY THE MANUFACTURER. PROPERLY EXECUTED ELECTRO-FUSION FITTINGS MAY BE USED. EXTRUSION WELDING OR HOT GAS WELDING OF HDPE PIPING SHOULD NOT BE USED FOR APPLICATIONS WHERE SHEAR OR STRUCTURAL STRENGTH IS IMPORTANT. MECHANICAL JOINT ADAPTER, FLANGES, UNIONS, GROOVED COUPLERS, TRANSITIONS FITTINGS, AND SOME MECHANICAL COUPLINGS MAY BE USED TO MECHANICALLY CONNECT HDPE PIPE. REFER TO MANUFACTURES RECOMMENDATIONS. P-6)SCH 40 PVC PIPE AND FITTINGS ARE TO BE JOINED BY A SOLVENT WELD PROCESS, OR OTHER APPROVED METHOD, IN ACCORDANCE WITH PIPE MANUFACTURER'S RECOMMENDATIONS. MECHANICAL JOINT ADAPTER, FLANGES, UNIONS, GROOVED COUPLERS, TRANSITION FITTINGS, AND SOME MECHANICAL COUPLINGS MAY BE USED TO MECHANICALLY CONNECT SCH 40 PVC PIPE, IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. P-7)THERMOPLASTIC PIPING MAY BE ROUTED AROUND OBSTRUCTIONS BY BENDING PIPE ON A SMOOTH CURVE, AS RECOMMENDED BY THE MANUFACTURER. TANKS/STRUCTURES T-1)PRECAST STRUCTURES SHALL BE AS SUPPLIED BY FORT MILLER CO., INC. OR EQUIVALENT. REFERENCES TO HEAVY DUTY REFER TO FORT MILLER CO. DESIGNS FOR H-20 TRAFFIC LOADING. HDPE TANKS SHALL BE AS SUPPLIED BY INFILTRATOR WATER TECHNOLOGY, LLC., OR OTHER APPROVED EQUIVALENT. T-2)TANKS/STRUCTURES INSTALLED IN TRAFFIC AREAS SHALL BE HEAVY DUTY CONSTRUCTION (DESIGNED FOR (H-20) WHEEL LOADING). T-3)THE LOCATIONS OF ALL BURIED STRUCTURES SHALL BE DOCUMENTED BY INSTALLATION OF PERMANENT MARKER(S) OVER BURIED COVER(S), AND MEASUREMENT “TIES” TO PERMANENT FEATURES, AND SHOWN ON (RECORD) DRAWINGS (SEE GENERAL NOTES). T-4)ALL TANKS SET BELOW SEASONALLY HIGH GROUNDWATER ELEVATIONS SHALL BE ANCHORED AGAINST POSSIBLE FLOATION USING HEAVY DUTY TANKS WITH 6” EXTENDED INTERGAL BASES, OR BY AN ALTERNATIVE METHOD APPROVED BY ENGINEER. T-5)TANKS/STRUCTURES SHALL BE SEAMLESS CONSTRUCTION OR SHALL HAVE WATERTIGHT JOINTS (ASTM C1227). WALL PENETRATIONS SHALL BE KOR-N-SEAL, OR OTHERWISE WATER TIGHT AS APPROVED BY ENGINEER. TANKS TO BE TESTED WATER TIGHT BY METHOD APPROVED BY ENGINEER (ENGINEER TO WITNESS). T-6)CONTRACTOR TO INSTALL TANKS / STRUCTURES TO (RELATIVE) ELEVATIONS SHOWN; DOCUMENT ELEVATIONS OF EXISTING FEATURES PRIOR TO START OF CONSTRUCTION. T-7)SEPTIC TANKS SHALL HAVE AN NSF APPROVED OUTLET EFFLUENT FILTER DESIGNED FOR THE FLOW RATE/TYPE IN THE SYSTEM. FOR SEPTIC TANKS PLUMBED IN SERIES THE EFFLUENT FILTER SHALL BE LOCATED ON THE OUTLET OF THE DOWNSTREAM TANK ONLY. FRAME AND COVER TO BE PROVIDED OVER FILTER FOR MAINTENANCE ACCESS, AND PERMANENT MARKERS SHALL BE PROVIDED OVER ALL OTHER TANK OPENINGS UNLESS OTHERWISE DIRECTED BY OWNER. 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering RAIN GARDEN DETAILS RG1 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 8 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 2024 4"±(AS REQUIRED) RE-VEGETATE DISTURBED AREA WITH LOW MAINTENANCE NATIVE GROUND COVER; MULCH AS REQUIRED 4 RG1 VEGETATED DIVERSION SWALE SCALE: N.T.S. 1 RG1 RAIN GARDEN ON A SLOPE SCALE: N.T.S. 6"-18" MAX. 1' H MAX. 2'H (24" MIN) STABILIZE SLOPES WITH DEEP ROOTED NATIVE GROUND COVERS AND/OR ROCK KEY BERM INTO EXISTING SOIL (8" TYP) (24" MIN) SEASONAL HIGH GROUNDWATER OR BEDROCK REFER TO 'RAIN GARDEN PLANTING SPECIFICATIONS' (RG-1) FOR PLANT SPECIES SELECTION NATIVE FILL OR EQUIVALENT REFER TO 'RAIN GARDEN PLANTING SPECIFICATIONS' (RG-1) FOR PLANT SPECIES SELECTION 'ADS' 'ADVANEDGE' EDGE DRAIN AS CALLED FOR ON DESIGN PLANS MOUND OVER END OF EDGE DRAIN WITH RIVER ROCK (2"Ø TO 6"Ø) TO ANCHOR IN PLACE AND TO CONCEAL FROM VISIBILITY AND PREVENT INTRUSION OF RODENTS & SMALL ANIMALS MIN. 6" MOUND OVER EDGE DRAIN WITH MIN. 2"-3" SHREDDED HARDWOOD MULCH EDGE DRAIN TO EXTEND TO OPPOSITE WALL OF RAIN GARDEN 'ADS' 'ADVANEDGE' EDGE DRAIN AS CALLED FOR ON DESIGN PLANS EDGE DRAIN TO EXTEND TO OPPOSITE WALL OF RAIN GARDEN 6"-18" SOIL MEDIA: 95%± FINE TO MEDIUM SAND (LESS THAN 5%± CLAY CONTENT) 5%± SANDY TOPSOIL WITH AN AVERAGE OF 5%± ORGANIC (FREE OF STONES, ROOTS, WOODY DEBRIS AND ANIMAL WASTE) WEIR AS DIRECTED ON PLANS 2 MIN. 1 DEEP ROOTED SHRUBS TO PROVIDE ADDED SLOPE STABILITY SEE STORMWATER DEVICE DETAILS FOR CONSTRUCTION DETAILS PROPOSED GRADE 5' MIN. STABILIZED OVER FLOW SWALE 2'± WEIR INLET STABILIZATION GEOTEXTILE/GEOGRID AS REQUIRED KEY EROSION GEOTEXTILE INTO SLOPE KEY EROSION GEOTEXTILE INTO SLOPE STABILIZE SLOPES & WEIR OUTLET PER METHOD OF STABILIZATION NOTED IN TABLE BELOW NOTE: 1. UNLESS OTHERWISE SPECIFIED, ALL WEIR OUTLET OVERFLOWS TO BE SHALLOW AND BROAD CRESTED. WEIR OUTLET STABILIZATION TO BE AS FOLLOWS: 3 RG1 STABILIZED OVERFLOW WEIR SCALE: N.T.S. WEIR OUTLET STABILIZATION BASIN VOLUME (CF)METHOD OF STABILIZATION 0-2500 VEGETATED (SEE NOTE 2) 2500-5000 AMERICAN GREEN 'VMAX P550' PERMANENT EROSION CONTROL MATTING, OR APPROVED EQUIVALENT >5000 ROCK LINED 2. PROVIDE TEMPORARY EROSION CONTROL MATTING AS REQUIRED. 2 RG1 RAIN GARDEN ON A FLAT SITE SCALE: N.T.S. BROAD CRESTED WEIR OR 18" WIDE 'ADS' 'ADVANEDGE' EDGE DRAIN OUTLET, AS CALLED FOR ON PLANS; ELEVATION AS SPECIFIED ON PLANS PERFORATED PIPE CLEAN, WASHED, UNIFORM CRUSHED STONE OR GRAVEL (SEE HOUSE FOUNDATION DESIGN) FONDATION BACKFILL IMPERMEABLE LINER/MEMBRANE (POLY OR PVC) FOR SEPARATION OF STORMWATER FROM FOUNDATION DRAIN SYSTEM NOTE: MEMBRANE TO BE PROVIDED IN RAIN GARDEN(S) ADJACENT TO THE HOUSE (NOT REQUIRED ADJACENT TO THE GARAGE). THIS DETAIL APPLICABLE IF FOUNDATION DRAIN IS WITHIN 10' OF RAIN GARDEN PROPOSED RESIDENCE 6"-18" SOIL MEDIA: 95% FINE TO COARSE SAND (LESS THAN 5% CLAY CONTENT) 5% SANDY TOPSOIL WITH AN AVERAGE OF 5% ORGANIC (FREE OF STONES, ROOTS, WOODY DEBRIS AND ANIMAL WASTE) SEASONAL HIGH GROUNDWATER 48"± (AS REQUIRED) ROUTE TO SPILLWAY RG-1) RAIN GARDEN PLANTING SPECIFICATIONS: 1.ALL PLANTS SHALL BE NATIVE OR NATURALIZED TO UPSTATE NEW YORK, AND SHALL CONFORM TO “AMERICAN STANDARD NURSERY STOCK” STANDARDS AND SHALL BE FROM CERTIFIED LOCAL NURSERIES. 2.RAIN GARDEN AREA: MIXTURE OF HERBACEOUS PLANTS AND SHRUBS TAKEN FROM THE FOLLOWING PLANT LIST: SEDGES, REDTOP, BLUE FLAG IRIS, WINTERBERRY, BUTTONBUSH SILKY DOGWOOD, RED STEM DOGWOOD, ELDERBERRY, JOE PYE WEED, COMMON SPICE BUSH, ARROWOOD VIBURNUM, BAYBERRY, YELLOW LOOSESTRIFE (NOT PURPLE), SKUNK CABBAGE, NEW YORK ASTER, BLUE VERVAIN, OR APPROVED OTHERS. 3.FRINGE AREA: MIXTURE OF HERBACEOUS AND/OR WOODY SHRUBS/TREES FROM THE FOLLOWING LIST: RED CHOKE BERRY, RED MAPLE, ELDERBERRY, EASTERN HEMLOCK, BLACK ASH, EASTERN RED CEDAR, SILKY DOGWOOD, RED STEM DOGWOOD, OR OTHERS AS APPROVED. 4.ALL PLANTS SHALL BE PLANTED AND MAINTAINED PER NURSERY SUPPLIER'S RECOMMENDATIONS. 5.PLANTS SHALL BE SPACED RANDOMLY BUT SHALL AVERAGE 30” O.C. SPACING (MAX). 6.PLANTING SHALL OCCUR DURING MAY-JUNE OR SEPTEMBER-OCTOBER AND SHALL BE GUARANTEED FOR MINIMUM OF 1 YEAR. PLANTS SHALL BE WATERED AS RECOMMENDED BY NURSERY SUPPLIER UNTIL ESTABLISHED. 7.MULCH ENTIRE WETLAND/RAIN GARDEN WITH SHREDDED HARDWOOD FREE OF DYE AND CHEMICALS; MULCH TO BE APPLIED AT A UNIFORM LAYER OF 2”-3” DEPTH. RG-2) BASIN VOLUMES TO BE VERIFIED IN THE FIELD: a.MEASURE BOTTOM AREA IN SQUARE FEET (ON A HORIZONTAL PLANE), AND, b.MEASURE THE AREA AT THE TOP OF THE BASIN AT THE ELEVATION OF THE OVERFLOW WEIR. c.CALCULATE THE AVERAGE OF THE TWO AREAS. d.MEASURE THE VERTICAL DISTANCE BETWEEN WHERE THE BOTTOM AND THE TOP AREAS WERE MEASURED (FEET). e.MULTIPLY THE AVERAGE AREA (SF) X THE VERTICAL DIFFERENCE (FT) TO OBTAIN THE BASIN VOLUME IN CUBIC FEET (CF). INFILTRATION BASIN (RAIN GARDEN) MAINTENANCE NOTES: SEDIMENT: SEDIMENT ACCUMULATIONS OR HEAVY ORGANIC MATTER TO BE REMOVED AS NECESSARY (MAX. 50% BY VOLUME). OUTLETS TO BE CHECKED FOR EROSION AND REPAIRED/UPGRADED AS SOON AS POSSIBLE. APPROPRIATE ELEVATIONS TO BE MAINTAINED ON ALL FEATURES OF THE STORMWATER DEVICE. VEGETATION: PLANTINGS TO BE PERMANENTLY MAINTAINED IN HEALTHY CONDITION. THE PROPERTY OWNER IS RESPONSIBLE FOR REGULAR WEEDING, IRRIGATION, PRUNING, AND OTHER PERMANENT MAINTENANCE OF ALL PLANTINGS AS NEEDED. COMPLIANCE: UP KEEP, MAINTENANCE, PERIODIC INSPECTIONS AND REPORTING TO BE COMPLETED IN ACCORDANCE WITH THE EXECUTED 'STORMWATER CONTROL FACILITY MAINTENANCE AGREEMENT' BETWEEN THE PROPERTY OWNER AND THE PERMITTING AUTHORITY. 01/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907 10' MAXIMUM 8" MIN. (TYP.) 4" MIN. 1'-8" 1'-4" 1'-4" 1'-8" 8" 1'-4" 1'-4" 24" (MAX.) TYP. GEOTEXTILE FABRIC WRAPPED AROUND HAY BALES, AS SHOWN ABOVE 2" x 2" HARDWOOD STAKES OR RE-BARS DRIVEN FLUSH WITH BALE; 2 STAKES PER BALE REQUIRED, ONE VERTICAL, ONE ANGLED OVERLAP FABRIC @ STAKE 1 EC1 SEDIMENT CONTROL BARRIER (SHEET FLOW) SCALE: N.T.S. TYPICAL TIE POINTS STEEL OR 2" x 2" HARDWOOD POSTSGEOTEXTILE FABRIC MEETING NYSSSESC SPECIFICATIONS SECURELY FASTEN WIRE FENCE TO POSTS & FABRIC TO FENCE STEEL OR HARDWOOD POST GEOTEXTILE FABRIC 4"x6" TRENCH WITH COMPACTED BACKFILL GEOTEXTILE FABRIC 3 4" (MIN.) DRAIN ROCK (IF REQUIRED) SAND BAGS LAID TIGHT END TO END, PERPENDICULAR TO DIRECTION OF FLOW HARD SURFACE WOVEN WIRE FENCE 4' MIN.B 4' MIN. DIKE CONSTRUCTED USING CRUSHED STONE AND LIGHT RIP RAP ORIGINAL GRADE NON-WOVEN GEOTEXTILE FABRIC LIGHT RIP RAP (TYP.) FLOW NOTES: 1) THIS DETAIL IS APPLICABLE TO SHEET FLOW DRAINAGE ON A TEMPORARY OR SEMI-PERMANENT BASIS (1 YEAR MAXIMUM) FOR EROSION CONTROL. 2) SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY. 3) ALL MATERIALS AND INSTALLATION SPECIFICATIONS SHALL BE AS FOUND IN THE LATEST VERSION OF THE NYSSSESC. 4) INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT AS NEEDED; 9" (MAX.) RECOMMENDED STORAGE HEIGHT. 5) REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL NOT CONTRIBUTE SEDIMENT OFF-SITE AND CAN BE PERMANENTLY STABILIZED. 6) DETAIL SHOWN IS EQUIVALENT TO A "REINFORCED" SILT FENCE. REFERENCES MADE TO "STANDARD" AND "SUPER" SILT FENCE, SEE NYSSSESC. SHEET FLOW BARRIER DEVICE SYMBOL: BUTT BALES TOGETHER, I.E.: NO GAP SHEET FLOW DRAINAGE BEDDING DETAIL FLOW (CONTRACTOR MAY USE ANY OF DETAILS SHOWN ABOVE FOR SEDIMENT CONTROL OF SHEET FLOW ONLY) (CONTRACTOR MAY REFER TO NEW YORK STANDARDS AND SPECIFICATION FOR EROSION AND SEDIMENT CONTROL "BLUE BOOK" FOR OTHER METHODS OF EROSION AND SEDIMENT CONTROL (CONTACT ENGINEER PRIOR TO MAKING SUBSTITUTIONS) NOTES: 1) THESE DETAILS ARE APPLICABLE TO SHEET FLOW DRAINAGE ON DISTURBED SOILS, HAY BALE DIKES ARE NOT SUITABLE FOR STREAM CHANNELS. 2) HAY BALE DIKES MAY BE USED FOR TEMPORARY (180 DAYS MAXIMUM) EROSION CONTROL. FLOW SAND BAGS SILT FENCE STRAW BALE DIKE A 1 FLOW NOTES: 1) THIS STRUCTURE IS SUITABLE FOR EROSION CONTROL OF SHEET FLOW DRAINAGE ON MODERATE SLOPES, OR AS A CHECK DAM SEDIMENT TRAP IN A DRAINAGE DITCH; IF USED AS A CHECK DAM, PROVIDE OVERFLOW CAPABILITY. 2) "A" TO BE 2 OR GREATER FOR TEMPORARY DIKES AND 2.5 OR GREATER FOR PERMANENT EARTH DIKES. 3) "B" TO BE HEIGHT SHOWN ON PLAN OR EQUAL TO HEIGHT OF ADJOINING GROUND OR MAXIMUM 18" HIGH. 4) SEDIMENT TO BE REMOVED WHEN 25% OF THE DIKE'S FUNCTIONAL VOLUME HAS BEEN LOST. 5) DIKES TO BE REMOVED AND AREAS STABILIZED WITH AN APPROPRIATE VEGETATION THAT MATCHES SURROUNDING AREAS AND MULCHED TO PREVENT EROSION. FLOW STONE / EARTH DIKE (CONTRACTOR MAY USE THE DETAIL SHOWN ABOVE FOR SEDIMENT CONTROL FOR CONCENTRATED FLOWS) (CONTRACTOR MAY REFER TO NEW YORK STANDARDS AND SPECIFICATION FOR EROSION AND SEDIMENT CONTROL "BLUE BOOK" FOR OTHER METHODS OF EROSION AND SEDIMENT CONTROL (CONTACT ENGINEER PRIOR TO MAKING SUBSTITUTIONS) EROSION & SEDIMENT CONTROL: ESC-1) LAND DISTURBANCE IS DEFINED AS DISRUPTION OF ESTABLISHED GROUND COVER/SOIL, AND NO LAND DISTURBANCE SHALL TAKE PLACE UNLESS PROVISIONS ARE IN PLACE TO CONTROL EROSION AND SEDIMENTATION. LAND DISTURBANCE SHALL NOT EXCEED LIMITS SHOWN ON DRAWING WITHOUT APPROVAL OF THE PERMITTING AUTHORITY. ESC-2) FROM DAY 1 OF CONSTRUCTION UNTIL FINAL SITE STABILIZATION, ALL EARTHWORK SHALL BE CONTROLLED TO PREVENT EROSION & SEDIMENTATION IN ACCORDANCE WITH PROVISIONS SHOWN ON THESE PLANS AND THE "NEW YORK STATE STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL" (NYSSSESC), ISSUED BY THE NYSDEC, LATEST EDITION. ALL ESC DEVICES SHALL BE MAINTAINED IN ACCORDANCE TO THE NYSSSESC. EROSION CONTROL OPTIONS INCLUDE: A) GRADE DISTURBED AREA AND SEED (TEMPORARY OR PERMANENT) IMMEDIATELY AFTER CURRENT WORK IS COMPLETED OR TEMPORARILY SUSPENDED, B) MULCH WITH STRAW, BARK MULCH, STONE, ETC., C) APPLY EROSION CONTROL MATTING, OR D) OTHER, AS APPROVED. ESC-4) FROM DAY 1 OF CONSTRUCTION UNTIL FINAL SITE STABILIZATION, SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED IN FULL OPERATIVE CONDITION UNTIL PERMANENT SITE STABILIZATION IS COMPLETE AND PERMANENT GROUND COVER ESTABLISHED AS DEFINED BY NYSDEC STANDARDS. ESC-5) FOR PROJECTS IN THE LAKE GEORGE BASIN: ESC-5A) WITHIN 500 FEET OF THE MEAN HIGH WATER OF ANY LAKE, POND, RIVER, STREAM, OR WETLAND, NO LAND AREA, INCLUDING AREAS STOCKPILED WITH EARTHEN MATERIALS, WHICH HAS BEEN CLEARED MAY BE MADE OR LEFT DEVOID OF GROWING VEGETATION FOR MORE THAN 24 HOURS WITHOUT A PROTECTIVE COVERING SECURELY PLACED OVER THE ENTIRE AREA AND/OR EROSION CONTROL DEVICES PROPERLY INSTALLED TO PREVENT SEDIMENTS FROM ENTERING THE WATER BODY. ACCEPTABLE PROTECTIVE COVERINGS INCLUDE NATURAL MULCH OF A DEPTH OF TWO INCHES, ROCK RIP-RAP, NON-DEGRADABLE MATERIALS SUCH AS PLASTIC OR CANVAS COVERINGS, AND IMPERVIOUS STRUCTURES. ESC-5B) IN AREAS WHERE SOIL DISTURBANCE ACTIVITY HAS BEEN TEMPORARILY OR PERMANENTLY CEASED, TEMPORARY AND/OR PERMANENT SOIL STABILIZATION MEASURES SHALL BE INSTALLED AND/OR IMPLEMENTED WITHIN SEVEN (7) DAYS FROM THE DATE THE SOIL DISTURBANCE ACTIVITY CEASED. THE SOIL STABILIZATION MEASURES SELECTED SHALL BE IN CONFORMANCE WITH THE MOST CURRENT VERSION OF THE TECHNICAL STANDARDS, NEW YORK STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL, AND IN THE LAKE GEORGE BASIN SHALL BE IN ACCORDANCE WITH LGPC REGULATION 646-4.15(C). ESC-5C) GROUND CLEARING OR GRADING ACTIVITIES WHICH OCCUR DURING THE PERIOD OCTOBER 15TH TO APRIL 15TH, DURING WHICH GERMINATION OF VEGETATION TYPICALLY WILL NOT TAKE PLACE, SHALL BE REQUIRED TO INCORPORATE EXTRA MEASURES DURING REVEGETATION IN ORDER TO REDUCE EROSION AND MAINTAIN WATER QUALITY. THESE EXTRA MEASURES INCLUDE, BUT ARE NOT LIMITED TO, THE USE OF SCREEN MESH, NETTING, EXTRA MULCH, AND SILTATION FENCES. ESC-6) ALL CONSTRUCTION ACTIVITY SHALL STOP IF EROSION AND/OR SEDIMENTATION IS EVIDENT, INCLUDING IF IN PLACE CONTROLS ARE DAMAGED OR DESTROYED OR ARE INADEQUATE. CONSTRUCTION ACTIVITY SHALL NOT RESUME UNTIL SUCH TIME AS CONTROLS ARE IN PLACE TO PREVENT FURTHER ENVIRONMENTAL IMPACT AND UNTIL SUCH TIME AS THE PRIOR IMPACT IS REMEDIATED. ESC-7) DETAILS SHOWN ON THIS DRAWING ARE ONLY EXAMPLES OF APPLICABLE EROSION AND SEDIMENT CONTROL SYSTEMS; CONTRACTOR TO DETERMINE "BEST MANAGEMENT PRACTICE(S)" AND SUBMIT TO OWNER/ ENGINEER FOR APPROVAL. EARTHWORK & TURF ESTABLISHMENT: ET-1) ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION UNLESS OTHERWISE DIRECTED ON THESE PLANS OR BY OWNER.FOR AREAS OF SITE THAT HAVE SEEN VEHICULAR TRAFFIC, SOILS RESTORATION TO BE AS FOLLOWS: SOILS RESTORATION REQUIREMENTS AS DEFINED IN CHAPTER 5.1.6 OF "NEW YORK STATE STORMWATER DESIGN MANUAL": APPLICATION OF 3" OF COMPOST, TILLING COMPOST INTO SUB-SOIL A MINIMUM DEPTH OF 12". APPLICATION OF TOPSOIL TO A DEPTH OF 6". VEGETATE AS REQUIRED PER LANDSCAPING PLAN, IF APPLICABLE, OR AT THE DIRECTION OF OWNER. ET-2) TOPSOIL, PLANT/SEED, AND MULCH DISTURBED AREAS TO ESTABLISH PERMANENT VEGETATIVE GROWTH (GRASS OR OTHER NATIVE/NATURALIZED GROUNDCOVERS); CONTACT OWNER AND/OR LOCAL SOIL CONSERVATION SERVICE FOR RECOMMENDED MATERIALS AND APPLICATION. ET-3) CONTRACTOR TO PROTECT EXISTING STRUCTURES & PERSONAL PROPERTY DURING WORK. WHERE POSSIBLE, ROUTE VEHICLES AND COMPLETE ALL WORK OUTSIDE OF ROOT ZONES OF MAJOR TREES AND AROUND OTHER FEATURES, AS PRACTICAL AND AS DIRECTED BY OWNER. ET-4) NO CLEARING OR GRUBBING BEYOND THE CLEARING LIMITS LABELED SHALL OCCUR UNLESS APPROVED IN ADVANCE BY ENGINEER AND PERMITTING AUTHORITY(IES). COMPOST FILTER SOCK 2"X2" WOODEN STAKES PLACED AT 10' O.C. MAX. SPACING 8' EXISTING CONTOURS 2"X2" WOODEN STAKES PLACED 10' O.C. 1' MIN. COMPOST FILTER SOCK PER NYSSSESC FLO W F L O W 102 101 100 WIDTH: 12'-24' (SEE NOTE) 1.) COMPOST FILTER SOCKS WILL BE PLACED ON THE CONTOUR WITH BOTH TERMINAL ENDS OF THE SOCK EXTENDED 8 FEET UP SLOPE AT A 45 DEGREE ANGLE TO PREVENT BYPASS FLOW. 2.) DIAMETERS DESIGNED FOR USE SHALL BE 12"-32" EXCEPT THAT 8" DIAMETER SOCKS MAY BE USED FOR RESIDENTIAL LOTS TO CONTROL AREAS LESS THAN .25 ACRES. 3.) COMPOST SOCKS SHALL BE ANCHORED IN EARTH WITH 2" X 2" WOODEN STAKES DRIVEN 12" INTO THE SOIL ON 10 FOOT CENTERS ON THE CENTERLINE OF THE SOCK. 4.) THE MAXIMUM SLOPE LENGTH ABOVE A COMPOST FILTER SOCK SHALL NOT EXCEED THE FOLLOWING LIMITS DITCH STABILIZATION GUIDELINES (GUIDELINES ARE PROVIDED TO OFFER ALTERNATIVES FOR STABILIZATION, AS NEEDED; ADDITIONAL OR MORE AGGRESSIVE TREATMENTS MAY BE NECESSARY DEPENDING ON SITE CONDITIONS) DS-1) 0-6%: SEED & MULCH DS-2) 6-10%: SEED & MULCH W/ TEMPORARY EROSION CONTROL MATTING (EX. NORTH AMERICAN GREEN MODEL: P300 OR APPROVED EQUIVALENT) DS-3) 10-15%: SEED & MULCH W/ TEMPORARY OR PERMANENT EROSION CONTROL MATTING (EX. NORTH AMERICAN GREEN MODEL: C350 OR APPROVED EQUIVALENT) DS-4) 15%+: SEED & MULCH W/ PERMANENT EROSION CONTROL MATTING (EX. NORTH AMERICAN GREEN MODEL: P550 OR APPROVED EQUIVALENT) OR OTHER APPROVED MEASURES (STONE CHECK DAMS AND/OR RIP RAPPED CHANNEL) SLOPE STABILIZATION GUIDELINES (GUIDELINES ARE PROVIDED TO OFFER ALTERNATIVES FOR STABILIZATION, AS NEEDED; ADDITIONAL OR MORE AGGRESSIVE TREATMENTS MAY BE NECESSARY DEPENDING ON SITE CONDITIONS) SS-1) 0-25%: SEED & MULCH SS-2) 25-33%: SEED & MULCH W/ TEMPORARY EROSION CONTROL MATTING (EX. NORTH AMERICAN GREEN MODEL: S75BN OR APPROVED EQUIVALENT) SS-3) 33-50%: SEED & MULCH W/ TEMPORARY OR PERMANENT EROSION CONTROL MATTING ON SLOPES (EX. NORTH AMERICAN GREEN MODEL: S150BN OR APPROVED EQUIVALENT) SS-4) 50-100%: SEED & MULCH W/ PERMANENT EROSION CONTROL MATTING ON SLOPES (EX. NORTH AMERICAN GREEN MODEL: SC150BN OR APPROVED EQUIVALENT) SS-5) 100%+: CONTACT ENGINEER FOR GUIDANCE. DIAMETER (IN.) SLOPE% 2 5 10 20 25 33 50 8 225*200 100 50 20 -- 12 250 225 125 65 50 40 25 18 275 250 150 70 55 45 30 24 350 275 200 130 100 60 35 32 450 325 275 150 120 75 50 GEOTEXTILE: PLACED OVER ENTIRE AREA TO BE COVERED WITH AGGREGATE (SEE NOTES) EROSION & SEDIMENT CONTROL CONSTRUCTION NOTES: 1) CONTACT PERMITTING AUTHORITIES REGARDING CONSTRUCTION START DATE, AND ENGINEER TO SCHEDULE A PRE-CONSTRUCTION MEETING, PRIOR TO START OF CONSTRUCTION. 2) EROSION & SEDIMENT CONTROL TO BE INSTALLED PRIOR TO ANY OTHER CONSTRUCTION. 3) NYSDEC TRAINED PERSONNEL IN EROSION AND SEDIMENT CONTROL SHALL INSPECT SITE DAILY AND MAINTAIN LOG/REPORT BOOK. (NEW YORK STANDARDS AND SPECIFICATION FOR EROSION AND SEDIMENT CONTROL "BLUE BOOK" CAN BE FOUND AT: http://www.dec.ny.gov/chemical/29066.html OTHER ENVIRONMENTAL CONTROLS: 1.) PROTECT SITE DURING CONSTRUCTION IN ACCORDANCE WITH NYSDEC STORMWATER DESIGN MANUAL AND NYS EROSION & SEDIMENT CONTROL GUIDLINES ("BLUE BOOK"); LATEST EDITION 2.) TEMPORARY FUEL TANKS SHALL BE PROVIDED WITH SECONDARY CONTAINMENT EQUAL TO 100% OF TANK CONTENTS; AND AREA UNDER FUEL LINES SHALL BE COVERED IN WOODCHIPS, ABSORBENT MATTING, OR OTHER APPROVED ABSORBENT MATERIALS. COMPOST FILTER SOCK WOVEN WIRE FENCE (MIN. 14 GAUGE W/ MAX. 6" MESH SPACING) ON REINFORCED SILT FENCE * LENGTH IN FEET CONSTRUCTION ENTRANCE SPECIFICATIONS CS-1) AGGREGATE: A) STONE SIZE - USE #3 OR #4 (1"-4") STONE OR RUBBLE. B) THICKNESS: NOT LESS THAN 6". CS-2) LENGTH: A) TYPICAL COMMERCIAL/INDUSTRIAL ENTRANCE LENGTH= RECOMMENDED 50' MIN. B) A SINGLE RESIDENCE LOT ENTRANCE LENGTH= RECOMMENDED 30' MIN. CS-3) WIDTH: RECOMMENDED 12' MIN. WIDTH WITH SEPARATE ENTRANCE & EXITS TO SITE B) RECOMMENDED 24' MIN WIDTH WITH COMBINED ENTRANCE & EXITS TO SITE CS-4) GEOTEXTILE: A) TO BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING STONE. B) NOT REQUIRED ON A SINGLE FAMILY RESIDENCE LOT C) FABRIC SPECIFICATIONS: LIGHT DUTY ROAD= MIRAFI 100X OR APPROVED EQUIVALENT HEAVY DUTY ROAD= MIRAFI 600X OR APPROVED EQUIVALENT CS-5) SURFACE WATER: ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCE SHALL BE PIPED BENEATH THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES MAY BE CONSTRUCTED CS-6) MAINTENANCE: THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANING OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR DEPOSITED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY. CS-7) WASHING: WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC RIGHTS-OF-WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA OF STABILIZED STONE AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. CS-8) INSPECTION: PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN AGGREGATE: 6" THICK (SEE NOTE) 10' MIN. RADIUS (TYP.) LENGTH: 30'-50' (SEE NOTES) PU B L I C R O A D W A Y PROVIDE CONSTRUCTION ENTRANCE AS REQUIRED TO PREVENT TRACKING ONTO HIGHWAY. CONSTRUCTION ENTRANCE REV #DATE ISSUED / REVISIONS NOT FOR CONSTRUCTION ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED TRUE AND VALID ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED ENGINEER IS UNLAWFUL. 12 EAST WASHINGTON STREET GLENS FALLS, N.Y. COPYRIGHT Ó PLOTTED / REVISED: DRAWING: PHONE: (518) 792-2907 JARRETT En gineers, PLLC Civil & Environmental Engineering ENVIRONMENTAL CONTROLS EC1 ZEMANEK LOT LINE ADJUSTMENT PAUL ZEMANEK ELM DRIVE, GLEN LAKE QUEENSBURY, NEW YORK JANUARY 2024 PRO # 22003 SHEET: 9 OF 9 BASESHEET: 22 x 34 01/30/24 1:30 PM ROBERT U. HOLMES P.E. # 082026 202401/30/2024 A SUBMITTED TO THE TOWN OF QUEENSBURY FOR PERMITTING "DOCUMENTS PROVIDED IN SUPPORT OF THIS DESIGN MAY BE USED ONLY FOR THE USE SPECIFIED IN THE "ISSUE/REVISION" BLOCK ABOVE. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORATED IN ANY SUBSEQUENT DESIGN WORK, WITHOUT THE WRITTEN CONSENT OF RU HOLMES ENGINEERS, PLLC. ONLY DOCUMENTS LABELED AS "ISSUED FOR CONSTRUCTION" MAY BE USED FOR SAME. USER SHALL HOLD RU HOLMES ENGINEERS, PLLC HARMLESS AND DEFEND RU HOLMES ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." RU HOLMES Engineers, PLLC Civil & Environmental Engineering 12 EAST WASHINGTON STREET GLENS FALLS, NY PHONE 518-792-2907