INSPECTION WORKSHEET 03192024 (2) INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Complaint Number: Case Module: Permit Inspection Date: March 19, 2024 Inspection Status: Reinspect Inspector: Mark Smith Inspection Type: Framing Job Address: 78 MAIN ST , Parcel Number: Contact Type Company Name Name Primary Owner 78-80 Main Street LLC Foothills Builders Rucinski Hall Architecture Checklist Item Status Permit card visible from road Building Inspector notes 1/31/24 partial approval for framing -remaining sheer walls at third floor corridors, nailing pattern verified. 2/21/24 partial approval for framing - nail pattern at sheer walls second floor interior partitons verified. 2/27/24 partial approval for framing. - Nail pattern at sheer walls at second floor corridor verified. 3/19/24 partial approval for framing. - nail pattern at first floor sheer walls south end of building verified. PASS Framing PASS Ice and water shield 24 inches from wall PASS Jack Studs, headers and double jack studs 6' or greater PASS Truss Specification Provided on site PASS Bracing and bridging PASS Hurricane Clips and Uplift Screws all nail holes filled as per manufacturer PASS Jack Posts and Main Beams PASS Lag top plates and bottom plates of steel columns PASS Exterior sheeting nailed properly PASS Notches, Holes and Bearing Walls PASS Headroom 6 ft. 8 in. PASS Joist hangers PASS Metal Strapping for Notches Top Plate PASS Mark Smith Code Enforcement Officer