INSPECTION WORKSHEET 03182024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Complaint Number: Case Module: Permit
Inspection Date: March 18, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Rough Plumbing
Job Address: 4 TUTHILL RD
, Parcel Number:
Contact Type Company Name Name
Contractor Quality Builders
Owner N/A Denise Terrano
Owner N/A Steve Terrano
Architect Rucinski Hall Architecture
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
provide 3” into thermal envelope by 18” at the least. 3/13/24
PASSN/O
Rough plumbing, nail plates
provide nail plates
PASS
Plumbing vent, vents in place
PASS
3 inches vent through roof - 18 inches
minimum exposed
PASS
1 1/2 inch minimum drain size
N/O
Cleanout every 100 feet change of
direction
PASS
Drain and venting
PASS
Pressure test
PASS
Air or head test
PASS
5 psi or 10 ft. above highest connection
for 15 minutes
PASS
Water supply piping
PASS
Water supply piping pressure test
PASS
Water supply piping air or head test
PASS
50 psi for 15 minutes
PASS
Air test gas piping 10 psi for 10 minutes
N/O
All return air duct work must be hard
piped
PASS
Duct work sealed properly
PASS
Charles Dyer
Code Enforcement Officer