Inspection Report (11-15-2021) IIIII IIIII IIII IIIIIIII IIIIIIIIIII IIIIIIIIIIIIIII IIIIIII llllllllllllllllllll 111111111 Illl IIII IIIII lull fill llllllll���1�1 ll`1�1 IIIIIIII fill IIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIUUII41 Ulllllllllllllllllllllllll lllllll44411111111 Illl IIIII III IIIII IIII IIII IIII ttl 1111 ��111 Ill II UI IIIII l llll� � l 111 I I II I I U IIIIIIIIIIIIIIII Ill 111 II II II � ( 1 I l UII II Illll��ll �t i
� 1
IIIII IIIIIIIIIII�IIIIIIIIIIIIII�IIIIIII�IIIIIIIIIIIIIIII��IIIIIIIIII�I����IIIII�IIIIII��IIIIIIIIIIII��IIIII����IIII����������IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�IIIIIIII�IIIII�IIIIIII��IIIIIIIIIIIII��IIIII�������IIII���IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�IIIII��������IIuu11111111����������IIIIIIIIIIIIIIIIIIII�IIUlllll IIIIIIIIIII��������IIIIIII�I���I��IIIII lllllllllllllllllll�llllllll�l�llllllll�l� lllllllllllll��lllllllll�llllllllllll���llll��m����������������������������������������������������
Case Number: RC-0309-2021 Case Module: Permit Management
Inspection Date: 11/15/2021 Inspection Status: Partial Pass
Inspector: Mark Smith Inspection Type: Building Foundation
Job Address: 23 Knolls Rd North Parcel Number: 253.3-1-15
Queensbury, NY 12804
Contact Type Company Name Name
Applicant Thomas Ormsby
Architect Peter Jensen
Granted Permission Thomas Ormsby
Primary Owner Thomas Ormsby
Annie Yund
Checklist Item Passed Comments
Building Inspector Notes False 10/5/21 footings approved
10/14/21 frost walls at rear of house approved
10/22/21 partial approval for foundation walls , provide a letter
from the architect approving the omission of the pilaster at the
east wall.
10/29/21 frost walls at garage approved, 2 rows of#4 rebar
continuous, vertical dowels at 48"on center.
11/1/21 partial approval for foundation damp proofing and footing
drains, south and east walls not completed, call for recheck when
ready
11/15/21 poly under slab with 6x6 welded wire mesh verified at
basement, remainder of foundation damp proofing and footing
drains verified.
Footing Drain Stone- 12 inch width True
PVC/Cast/Copper/Pex tubing False
Foundation/Wallpour True Frost walls at rear of house approved. One row of#4 rebar at top
of wall, #4 vertical dowels at 48"on center.
10/22/21 foundation walls approved
10/29/21 frost walls at garage approved, 2 rows of#4 rebar
continuous, vertical dowels at 48"on center.
Masonry Wall False
Footing Drain Stone-6 inches above footing True
Foundation Dampproofing True
11/1/21 partial approval for foundation damp proofing and footing
drains, south and east walls not completed, call for recheck when
ready
Plumbing Under Slab False
Foundation Waterproofing False
Footing Drain Daylight or Sump True
11/1/21 partial approval for foundation damp proofing and footing
drains, south and east walls not completed, call for recheck when
ready
March 27,2024 Page 1 of 2
IIIIIIIIII IIII IIIIIIII IIIIIIIIIII IIIIIIIIIIIIIII IIIIIII llllllllllllllllllll IIIllllll Illl IIII IIIII lull fill llllllll���11�11`�1�llllllll fill IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIII llllllll44111111111 IIII IIIII III IIIII IIII IIII IIII �111111 ��III Ill II UI I fill l llll� l l 111 I I II I I U IIIIIIIIIIIIIIII Ill 111
I I I I I i l l I l UI I I I IIII I��ti l l t 1 � I
1I mo I
IIIII IIIIII�����IIIIIII�IIIIIIIIIIIIII�IIIIIIIIIIIII��IIIIIIIIIIIIIIII��IIIIIIIIIIII�II�III���IIIII�11111���IIIIIIIIIIIIII��111111�����IIIIII��7777���Illllllll�illllllllllllllllllll�lllllllllllllll�lllllll�lllllllllll��lllllllllllll��lllll�������llllll��lllllllllllllllilllllllllllllllllllll����lllll 7777777��II���,111����������Illlllllllllllll�ll�lllylllll IIIIII�����IIIIIII»�������I�IIIIIIIII�I���I��IIIII���������IIIIIIIIIIIIIIIIIII�IIIIIIII�I��IIIIIIII����������IIIIIIIIIIII��IIIIIIIII�IIIIIIIIIIIIIIIII��IIIIIIIIIII����������������������������������������»»»»»»���
Checklist Item Passed Comments
Monolithic Slab False
Footings True 10/5/21 footings approved, 3 rows of#4 rebar continuous with
vertical dowels at 48"on center
Footing Drain stone-6 mil poly True
Piers False
Backfill Approval True
Rough Grade 6 inch drop within 10 ft. False
Foundation Insulation Interior/Exterior False
Reinforcement in Place False
Reinforcement in Place True 10/5/21 footings approved, 3 rows of#4 rebar continuous with
vertical dowels at 48"on center
Reinforcement in Place True 3 rows of#4 rebar continuous
Permit Card Visible From Road False
Poly Under Slab True
Footing Dowels or Keyway in place True #4 rebar at 48"on center with j hook
#4 rebar to top of wall 48"on center
March 27,2024 Page 2 of 2