Loading...
231736_022224_CYL_3495A3348 Route 208 • Campbell Hall, NY 10916 Phone (845) 496-1600 • Fax (845) 496-1398 NYC Lic No 43 1813 State Route 7 • Harpursville, NY 13787 Phone (607) 235-2006 • Fax (607) 235-2007 For all NYC projects, this report should be considered a DRAFT, unless it bears the seal and signature of the laboratory director.877 US-4 • Schuylerville, NY 12871 Phone (518) 372-4067 • Fax (518) 507-6113 1471 ST RT 9, Lake George NY Date 1471 ST RT 9 LLC 3/22/2024 231736 Client Project Project Code REPORT OF COMPRESSIVE STRENGTH TEST FIELD DATA Footings:Building interior spread footings:West interior spread footings (5) - placed from north to south Placement Location: Date Received in Lab: Water: Date Placed: Cyls Made Per: Time Made: Slump Air Content Air Temperature: Mix Temperature 2/22/2024 ASTM C31 03:00 PM 4.75 in. 7.6 % 38 °F 60 °F ATC/Sweet, Brian Field Data by: Mix Supplier: Ticket #: Mix Type: Cement: Coarse Agg #1: Fine Aggregate Admixture(s): Pallette Stone Corp, Saratoga Springs 15602 Other: 35000 Truck #:4908 Mix Design not on file at time of report (C143, T152,C1611) : (C231, T152) (C1064, T309) : Coarse Agg #2:Slag: Fly Ash: Micro Silica: Supplier Mix ID: 2/23/2024 Unit Weight (lbs/cu ft)(C138, T121) : COMPRESSIVE STRENGTH TEST RESULTS Specimen Type:4 x 8 Cylinder Test Method:ASTM C39/AASHTO T22 Spec PSI:3000 Lab # Fracture Type PSI Unit Wt. Area Sq In. Diam B In. Diam A In. Age Days Date TestedCure Type MPAFactor Capping Type Comp. Strength Total Load Lbs 3495 Moist Room 7 3.99 4.00 12.54 1.00 55850 Cone & Split 4450 30.70 145.54 N2/29/24 3496 Moist Room 28 3.97 3.99 12.46 1.00 58690 Cone & Split 4710 32.48 146.67 N3/21/24 3497 Moist Room 28 4.00 3.99 12.53 1.00 61530 Cone & Split 4910 33.86 145.34 N3/21/24 3498 Moist Room 28 4.00 4.00 12.59 1.00 62480 Cone & Split 4960 34.22 145.68 N3/21/24 3499 Moist Room 0 4.02 3.98 12.56 1.00 HOLD 145.29 3500 Moist Room 0 3.99 3.97 12.46 1.00 HOLD 145.31 Remarks:Initial Curing Method:Curing Box End Capping was completed per C1231 or C617, T231 (N-Neoprene, S-Sulfur, G-Grinding) Advance Testing Advance Testing Specimens transported by Specimens cast by Compressive strength results comply with specifications Reviewed by: Latest Strength Tests by: Thomas, Michael (022265 OFFICE: Schuylerville, NY Tested At PDF • Results noted on this report relate only to the items inspected or tested. • This report shall not be reproduced, except if full, without the prior written approval of Advance Testing Company. 1 1ofPage