INSPECTION WORKSHEET 03252024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0724-2023 Case Module: Permit Inspection Date: March 25, 2024 Inspection Status: Reinspect Inspector: Charles Dyer Inspection Type: Framing Job Address: , Parcel Number: Contact Type Company Name Name Contractor N/A Eric Williams Owner N/A DANIEL COURTNEY Checklist Item Status Permit card visible from road PASS Building Inspector notes PASS Framing PASS Ice and water shield 24 inches from wall PASS Attic Access 22 inch x 30 inch minimum with 30 inch head clearance if upper level finished off, attic access to be provided as discussed N/O Jack Studs, headers and double jack studs 6' or greater PASS Garage portal framing PASS Bracing and bridging PASS Hurricane Clips and Uplift Screws all nail holes filled as per manufacturer PASS Jack Posts and Main Beams PASS Lag top plates and bottom plates of steel columns N/O Exterior sheeting nailed properly PASS Notches, Holes and Bearing Walls N/O Headroom 6 ft. 8 in. PASS Joist hangers PASS Metal Strapping for Notches Top Plate N/O Charles Dyer Code Enforcement Officer