Loading...
INSPECTION WORKSHEET 03272024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0576-2023 Case Module: Permit Inspection Date: March 27, 2024 Inspection Status: Reinspect Inspector: Charles Dyer Inspection Type: Framing Job Address: , Parcel Number: Contact Type Company Name Name Owner N/A Justin Beach Owner N/A Catherine Beach Contractor Nims Outdoor Services Inc null null Checklist Item Status Permit card visible from road PASS Building Inspector notes for main roof only / ice and water barrier 2/27/24 remainder verified 3/27/24 verified dura rock board for wood burning unit N/O Framing provide draft stopping as discussed at floor trusses PASSN/O Ice and water shield 24 inches from wall main roof only PASS Less than 4:12 pitch install double layer of ice and water shield N/O Attic Access 22 inch x 30 inch minimum with 30 inch head clearance could not get to upper level of home due to safety issues. N/O Jack Studs, headers and double jack studs 6' or greater PASSN/O Garage portal framing PASSN/O Truss Specification Provided on site will need to provide truss specs for verification N/O Bracing and bridging PASSN/O Hurricane Clips and Uplift Screws all nail holes filled as per manufacturer PASSN/O Jack Posts and Main Beams PASSN/O Lag top plates and bottom plates of steel columns PASSN/O Exterior sheeting nailed properly PASSN/O Notches, Holes and Bearing Walls N/O Headroom 6 ft. 8 in. stairs not installed yet N/O Deck post beam connections must use hex head bolts N/O Joist hangers PASSN/O Metal Strapping for Notches Top Plate N/O Charles Dyer Code Enforcement Officer