INSPECTION WORKSHEET 03272024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0576-2023 Case Module: Permit
Inspection Date: March 27, 2024 Inspection Status: Reinspect
Inspector: Charles Dyer Inspection Type: Framing
Job Address:
, Parcel Number:
Contact Type Company Name Name
Owner N/A Justin Beach
Owner N/A Catherine Beach
Contractor Nims Outdoor Services Inc null null
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
for main roof only / ice and water barrier 2/27/24
remainder verified
3/27/24 verified dura rock board for wood burning unit
N/O
Framing
provide draft stopping as discussed at floor trusses
PASSN/O
Ice and water shield 24 inches from wall
main roof only
PASS
Less than 4:12 pitch install double layer
of ice and water shield
N/O
Attic Access 22 inch x 30 inch minimum
with 30 inch head clearance
could not get to upper level of home due to safety issues.
N/O
Jack Studs, headers and double jack
studs 6' or greater
PASSN/O
Garage portal framing
PASSN/O
Truss Specification Provided on site
will need to provide truss specs for verification
N/O
Bracing and bridging
PASSN/O
Hurricane Clips and Uplift Screws all nail
holes filled as per manufacturer
PASSN/O
Jack Posts and Main Beams
PASSN/O
Lag top plates and bottom plates of steel
columns
PASSN/O
Exterior sheeting nailed properly
PASSN/O
Notches, Holes and Bearing Walls
N/O
Headroom 6 ft. 8 in.
stairs not installed yet
N/O
Deck post beam connections must use
hex head bolts
N/O
Joist hangers
PASSN/O
Metal Strapping for Notches Top Plate
N/O
Charles Dyer
Code Enforcement Officer