Loading...
2024-0152 a;i_ - - Office Use Only ,..}.. ,; f SEPTIC VARIANCE Permit#: 2.0 — &I5 Z. APPLICATION Permit Fee:'-,, 1 CQ• — Town of Cigrcnstiury Invoice:`� 742 Bay Road,Queensbury,NV 12804 \�AO P:518-761-8256 www.queensburv.net Approvals: Submittal: 1 (one) original &8 copies of the completed application package PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL Section 1: . Contact Information: Property Owner(s): John A. Swan Jr & Carolyn J. Swarowner's Agent: Hutchins Engineering PLLC Address: 34 Rolling Hill Rd Address: 169 Haviland Rd Ridgefield, CT 06877 Queensbury, NY 12804 Phone#: Phone#: 518-745=0307 Email: jswanjr34@gmail:com Email: Iwdobie@hutchinsengineering.com Secti®n 2: 10 Site Information: 2 7 20Lt Li : 11.1 Rockhurst.Road TOWN ,,,� Tax ID#: 227.9-1-6 Site Address: , 1 C�tr ^I r 1 '31_311 n,,r: ;.'' '- L'RY Directions to Site: Cleverdale Rd, right=onto:Rockhurst Rd, house on West(left) side, 3 properties south of point Section 3: - Distance from well on property to septic system (if applicable) feet Section 4: Is.it possible to install a conforming septic system on this property? ❑Yes 0 No If YES, please explain and attach:a diagram: Section 5: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? ['Yes ❑ No If NO, please explain: all neighboring properties are on Lake Water Section 6: is the proposed system to be-installed under a parking area? Q Yes n:_No --_::Section 7: —__ -- Section of the Sanitary Sewage Ordinance from which you are seeking the variance(i.e. leaching system will be 89 ft. - fr-om well in lieu of required_100.ft.): see plans for variance summary -;peptic Variance Application - _ - _ _ - - . Revised december 2021 t." i %' '`Section 8: List the names, parcel addresses, and tax map numbers of all adjoining property.owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name Lorraine Dickinson Address . 113 Rockhurst Road Tax Map ID 227.9-1-7 South Name Ronald & Katherine Miller Address 107 Rockhurst Road - Tax Map ID 227.9-1-5 East Name Eric Cottrell Address . 112 Rockhurst Road Tax Map ID 227.9-1-10 West Name Lake George , Address Tax Map ID Section 9: OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 1-11 Rockhurst R. I/We realize that putting the well,septic tank or leaching system less than the required 1 OG feet from the shoreline & prop. linesnay increase the risk of pollution. - , Owner—Print Name: John A. Swan J, & Carol `'R'd n - Owner_._Signature: II.,.._. ILIW171 !IWr�i Date: 3 a 1i.5 2-if Section 10: _ i NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) --I/We do hereby relieve the Town of Queensbury from any li ities on the plumbing and septic system located at: . I/We realize that putting the well,septic tank or leaching system less than the required feet. from the may increase the risk.of pollution. Neighbor/Tenant—Print Name:- - _ --- - - -- - - __ _ - Neighbor/Tenant-Signature: Date: -_Septic Variance Application - - _ Revised tie-comber 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: John A. Swan Jr & Carolyn J. Swan Designates: Hutchins.Engineering PLLC g as agent regarding the Septic Variance for Site Address: 111 Rockhurst Road Tax Map#: 227.9-1 -6 Engineering Fee Disclosure:Applications may be referred to the Town consulting engineer for review of septic design,storm drainage, etc. as determined by.the.Town Board of Health. Fees for engineering review:services will be charged directly to theapplicant. . Authorization for Site Visits: By signing this page and submitting the application materials attached herein,the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. . - Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. .I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed.checklist::. - OWNER—PRINT NAME: John A. Swan Jr & Caro ►/ ' . Swan - f IfiII OWNER—SIGNATURE: /.. . - / i - , . DATE: i' :24-> 2- . -Lucas W. Doble, P.E. - :. _.. ". 'AGENT—PRINT NAME: - -AGENT—SIGNATU DATE: 3 Z7 Z —_Septic Variance Application = - Revised December 2021 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC Phone: (518)745-0307 • Fax: (518)745-0308 March 27, 2024 Town of Queensbury Town Board/ Local Board of Health � 742 Bay Road �is i,-� i Queensbury, NY 12804 D TLE tc°� ,r ;r; "ti-_:;, _j Re ; John A. Swan, Jr. & Carolyn J. Swan ' MAR 1-, ? ft/I1Iz7 i 111 Rockhurst Road;.Lake George, Queensbury (T) ,, Tax Map ID#: 227.9-1-6 TQ{��,,�� $ Dear_Supervisor Strough and.Town Board Members: ,`�L )DES Enclosed please find a septic variance submission package plan for a replacement enhanced treatment on-site wastewater treatment for our'clients John A. Swan, Jr. and Carolyn J. Swan for their residence at 111 Rockhurst Road on Sandy Bay, Lake:George. We are seeking several setback variances,for the new OSWTS components from the property lines as well as the shoreline. These requests are itemized on Sheet S3 of the project plans. The proposed OSWTS will consist of a FujiClean CE-5 enhanced treatment unit and effluent pump station, which will be situated on the lakeside of the home:due to the under-slab plumbing in the house. For the absorption field,"a new 13'W x 62'L conventional crushed stone absorption bed with two rows of 34" wide traffic-rated Infiltrator H-20 chambers will be constructed on the roadside of the parcel, along the easterly property line: Every,effort has been made to provide a high-quality enhanced treatment system and to minimize the requested variances. It is our opinion thatthe new enhanced OSWTS will provide substantial environmental improvements for the property and for the Lake. -.. We respectfully request that this item be placed on the board's agenda for the upcoming April 2nd meeting. Please contact me if you have any questions or if you require additional information. Best"Re ar Lucas W: Dobie; P.E. _ Associate/Partner—Design_Engineer - Cc John and Carolyn Swan Hutchins Engineering PLLC .__ -_; _: _" i'f' LWDobie@hutchin`isengineering.com "LP/ vw✓y DRAWING LIST SURVEY S 1 -EXISTING CONDITIONS ENGINEERING PLANS S2 - WASTEWATER SYSTEM PLAN S3 - WASTEWATER DETAIL SHEET Di011 g Safely. NewrYork El Call Before You Dig E] Wait The Required Time El Confirm Utility Response El Respect The Marks Dig With Care 800.962.7962 www.digsafelynevwyork.com Cover Sheet John A. Swan Jr. &I Caro ly n 1. Swan New Enhanced Treatment On�site Wastewater Treatment Sy tem 111 Rockhurst Road Sandy Bay iiiiiiiii Lake George Town of Queensbur34 Warren County New York State Tax Map # 227.9�1�6, Town Board / Local Board of Health Submission for Septic Variance March 27, 2024 227.9-1-6 2024-0152 Swan Jr, John 111 Rockhurst Rd Septic Variance/Alteration OWNERS & APPLICANTS John A. Swan, Jr. & Carolyn J. Swan 34 Rolling Hill Road Ridgefield, CT 06877 MAR 2 7 292173-01 John A. Swan, Jr. & Carolyn J. Swan 111 Rockhurst Rd Sandy Bay - Lake George arl D Steves Land Surveyors 189 Havil=d Road Queenebury, New York 12804 (518) 792-8474 New York Lie. No. 50135 Hutchins Engineering PLLC 169 Haviland Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fax G. Thomas Hutchins, P.E. Thomas R. Center Jr. P.E. Lucas W. Dobie, P.E. t 0 z m CL CL /PF O .. I/2 ca Lake NOTES: 1.) THIS MAP WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE OR AN UP TO DATE TITLE REPORT AND IS THEREFORE SUBJECT TO ANY STATEMENT OF FACTS SHOWN THEREON. 2.) PARCEL IS SUBJECT TO ANY EASEMENTS OF RECORD. 3.) THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY MADE IN ACCORDANCE WITH THE EXISTING CODE OF PRACTICE ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. 4.) THIS MAP IS COPYRIGHT (D 2023 VAN DUSEN $ STEVES LAND SURVEYORS. UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS VIOLATION OF SECTION 7209, SUBDIVISION 2, OF NEW YORK STATE EDUCATION LAW. 5.) DIMENSIONS BETWEEN PROPERTY LINES AND STRUCTURES ARE TO THE NEAREST HALF FOOT AND ARE FOR THE SOLE PURPOSE OF INTERPRETING THEIR CONFORMANCE WITH ZONING AND NOT INTENDED TO AID IN THE ESTABLISHMENT OR RETRACEMENT OF PROPERTY LINES. G.) CONTOURS SHOWN HEREON ARE REFERENCED TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD29). 7.) UNDERGROUND UTILITIES, IF ANY, ARE NOT SHOWN HEREON. 8.) THE SURVEYED PARCEL IS SUBJECT TO WHATEVER RIGHTS, TITLE OR INTEREST THE TOWN OF QUEENSBURY, THE COUNTY OF WARREN, AND THE PEOPLE Of THE STATE OF NEW YORK MAY HAVE TO MAINTAIN THE ROADS, AND TO WHATEVER RIGHTS, TITLE OR INTEREST THE TRAVELING PUBLIC MAY HAVE TO THE 13ED OF THE ROADS. I \ \ \epk a\ c DO k Legend IPF = Iron Pipe Found IRF = Iron Rod Found CIRF = Capped Iron Rod Found M.R. = Magnetic Reaction U.P. = Utility Pole = Overhead Utility Wire = Wood Fence S% Lands Now or Formerly of Lorraine Dickinson Book:1161 Page:58 227.9- I -7 Shed 78 o 049 35,E W , Lands Now or Formerly of Ronald Miller Book:1226 Page:88 227.9-1 -5 5/8" I RF ,ple Tree Top of Nad=33G.00' C.IRF (\j caj.51- Stone Dave INAIZA I RF C-n , U.P. NM I G Map References 1 Map of Rockhurst on Lake George Developed by How -Mac Developments, Inc. Dated: December 20, 1955 Revised: January 16, 1956 By: Leslie W. Coulter 2 Map of a survey of lands to be conveyed by Frank and Lorraine Lasak To Robt. P. Daly, James P. Daly & Betty J. Daly & WM.J. Godlewski & Kathleen A. Godlewski Dated: December 04, 1985 By: Coulter & McCormack 3 Map of lands belonging to Edward Farhart, D.D.S and Marie Farhart Dated: June 14, 1991 By: Coulter & McCormack 4 Map of a survey made for John and David Dickinson Dated: February 02, 2022 By: Van Dusen & Steves Land Surveyors Deed References Ronald A. Suen and Mary Ann Suen To John A. Swan, Jr. and Carolyn J. Swan Dated: January 23, 2015 Recorded on: January 27, 2015 Book:5107 Page:35 OIZ t2 o CO � e� o 0, kO 0 Q O z z Cr W r� V1 V L (z co I x co Date: July 27, 2023 Scale 1"=10' S-1 SHEET 1 OF 1 T 227.9- 1 -G SWAN D3241 I DWG. NO. 23- 1 G4 Lake Georv, e 111111 1 Sandy Bay PROP.ATU L STONE OR SEGMENTAL BLOCK W ALL TO CREATE LEVEL AREA AROUND TANKS, TOP OF WALL EL. 331 PROP. 4IA. PRECAST CONCRETE MANHOLE AS EFFLUENT PUMP STATION W 1 DUPLEX PUMPS POP. 4 PVC DR- 5 - EFFLUENT SEWER Dock PROP. EDIMENT CONTROL FENCE Deck above Dock PR P. FU31CLEA,% E-5 - NHANCED TREATMENT UNIT OUSE SEWER, 22 LFf INV.1 = 329.5 INV. 2 = 329 SEPTIC VARIANCE SUMMARY 1. ABSORPTION FIELD TO SHORELINE 100' REQUIRED 90'PROPOSED 1O' OF RELIEF REQUESTED 2. ABSORPTION FIELD TO HOUSE 20' REQUIRED 9'PROPOSED 11' OF RELIEF REQUESTED 3, ABSORPTION FIELD TO EASTERLY PROPERTY LINE 10' REQUIRED 1'PROPOSED 9' OF RELIEF REQUESTED 4. ABSORPTION FIELD TO SOUTHERLY PROPERTY LINE 10' REQUIRED 5'PROPOSED 5' OF RELIEF REQUESTED 5. FUJI CLEAN ETU TO SHORELINE 50' REQUIRED 32'PROPOSED 18' OF RELIEF REQUESTED 6. PUMP STATION TO SHORELINE 50' REQUIRED 32'PROPOSED 18' OF RELIEF REQUESTED 7. HOUSE SEWER TO SHORELINE 50' REQUIRED 35'PROPOSED 15' OF RELIEF REQUESTED 8. EFFLUENT SEWER TO SHORELINE 50' REQUIRED 34'PROPOSED 16OF RELIEF REQUESTED 9. FORCEMAIN TO SHORELINE 50' REQUIRED 35'PROPOSED 15' OF RELIEF REQUESTED 10. FORCEMAIN TO HOUSE 10' REQUIRED 5'PROPOSED 5' OF RELIEF REQUESTED 11, FORCEMAIN TO SOUTHERLY PROPERTY LINE 10' REQUIRED 6'PROPOSED 4' OF RELIEF REQUESTED 12. DISTRIBUTION BOX TO SOUTHERLY PROPERTY LINE 10' REQUIRED 6'PROPOSED 4' OF RELIEF REQUESTED Dig mAj Safely. NewOYork ® Call Before You Dig Wait The Required Time E3 Confirm Utility Response E3 Respect The Marks M Dig With Care 800-962.7962 www.digsafelynev.ryork.com 1 13 Rockhur5t Rd 227.9-1 -7 Lands Now or Formerly of Lorraine Dickinson Book:1161 Page:58 WASTEWATER SYSTEM LAKE FROM PLAN REFERENCE 1 WATER SUPPLY NEIGHBORING SITE SOILS DATA 1 TPAH 1 PARCEL 227.9-1-7 -113 ROCKHURST ROAD - PLAN REF 1 TEST PIT I 13'x24' 1 TP-IH - 811012022 BY TOM HUTCHINS, P.E. 1 STONE BED 0-6" - TOPSOIL 1 IN/CHAMBERS 1 6-48" - FINE & MEDIUM SAND WITH CONCRETE 1 I DEBRIS, BRICKS, ETC. FROM PREVIOUS 1 BUILDING. 1 1 NO BOUNDARY CONDITION TO 48" I Shed 1 1 BUNK D - / FORCEMAIN, PROVIDE 3-FT MIN. COVER & / +, ; N POSITIVE DRAINBACK ' o L N LAKE I ~ �W W N/ WATER SUPPLY window II I +I _ I N I IV P.L. SETBACK (W IW) s T YT 2 1 90' : ABSOPTION BED mf ` TO SHORELINE ane Tank 1 rpa55); Ir�u �PF 103. 77' N 78049'357/W / PROP. DISTRIBUTION BOX EPUTED K A ER W 1CONC. BAFFLE INTAKE W ATERIINEI NEW W x r6TL CRUSHED EXIST. SEPTIC TANK &PUMP STALTI Nf STONE ABSORPTION BED WIT (TO BE PUMPED, SACKFILLED & 2) ROWS OF t9) INFILTRATOR "-20 DECOMMISSIONED IN -PLACE) OPEN -BOTTOM GRAVELLESS CHAMBERS PER ROW DEEP HOLE TEST PIT NOTE: DUE TO THE UNKOWN LOCATIONS OF WE EXISTING ABSORPTION FIELD 8L UNDERGROUND UTILITIES, IT IS PROPOSED TO EXCAVATE A DEEP SOILS TEST AT THE TIME OF INITIAL SITE WORK TO VERIFY THAT THE T MINIMUM OF VERTICAL SEPARATION FROM THE BOTTOM OF THE NEW ABSORPTION BED TO THE GROUNDWALTER TABLE WILL BE MET. SOIL TESTING PERFORMED BY THIS OFFICE AT THE 3 NORTHERLY PROPERTIES DID NOT ENCOUNTER A GROUNDW ALTER ELEV ATION THAT PRECLUDED THE INSTALLATION OF CONVENTIONAL DEPTH ABSORPTION FIELDS. PT-2 - 1212212023 BY L.W. DOBIE, P.E. 0-10" - TOPSOIL, GRASS SURFACE 10"+ - RED -BROWN FINE & MEDIUM SAND STABILIZED PERCOLATION RATE: 20 MINUTES PER INCH REPUTED LAKE WATER SUPPLY 107 Rockhur5t Rd 227.9-1-5 Lands Now or Formerly of Ronald Miller Book:1226 Page:88 RO 1RF �8e"t)r� 51g I 5 I NOTE: NO VYELLS ARE VISIBLE WITHIN 100-FT OF PROP. ABSORPTION FIELD I I I UNKNOWN WASTEWATER SYSTEM I WASTEWATER SYSTEM PLAN SCALE: 1 "=10' GRAPHIC SCALE 5 0 2.5 5 10 20 ( IN FEET ) u P NM 16 IRF t TO BE REMOVED, r. OMPONENTS UNKNOWN) REPUTED LAKE WATER SUPPLY I WASTEWATER SYSTEM FROM PLAN REFERENCE 3 5 15'x30' STONE BED TP-1-1N TP-114 WASTEWATER SYSTEM FROM PLAN REFERENCE 4 I I I I I 1 14 Rockhur5t Rd 227.9-1 -9 Lands Now or Formerly of Carl & Michele Weiner Book:4226 Page:265 LAKE WATER SUPPLY WASTEWATER SYSTEM FROM PLAN REFERENCE 2 VERTICAL DATUM NEIGHBORING SITE SOILS DATA PARCEL 227.9-1-9 -114 ROCKHURST ROAD - PLAN REF 2 TEST PIT TP-1 - 811012022 BY TOM HUTCHINS, P.E. 0-4" - TOPSOIL/GRASS 4-60" - MIXED SAND & CONCRETE & BRICK DEBRIS FROM OLD HOTEL NO BOUNDARY CONDITION ENCOUNTERED NORTH AMERICAN VERTICAL DATUM OF 1929 (NGVD29) Garage 1 12 Rockhur5t Rd 227.9-1-10 Lands N/F of Eric K Cottrell B:1441 P:102 108 Rockhur5t Rd 227.9-1-11 Lands Now or Formerly of Kevin & Cheryl Theriault Book:5252 Page:74 REPUTED LAKE WATER SUPPLY LAKE WATER SUPPLY Lake George 111"arner Bay NEIGHBORING PLAN REFERENCES PARCEL 227.9-1— 7 — 113 ROCKHURST RD PARCEL 227.9-1-10 — 112 ROCKHURST RD TOWN OF QUEENSBURY PERMIT.• SEP-0582-2022 TOWN OF QUEENSBURY PERMIT 2005-601 "WASTEWATER SYSTEM PLAN PREPARED FOR LORRAINE W "REPLACEMENT SEPTIC SYSTEM FOR RICHARD & CYNTHIA DICKINSON TRUST" 113 ROCKHURST ROAD, TOWN OF SMITH 112 ROCKHURST ROAD, TOWN OF QUEENSBURY, QUEENSBURY, WARREN COUNTY, NEW YORK. DATED WARREN COUNTY, NEW YORK." DATED NOVEMBER 2005, AUGUST 4, 202Z LAST REVISED OCTOBER 20, 2022 LAST REVISED NOVEMBER 2005 PREPARED BY: NACE PREPARED BY HUTCHINS ENGINEERING PLLC ENGINEERING PC CIVIL ENGINEERS PARCEL 227.9-1-9 — 114 ROCKHURST RD PARCEL 227.9-1-11 — 108 ROCKHURST RD TOWN OF QUEENSBURY PERMIT.. SEP-0583-2022 TOWN OF QUEENSBURY PERMIT. 2007-007 "WASTEWATER SYSTEM PLAN PREPARED FOR CARL & "BASE MAP FROM: FROST ARCHITECTURE 108 ROCKHURST MICHELLE WEINER,- 114 ROCKHURST ROAD, TOWN OF ROAD, ELJEN SEPTIC DESIGN FOR BRET & ANDREA PEEK QUEENSBURY, WARREN COUNTY, NEW YORK, DATED TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK." AUGUST 4, 2022, LAST REVISED OCTOBER 20, 2022 DATED MARCH 17, 2006, LAST REVISED AUGUST 24, 2006 PREPARED BY HUTCHINS ENGINEERING PLLC PREPARED BY: KEITH R. MANZ, P.E. TAX MAP # 227.9-1-6 PR REV EW � ION .ant FOR C N N0 ISSUED FOR SEPTIC VARIANCES 312712024 No. Revisions Date MAP REFERENCE WASTEWATER SYSTEM PLAN BASE MAP INFORMATION FROM "MAP OF A SURVEY prepared for: MADE FOR JOHN A. AND CAROLYN J. SWAN," IN John A. Swan, Jr. & Carolyn J. Swan THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED JULY 27, 2023. PREPARED BY.• 111 ROckhurst Road an D u S e� Town of Queensbury, County of Warren, State of New York Ste & s Drawn: HKB/LWD Checked. LWD Scale. 1 "-10' Dote: 911212023 LanY' d Surveyors 169 Haviland Road 3' ALTERATION OF THIS DOCUMENT EXCEPT Queensbury, NY 12804 292173-01-52 169 Haviland Road Queensbury, New York 12804 BY A LICENSED PROFESSIONAL ENGINEER (518) 745-0307 Phone (518) 792-8474 New York Lic. No. 50135 IS A VIOLATION OF NYS EDUCATION LAW. HUtchin$ Engineering PLLC (518) 745-0308 Fax WASTEWATER SYSTEM DESIGN 4-BEDROOM RESIDENCE WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW — 110 GPD/BEDROOM SYSTEM DESIGN FLOW — 440 GPD PRETREATMENT TANK — FUJICLEAN MODEL CE-5 E.T.U. EFFLUENT PUMP STATION — 4—FT DIAMETER PRECAST CONCRETE MANHOLE BASE SECTION W/DUPLEX ALTERNATING PUMPS & DEMAND DOSING DESIGN APPLICATION RATE. 0.55 GPD/SF, BASED ON 16-20 MIN/IN PERCOLATION RATE ABSORPTION BED AREA REQ'D = (440 GPD)/(0.55 GPD/SF) = 800 SF ABSORPTION BED AREA TO BE PROVIDED = 13'x62' = 806 SF WITH TWO ROWS OF (9) H-20 34"W INFILTRATOR CHAMBERS PER ROW WASTEWATER SYSTEM FILL MATERIAL NOTES AFTER REMOVING ORGANICS, TOPSOIL & COMPACTED SOILS TO A DEPTH OF 2—FT BELOW NEW ABSORPTION BED, PLACE SYSTEM FILL OVER THE ENTIRE AREA OF PROPOSED ABSORPTION BED. "ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND OR SANDY LOAM WITH IN —PLACE PERCOLATION RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3" IN SIZE. LESS THAN 107. BY WEIGHT SHALL BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 157. OF THE MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE. ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT PRIOR TO INSTALLATION OF ABSORPTION TRENCHES. INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 13' WIDE X 30' LONG ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS. PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI—TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON —CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS. INSTALL POLYETHYLENE EXTENSION PRECAST CONCRETE RISER TO GRADE WITH TAMPER & CAST—IRON FRAME & RESISTANT ACCESS COVER COVER TO GRADE (NON —TRAFFIC AREAS) BALL VALVE, ONE PER PUMP INSTALL VALVES AND UNIONS SUCH THAT EITHER PUMP CAN BE ISOLATED AND REMOVED WITHOUT REQUIRING PIT ENTRY 1/4" PER FOOT MIN. SLOPE 2„ 4" PVC SDR-35EFFLUENT 4" PVC SCH-40 HOUSE SEWER SEWER MIN. SLOPE CHAMBER 1 CHAMBER 2 1/8" PER FOOT SEDIMENTATION A vAEROBIC CONTACT CHAMBER 3 CHAMBER FILTRATION CHAMBER AEROBIC CONTACT ILTRATIONCHAMBER INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED ° ALARM/ LAG PUMP ON 4" ° 59 d LEAD PUMP ON \;:� SYSTEM MATERIAL SPECIFICATIONS 34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER OPEN —BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY. HOUSE SEWER PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. EFFLUENT SEWER PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FORCEMAIN PIPING TO BE 2" HDPE SDR-11. MAINTAIN 3' MINIMUM COVER AND POSITIVE DRAINBACK TO PUMP STATION. ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON —WOVEN SEPARATION FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT. FILL MATERIAL FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED IN "FILL MATERIAL NOTES." TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD AREA. SEED AND ESTABLISH TURF. �NMIil I�il hil I�i1 1i�1 75" EFFECTIVE LENGTH AA INFILTRATOR H-20 CHAMBER PROFILE NTS CHAIN ON EA. PUMP TO TOP OF TANK TO ALLOW FOR FUTURE PUMP REMOVAL WITHOUT ENTERING TANK -2" TEE JOINS TWO PUMP DISCHARGES INTO ONE FORCEMAIN PUMP OFF VOLUME OF DOSE 16 MIN. PER NOTE ° d e Qa Iw IN 0 z u- 4" MIN. TOPSOIL, SEED, MULCH & (� ESTABLISH TURF 8" MIN. ITEM-4- GRAVEL SUBBASE 34" CHAMBER WIDTH INFILTRATOR H-20 CHAMBER SECTION NTS EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION. 2" MIN. DROP DISTRIBUTION BOX BETWEEN INVERTS TRANSITION TO 4" OUTSIDE OF D—BOX CONCRETE BAFFLE 2" MIN. USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 4" PVC SDR-35 SOLID 7PROVIDE SDR-11 FORCEMAIN HEADER TO MANIFOLD PIPING 3' MIN. COVER & 1/8" PER FOOT MIN SLOPE POSITIVE DRAINBACK TO PUMP STATION PUMP STATION NOTES SEAL ALL TANK OPENINGS WATERTIGHT. 2" SCH-40 PVC INSIDE WET WELL THROUGH WALL PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. GATE VALVE INSTALL DUPLEX, ALTERNATING, DEMAND DOSE CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION, SJE REDUCING TEE POINTED DOWNWARD RHOMBUS IFS SINGLE PHASE DUPLEX DEMAND DOSE WITH 1" BALL VALVE THROTTLED TO CONTROLLER. ALLOW TRICKLE DRAIN BACK INTO WETWELL INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH UNION (2)— LOCATE SUCH THAT UNION ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S CAN BE DISCONNECTED AND EACH INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.EC.) PUMP REMOVED WITHOUT TANK ENTRY REQUIREMENTS. FUJI CLEAN USA MODEL BALL CHECK VALVE NEW 4—FT DIAMETER \-12" OF 3/4-1-1/2" CE-5 ENHANCED PRECAST CONCRETE PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO TREATMENT UNIT DUPLEX (2) EFFLUENT PUMPS CRUSHED STONE MANHOLE BASE SECTION ALTERNATE PUMP DOSING AND TO PROVIDE AN 80 GAL MAINTENANCE CONTRACT NOTE FLOAT SWITCHES — INSTALL INSIDE PUMP PIT AS PUMP STATION DOSE IN LOCATION ACCESSIBLE PUMPS TO BE GOULDS MODEL 3885, WE05H 230V, SINGLE A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM WITHOUT PIT ENTRY PHASE, 35 GPM PUMP AT 30 FT TDH. OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED FOR SEMI—ANNUAL INSPECTION AND SERVICE OF THE FUJI CLEAN ENHANCED TREATMENT UNIT & PUMP STATION DETAIL VERIFY ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. FUJICLEAN CE-5 ENHANCED TREATMENT UNIT. 10'-0" 36" FENCE POST DRIVEN O.C. MAX. 16" INTO GROUND r��INIM�11 SILT STOP EMBED IN ('17n1IAll1 R" AA1�1 Dig PASafely. Newyork ® Call Before You Dig El Wait The Required Time ® Confirm Utility Response Ea Respect The Marks E3 Dig With Care ty 800-962-7962 www. d i gsaf el ynewyork.com 'FENCE POST T STOP EMBED IN )UND 8" MIN. DISTURBED GROUND IMBER HT 4" INLET Ak v INLET BAFFL�---_ I Iw 01 z 13' BED WIDTH 5' CHAMBER SPACING I w ' CROWN GRASSED PARKING AREA r-4" CROWN � _ CL C RECIRCULATION PIPE) LOW BAFFLE FLOW OPENING (TYP.) (CLEANING OPENING) B PLAN VIEW 20" ACCESS COVER 20" ACCESS COVER 20" ACCESS COVER (TYP)� (T'P)� (NP)� 8" 5'-24" 4' 08, 0 3 1 ill, / \ SECTION A -A VIEW pp'EL 00 FOn V1 W �ION Rcot�STP'Q� NET FOR ,— RECIRCULATION AIR LIFT PUMP ,—DISINFECTION CYLINDER (OPTIONAL) //-4" OUTLET PIPE JA EFFLUENT AIR LIFT PUMP "AIR INTAKE DISINFECTION CYLINDER (OPTIC 5'- 1@1 CHAMBER Volume (gal) Q1 Sedimentation Chamber 198 (2) Anaerobic Filtration Chamber 198 Q3 Aerobic Contact Filtration Chamber 95 ® Clarification Chamber 44 Q5 Disinfection Chamber 4 Total Volume 540 SPECIFICATIONS Anaerobic Media PP/PE Board Type Aerobic Media PVC / PP / PE Aerobic Media PP/PE Blower 2.8 cfm Tank FRP Piping PVC / PP / PE Access Covers Plastic / Cast Iron Disinfectant (Optional) Chlorine Tablets SECTION B-B VIEW FUJICLEAN CE-5 ETU DETAILS NTS TAX MAP # 227.9-1-6 ROADWAY iS COVER ENING YPE - MEDIA LATION PUMP MEDIA N ASSEMBLY