Loading...
INSPECTION WORKSHEET 04032024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0060-2023 Case Module: Permit Inspection Date: April 03, 2024 Inspection Status: Passed Inspector: Charles Dyer Inspection Type: Residential Final Job Address: 34 NACY RD , Parcel Number: Contact Type Company Name Name Contractor Relyea & Sons and Daughters LLC Architect Creative Concepts Home Plan Services, LLC N/A John Kempf Checklist Item Status Building Inspector notes PASS 4 inch min building number address visible from road PASS Chimney height, B vent, direct vent location N/O Chimney rain cap installed N/O Fresh air intake N/O Fresh air supply 3 feet from grade N/O 3 inch plumbing vent through roof, minimum 18 inches PASS Outside spigots have air gap N/O Roof complete PASS Exterior finish complete PASS Platform at all exterior doors N/O Handrail required with 4 or more risers PASS Guards at stairs, decks and patios 30 inches or more above grade N/O Guard at stairwell at 34 inches or more PASS Window guards req at less than 2' above floor and 6' above grade PASS Guard at deck and porches 36" or more in height N/O Handrail termination at newell post or wall PASS Interior and exterior handrails 34" to 38" high PASS Wood deck 2 feet or more from grade diagonal bracing required N/O 4 or more Deck Joist Ledger Connections starting 24" from each end N/O Deck ledgers to be bolted per code N/O Grade away from foundation sloping 6 inches in the first 10 feet N/O 6 inch clearance to sill plate from grade N/O Gas meter and or regulator shut off 12 inches min above grade N/O HVAC vent terminal 10 feet from lot line and openings N/O Dryer duct max length 35 feet or per manufacturer's instructions N/O Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight PASS Low flow toilet 1.3 gallon per flushing cycle PASS Safety glazing required within 5 feet of tub and shower N/O Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Attic access 22 inches x 30 inches minimum with 30 inch high clearance PASS Attic access insulation R-value must equal ceiling R- value PASS Attic access gasketed PASS Foam in basement and attics covered with thermal barrier N/O Knee wall and crawl space areas require 18 inches x 24 inches access N/O Pull down stairs boxed out and insulated N/O Crawl space and knee wall access insulated and gasketed N/O Bathroom fans required, if no window PASS All plumbing fixtures complete PASS Backflow preventors where required N/O Foundation insulation to basement floor N/O Energy sticker on elec. panel, R values and heating systems N/O All Hot Water Systems R 3 on 3/4 inches or larger piping N/O Furnace shut off within 30 ft. or within line of site N/O Oil furnace shut off at entrance to furnace area N/O Propane tank proper setback from property line or structure N/O Furnace and hot water heater operating N/O Low water shut off required for boiler N/O Pressure relief valve, heat trap, water temp 110 degrees or less N/O Pressure relief valve down spout within 6 inches of floor N/O Hot water drain pan to indirect waste N/O Encl. stairs sheetrock underside minimum ½ inch gypsum N/O Fin elect; energy saving light bulbs 90 percent PASS Arc fault breaker habitable spaces N/O Flex gas pipe bonding N/O As built septic system N/O Sewer dept. inspection sticker N/O Site plan or variance approval inspection N/O Flood plain certification, if required N/O Fuel Tanks above flood plain elevation N/O Buried fuel tanks anchored in flood zone N/O Ok to issue certificate of occupancy PASS Charles Dyer Code Enforcement Officer