INSPECTION WORKSHEET 04032024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0060-2023 Case Module: Permit
Inspection Date: April 03, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Residential Final
Job Address: 34 NACY RD
, Parcel Number:
Contact Type Company Name Name
Contractor Relyea & Sons and Daughters LLC
Architect Creative Concepts Home Plan Services, LLC
N/A John Kempf
Checklist Item
Status
Building Inspector notes
PASS
4 inch min building number address
visible from road
PASS
Chimney height, B vent, direct vent
location
N/O
Chimney rain cap installed
N/O
Fresh air intake
N/O
Fresh air supply 3 feet from grade
N/O
3 inch plumbing vent through roof,
minimum 18 inches
PASS
Outside spigots have air gap
N/O
Roof complete
PASS
Exterior finish complete
PASS
Platform at all exterior doors
N/O
Handrail required with 4 or more risers
PASS
Guards at stairs, decks and patios 30
inches or more above grade
N/O
Guard at stairwell at 34 inches or more
PASS
Window guards req at less than 2' above
floor and 6' above grade
PASS
Guard at deck and porches 36" or more
in height
N/O
Handrail termination at newell post or wall
PASS
Interior and exterior handrails 34" to 38"
high
PASS
Wood deck 2 feet or more from grade
diagonal bracing required
N/O
4 or more Deck Joist Ledger Connections
starting 24" from each end
N/O
Deck ledgers to be bolted per code
N/O
Grade away from foundation sloping 6
inches in the first 10 feet
N/O
6 inch clearance to sill plate from grade
N/O
Gas meter and or regulator shut off 12
inches min above grade
N/O
HVAC vent terminal 10 feet from lot line
and openings
N/O
Dryer duct max length 35 feet or per
manufacturer's instructions
N/O
Interior privacy doors and trim required
PASS
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
PASS
Low flow toilet 1.3 gallon per flushing
cycle
PASS
Safety glazing required within 5 feet of
tub and shower
N/O
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
PASS
Smoke Detectors are required on every
level and in every bedroom
PASS
Smoke Detectors are required outside
every bedroom area
PASS
Smoke Detectors have battery back up
PASS
Smoke detectors are interconnected
PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas
PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace) PASS
Attic access 22 inches x 30 inches
minimum with 30 inch high clearance
PASS
Attic access insulation R-value must
equal ceiling R- value
PASS
Attic access gasketed
PASS
Foam in basement and attics covered
with thermal barrier
N/O
Knee wall and crawl space areas require
18 inches x 24 inches access
N/O
Pull down stairs boxed out and insulated
N/O
Crawl space and knee wall access
insulated and gasketed
N/O
Bathroom fans required, if no window
PASS
All plumbing fixtures complete
PASS
Backflow preventors where required
N/O
Foundation insulation to basement floor
N/O
Energy sticker on elec. panel, R values
and heating systems
N/O
All Hot Water Systems R 3 on 3/4 inches
or larger piping
N/O
Furnace shut off within 30 ft. or within line
of site
N/O
Oil furnace shut off at entrance to furnace
area
N/O
Propane tank proper setback from
property line or structure
N/O
Furnace and hot water heater operating
N/O
Low water shut off required for boiler
N/O
Pressure relief valve, heat trap, water
temp 110 degrees or less
N/O
Pressure relief valve down spout within 6
inches of floor
N/O
Hot water drain pan to indirect waste
N/O
Encl. stairs sheetrock underside minimum
½ inch gypsum
N/O
Fin elect; energy saving light bulbs 90
percent
PASS
Arc fault breaker habitable spaces
N/O
Flex gas pipe bonding
N/O
As built septic system
N/O
Sewer dept. inspection sticker
N/O
Site plan or variance approval inspection
N/O
Flood plain certification, if required
N/O
Fuel Tanks above flood plain elevation
N/O
Buried fuel tanks anchored in flood zone
N/O
Ok to issue certificate of occupancy
PASS
Charles Dyer
Code Enforcement Officer