INSPECTION WORKSHEET 04082024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0315-2023 Case Module: Permit
Inspection Date: April 08, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Residential Final
Job Address: 7 Midnight Dr
, Parcel Number:
Contact Type Company Name Name
Engineer Cobble Court Engineering PLLC
Owner N/A Nadim Sheikh
Owner N/A Shamim Sheikh
Checklist Item
Status
Building Inspector notes
for one car garage / bathroom addition with bedroom extension
PASS
4 inch min building number address
visible from road
PASS
Chimney height, B vent, direct vent
location
N/O
Chimney rain cap installed
N/O
Fresh air intake
N/O
Fresh air supply 3 feet from grade
N/O
3 inch plumbing vent through roof,
minimum 18 inches
PASS
Outside spigots have air gap
N/O
Roof complete
PASS
Exterior finish complete
PASS
Platform at all exterior doors
PASS
Handrail required with 4 or more risers
N/O
Guards at stairs, decks and patios 30
inches or more above grade
N/O
Guard at stairwell at 34 inches or more
N/O
Window guards req at less than 2' above
floor and 6' above grade
N/O
Guard at deck and porches 36" or more
in height
N/O
Handrail termination at newell post or wall
N/O
Interior and exterior handrails 34" to 38"
high
N/O
Wood deck 2 feet or more from grade
diagonal bracing required
N/O
4 or more Deck Joist Ledger Connections
starting 24" from each end
N/O
Deck ledgers to be bolted per code
N/O
Grade away from foundation sloping 6
inches in the first 10 feet
PASS
6 inch clearance to sill plate from grade
PASS
Gas meter and or regulator shut off 12
inches min above grade
N/O
HVAC vent terminal 10 feet from lot line
and openings
N/O
Dryer duct max length 35 feet or per
manufacturer's instructions
N/O
Interior privacy doors and trim required
PASS
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
PASS
Low flow toilet 1.3 gallon per flushing
cycle
PASS
Safety glazing required within 5 feet of
tub and shower
PASS
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
PASS
Smoke Detectors are required on every
level and in every bedroom
PASS
Smoke Detectors are required outside
every bedroom area
PASS
Smoke Detectors have battery back up
PASS
Smoke detectors are interconnected
PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas
PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace)
PASS
Heat detector required in attached garage
PASS
Attic access 22 inches x 30 inches
minimum with 30 inch high clearance
PASS
Attic access insulation R-value must
equal ceiling R- value
PASS
Attic access gasketed
PASS
Foam in basement and attics covered
with thermal barrier
N/O
Knee wall and crawl space areas require
18 inches x 24 inches access
N/O
Pull down stairs boxed out and insulated
N/O
Bathroom fans required, if no window
PASS
All plumbing fixtures complete
PASS
Backflow preventors where required
N/O
Foundation insulation to basement floor
N/O
Energy sticker on elec. panel, R values
and heating systems
PASS
All Hot Water Systems R 3 on 3/4 inches
or larger piping
N/O
Duct work sealed properly
N/O
Intake openings for HVAC
N/O
Range Hood 400 or more cfm make up
air required
N/O
Blower door test certification
N/O
HRV or ERV installed per bedroom
requirements
N/O
Floor truss, draft stop required at 1,000
sq. ft. if basement is finished
N/O
Emergency egress window below grade
44 inches max from sill height from
basement floor
N/O
Furnace shut off within 30 ft. or within line
of site
N/O
Oil furnace shut off at entrance to furnace
area
N/O
Furnace and hot water heater operating
PASS
Low water shut off required for boiler
N/O
Pressure relief valve, heat trap, water
temp 110 degrees or less N/O
Pressure relief valve down spout within 6
inches of floor
N/O
Hot water drain pan to indirect waste
N/O
Encl. stairs sheetrock underside minimum
½ inch gypsum
N/O
1/2 inch Gypsum or House Wall and
Gable
PASS
20 minute fire door and self-closing
hardware
PASS
Seals on garage doors, esp. wood
PASS
Basement stairs closed rise greater than
4 inches
N/O
Basement wall insulation R- value verified
N/O
Basement egress: 5 s.f. window w/sill or
Bilco door
N/O
Jack posts in basement lagged at top and
bottom
N/O
Fireblocking at fl joist 80 s.f. or less
N/O
Garage floor pitched
PASS
1/2" Gypsum board req. in basement for
framing if 2" x 8" or TJI/Floor Trusses
N/O
Gas log in sealed or glass enclosure
N/O
Fin elect; energy saving light bulbs 90
percent
PASS
CSST/other piping in conduit if buried,if
required
N/O
Arc fault breaker habitable spaces
N/O
Flex gas pipe bonding
N/O
As built septic system
N/O
Sewer dept. inspection sticker
N/O
Site plan or variance approval inspection
N/O
Flood plain certification, if required
N/O
Fuel Tanks above flood plain elevation
N/O
Buried fuel tanks anchored in flood zone
N/O
Ok to issue temporary certificate of
occupancy
N/O
Ok to issue certificate of occupancy
PASS
Charles Dyer