Septic Evaluation Letter900 Route 146 Clifton Park, NY 12065 (P) 518.371.7621 edpllp.com March 7, 2024 Laura Moore Planner, Town of Queensbury 742 Bay Road Queensbury, NY 12804 Regarding: Evaluation of Existing Onsite Wastewater System 282 Cleverdale Road Dear Ms. Moore: EDP has reviewed the available information on the existing septic system located at 282 Cleverdale Road in the Town of Queensbury. The following is a summary of that information. • The septic system was designed in 2014 by Environmental Design Partnership, LLP with a 1,500 gallon precast concrete septic tank, 1,000 gallon duplex pump tank and five (5) Eljen GSF trenches at 32 LF each. The system has been designed for up to 5 bedrooms. • Record Drawings dated June 2018, by EDP LLP, indicate that the system was installed in general conformance with the original design plans. • EDP performed a site inspection in November 2023. During this site inspection a review of the wastewater system area and tanks indicated that there are no signs of failure and that the system is functioning as originally designed. From the review of the above-mentioned information and the available record plans from 2014-2018 it appears that the existing septic system meets all the required setbacks from buildings, property lines, water bodies and wells. The proposed house renovations will result in a total of five (5) bedrooms. The pre-existing design is for five bedrooms. Overall, the existing system appears to be in general conformance with the current Town of Queensbury regulations and appears to be in good working condition. There is no plan for any wastewater renovations during the construction process. Sincerely, Connor DeMyer Environmental Design Partnership