INSPECTION WORKSHEET 04042024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: CC-0728-2023 Case Module: Permit
Inspection Date: April 04, 2024 Inspection Status: Reinspect
Inspector: John O'Brien Inspection Type: Commercial Final
Job Address: 170 LUZERNE RD
, Parcel Number:
Contact Type Company Name Name
Primary Owner N/A Nick Carlino
Granted Permission N/A Nick Carlino
Checklist Item
Status
Building Inspector notes
2/29/24 Preliminary Commercial Final Inspection Not Approved see
punchlist of remaining items below.
1) All Kraft faced insulation above drop ceiling in front office area and 2nd
floor mechanical room wall and ceiling needs to be covered with FSK25
Foil paper. The foil paper has a 15 minute thermal rating. COMPLETE
2) Install all passage doors and remove residential door thresholds
throughout first and second floor of office to eliminate tripping hazards.
COMPLETE
3) Complete handicap bathroom.
4) In warehouse cover foil faced foam insulation with metal wall siding.
COMPLETE
5) Entry needs to be ramped with asphalt when paving is done out front.
Bring it up flush with door threshold and feather it out blending in with
parking area paving.
6) Provide a check writing counter in reception area no higher than 34”
can be a desk or something you attach to wall in reception area.
COMPLETE
7) Complete all fire marshal items. COMPLETE
8) Complete exterior finish outside of new window. COMPLETE
9) Install drop ceiling in front office and reception areas. COMPLETE
FAIL
Chimney and B vent, direct vent location
PASS
Chimney rain cap installed
PASS
Exterior finish of building
PASS
Step risers 7 inches max and treads 11
inches minimum
PASS
Doors 36 inches with Lever Handle and
or Panic Hardware, if required
Front entrance will be ramped up and feathered out when the asphalt
paving is done in May 2024.
FAIL
Exits At Grade Or Platform 36 inches (w)
x 44 inches (l)
Front entrance will be ramped up and feathered out when the asphalt
paving is done in May 2024.
FAIL
Floor Bathroom Watertight Other Floors
Okay
PASS
Pressure relief valve, heat trap and water
temp 110 deg or less
Hot water not turned on working on waterlines will recheck tomorrow.
FAIL
Pressure relief valve down spout within 6
inches of floor
PASS
Lag top plates and bottom plates of steel
columns
Gas furnace shut off
PASS
HVAC vent terminal 10 feet from lot line
and openings
PASS
HC toilet flush handle on open side of
water closet
PASS
HC side and rear grab bars 36 inches
above floor
PASS
HC vertical grab bar 18 inches minimum
high
PASS
HC vertical grab bar 39 inches from floor
and corner
PASS
HC rear grab bar 36 inches with 24
inches to open side
PASS
HC mirrors 40 inches above floor to
bottom of glass
PASS
HC sinks 34 inches above floor
PASS
Low flow toilet 1.3 gallons per flushing
cycle
PASS
HC bathroom signage
PASS
HC parking lot signage
Handicap Parking and No Parking Sign to be installed in May 2024 when
asphalt paving is done.
FAIL
HC parking striping
Handicap parking and parking lot striping to be completed after parking
lot asphalt paving is completed in May 2024
FAIL
Universal symbol of access displayed
FAIL
Handicapped service counters 34 inches
max from floor
PASS
Bollard Protection:4 feet on center, 3 feet
above ground, required in front of gas
meters
N/O
Final electrical and flex gas piping
bonded
PASS
Building number or tenant address on
building or drive
Bldg Access All Sides 20ft Drivable
Surface
PASS
Site plan or variance approval inspection
FAIL
Ok to issue temporary certificate of
occupancy
FAIL
Ok to issue certificate of occupancy
FAIL
John O'Brien
Director of Building & Codes