Loading...
INSPECTION WORKSHEET 04092024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: CC-0763-2023 Case Module: Permit Inspection Date: April 09, 2024 Inspection Status: Passed Inspector: Mark Smith Inspection Type: Commercial Final Job Address: 1054 State Route 9 , Parcel Number: Contact Type Company Name Name Contractor BBL Construction Services Owner N/A David Hannoush Checklist Item Status Building Inspector notes 3/22/24 final commercial inspection not approved. please address the items listed below and call for recheck when completed - Provide a letter of substantial completion from design architect stating the project was completed in accordance with the approved plans and specifications -Provide electronic as built drawings -Submit air balancing report -install 4” building numbers at the exterior of the building in a location that is visible from the road -Complete work at break room sink - Complete installation of cash wrap and display cases - install signage for handicapped parking as discussed on site. -Complete Fire Marshals items 4/9/24 final inspection for commercial tenant fit up approved, - all items listed above have been received/completed. approved for issuance of Certificate of Occupancy. N/O Chimney and B vent, direct vent location PASS 3 inches vent stack through roof - 18 inches minimum exposed existing PASSN/O Roof complete PASS Exterior finish of building PASS Grade Complete, 6 in 10ft or Equivalent PASS Stair rail 34 inches–38 inches high on both sides of stairway, 12 inches beyond top and bottom of stairs PASS Vestibules for exit doors greater than 3000 sq. ft PASS Doors 36 inches with Lever Handle and or Panic Hardware, if required PASS Exits At Grade Or Platform 36 inches (w) x 44 inches (l) PASS Gas Shut-off Exposed and Regulator 12 inches min above grade PASS Floor Bathroom Watertight Other Floors Okay PASS Pressure relief valve, heat trap and water temp 110 deg or less PASS Pressure relief valve down spout within 6 inches of floor PASS Gas furnace shut off PASS HVAC vent terminal 10 feet from lot line and openings PASS HC toilet flush handle on open side of water closet PASS HC side and rear grab bars 36 inches above floor PASS HC grab bar: 42 inches side, 12 inches from corner PASS HC vertical grab bar 18 inches minimum high PASS HC vertical grab bar 39 inches from floor and corner PASS HC rear grab bar 36 inches with 24 inches to open side PASS HC mirrors 40 inches above floor to bottom of glass PASS HC sinks 34 inches above floor PASS Low flow toilet 1.3 gallons per flushing cycle PASS HC bathroom signage PASS HC parking lot signage PASS HC parking striping PASS Universal symbol of access displayed PASS Public toilet room handicapped accessible PASS Handicapped service counters 34 inches max from floor PASS Final electrical and flex gas piping bonded PASS Building number or tenant address on building or drive PASS Bldg Access All Sides 20ft Drivable Surface PASS Engineer or architect approval PASS Electronic as builts PASS HVAC air balancing report PASS Ok to issue certificate of occupancy PASS Mark Smith Code Enforcement Officer