INSPECTION WORKSHEET 04112024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0619-2023 Case Module: Permit
Inspection Date: April 11, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Framing
Job Address: 1611 Bay Rd
, Parcel Number: 265.-1-43.2
Contact Type Company Name Name
Engineer N/A Daniel Ryan
Owner N/A Sarah Palladino
Contractor Cerrone Builders Inc
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
for ice and water barrier only 3/12/24
PASSN/O
Framing
provide air baffles at porch areas and garage
PASSN/O
Ice and water shield 24 inches from wall
PASS
Attic Access 22 inch x 30 inch minimum
with 30 inch head clearance
cut a 22”x30” at garage / girder truss where T05 trusses meet
PASSN/O
Jack Studs, headers and double jack
studs 6' or greater
PASSN/O
Garage portal framing
PASSN/O
Truss Specification Provided on site
PASSN/O
Bracing and bridging
PASSN/O
Hurricane Clips and Uplift Screws all nail
holes filled as per manufacturer
PASSN/O
Jack Posts and Main Beams
PASSN/O
Lag top plates and bottom plates of steel
columns
PASSN/O
Exterior sheeting nailed properly
PASSN/O
Notches, Holes and Bearing Walls
PASSN/O
Headroom 6 ft. 8 in.
stairs not installed
N/O
Joist hangers
PASSN/O
Metal Strapping for Notches Top Plate
PASSN/O
Charles Dyer
Code Enforcement Officer