Loading...
INSPECTION WORKSHEET 04112024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: CC-0013-2023 Case Module: Permit Inspection Date: April 11, 2024 Inspection Status: Failed Inspector: Mark Smith Inspection Type: Commercial Final Job Address: 78 MAIN ST , Parcel Number: Contact Type Company Name Name Owner 78-80 Main Street LLC Contractor Foothills Builders Architect Rucinski Hall Architecture Checklist Item Status Building Inspector notes 4/11/24 final inspection for mixed use building not approved, please address the items listed below and call for recheck when ready. - submit a letter of substantial completion from both the architect and structural engineer stating that the project was completed in accordance with the approved plans and specifications -each door at the rental apartments should be self closing and latch -verify hot water is operational -submit blower door test results for each apartment type and for the commercial space at first floor -all exposed steel at first floor ceilings will need to covered with 2 layers of 5/8 fire code Sheetrock. -complete Sheetrock at convenience store bathroom ceiling/ plumbing chase as discussed on site. -a second layer of 5/8 Sheetrock is required at the first floor front soffit, - complete fire caulking at first floor ceilings - a double layer of 5/8 Sheetrock is required or the bottom side of both stair ways. - a final inspection and sign off from zoning department will be required. -complete Fire Marshals items N/O Chimney and B vent, direct vent location Chimney rain cap installed 3 inches vent stack through roof - 18 inches minimum exposed Roof complete Exterior finish of building Grade Complete, 6 in 10ft or Equivalent Wood deck 2 feet or more from grade diagonal bracing required Interior and exterior guardrails 42 inches platforms and decks Interior and exterior balusters 4 inch max spacing platform and decks Stair rail 34 inches–38 inches high on both sides of stairway, 12 inches beyond top and bottom of stairs Step risers 7 inches max and treads 11 inches minimum Vestibules for exit doors greater than 3000 sq. ft Exterior lighting with daylight shut off Doors 36 inches with Lever Handle and or Panic Hardware, if required Exits At Grade Or Platform 36 inches (w) x 44 inches (l) Gas Shut-off Exposed and Regulator 12 inches min above grade Floor Bathroom Watertight Other Floors Okay Backflow preventers where required Pressure relief valve, heat trap and water temp 110 deg or less Pressure relief valve down spout within 6 inches of floor Hot water drain pan to indirect waste line Outside spigots have air gap Lag top plates and bottom plates of steel columns Boiler and Furnace Enclosures Fire Extinguishing System Low water shut off for boilers Gas furnace shut off HVAC vent terminal 10 feet from lot line and openings Oil furnace shut off at entrance to furnace area Propane Tank setbacks from property lines and structure Stockroom, storage, receiving and shipping room fire separation if required 3/4 hour corridor doors and closers Firewalls, 2 Hr, 3 Hr and fire dampers and fire doors Ceiling fire stopping, 3,000 sq. ft. wood frame Attic Access 30 inches x 20 inches x 30 inches (h) Pull down stairs boxed out and insulated Attic access gasketed Crawl space and knee wall access insulated and gasketed Attic access insulation R-value must equal ceiling R- value Foam in basement and attics covered with thermal barrier Smoke vents or fans, if required Hydraulic elevators non comb. shaft. Plumbing requirements for elevator pit Hydraulic Elevators oil separator required unless there is an alarm Elevator shaft sealed HC toilet flush handle on open side of water closet HC side and rear grab bars 36 inches above floor HC grab bar: 42 inches side, 12 inches from corner HC vertical grab bar 18 inches minimum high HC vertical grab bar 39 inches from floor and corner HC rear grab bar 36 inches with 24 inches to open side HC mirrors 40 inches above floor to bottom of glass HC sinks 34 inches above floor Low flow toilet 1.3 gallons per flushing cycle HC bathroom signage HC parking lot signage HC parking striping Universal symbol of access displayed Public toilet room handicapped accessible Handicapped service counters 34 inches max from floor HC Ramps that are 6 inches or more need handrails HC Ramps need 4 inches toe kick on each side of ramp HC Ramps need 12 inches extension at top and bottom HC Individual storage units, 5 percent of the total required Active listening system and signed assembly space Bollard Protection:4 feet on center, 3 feet above ground, required in front of gas meters Bollard Protection: 15 inch footings and 3 feet below grade Final electrical and flex gas piping bonded Occupancy sensor lighting control CSST and other piping in conduit if buried, if required Final survey As built septic system layout if required Public sewer sign off Building number or tenant address on building or drive Water fountain or cooler Handicapped water cooler installed Bldg Access All Sides 20ft Drivable Surface Engineer or architect approval Site plan or variance approval inspection Blower door test Elevator hoistways pressurized Electronic as builts HVAC air balancing report Special inspections Ok to issue temporary certificate of occupancy Ok to issue certificate of occupancy Mark Smith Code Enforcement Officer