INSPECTION WORKSHEET 04112024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0134 Case Module: Permit
Inspection Date: April 11, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Septic
Job Address: 985 State Route 149
Queensbury,NY 12804 Parcel Number: 266.3-1-78
Contact Type Company Name Name
Contractor N/A Rick McGuire
Engineer Environmental Design Partnership (EDP) null null
Owner ASAD Petroleum Inc
Checklist Item
Status
Building Inspector notes
4/11/24 partial approval of septic system.
- replacement absorption field and new D box only approved. forced main
not connected to system at this time.
absorption field consists of 9 laterals of pipe and stone at 100’ each.
N/O
Roof gutters don't discharge over leach
field
PASS
Soil type: loam
PASS
Type of water: municipal or well water
PASS
Waterline separation distance
PASS
Well casing length 50 ft. more or less
PASS
Total length of absorption fields
900’
PASSN/O
Septic system field above field plain
PASS
Sump pump not connected to septic
system
PASS
Septic tanks and pump station anchored
in flood zone PASS
Water softener not hooked to septic
system
PASS
Length of each trench
9 laterals at 100’ each, 900’ total.
PASSN/O
Depth of trenches
12/14”
PASS
System use status
system no completed at time of inspection
FAIL
Distance from building to tank
Distance from tank to d-box
Distance from d-box to field or pit
Opening sealed
End cap
PASS
Inlet outlet pipes and baffles, provide
extension collar if yes
N/O
Locations and separations
PASS
Distance from foundation to tank
N/O
Distance from foundation to absorption
field
N/O
Stone size
#2
PASS
Size of tank
N/O
50 percent alarm level activates
N/O
90 percent alarm level activates
N/O
Final electrical
Conforms as per plot plan
Engineer report and as-built
ETU Maintenance Contract provided
Location of system on property
Well separation distance
PASS
Mark Smith
Code Enforcement Officer