INSPECTION WORKSHEET 04222024 (2)
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0491-2023 Case Module:
Inspection Date: April 22, 2024 Inspection Status: Reinspect
Inspector: Charles Dyer Inspection Type: Foundation
Job Address: 4 TUTHILL RD
, Parcel Number:
Contact Type Company Name Name
Checklist Item
Status
Foundation Dampproofing
for modular foundation
PASSN/O
Backfill Approval
at modular foundation
4/22/24
PASSN/O
Footing Drain Stone - 6 inches above
footing
PASS
PVC/Cast/Copper/Pex tubing
N/O
Footing Drain Stone - 12 inch width
PASS
Footing Drain stone - 6 mil poly
PASS
Pressure Test
N/O
Air or head test
N/O
5 psi or 10 ft. above highest conn. for 15
minutes
N/O
Permit Card Visible From Road
PASS
Rough Grade 6 inch drop within 10 ft.
N/O
Foundation Insulation Interior / Exterior
at frost wall / walkout
PASS
Piers
PASS
Plumbing Under Slab
N/O
Foundation Waterproofing
N/O
Foundation / Wallpour
for frost wall with 2 rows #4 top and bottom 4/12/24
4/17/24 with 3 rows # 4 horizontally / verticals # 4 @ 4oc
PASS
Building Inspector Notes
4/11/24 for footings of single family dwelling
4/15/24 verified foam at frost wall / walkout
4/17/24 for foundation walls at main house
PASS
Poly Under Slab
N/O
Reinforcement in Place
with 2 rows #4 continuous
PASS
Footing Drain Daylight or Sump
PASS
Footings
frost blankets blown about, ground frozen at base of footings. 11/28/23,
call for recheck
Rechecked 11/29/23 OK to pour
4/11/24 footings for main house with 2 rows #4
PASS
Footing Dowels or Keyway in place
wet sticking with #4 dowels
4/11/24 wet sticking at SFD
PASS
Reinforcement in Place
2 rows #4 horizontally / #4 dowels 3' oc
PASS
Charles Dyer
Code Enforcement Officer