INSPECTION WORKSHEET 04172024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0144 Case Module: Permit
Inspection Date: April 17, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Rough Plumbing
Job Address: 15 Owen Ave
Queensbury,NY 12804 Parcel Number: 295.19-3-23
Contact Type Company Name Name
Owner N/A CHRISTOPHER DORE
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
4/17/24 partial approval for rough plumbing.
- plumbing for domestic water supply approved
- sanitary drains and vents approved
N/O
Rough plumbing, nail plates
PASS
Plumbing vent, vents in place
PASS
3 inches vent through roof - 18 inches
minimum exposed
PASS
1 1/2 inch minimum drain size
PASS
Shower liner test with 2 inches of water
Cleanout every 100 feet change of
direction
PASS
Drain and venting
PASS
Pressure test
Air or head test
5 psi or 10 ft. above highest connection
for 15 minutes
Water supply piping
Water supply piping pressure test
Water supply piping air or head test
50 psi for 15 minutes
Air test gas piping 10 psi for 10 minutes
All return air duct work must be hard
piped
Duct insulation- if required in unheated
spaces
Duct Blaster Test for duct work, minimum
R-8, unheated spaces
Duct work sealed properly
Mark Smith