INSPECTION WORKSHEET 04262024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0134 Case Module: Permit
Inspection Date: April 26, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Septic
Job Address: 985 State Route 149
Queensbury,NY 12804 Parcel Number: 266.3-1-78
Contact Type Company Name Name
Contractor N/A Rick McGuire
Engineer Environmental Design Partnership (EDP) null null
Owner ASAD Petroleum Inc
Checklist Item
Status
Building Inspector notes
4/11/24 partial approval of septic system.
- replacement absorption field and new D box only approved. forced main
not connected to system at this time.
absorption field consists of 9 laterals of pipe and stone at 100’ each.
4/22/24 unable to verify float switches at this time, septic tank was
pumped, secondary adsorption field has yet to be installed
4/26/24 partial approval for septic system
- secondary septic system approved, a second absorption field was
installed, 9 laterals at 100’ each with a valve to switch between the two
absorption fields. the approved plan states that every 6 months the
absorption field should be switched.
Provide as built drawing and letter of substantial completion from design
engineer for final approval.
PASSN/O
Roof gutters don't discharge over leach
field
PASS
Soil type: loam
PASS
Type of water: municipal or well water
PASS
Waterline separation distance
PASS
Well casing length 50 ft. more or less
PASS
Total length of absorption fields
900’
PASSN/O
Septic system field above field plain
PASS
Sump pump not connected to septic
system
PASS
Septic tanks and pump station anchored
in flood zone
PASS
Water softener not hooked to septic
system
PASS
Length of each trench
9 laterals at 100’ each, 900’ total.
PASSN/O
Depth of trenches
12/14”
PASS
System use status
system no completed at time of inspection
FAIL
Distance from building to tank
Distance from tank to d-box
Distance from d-box to field or pit
Opening sealed
PASS
End cap
PASS
Inlet outlet pipes and baffles, provide
extension collar if yes
N/O
Locations and separations
PASS
Distance from foundation to tank
N/O
Distance from foundation to absorption
field
N/O
Stone size
#2
PASS
Size of tank
N/O
50 percent alarm level activates
N/O
90 percent alarm level activates
N/O
Final electrical
Conforms as per plot plan
Engineer report and as-built
ETU Maintenance Contract provided
Location of system on property
Well separation distance
PASS
Mark Smith
Code Enforcement Officer