INSPECTION WORKSHEET 04292024 (2)
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0012-2024 Case Module: Permit
Inspection Date: April 29, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Rough Plumbing
Job Address: 6 NEIGHBORS WAY
, Parcel Number:
Contact Type Company Name Name
Owner N/A Richard Provenzono
Contractor Howland Construction
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
for replacing DWV
PASS
Rough plumbing, nail plates
PASS
Plumbing vent, vents in place
PASS
3 inches vent through roof - 18 inches
minimum exposed
PASS
1 1/2 inch minimum drain size
PASS
Washing machine trap: 18 inches-42
inches discharge
N/O
Cleanout every 100 feet change of
direction
N/O
Drain and venting
PASS
Pressure test
PASS
Air or head test
PASS
5 psi or 10 ft. above highest connection
for 15 minutes
PASS
Water supply piping
PASS
Water supply piping pressure test
PASS
Water supply piping air or head test
PASS
50 psi for 15 minutes
PASS
Charles Dyer
Code Enforcement Officer