Signed Inpsection Report (04-23-2024) Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road -(518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0737-2020 Case Module: Permit
Inspection Date: April 23, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Insulation
Job Address: 15 LUZERNE RD Parcel Number:
Contact Type Company Name Name
Architect Rucinski Hall Architecture
Hayes & Hayes LLC null null
Checklist Item Status
Building permit card visible from road PASS
4/23/24 insulation approved
Building Inspector notes N/O
Window Sealing PASS
.29
U Factors= .3 cfm for windows, .5 cfm for
doors PASS
zip R 6 sheathing with seams taped
Zip exterior sheathing, nailing &taping PASS
Proper or attic vent PASS
R 49 in ceilings R 21 in walls with zip R6 sheathing
Insulation installed as per ResCheck PASS
Duct work sealed properly, no duct tape PASS
Blower door test
Combustion Air Supply for Furnace PASS
Door or window perimeter spray foam
sealing PASS
Exterior wall outlets sealed PASS
Air Seal Outside Penetrations PASS
II Ductwork Sealed Return and Supply PASS
II return air duct work must be hard
piped PASS
Mark Smith
Code Enforcement Officer