INSPECTION WORKSHEET 04302024 (2) INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: CC-0013-2023 Case Module: Permit Inspection Date: April 30, 2024 Inspection Status: Reinspect Inspector: Mark Smith Inspection Type: Commercial Final Job Address: 78 MAIN ST , Parcel Number: Contact Type Company Name Name Owner 78-80 Main Street LLC Contractor Foothills Builders Architect Rucinski Hall Architecture Checklist Item Status Building Inspector notes 4/11/24 final inspection for mixed use building not approved, please address the items listed below and call for recheck when ready. - submit a letter of substantial completion from both the architect and structural engineer stating that the project was completed in accordance with the approved plans and specifications -each door at the rental apartments should be self closing and latch -verify hot water is operational -submit blower door test results for each apartment type and for the commercial space at first floor -all exposed steel at first floor ceilings will need to covered with 2 layers of 5/8 fire code Sheetrock. -complete Sheetrock at convenience store bathroom ceiling/ plumbing chase as discussed on site. -a second layer of 5/8 Sheetrock is required at the first floor front soffit, - complete fire caulking at first floor ceilings - a double layer of 5/8 Sheetrock is required or the bottom side of both stair ways. - a final inspection and sign off from zoning department will be required. -complete Fire Marshals items 4/26/24 final inspection for mixed use commercial building not approved, please address the items listed below -complete fire caulking at all penetrations at the ceilings at first floor rental spaces and common areas for apartment tenants. install rock wool at the top plates of the unsheetrocked walls in the rental space at the east end of the building. install fire caulking at the mechanical closet in the gym area duct work and ceiling penetrations -complete fire tape at rental space east end of building. - complete hook up of washers and dryers. -room 309, mini split is not working - room 210 bathroom room door does not close properly. -install permanent hand rails at each stair that extend past the top and bottom step 12” as discussed on site. - handicapped sinage should be installed at 60” to bottom of the sign. - complete Fire Marshal’s items - complete Zoning Department items. - submit electronic as built drawings all documentation requested has been received. 4/30/24 final inspection for mixed use commercial building approved for temporary Certificate of Occupancy only. please complete the items listed below for final approval - install permanent handrails at each stair well the extend 12” past the top and bottom risers. - complete Zoning departments items - complete work at first floor fire sprinkler system and submit NFPA letter of compliance. - submit electronic as built drawings. PASSN/O 3 inches vent stack through roof - 18 inches minimum exposed PASS Roof complete PASS Exterior finish of building PASS Grade Complete, 6 in 10ft or Equivalent PASS Interior and exterior guardrails 42 inches platforms and decks PASS Interior and exterior balusters 4 inch max spacing platform and decks PASS Stair rail 34 inches–38 inches high on both sides of stairway, 12 inches beyond top and bottom of stairs install permanent hand railings as discussed on site FAIL Step risers 7 inches max and treads 11 inches minimum PASS Doors 36 inches with Lever Handle and or Panic Hardware, if required PASS Exits At Grade Or Platform 36 inches (w) x 44 inches (l) PASS Floor Bathroom Watertight Other Floors Okay PASS Pressure relief valve, heat trap and water temp 110 deg or less PASS Pressure relief valve down spout within 6 inches of floor PASS Outside spigots have air gap PASS 3/4 hour corridor doors and closers PASS Firewalls, 2 Hr, 3 Hr and fire dampers and fire doors PASS Ceiling fire stopping, 3,000 sq. ft. wood frame PASS Elevator shaft sealed PASS Low flow toilet 1.3 gallons per flushing cycle PASS HC parking lot signage install sign at 60” to bottom of sign. PASS HC parking striping PASS Universal symbol of access displayed PASS Final electrical and flex gas piping bonded PASS Final survey submit final as built site plan PASSN/O Public sewer sign off PASS Building number or tenant address on building or drive PASS Water fountain or cooler PASS Bldg Access All Sides 20ft Drivable Surface PASS Engineer or architect approval PASS Blower door test PASS Elevator hoistways pressurized PASS Electronic as builts submit electronic as builts N/O Special inspections PASS Ok to issue temporary certificate of occupancy Approved for temporary C.O. only PASS Ok to issue certificate of occupancy Mark Smith Code Enforcement Officer