INSPECTION WORKSHEET 05032024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0089 Case Module: Permit
Inspection Date: May 03, 2024 Inspection Status: Reinspect
Inspector: Charles Dyer Inspection Type: Framing
Job Address: 24 Algonquin Dr
Queensbury,NY 12804 Parcel Number: 301.13-2-69
Contact Type Company Name Name
Owner MONSOUR ENTERPRISES, LLC
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
partial ice and water barrier, OK to shingle 5/3/24
PASS
Ice and water shield 24 inches from wall
PASS
Less than 4:12 pitch install double layer
of ice and water shield
N/O
Attic Access 22 inch x 30 inch minimum
with 30 inch head clearance
N/O
Crawl space 18 inches x 24 inches
access, 1 sq. ft. per 150 sq. ft. vents
N/O
Jack Studs, headers and double jack
studs 6' or greater
N/O
Garage portal framing
N/O
Truss Specification Provided on site
N/O
Bracing and bridging
N/O
Hurricane Clips and Uplift Screws all nail
holes filled as per manufacturer
N/O
Jack Posts and Main Beams
N/O
Lag top plates and bottom plates of steel
columns
N/O
Exterior sheeting nailed properly
N/O
Notches, Holes and Bearing Walls
N/O
Headroom 6 ft. 8 in.
N/O
Deck post beam connections must use
hex head bolts
N/O
Joist hangers
N/O
Metal Strapping for Notches Top Plate
N/O
Charles Dyer
Code Enforcement Officer