INSPECTION WORKSHEET 05032024 INSPECTION WORKSHEET Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: RC-0177-2023 Case Module: Permit Inspection Date: May 03, 2024 Inspection Status: Passed Inspector: Charles Dyer Inspection Type: Residential Final Job Address: 1219 West Mountain Rd , Parcel Number: 288.-1-71 Contact Type Company Name Name Primary Owner N/A KENNETH SLAWSON N/A KENNETH SLAWSON Granted Permission N/A KENNETH SLAWSON Checklist Item Status Building Inspector notes for roof repair and interior work after fire PASS 4 inch min building number address visible from road PASS Chimney height, B vent, direct vent location PASS Fresh air intake PASS Fresh air supply 3 feet from grade PASS 3 inch plumbing vent through roof, minimum 18 inches PASS Outside spigots have air gap N/O Roof complete PASS Exterior finish complete PASS Platform at all exterior doors PASS Handrail required with 4 or more risers PASS Guards at stairs, decks and patios 30 inches or more above grade N/O Guard at stairwell at 34 inches or more N/O Window guards req at less than 2' above floor and 6' above grade N/O Interior and exterior handrails 34" to 38" high PASS Grade away from foundation sloping 6 inches in the first 10 feet PASS 6 inch clearance to sill plate from grade N/O Gas meter and or regulator shut off 12 inches min above grade N/O HVAC vent terminal 10 feet from lot line and openings N/O Dryer duct max length 35 feet or per manufacturer's instructions N/O Interior privacy doors and trim required PASS Exterior main entrance door min 36" wide PASS Bathroom and Kitchen floors must be watertight PASS Low flow toilet 1.3 gallon per flushing cycle PASS Smoke detectors are min of 3 feet horizontally from opening of bathroom PASS Smoke Detectors are required on every level and in every bedroom PASS Smoke Detectors are required outside every bedroom area PASS Smoke Detectors have battery back up PASS Smoke detectors are interconnected PASS Carbon monoxide detectors are within 10 ft of all sleeping areas PASS Carbon monoxide detectors are required on all levels with gas appliances (i.e. furnace) PASS Attic access 22 inches x 30 inches minimum with 30 inch high clearance PASS Attic access insulation R-value must equal ceiling R- value PASS Attic access gasketed PASS Pull down stairs boxed out and insulated PASS Bathroom fans required, if no window PASS All plumbing fixtures complete PASS Backflow preventors where required N/O Foundation insulation to basement floor N/O Energy sticker on elec. panel, R values and heating systems N/O All Hot Water Systems R 3 on 3/4 inches or larger piping N/O Duct work sealed properly N/O Intake openings for HVAC N/O Range Hood 400 or more cfm make up air required N/O Floor truss, draft stop required at 1,000 sq. ft. if basement is finished N/O Emergency egress window below grade 44 inches max from sill height from basement floor N/O Furnace shut off within 30 ft. or within line of site PASS Oil furnace shut off at entrance to furnace area N/O Propane tank proper setback from property line or structure N/O Furnace and hot water heater operating PASS Low water shut off required for boiler N/O Pressure relief valve, heat trap, water temp 110 degrees or less PASS Pressure relief valve down spout within 6 inches of floor PASS Encl. stairs sheetrock underside minimum ½ inch gypsum N/O Basement stairs closed rise greater than 4 inches N/O Basement wall insulation R- value verified N/O Basement egress: 5 s.f. window w/sill or Bilco door N/O Jack posts in basement lagged at top and bottom N/O Fireblocking at fl joist 80 s.f. or less N/O Garage floor pitched N/O 1/2" Gypsum board req. in basement for framing if 2" x 8" or TJI/Floor Trusses N/O Fin elect; energy saving light bulbs 90 percent PASS Arc fault breaker habitable spaces PASS Flex gas pipe bonding N/O Truss ID signage installed at electrical meter PASS Electronic as builts N/O Ok to issue temporary certificate of occupancy N/O Ok to issue certificate of occupancy PASS Charles Dyer Code Enforcement Officer