INSPECTION WORKSHEET 05032024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0177-2023 Case Module: Permit
Inspection Date: May 03, 2024 Inspection Status: Passed
Inspector: Charles Dyer Inspection Type: Residential Final
Job Address: 1219 West Mountain Rd
, Parcel Number: 288.-1-71
Contact Type Company Name Name
Primary Owner N/A KENNETH SLAWSON
N/A KENNETH SLAWSON
Granted Permission N/A KENNETH SLAWSON
Checklist Item
Status
Building Inspector notes
for roof repair and interior work after fire
PASS
4 inch min building number address
visible from road
PASS
Chimney height, B vent, direct vent
location
PASS
Fresh air intake
PASS
Fresh air supply 3 feet from grade
PASS
3 inch plumbing vent through roof,
minimum 18 inches
PASS
Outside spigots have air gap
N/O
Roof complete
PASS
Exterior finish complete
PASS
Platform at all exterior doors
PASS
Handrail required with 4 or more risers
PASS
Guards at stairs, decks and patios 30
inches or more above grade
N/O
Guard at stairwell at 34 inches or more
N/O
Window guards req at less than 2' above
floor and 6' above grade
N/O
Interior and exterior handrails 34" to 38"
high
PASS
Grade away from foundation sloping 6
inches in the first 10 feet
PASS
6 inch clearance to sill plate from grade
N/O
Gas meter and or regulator shut off 12
inches min above grade
N/O
HVAC vent terminal 10 feet from lot line
and openings
N/O
Dryer duct max length 35 feet or per
manufacturer's instructions
N/O
Interior privacy doors and trim required
PASS
Exterior main entrance door min 36" wide
PASS
Bathroom and Kitchen floors must be
watertight
PASS
Low flow toilet 1.3 gallon per flushing
cycle
PASS
Smoke detectors are min of 3 feet
horizontally from opening of bathroom
PASS
Smoke Detectors are required on every
level and in every bedroom
PASS
Smoke Detectors are required outside
every bedroom area
PASS
Smoke Detectors have battery back up
PASS
Smoke detectors are interconnected
PASS
Carbon monoxide detectors are within 10
ft of all sleeping areas
PASS
Carbon monoxide detectors are required
on all levels with gas appliances (i.e.
furnace)
PASS
Attic access 22 inches x 30 inches
minimum with 30 inch high clearance
PASS
Attic access insulation R-value must
equal ceiling R- value
PASS
Attic access gasketed
PASS
Pull down stairs boxed out and insulated
PASS
Bathroom fans required, if no window
PASS
All plumbing fixtures complete
PASS
Backflow preventors where required
N/O
Foundation insulation to basement floor
N/O
Energy sticker on elec. panel, R values
and heating systems
N/O
All Hot Water Systems R 3 on 3/4 inches
or larger piping
N/O
Duct work sealed properly
N/O
Intake openings for HVAC
N/O
Range Hood 400 or more cfm make up
air required
N/O
Floor truss, draft stop required at 1,000
sq. ft. if basement is finished
N/O
Emergency egress window below grade
44 inches max from sill height from
basement floor
N/O
Furnace shut off within 30 ft. or within line
of site
PASS
Oil furnace shut off at entrance to furnace
area
N/O
Propane tank proper setback from
property line or structure
N/O
Furnace and hot water heater operating
PASS
Low water shut off required for boiler
N/O
Pressure relief valve, heat trap, water
temp 110 degrees or less
PASS
Pressure relief valve down spout within 6
inches of floor
PASS
Encl. stairs sheetrock underside minimum
½ inch gypsum
N/O
Basement stairs closed rise greater than
4 inches
N/O
Basement wall insulation R- value verified
N/O
Basement egress: 5 s.f. window w/sill or
Bilco door
N/O
Jack posts in basement lagged at top and
bottom
N/O
Fireblocking at fl joist 80 s.f. or less
N/O
Garage floor pitched
N/O
1/2" Gypsum board req. in basement for
framing if 2" x 8" or TJI/Floor Trusses
N/O
Fin elect; energy saving light bulbs 90
percent
PASS
Arc fault breaker habitable spaces
PASS
Flex gas pipe bonding
N/O
Truss ID signage installed at electrical
meter
PASS
Electronic as builts
N/O
Ok to issue temporary certificate of
occupancy
N/O
Ok to issue certificate of occupancy
PASS
Charles Dyer
Code Enforcement Officer