INSPECTION WORKSHEET 05072024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: RC-0004-2024 Case Module: Permit
Inspection Date: May 07, 2024 Inspection Status: Reinspect
Inspector: Charles Dyer Inspection Type: Foundation
Job Address: 56 REARDON RD
, Parcel Number: 289.7-1-17
Contact Type Company Name Name
Granted Permission N/A Michael Rozell
Primary Owner N/A Michael Rozell
N/A Michael Rozell
Engineer Saratoga Engineering & Design
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
partial footings 5/7/24
PASS
Footings
PASS
Piers
N/O
Reinforcement in place
with 2 rows #4 continuous
PASS
Foundation wall pour
N/O
Foundation reinforcement in place
N/O
Footing dowels or keyway in place
PASS
Foundation dampproofing
N/O
Foundation waterproofing
N/O
Footing drain to daylight or to sump pit
N/O
Footing drain stone - 12 inch width
N/O
Footing drain stone -- 6 inches above
footing
N/O
Footing drain stone -- 6 mil poly
N/O
Backfill approved
N/O
Plumbing under slab
N/O
Pressure test
N/O
Air or head test
N/O
5 psi or 10 ft. above highest connection
for 15 minutes
N/O
PVC, Cast, Copper and Pex tubing
N/O
Foundation Insulation Interior or Exterior
N/O
Rough Grade 6 inch drop within 10 ft.
N/O
Poly under slab in wet areas
N/O
Charles Dyer
Code Enforcement Officer