INSPECTION WORKSHEET 05092024
INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0066 Case Module: Permit
Inspection Date: May 09, 2024 Inspection Status: Reinspect
Inspector: Mark Smith Inspection Type: Septic
Job Address: 11 SIGN POST RD
Lake George,NY 12845 Parcel Number: 239.16-1-7
Contact Type Company Name Name
Owner N/A MICHAEL L LOUGHREY
Engineer Environmental Design Partnership (EDP) null null
Contractor IBS Septic & Drain
Checklist Item
Status
Building Inspector notes
5/3/24 partial approval for septic system
- partial approval of absorption field, 3 of the eljen mats at each lateral
installed and approved to back fill.
5/6/24 partial approval for septic system
- absorption field partially approved, 6 of 8 Eljen mat’s installed at each
lateral.
5/7/24 partial approval for septic system
- remainder of absorption field approved.
2 laterals of 8 Eljen mats each verified.
5/9/24 partial approval for septic system, submit as built drawing and
letter of substantial completion from design engineer for final approval.
- a 500 gallon pump tank with a grinder pump and 2” forced main with a
1000 gallon septic tank and an absorption field of 16 Eljen mats was
installed.
PASS
Roof gutters don't discharge over leach
field
PASS
Soil type: loam
PASS
Type of water: municipal or well water
lake water supply
PASSN/O
Waterline separation distance
PASS
Total length of absorption fields
16 Eljen mats, 8 in each lateral.
PASS
Septic system field above field plain
PASS
Sump pump not connected to septic
system
N/O
Water softener not hooked to septic
system
N/O
Length of each trench
16 Eljen mats, 8 in each lateral.
PASS
Depth of trenches
PASS
System use status
system approved.
PASS
Opening sealed
PASS
End cap
PASS
Inlet outlet pipes and baffles, provide
extension collar if yes
PASS
Locations and separations
PASS
Distance from foundation to tank
Distance from foundation to absorption
field
Size of tank
500 gallon pump tank with a 1000 gallon septic tank.
PASS
50 percent alarm level activates
PASS
90 percent alarm level activates
PASS
Final electrical
PASS
Conforms as per plot plan
PASS
Engineer report and as-built
FAIL
Location of system on property
see specs
PASS
Mark Smith
Code Enforcement Officer