Loading...
1.8 1.8 WASTEWATER-SEWER\Set PHTheckla—Replacement with Absorption Setbacks—In APA-6-3-2024 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF BRUCE AND JOY CHECKLA RESOLUTION NO.: ,2024 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, Bruce and Joy Checkla(Applicants) have applied to the Local Board of Health for variances from Chapter 136 to install a new septic system with certain of its components to be located as follows: 1. absorption field to be located 74' from the onsite well in lieu of the required 100' setback; 2. absorption field tapers to be located 3' from the north property line in lieu of the required 10' setback; 3. absorption field tapers to be located 2' from the west property line in lieu of the required 10' setback; 4. absorption field tapers to be located 2' from the east property line in lieu of the required 10' setback; and 5. absorption field tapers to be located 68' from the well in lieu of the required 100' setback; on property located at 3 Lackey Road in the Town of Queensbury, NOW, THEREFORE, BE IT RESOLVED, that the Town of Queensbury Local Board of Health will hold a public hearing on Monday, June 17d', 2024 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider Bruce and Joy Checkla's sewage disposal variance application concerning property located at 3 Lackey Road in the Town of Queensbury (Tax Map No.: 226.12- 1-28) and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500 feet of the property as required by law. Duly adopted this 3rd day of June, 2024,by the following vote: AYES NOES ABSENT: 169 Haviland Road Queensbury, NY 12804 Phone: (518) 746-0307 Hutchins Engineering PLLC Fax: t518) 745-0308 t` May 29, 2024 d P �J Town of Queensbury Local Board of Heath `O 742 Bay Road Queensbury NY 12804 tp Re: Bruce and Joy Checkla — 3 Lackey Rd. — Ripley Point — Lake George ~ Septic Variance Tax Map ID: 22& 12-1 -28 Dear Supervisor Strough and Town Board Members: This office represents Bruce and Joy Checkla with respect to a wastewater system installation at their 3 Lackey Road property. The current system services the three-bedroom residence. Currently, the residence is served by 1 ,000-gallon septic tank which will be pumped, inspected, and reused as well as a failing seepage pit which will be decommissioned. The new septic system will consist of the existing 1 ,000-gallon precast concrete septic tank, a 1 ,000-gallon pump station, and (2) 37' Eljen trenches in shallow fill configuration. Variance requests to the Local Board of Health are as follows: 1 ) 74' from the absorption field to the onsite well instead of the required 100' ; 2) 3' from the absorption field tapers to the North property line instead of the required 10'; 3) 2' from the absorption field tapers to the West property line instead of the required 10'; 4) 2' from the absorption field tapers to the East property line instead of the required 10% 5) 68' from the absorption field tapers to the well instead of the required 100' We respectfully request that this application be placed upon the Town Board's meeting agendas for the next upcoming meetings. Please contact me with any questions that you may have or if you would like to perform a site visit. Thank you for your assistance with the project_ Best regards, o G. Thomas Hutchins, P. E. Enclosures Cc Bruce and Joy Checkla Hutchins Engineering PLLC 4 SEPTIC VARIANCE Office Use OnI Permit #. �— APPLICATION Permit Fee: $ rover+ d Invoice #: 742 Bay Road, Queensbury, NV i2804 Approvals: P. 528-761-8256 w+w+w. ueensbu .ne Submittal: 1 (one) original & 8 copies of the completed application package PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN ENTAIL Section 1• Contact Information: Property Owner(s): Bruce and Joy Checkia Owner's Agent: _HUTCHINS ENGINEERING PLLC ,Address: P .O_ Box 54 address: _169 HAVILAND ROAD Cloverdale, NY 12820 QUEENSBURY, NY 12804 Phone #: Phone #: 518-745-0307 Email. _ __ Email : thutchins(gDHUTCHINSENGINEERING.COM Section 2: Site Information: site Address: 3 Lackey Road Tax iD#: 226. 12-1 -28 Directions to Site; from Bay Road turn right onto NY-91L S for 1 .7 miles; turn left onto Cleverdale Rd for 1 .4 miles, turn left onto Lackey Rd for 154 ft; residence on the right Section 3: Distance from well on property to septic system (if applicable) 7$ (to field) feet Section 4• Is it possible to install a conforming septic system on this property? ❑ Yes NO If YES, please explain and attach a diagram: _ Section 5• Does the proposed system meet setback requirements for distance from wells & septic systems on neighboring properties? ■ Yes [D No If NO, please explain: Eljen absorption field will be 76' from owners well in lieu of 100' required Section 6• Is the proposed system to be installed under a parking area? F] Yes No Section 7• Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system wi11 be 89 ft. from well in lieu of required 100 ft.): See full description on cover letter and plans Revised December 2021 Septic Ya ria nce AP pl ica[i on Section 8• List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Q.ueensbury's Assessor's Office: North Name Craig Merry Address 82 Mason Road Tax Map ID 226. 12-1 -35 South Name Iris Bra Address Mason Read Tax Map ID 226. 12-1 -11 East Name Joseph Clemente Address 76 Mason Road Tax Map ID 226. 12-1 -30 Vilest Name Gregory Reisch f Thomas Koleci Address 317 Cleverdale Rd / 315 Cleverdale Rd Tax Map ID 226. 12-1 -32 1 226. 12-1 -29 Section 9: OWNER STATEMENT l/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system Incated at: 3 Lackey Rd I/We realize that putting the well, septic tank or leaching system less than the required 100 feet from the water supply well may increase the risk of pollution, Owner—Print Name: 60r6/ 645 L .. Owner—Signature: 0I) " Date: Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT (If pppl#cpbIe) I/We do hereby relieve the Town of Queensbu -y from any liabilities on the plumbing and septic system located at: . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: Neighbor/Tenant-Signature: Date: 5eptic Variance Application Revised December 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required_ Complete the following if the OWNER is using an Agent: owners Name : Bruce and Joy Checkla HUTCHIN5 ENGINEERING, PLLC Designates: a5 agent regarding the Septic Variance for Site Address: 3 Lackey Road Tax Map #: 226 . 12- 1 -28 Engineering Fee Disciosure:_Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Town Board of Health . Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached herein, the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted . Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer, the handwritten minutes shall be deemed the official record_ I, the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER— PRINT NAME: Bruce or Joy Checkla OWNER—SIGNATURE : DATE: 05/29/24 AGENT---PRINT NAME: G . Thomas Hutchins, P. E . AGENT—SIGNATURE : - -�' DATE: 05/29/24 Septic Variance Application Revised December 2021 IY PT-2 — — I ' / L i ----J % PT-3 W i TA Ale _ I ; 3t1vHN � 100 -__ 10' MIN. TYP GENERATOR LANDS N/F ' �`"'------_� LANDS N/F / l MERRY, CRAIG ' � REISCH, GREFORY I 226.12-1-35 2' MIN I �� 226.12-1-32 NO WELL- LAKE �i ` ; \ NO WELL- LAKE WATER SUPPLY j I ��� _ ' \ WATER SUPPLY / I + F; PROPOSE"037 ELJEN ABSORPTION 2 TRENCH, 18 M ULES PROVIDED F \F � 1 - - 38.7 ' ' 86'14' - - ' ' PROPOSED D►STRIBU BOX 04" W --- --_+ c, TOP OF FILL + l F / I EXISTING FAILED SEEPA , TO F BE DECOMMISSIONED TP I ' % F OE 0 FIL ROPOSED EFFLUENT FORCEMAIN �F + 46.0' O ROPOSED 1,000 GAL PUMP STATION \ IW LANDS N/F F + W CLEMENTE JOSEPH \F - -- \ I 226.12- 1-30 I Ear O L w VACANT + F F EXISTING 1,000 GAL PRECAST CONCRETE SEPTIC TANK / I + F W \ \ +_ _ _ EXISTING HOUSE SEWER 5 I II 76.0' / I 68.8 \ I I LANDS N/F KOLECI, THOMAS I+ o \ + I 226,12-1-29 / ' IEXISTING 3 I ' NO WELL- LAKE / I+ BEDROOM I\ ; I WATER SUPPLY ' II RESIDENCE..:_: I j II I I _j I I + I--�--�- EXISTING / + � WASTEWATER SYSTEM PLAN \ SCALE. 1"=10' CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES VARIANCE REQUEST SUMMARY THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY SANITARY ORDINANCE. 1) INSTALL ABSORPTION FIELD 76' FROM WELL IN LIEU OF REQUIRED 100'. 2) INSTALL ABSORPTION FIELD TAPERS 3' FROM NORTH PROPERTY LINE IN LIEU OF REQUIRED 10'. 3) INSTALL ABSORPTION FIELD TAPERS 2' FROM WEST PROPERTY LINE 1N LIEU OF REQUIRED 10'. 4) INSTALL ABSORPTION FIELD TAPERS 2' FROM EAST PROPERTY LINE IN LIEU OF REQUIRED 10'. 5) INSTALL ABSORPTION FIELD TAPERS 68' FROM WELL IN LIEU OF REQUIRED 100'. WATER SUPPLY PROTECTION NOTE A WATER TREATMENT SYSTEM WHICH INCLUDES DISINFECTION IS INSTALLED ON THE WATER SUPPLY INTO THE RESIDENCE PRIOR TO DISTRIBUTION. WASTEWATER SYSTEM DESIGN 3-BEDROOM EXISTING RESIDENCE DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 330 GPD SEPTIC TANK - EXISTING 1,000 GAL PRECAST CONCRETE TANK TO REMAIN PUMP STATION - NEW 1,000 GAL PRECAST CONCRETE ABSORPTION FIELD- ELJEN TRENCHES IN STABILIZED FILL DESIGN PERCOLATION RATE=0.8 GPD/SF, BASED ON 11-15 MIN/IN MINIMUM TRENCH LENGTH REQUIRED = 72 LF (PER ELJEN NEW YORK DESIGN & INSTALLATION MANUAL) (2)ELJEN TRENCHES ® 37' LONG EACH. 2 ROWS OF 9 MODULES PROVIDED: 18 MODULES TOTAL POTABLE WATER SUPPLY IS ON -SITE WELL -MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEPTIC TANK & WATERBODIES OR WELLS -MAINTAIN 100' MINIMUM SEPARATION BETWEEN ABSORPTION FIELD, WELLS & WATERBODIES (VARIANCE REQUESTED) SITE SOILS DATA TEST PIT .LP-1 - 1212012023 BY. TOM HUTCHINS, P.E. 0-6" - TOPSOIL 6-29" - LIGHT BROWN GRAVELLY SAND FILL 29-60" - OLIVE BROWN SILT LOAM, MOTTED WATER 0 33" MOTT ® 31 " BOUNDARY CONDITION 0 31" PERCOLATION TESTS PT-1 - 61212020 BY.• TOM HUTCHINS, P.E. STABILIZED PERCOLATION RATE: 12 MINUTES PER INCH Dig ® Safely. New ®York Call Before You Dig IM Wait The Required Time Confirm Utility Response Respect The Marks Dig With Care 800-962-7962 www.digoatelynewyark.com o N O N LOCATION MAP SYSTEM INSTALLATION NOTES I CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. W DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF Qcc 0 THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. (!) o N AFTER EXCAVATION OF 15' WIDE X 30' LONG ABSORPTION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF cn SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS. PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. 0 0 z DO NOT USE HEAVY EQUIPMENT IMTHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT 1S THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS. WASTEWATER SYSTEM MATERIAL SPECIFICATIONS A CTM r?? CA Air) SYSTEM SAND TO BE ASTM C33 WASHED CONCRETE SAND. SEE "ASTM C33 SAND GRADATION" FOR SPECIFICATIONS. Cnn.-cneA rep PIPING TO BE 2" SDR-11 HDPE, PROVIDE POSITIVE DRAINBACK TO PUMP STATION. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, T1=NCATE MIRAFI 140N OR EQUIVALENT. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 114" PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD AREA. SEED, MULCH AND ESTABLISH TURF. MAP REFERENCE: ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Am� Hutchins Engineering PLLC 169 Havilond Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fax TAX MAP # 226.12-1-28 WASTEWATER SYSTEM PLAN prepared for: Bruce Checkla 3 Lackey RD Town of Queensbury, County of Warren, State of New York WASTEWATER SYS'rEM SETBACK REQUIREMENTS STREAM, LAKE, PROPERTY LINE HOUSE WATERCOURSE, WELL WETLAND SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 1 10' 1 20' 1 100' 1 100' 1. BASE MAP INFORMATION FROM "MAP OF A SURVEY MADE FOR BRUCE & JOY CHECKLA, BY VANDUSEN & STEVES LAND SURVEYORS" 2. NORTHERLY NEIGHBOR PROPERTY INFORMATION FROM "MAP OF A SURVEY MADE FOR JAMES FINNECY," TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED SEPTEMBER 24, 1993. PREPARED BY VAN DUSEN & STEVES LAND SURVEYORS, GLENS FALLS, NY. Drawn: AVA IChockod. GTH Scale: NOTED Date: 11/7/2029 292263-01-S 1 WASTEWATER SYSTEM FILL MATERIAL NOTES AFTER REMOVING ORGANICS AND TOPSOIL, PLACE WASTEWATER SYSTEM FILL OVER THE ENTIRE AREA OF PROPOSED ABSORPTION FIELD AND TAPER AREA. "WASTEWATER SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND, SANDY LOAM OR SANDY LOAMY GRAVEL WITH IN -PLACE PERCOLATION RATE OF 3-5 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3" IN SIZE. LESS THAN 107. BY WEIGHT SHALL BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 15% OF THE MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE. WASTEWATER SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE MINIMUM OF 3-FEET BETWEEN BEDROCK AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION FIELD AREA AND TAPER AREAS. WASTEWATER SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT PRIOR TO INSTALLATION OF ABSORPTION FIELD. INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF WASTEWATER SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE ASTM C33 SAND SPECIFICATION SIEVE PERCENT PASSING 318" (9.5-mm) 100% No. 4 (4.75-mm) 95-100% No. 8 (2.36-mm) 80-100% No. 16 (1.18-mm) 50-85% No. 30 (600-µm) 25-60% No. 50 (300-µm) 5-3010.' No. 100 (150-µm) 0-10% No. 200 (75-µm) 0-5% (MUST BE OBTAINED BY WASHING) 4" PVC SDR-35 INLET MIN. SLOPE , 114" PER FOOT WATERTIGHT SLEEVE AND SEAL (TYP) EXISTING 1000 GALLON PRECAST CONCRETE SEPTIC TANK TO BE PUMPED & INSPECTED FOR WATERTIGHTNESS SEPTIC TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. ALL STRU('TURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BtSE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BA 5E- SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY COP'STRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING. 4" MIN. TOPSOIL, ESTABLISH TURF 4" SCH 40 PVC PERFORATED PIPE GEO-TEXTILE COVER WASHED CONCRETE SAND CONFORMING TO NYSDOT SPECIFICATION 703-07 IN -DRAIN UNIT HOLES ® 5&7 O'CLOCK 12' MIN 5 RFTWFFN 1 g.� 1•r DETAILED EVEN MODULE SECTION SCALE. NTS 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF SLOPE APPROXIMATE WASTEWATER SYSTEM FILL MATERIAL POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER (NON -TRAFFIC AREAS) a 2" LIQUID LEVEL O a� ° 16" 18" MIN. 1 LJ W Z X oo_ CY �O MINIMUM 2X WIDTH MAXIMUM 4X WIDTH a a a EXISTING 1000 GALLON PRECAST CONCRETE SEPTIC TANK TYPICAL ELJEN IN —DRAIN ABSORPTION TRENCH (2) REQUIRED EACH 37' LONG ' TYP. TRENCH SPACING 4' ABSORPTION FIELD SECTION NTS INSTALL EFFLUENT FILTER SUCH THAT IT IS READILY REMOVABLE THROUGH TANK ACCESS COVER 118" PER FOOT a MIN. SLOPE TLET 4" PVC SDR-35 ASTM C33 WASHED CONCRETE SAND POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDI CA TED BALL VAL VE INSTALL VALVE AND UNION SUCH THAT PUMP CAN BE ISOLATED AND REMOVED WITHOUT REQUIRING PIT ENTRY BALL CHECK VALVE ALARM 3" ABOVE 'PUMP ON' PUMP ON FLOAT SWITCHES —INSTALL INSIDE PUMP PIT IN LOCATION ACCESSIBLE PUMP OFFS— WITHOUT PIT ENTRY VOLUME OF DOSE TO BE 40f GALLONS 16" MIN. TAPER AREA — MAXIMUM SLOPE 1:3. SYSTEM FILL MATERIAL ALL AROUND EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. TRANSITION TO 4" OUTSIDE OF 12" MIN. COVER D-BOX DISTRIBUTION BOX BAFFLE USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 4" PVC SDR-35 SOLID HEADER TO PERFORATED ABSORPTION TRENCH PIPING, 1/8" PER FOOT MIN SLOPE 2" PVC SDR-26 FORCEMAIN ­2" SCH-40 PVC PIPING INSIDE WET WELL THROUGH WALL UNION — LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PUMP REMOVED WITHOUT TANK ENTRY REDUCING TEE POINTED DOWNWARD WITH 1" BALL VALVE THROTTLED TO ALLOW TRICKLE DRAIN BACK INTO WETWELL SIMPLEX EFFLUENT PUMP SITE LOCATION —i LOCATION MAP 27MIN. DROP BETWEEN INVERTS 2"MIN. PUMP STATION NOTES SEAL ALL TANK OPENINGS WATERTIGHT. PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, ALTERNATING, DEMAND DOSE CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION. INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.EC.) REQUIREMENTS. PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO PROVIDE DEMAND DOSING AND TO PROVIDE A 40 GAL DOSE. PUMP TO BE GOULDS MODEL 3885, WE03M 11OV, 113 HP, SINGLE PHASE, 30 GPM 0 25—FT TDH. VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. WASTEWATER SYSTEM SETBACK REQUIREMENTS STREAM, LAKE, PROPERTY LINE HOUSE WATERCOURSE, WELL WETLAND SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 100' Dig Safely, New®York Call Before You Dig IM Walt The Required Time III Confirm Utility Response Respect The Marks Dig With Care 800.962.7962 www.digeafelynewyork.com O r- O_ O � 2 .3 a) Cr ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Hoviland Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fax TAX MAP # 226.12-1-28 WASTEWATER SYSTEM DETAILS prepared for: Bruce Checkla 3 Lackey RD Town of Queensbury, County of Warren, State of New York Drawn: AVA Checked: GTH Scale: NOTED Date: 111712023 292263-01-S2