Six Flags Bobcat Roller Coaster Proof Roll observation report 3CONSTRUCTION TECHNOLOGY
INSPECTION & TESTING DIVISION, P.D.& T.S., INC.
4 William Street, Ballston Lake, New York 12019
Phone: (518) 399-1848 Email: constructiontech@live.com
CLIENT:ROZELL INDUSTRIES REPORT NUMBER:
REPORT DATE:
OUR FILE NUMBER:
FIELD INSPECTOR:
ATT'N:
PROJECT:
MANAGER TECHNICAL SERVICES
1. FILE
2:
3:
4:
5:
6:
7:
8:
CONSTRUCTION TECHNOLOGY
ROBERT BEHAN (NICET)
Robert BehanRobert BehanRobert BehanRobert Behan
REPORT DISTRIBUTION
FIELD OBSERVATION REPORT:
RESPECTFULLY SUBMITTED,
: PAGE 13
Should there be any questions, or additional information requested, please contact this office immediately.
As requested, CONSTRUCTION TECHNOLOGY visited the referenced project site for the purpose of observing
the proof-rolling operations conducted by the site contractor.
The site contractor employed a 10 ton roller on footing Subgrade sections P58 - P61 sub-subbase material. The
contractor made overlapping passes with the roller over the entire area.
We hope the foregoing information is of assistance.
MR. MIKE WILLIGAN
SCOTT ROBBINS
BOBCAT ROLLER COASTER: SIX FLAGS GREAT ADVENTURE: QUEENSBURY, NEW YORK
12/27/2023
574.047
129 PARK ROAD
QUEENSBURY, NEW YORK 12804
Upon completion, the following information is provided:
The entire area appeared stable with NO apparent weaving or pumping of the subgrade. Deflection of the subgrade
was limited to less than 0.5" under the weight of the roller.