Loading...
1990-729 • - ' ti d'` CERTIF'ICATE OF COMPLIANCE TOWN OF QUEENSBURY _ WARREN COUNTY, NEW YORK Date October 259 This is to certify that work requested to be done as shown by Permit No. 90-729 has been completed. This structure may be occupied as a sept[Nc system 13 Garner Street Location ANTONIO MANDOLARE Owner By Order Town Board l TOWN OF QUEENSBURY > y Director of Bldg. do Code Enforcement • BUILDING PERMIT x TOWN OF QUEENSBURY No. 90_729 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to ANTONIO MANDOLARE OWNER of property located at 13 Garner St Street, Road or Ave. i" in the Town of Queensbury,To Construct or place a Sewage alteration at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is Burgoyne Av Hudson Falls NY 12839 2. CONTRACTOR or BUILDER'S Name r r— n Sanders Excavating 3. CONTRACTOR or BUILDER'S Address 0 0 4. ARCHITECT'S Name 5. ARCHITECT'S Address N W SJ7 w CD 6. TYPE of Construction— (Please indicate by X) "S to ( I Wood Frame ( ) Masonry ( )Steel ( ) c-I- 7. PLANS and Specifications ; No. Sewage alteration to include 1000 gallon septic tank with 260 feet of tile field with #2 stone at 1 ft. 8. Proposed Use Septic system CD 0) 25.00 October 22 92co $ PERMIT FEE PAID —THIS PERMIT EXPIRES 19 pu (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) rD c-t- Dated at the Town of Queensbury this D f October 19 90 0 SIGNED BY for the Town of Queensbury Building and o ing Inspector /. /- 5-- TOWN OF QUEENSBURY O� 41,W APPLICATIOIl FOR SEPTIC DISPOSAL PE T 4 DATE: OG/- (IF QU. EIS URY LOCATION OF PROPERTY FOR INSTALLATION / 3 /-cic' 'r S '/4- Owner' s Name: a n10 AA) NO4 la' OCT 1990 Address: gu l'5D)K., P� �e 1✓� 6 a l-/ BLDG. & CODE i EPT, Installer' s Name: e5 wt 5C4 v? Telephone: 7 3--2,115-" Number of bedrooms (residential only) t Total daily flow (compute @ 150 gal per bedroom) . z 7c (7 Topography: Circle one: 67 Rolling Steep Slope % of Slope Soil Nature: Circle one: a Loam Clay Other /Depth: Ground Water: At what depth? - Feet Bedrock or Impervious Material : At what de th? Feet Percolation test: Circle one: of required.,-) required Rate - Min. Per Inch Domestic water supply: Circle one:(i icipa l Well Other If domestic water supply is a wel1: T Separation: Water supply from any septic absorption feet. PROPOSED SYSTEM: Septic Tank ,/2'U gal . (minimum size: 1,000 gal ) TILE FIELD: Each Trench 3 feet/Total system length feet SEEPAGE PIT(S): Number of /Size each feet by feet Size of stone to be used #. /Depth or Thickness. J feet ***************************** HOLDING TANK SYSTEM IF REQUIRED NO. of Tanks Size of Each Gal . *Alarm system and associated electrical work to be inspected by an approved agency. I have read the regulation on the reverse side of this sheet and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. � DA SIGNATURE OF RESPONSIBLE PERSON: TE d/ • • Septic System Inspections: • A. All applications for septic system installation, alteration or repair, as required by the Town of Queensbury Sanitary Sewage Ordinance, -shall be submitted to the Building Department at least 24 hours before start of construction and shall include a plot plan showing: 1.) the proposed location of the system 2.) location and distance to lot lines 3.) location and distance to structures 4.) location and distance to any water supply . 5.) size and dimensions of all tanks, distribution boxes, tile fields and/or drywalls B. No system shall be covered before inspection and approval by the Building Inspector. Failure to comply with this requirement may result in the uncovering of the system by the installer and a fine of up to $250.00. C. An approved copy of the plot plan shall be available on the construction site. Failure to produce said plot plan at time of inspection may - result in an immediate work stoppage. D. Should unforeseen problems during construction prevent proper installa— tion, alteration or repair of an approved system, a new proposal must be submitted to the Queunsbury Building Department before further construction. Town of Queensbury BUILDING and CODES DEPARTMENT Bay and Haviland Roads Queensbury, New York 12804 • Remarks: • • _own of Queeni‘ury BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 1 SEPTIC DI(POSAL SYSTEM INSPECTION • NAME '' • A di'4i_ LOCATION )\.? bC )..)UYL L- DATE /0 /1 'PERMIT NO. 90t 7,79 SOIL TYPE = Sand - Loam - Clay - Percolation Test Required? YES/ NO Percolation rate - in/Inch _ TYPE of SYSTEM: / Absorption field, total length 2 ; O Length of each trench\ 5 ` ' L,,,Y' G i _c Depth of trenches 2-C� tr Size of gravel -z- _/ SEEPAGE P ITS�Ntu�be-of) 2.0 j Size- __ -f L.. XX ft. �' Grue�I7ize . _ f \ PIPING: •► -1-JJ Size \ Type Bldg. to I 1 .\\ pv c._ Tank to dist. box I Li ',P(/' ,-,-- Dist. boy: to field/pit 3 y Ill/ __ Openings sealed? at NO ° Partial li LOCATION/SEPARATIONS: Foundation to tank i ft. Foundation to abscrption ft. Absorption to lot line ft. Qp.a Separation of pits ,'{ ft. LOCATION OF SYSTEM ,ON PROPERTY(dircle one) Front -(eq.- Left/ side - Right side - COMMENTS: V /f 194--f4 Pkr PIA A, • 1 i SYSTEM USE APPROVED ES NO 7) c / ; 2;; .l Building ns•-ctor \ 01/86 and vl /Do N I� v) r____________---- r-— (0 ___ ---- ,1"-- ' ( )) 2. -----------\ °C c) 1® Jb