Loading...
1.5 1.5 WASTEWATER-SEWER\Set PHTonway—Replacement with Components to Well House Lane-6-17-2024 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF ADAM AND TRYNTZE CONWAY RESOLUTION NO.: ,2024 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS,the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, Adam and Tryntze Conway (Applicants) have applied to the Local Board of Health for variances from Chapter 136 to install a replacement on-site wastewater system with certain of its components to be located as follows: 1. Pump station 23' from the onsite well in lieu of the required 50' setback; 2. Pump station 3' from the house in lieu of the required 10' setback; 3. Pump Station 3' from the south property line in lieu of the required 10' setback; 4. Force main 21' from the onsite well in lieu of the required 50' setback; and 5. Force main 5' from the south property line in lieu of the required 10' setback; on property located at 74 Reardon Road in the Town of Queensbury, NOW, THEREFORE, BE IT RESOLVED,that the Town of Queensbury Local Board of Health will hold a public hearing on Monday, July 1", 2024 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider Adam and Tryntze Conway's sewage disposal variance application concerning property located at 74 Reardon Road in the Town of Queensbury(Tax Map No.: 289.11- 1-36) and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500 feet of the property as required by law. Duly adopted this 17'h day of June, 2024,by the following vote: AYES NOES ABSENT: 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC Phone: (518)745-0307 Fax: (518)745-0308 June 12, 2024 Town of Queensbury Local Board of Health 742 Bay Road Queensbury NY 12804 Re: Adam and Tryntze Conway— 74 Reardon Road, Glen Lake Septic Variance Tax Map ID: 289.11-1-36 Dear Supervisor Strough and Town Board Members: This office represents Adam and Tryntze Conway with respect to a wastewater system installation at their 74 Reardon Road property. Currently, the residence is served by an antiquated single-vessel system that is within 50' of Glen Lake. Variance requests to the Local Board of Health are as follows: 1) 23' from the pump station to the onsite well instead of the required 50'; 2) 3' from the pump station to the house instead of the required 10'; 3) 3' from the pump station to the south property line instead of the required 10'; 4) 21' from the forcemain to the onsite well instead of the required 50'; 5) 5' from the forcemain to south property line instead of the required 10' We respectfully request that this application be placed on the Town Board's meeting agendas for the next upcoming meetings. Please contact me with any questions that you may have or if you would like to perform a site visit. Thank you for your assistance with the project. Best regards, A G. Thomas Hutchins, P.E. Enclosures Cc. Adam and Tryntze Conway Hutchins Engineering PLLC 292293-Conway SEPTIC VARIANCE Office Use Only - ll I Permit#: APPLICATION Permit Fee:$ town of Q ccn7auEy Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensbury.net Approvals: Submittal: 1 (one) original & 8 copies of the completed application paac�l�ag p PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN'EMAIL0122024 SBVR•1 Section 1: EN O ,i f� �� tp Contact Information: 9� g E � Property Owner(s): Adam and Tryntze Conway Owner's Agent: HUTCHINS ENGINEERING,PLLC • Address: 73 N. Helderberg Parkway Address: 169 HAVILAND ROAD Slingerlands, NY 12159 QUEENSBURY,NY 12804 Phone#: 518-810-3960 Phone#: 518-745-0307 Email: tryntzeconway@gmail.com; aconway1999@yahoo.com Email: thutchins@hutchinsengineering.com Section 2: Site Information: Site Address: 74 Reardon Road Tax ID#: 289.11-1-36 Directions to Site: from Bay Rd turn left on Tee Hill Rd for 0.6 miles; left on Reardon Rd for 0.3 miles (on right) Section 3: 105'(absorption field)21'(pump station) Distance from well on property to septic system (if applicable) feet Section 4: Is it possible to install a conforming septic system on this property? ❑Yes No If YES, please explain and attach a diagram: Section 5: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? ❑�Yes ❑ No If NO, please explain: Section 6: Is the proposed system to be installed under a parking area? ❑Yes ❑■ No Section 7: Section of the Sanitary Sewage Ordinance from which you are seeking the variance(i.e. leaching system will be 89 ft. from well in lieu of required 100 ft.): see plans for list Septic Variance Application Revised December 2021 Section 8: List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name Seidel Family Irrevocable Trust Address 70 Reardon Road Tax Map ID 289.11-1-37 South Name Sharon Stephenson Address 76 Reardon Road Tax Map ID 289.11-1-35 East Name Jeffrey Robillard Address 66 Hall Road Tax Map ID 289.11-1-59.121 West Name Glen Lake Address Tax Map ID Section 9: OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 74 Reardon Rd . I/We realize that putting the pump station less than the required 50 feet from the well may increase the risk of pollution. Owner—Print Name: Tryntze or Adam Conway Owner—Signature: Date: 06/12/2024 Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT(If applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: . I/We realize that putting the well, septic tank or leaching system less than the required feet from the may Increase the risk of pollution, Neighbor/Tenant—Print Name: Neighbor/Tenant-Signature: Date: Septic Variance Application Revised December 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: Tryntze and Adam Conway HUTCHINS ENGINEERING PLLC Designates: as agent regarding the Septic Variance for Site Address: 74 Reardon Road - Tax Map #: 289.11-1-36 Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design,storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Author'ization for.Site Visits: By signing this page and submitting the application materials attached herein,the Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER—PRINT NAME: Tryntze or Adam Conway _- OWNER—SIGNATURE: — DATE: 2. 'Z / P.E. AGENT—PRINT NAME: h mas. 1.1 InS, AGENT—SIGNATURE: _ DATE: �.. Septic Variance Application Revised December 2021 \ Zlz La as N/F o en & aron B:635 P I28911_1_3= I WASTEWATER SYSTEM PLAN SCALE: 1 "=20' GRAPHIC SCALE 10 9 2 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES .............. / Lands N/F of !chard & Tina DeMarsh S �604 B:6850 P:48 A� � _3 3�„ 289. 1 1-1-38 150 �_.., 1 dPF VARIANCE REQUEST SUMMARY THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY SANITARY ORDINANCE: 1) INSTALL PUMP STATION 23' FROM WELL IN LIEU OF REQUIRED 50'. 2) INSTALL PUMP STATION 3' FROM BUILDING FOUNDATION IN LIEU OF REQUIRED 10'. 3) INSTALL PUMP STATION 3' FROM SOUTH PROPERTY LINE IN LIEU OF REQUIRED 10'. 4) INSTALL FORCE MAIN 21' FROM WELL IN LIEU OF REQUIRED 50'. 5) INSTALL FORCE MAIN 5' FROM SOUTH PROPERTY LINE IN LIEU OF REQUIRED 101. SITE LOCATION —/ LOCATION MAP WASTEWATER SYSTEM DESIGN 3-BEDROOM RESIDENCE (DESIGN TO 4) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 440 GPD PUMP STATION-4'0 PRECAST CONCRETE WITH DUPLEX GRINDER PUMPS SEPTIC TANK - 1500 PRECAST CONCRETE DUAL COMPARTMENT DESIGN APPLICATION RATE: .95 GPD/SF, BASED ON 1-5 MIN/IN PERCOLA110N RATE ABSORPTION BED AREA REQ'D = (440 GPD)/(.95 GPD/SF) = 463 SF POTABLE WATER SUPPLY IS TO BE ON -SITE WELL SYSTEM MATERIAL SPECIFICATIONS ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT. FORCEMAIN PIPING TO BE 1-112" SDR-11 HDPE, PROVIDE POSITIVE DRAINBACK TO PUMP STATION. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 114" PER FOOT MINIMUM SLOPE. SYSTEM FILL AS DESCRIBED IN "FILL MATERIAL NOTES." TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS. MAP REFERENCE: 1. BASE MAP INFORMATION FROM "MAP OF A TOPOGRAPHIC SURVEY MADE FOR TRYNTZE & ADAM CONWAY" BY VAN DUSEN & STEVES LAND SURVEYORS, JANUARY 17, 2024. Dig ® Safely. New ®York Cali Before You Dig Wait The Required Time Confirm Utility Response Respect The Marks Dig With Care 800.962.7962 www.diguatelynewyork.com am ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A Hutchins Engineering PLLC 169 HoWand Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fax AX MAP # 289.11-1-36 WASTEWATER SYSTEM PLAN & DETAILS prepared for Tryntze and Adam Conway 74 Reardon Road Town of Queensbury, County of Warren, State of New York WASTEWATEF SYSTEM SETBACK REQUIREMENTS STREAM, LAKE, ZOPERTY LINE HOUSE WATERCOURSE, WELL F WETLAND 10' 10' 50' S0' SEPTIC TANK ABSORPTION FIELD 10' 20' 100' 100' Drawn: AVA Checked: OTH Scale: NOTED Date: 0310612024 292293-01-S1 Dig ® Safely. New AYork CAST IRON MANHOLE COVER W/WATER 77GHT INSERT PRECAST CONCRETE — RISER 4" PVC SDR-35 U I INLET LAG/ALARM 3" ABOVE 'PUMP ON' LEAD PUMP ON PUMP OFF VOLUME OF DOSE TO BE 60 i GALLONS (7-8" BETWEEN ON AND OFF LEVELS) 16" MIN. 2" HDPE SDR-11 FORCEMAIN BALL VALVE 1d a d a G e 4' DIAMETER PRECAST CONCRETE PUMP STATION WITH TRAFFIC CO AND ACCESS MANWAY INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED EXTERIOR WEATHERPROOF JUNC71ON BOX (IF NECESSARY). SEAL CONDUIT GAS 71GHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION. 1-1/2" SCH-40 PVC INSIDE WET WELL THROUGH WALL UNION — LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PUMP REMOVED WITHOUT TANK ENTRY REDUCING TEE POINTED DOWNWARD WITH 1" BALL VALVE THROTTLED TO ALLOW TRICKLE DRAIN BACK INTO WETWELL BALL CHECK VALVE DUPLEX GRINDER PUMPS PUMP STATION NOTES GRINDER PUMPS TO BE LIBERTY PROVORE 380 SERIES 1 HP RESIDENTIAL GRINDER PUMPS IN 4' DIAMETER PRECAST CONCRETE BASIN WITH TRAFFIC COVER. SEAL ALL TANK OPENINGS WATERTIGHT. PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, DEMAND DOSE CONTROL PANEL IN BASEMENT UTILITY ROOM IN COORDINATION WITH OWNER. INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.EC.) REQUIREMENTS. GRINDER PUMPS TO BE LIBERTY PROVORE PRG-102M, 23OV, 1 HP, 25 GPM ® 30 FT TDH. VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMPS. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION. 4" SCH. 40 PVC INLET MIN. SLOPE 1/4" PER FOOT WATERTIGHT SLEEVE AND SEAL (TIP.) 1,500 GALLON -- POLYETHYLENE SEPTIC TANK A POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER 15" LIQUID DEPTH 40" 12"f J. 118" LONG 6"f PEA GRAVEL 51" PUMP STATION & SEPTIC TANK DETAIL SCALE: NTS 4" TOPSOIL COVER ABOVE 4" PVC PERFORATED LATERAL INSTALLED LEVEL, FILTER FABRIC TOP OF STONE BED; IN BED CONFIGURATION WITH 5.00' PIPE 2 ' TO ED MIRAFI 140N OR EQUAL SEED &ESTABLISH TURF MANIFOLDED ENDS SPACING OF BED 8-6 . C R -----mac 2" STONE 12" TOTAL COVER OVER PIPE z'. T NE DEPTH S 0 6" MIN STONE _ BED WIDTH & GEOMETRY PER PLAN --, 2' MINIMUM BELOW PIPE SEPARATION TO BOUNDARY_ CONDITION 3/4"— —1/2" WASHED CRUSHED STONE ABSORPTION BED SECTION NTS APPROXIMATE FINISH GRADE 18" MIN. POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER TEE BAFFLE C*1411 M 12" MIN. COVER DISTRIBUTION BOX 4" SDR-35 PVC MIN. SLOPE BAFFLE 1/8" PER FOOT 2" MIN. USE SPEED LEVELERS TO ASSURE ALL OUTLETS 2" MIN. DROP ARE AT EXACTLY THE SAME ELEVATION BETWEEN INVERTS 4" PVC SDR-35 SOLID HEADER TO ABSORPTION FIELD, 1/8" PER FOOT MIN SLOPE SEPTIC TANK NOTES ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PREFABRICATED POLYETHYLENE. ALL STRUCTURES SHALL BE PLACED ON 6"t LEVEL PEA GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED UNDER PEA GRAVEL AS NECESSARY TO ACHIEVE A STABLE BASE. RUBBER GASKETS SHALL BE INSTALLED IN ALL INLETS AND OUTLETS. INSTALL, BACKFILL, & FILL TANK IN STRICT CONFORMANCE WITH TANK MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. PROVIDE COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION. 40 15' ABSORPTION BED PLAN NTS LIMIT OF 15'x4O' STONE BED 'ERFORATED PVC LATERALS ALLED NEAR LEVEL IN CONFIGURATION POSED RIBU71ON BOX 4SI TION FORCE J TO 4" PVC SIDE OF D-BOX Call Before You Dig Wait The Required Time Confirm Utility Response Respect The Marks Dig With Care 800.962.7962 www.digsafelynewyork.com IN ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A Hutchins Engineering PLLC 169 HoWand Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745— 0308 Fax AX MAP # 289.11-1- prepared for: Tryntze and Adam Conway 74 Reardon Road Town of Queensbury, County of Warren, State of New York Drawn: AVA lChoocked: GTH Scale: NOTED Date: 0310612024 292293-01-S2