Loading...
CC-0428-2022 H Office Use Only l: ADDITION/ALTERATION PERMIT Permit#: CC.,' D42to • 202 _ APPLICATION ' --�� Permit Fee:$ �1 c �A•4-0 Q Town of aeensbury 742 Bay Road,Queensbury,NY 12804 � $ Invoice#: P:518-761-8256 www.queensburv.net Flood Zone? Y Reviewed By: Al Project Location: 1066 State Route 9 - Farmstand & Flatbread Tax Map ID#: 296.9-1-10.12 Subdivision Name: �, - -•...4....,,..• D C� r.� f p W, - 1 PROJECT INFORMATION: 'laQ8 2C -2-7 ii LII ;2i / I TOWNF _i DU{LDINe � N�� UF'Y TYPE: Residential X Commercial, Proposed Use: Re'�taar-antO& etail ' Single-Family _Two-Family _Multi-Family(#of units ) _Townhouse Business Office X Retail _Industrial/Warehouse _Garage (#of cars_) — - X Other(describe Restaurant ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 2,092 2nd floor: • 2nd floor: 492 3rd floor: 3rd floor: Basement(habitable space): Basement(habitable space): Total sq ft: Total sq ft: 2,584 Scope of work to be done: Main floor- replace existing kitchen ceiling (860 SF), install new handicap accessible platform lift elevator (55 SF), replace fixtures and finishes in existing toilet rooms (372 SF) replace existing wood beam and wood posts along bar area with new steel beam and steel posts with new concrete footings and remove existing bar and construct new bar area, provide compliant handrails on existing stair (805 SF). Second floor- remove existing fitting room partitions and install new toilet rooms in the same location (492 SF). All other work is patching of materials and repainting\replacing flooring. • Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ $200,000 2. Source of Heat (circle one): X Gas Oil Propane Solar Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES X NO Explain: 4. Are there any easements on the property? X YES NO As shown on drawing C-1 SITE INFORMATION: • Is this a corner lot? _YES x NO • Will the grade be changed as a result of the construction? YES X NO • What is the water source? x PUBLIC PRIVATE WELL • What type of wastewater system is on the parcel? X SEWER PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100% of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are atrue and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ethan P. Hall -Architect\Agent for the Applicant SIGNATURE: (' A 7i7ale DATE: 7 July 2022 Addition/Alteration Application Revised January 2021 R • r .„ CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Furniture:House-North LLC - Mario Disienna Mailing-Address, C/S/Z: 1254 Route,9P, Saratog Springs NY 12866 Cell Phone: ( 518 )528-1290 `r Land Line: ( ) • Primary Owner(s): Name(s): Furniture House North LLC-Mario Disienna Mailing Address, C/S/Z: 1254 Route 9P, Saratog Springs NY 12866 Cell Phone: ( 518 )528-1290 Land Line: ( ) Email: 2 Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Rucinski Hall Architecture Contact Name(s): Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268 Email: ephall cni' nycap.rr.com Contact Person for Compliance in regards to this project: Ethan P. Hall Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268 Email: ephall a nycap.rr.com Addition/Alteration Application Revised January 2021 h HAANEN ENGI •ll I G k�`" ft- 6 /°( Sheet No. / of JUL c 8 ' .022s. j : a,0 .5 vT7o/v,'s /yr e_i fN6 TrU `C',�( - /1'10 D (F,caTotis I rk C.T::LS810:LI By /7A'D Date 6r3,PIC.-:—G90E • � /2 /�42. .9 4) (3 ) F12s r FL-a-rz GD c vrr71•S i9 C m 6 os b / Aid /G-MA C£.D w 1 Oq T rvr15E•2 G/Z 0•:-c j 7E-Sf6-v iqti0 /2,E iL j ,-(i,rF/F. I. G'i)&C) (2) .v,Ew STDc $(Jra/aPi7- c.ar.,-•-✓S 44•V (Z)/t/t 4/ FCPO 77 J6 r : a — p -T-.E?4/I/ziF_ G 04,;(N‘ Tv /f c 7.4.-4,frs"F e4iLs o 77) Ci2 D,E2 PO4 77oy o� IZ�F 6.0*D CGv v SF. 2vl4.77�4. ESi1i41474� . 3 K/t _` / rr7 FLcrd-L c-c,4l) = Zo t'S'� (1 1&") = ,3 so k/'A_ -- 5 EGo Av FL v-rrz /Jl tiiv6 f L a.2 C o 4-D = /oo r c1 = I,7S A 7 77L G-o/f i z. Z, Y ii,c_ S, z,s'Y4 ---z ` G1/,2 __ (2,5"(3cf)� = 3(01 It- fit \ S Sx 'Scleeko\\\\ = (361)C12)Z3, 76 = i 8 Z 3 `v2'1X84 (w2`Ix7G)? \AN 21 x 93 (wzix o 3) ? Goceir,14, L MD (z / )( )/ - '< �z. _ y z s- K /s5vA i 5a/c: 64.4 c 17, -L- z-,s Ks-r , vsi_ 4/ `x LI Ecru77v6 ll, - z,62 s/� a a C11-10G E 57714 i 49( `7 1). 44 ri/,,-Pe rf*.cis t lDEs/6, w/'Cz) 3' 6i4j71-c C v-ie F�uos //vo SO its; 5-t-F�(_ !!/ / Z..s r^+ / L Z L I, I r l.. 3104� 3Y=o�` �3!d.� - � F � / p44-0 -. 2,s.(3) .t 2;s -3 8(37)z ` ! ` lire* ` C-_3 • , ; j`t _ (^11.3)f- /)711 -- :"o No.81241 Orr ` 40 3= sv " 296.9-1-10.12 CC-0428-2022 'WESSto- Furniture House LLC 1111 LL 254 Bay Rd - Queei 1066 State Rte 9 •7061 Comm Interior Alterations 2584 s.f. 4 FielE HAANEN ENGINEERING Job No /6/Of Sheet No. Z of a. Subject: C4-0 Sv 7-To AiS ‘,/60/-v6 7)4 /d'.o DiFc7a-)f By D Date 6/3°(2 L i.rzS -.7r5 ..N..N., • , ' -4 fz.s 338.7 • /Y1= 338,7 (336.1)0 2 _ v13 ,i' /33 l3, 142.9)(6Z r 3 W?_ X4,Z 1/ Sn=in t'4Gti21X6Z7 ? ?/ c60v) / �= 5'w2ti (S)( T ,f )(909)4 C�EUc � ft c-c�or) / �� Ei = (334t)(Z9 )('The 19y ( 2../0) r 2 z(Zo ) / y s = 3 s : 2 1 n wt aNE FNb (epvTtt1"S D r yio8- Z0og)(zoo))-V(11'8(2°4)-(Z)(4?Iei)i '\`Zs)(3)2zo'�') ZY(a9000)(f330)(400) \ Y7l x10-1,91 ro 9 -.�/ - ` \ 2. 1F re.37Xro -2.9f43ma t 19,oss '.( (4 .7 if 4 -- l ZrS_ ( 1r385�Y10°j't'(331007X1oy) +7Yf6B8 �J� 1 „ . ��--- — /r 9Y... /vo u -fG _/ 3,77(B Xlo _.,---_ tIf4)6t I./ 0 --",eA0 wit.(.. 4g vE2 y 4ovwc y ) Do i'7- Coss -e/6,o (7 (s)( 2s4('Y0g'14 rr N L 11 ;' � avzy X�0 X =2r� GS= 38Yl(25 lag") f' a3 ' 30 Or _ � V 5E i Z'i )(7t, 7 / '/a ,vMl�, e (ok I.21 X93 l )' VC_ FLFcn rr x vs .a) 6 x2 c�vA,tis 1 - it 1—tri -6 it-o pilo-icro'r fronm.6 -W- 254 Bay Rd - Queensbury,NY 12804- Phone:518-793-7444- Fax:518-793-7061 8 i Figure 3 illustrates the recommended steps for constructing a wooden hoistway. Figure 3:Wooden Hoistway Construction-Recommended Steps RI Step 1 Step2 Pit(by others) Studs(by others) Electrical wiring and equipment (by others) � y I S - 1 t bn It � I- t i - G. 5 { 1 r Step 4 Step 5 Step 6 Drywall(by others) Door positioning Door drywall(by others) (by Savaria Concord installer) • i:" 1A-747( a. .E.A' -.., I 'i-V cli4 /4� 5 Completed`hoistway4 (7-7!-..,:;' ,' ' �j �1��---/-- a-c, qg r, --7(4 /1) 4i4( ?' a ,, z epiyy- j"�s p. if A d � � �6 -yb1, Vv • S V1504 Planning Guide Part No.000690,19-m02-2019 0 . 144(c- (s' --(4 °A/c- . o6i2eA.3---44i0 (0e5-1 PLEASE NOTE: -TY P I CA L PLAN ❑VERALL H❑ISTWAY LENGTH AND WIDTH DIMENSIONS ARE /II I»l�irr��rr�i� �A 55 3/1AY RUNNING FINISHED RUNWAY LENGTH RUNNING - RUNNING —�+ (PIT LENGTH) —► UNNIN / ~L� ORANGE _ CLEARANCE _1:3=rtr_ , : • , , TOP OF MAST 54" a w CLEAR INSIDE ^ -..--- CAB LENGTH / A IUw l .\-,1 mO Tom V m :D 5.P.40• y HZ. 2 C AftlAi,r1 A ALA!%��iA LANDING 2 Il� 30 TO Y/4" ER x i` QIJIr figu3• \zz1v7aR TO ty 1 J sP 7 4 r 4 Qli a inll z,„ G NW . . N� • LDQ z Z ,r aa,... . ct W 07a m6 PE aJ m W CO D U a Z 4 ri Z f PRELIMINARY DRAWING ONLY s.P. I DRAWING APPROVAL: CHAN E 46' NI v THIS DRAWING REFLECTS OUR INTERPRETATION OF THE INFORMATION PROVIDED BY THE CAR OPERATING PANEL DEICER ON THE ORDER FORM,THIS INFORMATION IS THE DEALER'S RESPONSIBILNV,AND IS ENa:RCFNevucn* RIUNINATE06(MM LI I THE BASS FROM WHICH TICS LIFT IS DESIGNED AND MANUFACTURED.PLEASE INDICATE THE LANDING 1 •T 1 1y REQUESTED ACNON BY CHECKING ONE OF THE FOLLOWING BOXES AND SIGNING BELOW TO 3 `r S l AUTHORIZE COMPLETION OF THIS ORDER. MI .•••• I WITH NO EXCEPTIONS /,'` ',,•• ' ':. ,4'•. • . .• ,.1.;'• -Tr •ACTURE PRODUCT AS PER DRAWING ® ® ® (/I A,L'S eA• ��'� •.•; 3" SIGNATURE DATE: '� DEPTH APPROVED WITH EXCEPTIONS, NO REAPPROVAL EL, 0,00 REQUIRED CALONDIC ONCE no DRAWS°D APPROVED,ADR CwoEUASON EMS•91.APPLY EMERGENCY STOP t MAKE CHANGES AS NOTED,NO REAPPROVAL DRAWING REQUIRED E L.EVAT I 0 N B—B OFFICE USE ONL Y. Pa t No CHANGE AS NOTED, REAPPROVAL REQUIRED CMA=NMISTAw 1 V- 1 5 0 4 HALL CALL-IN FRAME MANE CHANCES AS NOTED,SEND CORRECTED DRAWING FOR MIL IOW SLAW. � � REAPPROVAL BEFORE MANUFACTURE • V"°"LN°" 3007091 2 ® CAll./SENO 1ATYONWIDE LIFTS—N.Y. 13-22 9. 62o Y GE�ERRE RRRA�GEUENT FDfSDITENA ,mm�lia/W `� C;ay.varfl , A 6. ADDNtSS: OSA=Ge w� o tr -t , C T t y 1--- ,oe"' ' 2,387 ENCLOSED VERTICAL WHEELCHAIR PLATFORM LIFT ,USA eeG 10 439 9 8 OF 5 6 V1504 Specifications Specification Specification Data Safety features Platform gate Safety underpan Door locks Safety brake Emergency stop buttons Manual lowering and battery lowering system Options Platform gate with metal insert and electric strike Top landing gate Upper/lower landing door 80"(2032 mm) Fire-rated,flush-mounted landing entrances Folding seat on platform Telephone on platform Custom color Fixed access ramp Public building package Outdoor package Automatic safety ramp on platform(for outdoor model) 24V battery backup Remote controller/pump box V1504 Planning Guide Part No.000690,19-m02-2019 5 Specifications V1504 Specifications Specification Specification Data Load capacity 750 lb(340 kg) Seat capacity 330 lb(150 kg) Maximum travel 23 ft(7 m) Nominal speed 20 ft/min(0.1 m/s) Temperature Indoor:+5°F to+122°F(-15°C to+50°C) Outdoor:-20°F to+122°F(-29°C to+50°C) Noise level(for typical installation) 72.9 dBA(up direction);50.0 dBA(down direction) Measured at a height of 1 m,distance of 1 m,in front of the motor with all panels on Daily cycle Normal:30 Heavy:75 Excessive:100 Maximum starts in 1 hour on standard installation:12 NOTE:Please consult your Sales Representative if there a chance you may exceed these amounts. Levels serviced 2(standard),3,4 Cab sizes. 36"x 48"(914 mm x 1219 mm) 36"x 54"(914 mm x 1371 mm) 36"x 60"(914 mm x 1524 mm) 42"x 48"(1067 mm x 1219 mm) 42"x 54"(1067 mm x 1371 mm) 42"x 60"(1067 mm x 1524 mm) Cab walls(height) Standard 42-1/8"(1070 mm) Optional 80"(2031 mm) Cab access Enter/exit same side(platform Type 1 L and 1 R) Front/rear access(platform Type 2) 90 degree access(platform Type 3 and 4) Power supply 120 VAC,20 A,60 Hz,single phase Motor/drive 2:1 chain hydraulic,3 Hp,gear-type motor(24 VDC) Control system Electronic-free relay logic controller Distance between 2 landings 7"(178 mm)minimum Tower Modular 8 ft(2.4 m)base guide rail assembly Roller guide support Pit depth requirement 3"(76.2 mm) Finish Beige electrostatic powder coat paint on all steel surfaces and vacuumed formed plastics Standard features 24 VDC operation Call/send stations at landings Continuous-pressure type buttons Operating control buttons on platform Automatic battery recharging system(115 VAC) Remote manual lowering device Low-voltage controls Limit switches Handrail Non-skid platform surface No machine room required Emergency stop button Part No.000690,19-m02-2019 V1504 Planning Guide to Cpot krir PROVISIONS 3Y OTHERS SPECIFICATIO\S GENERAL ELECTRICAL GENERAL POWER UNIT HOISTWAY - THE HOISTWAY MUST BE DESIGNED AND GENERAL- ELECTRICAL EQUIPMENT AND WIRING TO COMPLY WRH CLASSIFICATION: Enclosed Vertical Wheelchair Platform Uft MOTOR: 3.0 HP, 24V DC BUILT IN ACCORDANCE WITH "SAFETY STANDARD FOR SECTION 38 OF CSA C22.1 (CANADA) OR SECTION 620 OF NEC APPLIED CODE: ASME A18.1-2017 Section 2 Pub FLOW: 1.15 Gal/min(4.35L/min) PLATFORM LIFTS AND STAIRWAY CHAIRLIFTS" OR "SAFETY ANSI/NFPA 70 (USA). SPECIAL NOTE: POWER SUPPLY- 120VAC, 20A, 60HZ. 1PH CIRCUIT THROUGH A MODEL: V-1504 Shoftway or Decklift CAB FINISH Steel W Paint CODE FOR ELEVATORS AND ESCALATORS" AND ALL STATE CAPACITY: 750 lbs (341 kg) AND LOCAL CODES. FUSE DISCONNECT WITH AUXILIARY CONTACT ON MAIN POWER SUPPLY. PROVIDE TWONOMINAL SPEED: 20 fm0.102 m/s) ( 18 AWG CONDUCTORS BETWEEN CONTACT p HYDRAULIC DATA PLUMB RUNWAY - DUE TO CLOSE RUNNING CLEARANCES AND CONTROLLER. TRAVEL: 130' (3302 mm) OIL TYPE: UNIVIS 32 INDOOR OWNER/AGENT MUST ENSURE THAT HOISTWAY AND PIT LIGHTING- LIGHTING OF 100 LX MIN. AT PLATFORM AND LANDINGS. PIT DEPTH: 3" (76 mm) DEXRON ATF OUTDOOR (WHERE PROVIDED) ARE LEVEL, PLUMB (-/+ 1/8" (3 LIGHTING WITH SWITCH AND ELECTRICAL GFCI OUTLET IN PLATFORM SIZE: 36"X 54"(914 mm X 1372 mm) REQ'D: (3.79 L) mm)) AND SQUARE AND ARE IN ACCORDANCE WITH THE HOISTWAY PIT. POWER SUPPLY: 24dc120aV,20A60Hz,SINGLEPHASE GALLONSA WORKING PRESSURE: 1.0 Gall (3.717.2 MPa) DIMENSIONS ON THESE DRAWINGS, PHONE-IF A TELEPHONE CIRCUIT IS REQUIRED, JACK OR PHONE BATTERY BACK UP: up and down direction RELIEF PRESSURE: W 2500 psi( MAX. ARE PROVIDED ON THE CAR. A DEDICATED ANALOG PHONE LINE JACK UNIT MAXIMUM RELIEF PRESSURE: 2500psi (17.2 MINIMUM OVERHEAD CLEARANCE- OWNER/AGENT MUST (NO VOIP) IS REQUIRED TO BE PROVIDED BY OTHERS TO THE MPa) ENSURE MINIMUM OVERHEAD CLEARANCE IS IN CONTROLLER FOR VOID, PLEASE CONTACT SAVARIA. STROKE: 72" (1829 mm) HYDRAULIC HOSE: 1/4" (6.4 mm) ID COMPLIANCE WITH CODES. SAVARIA LINK REMOTE MONITORING - NOT APPLICABI F PLUNGER 0/D: 1.5" (38 mm) BURST: 20000 psi (137.9 MPa) Not required CYL. 0/D: 2.125' (54 mm) FITTINGS: 1/4"(6.4 mm) NPT MALE CONSTRUCTION SITE- OWNER/AGENT TO PROVIDE ALL CYL. I/D: 1.75" (44 mm) SUSPENSION CHAIN MASONRY, CARPENTRY AND DRYWALL WORK AS REQUIRED ENTRANCES CONTROLLER AND SHALL PATCH AND MAKE GOOD (INCLUDING FINISH 2X #50 ROLLER CHAIN PAINTING) ALL AREAS WHERE WALLS/FLOORS MAY UPPER LANDING GATES- WHERE REQUIRED, SMOOTH SOLID MODEL: V-1504 BREAKING STRENGTH: 7171 lbs(31.9 kN)each REQUIRE TO BE CUT, DRILLED OR ALTERED IN ANY WAY BARRIERS ARE TO BE SUPPLIED AND INSTALLED ON BOTH TYPE: CPFS SAFETY BRAKE: TYPE 'A' TO PERMIT THE PROPER INSTALLATION OF THE LIFT. SIDES OF ENTRANCE AT UPPER LEVEL AND MUST BE A QPS #: LR1390-7R2 MINIMUM OF 42' (1067 mm) HIGH. ENTRANCE ASSEMBLY AMP: 100 A 30.75'[781] DIMENSIONS- CONTRACTOR/CUSTOMER TO VERIFY ALL MUST BE IN PLACE PRIOR TO THIS PROVISION. MFR.: SAVARIA DIMENSIONS AND REPORT ANY DISCREPANCIES TO OUR FASCIA PANEL BELOW UPPER LEVEL ENTRANCE- WHERE NifilMIIIIMEMMIN OFFICE IMMEDIATELY. REQUIRED, FASCIA PANEL MUST BE FASTENED TO A SOLID 1.25'[32]oo.ss'[014 WALL AND BE PERPENDICULAR TO THE FLOOR AND WALLS. STRUCTURAL HOISTWAY FASCIA IS NOT SELF-SUPPORTING FOR LONG, 241e11 FLOOR/SUPPORT WALL LOADS- CONTRACTOR TO ASSURE CONTINUOUS RUNS VOID OF ENTRANCES. ADEQUATE MOUNTING BRACKET THAT BUILDING AND SHAFT WILL SAFELY SUPPORT ALL SUPPORT FOR THE FASCIA MUST BE PROVIDED, DOORS / GATES / CALL STATIONS LOADS IMPOSED BY THE LIFT EQUIPMENT. REFER TO THE ENTRANCE ASSEMBLIES- ENTRANCE ASSEMBLIES MUST BE LANDING 1 LANDING 2 LANDING 3 LANDING 4 LOAD DIAGRAM ON THIS DRAWING. ADJUSTED TO ALIGN WITH PLATFORM AND INTERLOCK DOOR TYPE Fire Rated Pro Door Fire Rated Pro Door EQUIPMENT, OTHERS TO ALLOW AN ADEQUATE ROUGH ENTRANCE SIDE c & a c MAST TO BE SECURELY FASTENED- WHERE REQUIRED ❑PENING. DOOR SWING Ih Ih THE MAST MUST BE SECURELY FASTENED TO THE RETURN WALLS- RETURN WALLS AT ENTRANCES MUST BE DOOR INSERT Not Applicable Not Applicable STRUCTURAL SUPPORT WALL. REFER TO WALL / FLOOR BUILT-IN BY OTHERS AFTER ENTRANCE ASSEMBLIES ARE LOCK TYPE Pro Lock(24V)Indoor only Pro Lock 24V)Indoor only SUPPORT LOAD DIAGRAM AND WALL LAG DIMENSIONS ON IN PLACE. ENTRANCE ASSEMBLY MUST BE SECURELY AUTO DOOR OPENER Pro Door Opener II/Man. Pro Door Opener II THIS DRAWING. FASTENED TO WALLS, CUSTOM DOOR WIDTH CUSTOM DOOR HEIGHT WHERE DOORS ARE REQUIRED- SUITABLE LINTELS MUST I "AST 1 IN FRAME CALL STN. yes yes ll/Send Buttons BE PROVIDED BY OWNER/AGENT, DOOR FRAMES ARE NOT PursoRti CALL STN. KEYED SIDE A SIDE C CALL STN.TYPE Call/Send Buttons CoPos. Removeable Off Pos. Removeable DESIGNED TO SUPPORT OVERHEAD WALL LOADS, ENTRANCE LOCATIONS CALL STN. STOP BUTTON noOff. no 4 CALL STN. MOUNTING Flush Mounted In Frame Rush Mounted In Frame INSULATED PRODOOR KIT No No SIDE B OPTIONS PROVIDED WALL / FLOOR SUPPORT LOAD DIAGRAM EMERGENCY PENDENT PLUG IN MANUAL LOWERING BOX WINGS: no RAMP: No Ramp Required WALL LOADING TOUCH UP PAINT: 1 can(s) EXTRA KEYS: 0 472Ibs(2.1 kN) I R2BTCACH B LTBFBUILDING: Public Building WALL FASTENERS: none KET:TWO BOLTS R3LIGHT CURTAIN: no UNDERPAN SENSOR: no ATPER BRACKET PHONE OR PHONE PLUG: No PhonePlug Ic! UNIT COLOUR: Standard Color-Almond Bige FLOOR TO FLOOD SWITCH: no FLOOR: Anti-Skid Paint (Grey) LOAD SUPPORT LOAD REMOTE MACHINE ROOM:Not required FOLD SEAT: no OF:3200lbs(14.2kN)* LOCATION: INDOOR OFFICE USE ONLYR3 oaBoiuTatxemsn 0.1 �/- 1 5 O 4 '(INCLUDES IMPACT) MILEWIEnSINE: B-$$t{ "`" 3007091 2 "'°'°'t" "�" -spown sinmoLao MO wNATrbNWIDE LIFTS-N.Y. 06 13-22, _ P O aT aVsdl MIL LOADS CALCULATED ON BASED ON ANCHOR POINTS EVERY urgtNA mm/dd/w �( �"a�® A 48' EVERY TOWER SECTION NEEDS TO BE ANCHORED. IF J ATA SHEET AUUKLas: mxam er. SPACING IS INCREASED, LOADS PER BRACKETS WILL N o - t r—e e -t , C T t y 1—G JCS No. Van Na INCREASE ACCORDINGLY. ENCLOSED VERTICAL WHEELCHAIR PLATFORM LIFT ,USA 1043998 2 OF 5 NOTES: A:) DRYWALL OR PARGING (BY OTHERS)AS REQ'D. 36" C914mm] B:) SEE DATASHEET OF THE INSTALLATION DRAWING FOR 1 ®mo LANDING ENTRANCE SCHEDULE AND RUNNING CLEARANCE. o I C:) ALL INFORMATION IS SUBJECT TO CHANGE. VISION PANEL HALL CALL = !.1 GENERAL INFORMATION: ^ (OPTIONAL) I i E - EACH LANDING ENTRANCE SHALL BE SUPPLIED AS A £ E FINISHED ASSEMBLY WITH DOOR AND FRAME BLANKED, £ £ t0 H REINFORCED, DRILLED AND TAPPED FOR ALL COMPONENTS [fJ 26 1/2" r £ N Z DETAILED, READY FOR INSTALLATION. CU C679r1ri] £ o ,N,0_ - FRAMES SHALL BE 16 GA.,FULLY WELDED CONSTRUCTION �� ® CO CU • WITH ALL WELDED JOINTS GROUND TO A SMOOTH, UNIFORM p CU CU= , FINISH Cu111 L7 — ,. �- - DOORS SHALL BE 18 GA., 2" THICK, SWINGING, FLUSH, PROLOCK CO 0 cz STEEL REINFORCED CONSTRUCTION COMPLETE WITH GLASS co WR500 OPTIONAL 3 LITE(S) AS INDICATED. co GAL LOCK Iil 176mm] ON II DOORS/FRAMES FABRICATED WITH GALVANNEALED PRODUCT 0 A40 COATED WITH PRIMER PAINT WITH SOME FACTORY (OPTIONAL) 00 (gill APPLIED TOUCH-UP. REFER TO OUR INSTRUCTIONS IN - MANUAL 000919 TO PAINT OVER THE PRIMER. I (J is - 1.5 HOURS UL/ULC LABELLED ENTRANCES PROVIDED AS ■ .�. 1111111111 INDICATED.I - AUTO DOOR: OPERATOR IS PROVIDED. [- —44" C1118rim]— I46" III ROUGHC❑PENING 44" C111S] " 4 [102] ANCHOR TO WALL I 36" E914] - FRONT VIEW (WALL NOT SHOWED) ..„. nl DRY WALL QoQ° CONCRETE ALTERNATE MOUNTING • • o • -o • o o• L 'III eIIIIJ L NAH VIM MR i90.04 v . uav No) , WM D.] , ,■� .�n:+[ arx�O o 6® ii. "IIII / •J1 1 T a 0.373 7 ■�_ AT to vC 1Pe o TIII FIVIMS `\ , I�+f' I111.111 TAA"8' - Y I]� HORIZONTAL SECTION 6" E152] °°°° OFFICE USE ONLY. Pot Na LUFT Punnnu SURFACE J MOMMHHat nur 0.1 V- 1 50 4 STRIKE JAMB)y HINGE JAMB �1°80M ATM &�� °nt N° 30070912 FIRST LEVEL D❑❑R/ C SIDH,I\1A�' NWIDE LIFTS-N.Y. 06 13-22 F REP D DOO S �UR°s NA AN C) Savaria. A LEFT HAND SWING ICI o _ tree t , C T ty L—G rOS N.. SHEET Na ENCLOSED VERTICAL WHEELCHAIR PLATFORM UFT ,USA 1043998 3 OF 5 i i illama. } , • oT T . EL.188" SP. 184 1/2" EL178 3/4" I S.P.46' EL.155 1/8" °T SR T 138 1/2" EL.131 1/8" S,P.48' D.T T . i.I I.I 11! EEL.102 1/8"_c EL91 3/4" EL94" T SP. 90 1/2" S.P. 46' #1i1N 10 T • T ' EL44 3/4"• c T o SP. 44 1 2' SP. 44 1/2" MOUNT SPAN 46' • • S.P. 46' oT • e EL11" EL; M❑UNTING BRACKET P❑SITI❑N SP: SERVICE PANEL OFF/CE USE ONL Y. Pae"a V— 1 5 O 4 afx+n&mi Mai new: 0.1 imummsum B4416 `''''"' 3007091 2 MAIM NWI D E LIFTS-N.Y. Os 13-22 q�1 LOADS CALCULATED ON BASED ON ANCHOR POINTS EVERY 48" E L EUAT G\ VIEWS �D)NA _ d/ry e sa va ria® A EVERY TOWER SECTION NEEDS TO BE ANCHORED, IF SPACING • IS INCREASED, LOADS PER BRACKETS WILL INCREASE ACCORDINGLY ENCLOSED VERTICAL WHEELCHAIR PLATFORM LIFE ,USA t r e t C i ty L_G roexa 1043998I 5T OF 5 I . 1 Site Construction Details . The V1504 needs a wall that supports a minimum of 472 lb(2100 N)of pull out force at each bolt of the bracket(two bolts per bracket).Note that the brackets come with the proper hardware to secure them in place(1/2"x 3"lag screws for wood/drywall or 1/2"x 4-1/4"anchor wedge screws for concrete walls).The floor must be capable of supporting a load of 3200 lb(14.2 kN).See Figure 1.A wall with a combination of two columns of three 2x4's,or a concrete or brick wall is required. Figure 2 details a sample wooden support wall configuration Figure 1:Wall/Floor Loading R2 R1: 260 lb (1157 N) NOTE:For R2,472 lb is at each bolt of the bracket R2: 472 lb (2100 N) (two bolts per bracket).Note that 472 lb is the Dead R3: 3200 lb (14234 N) Load plus the Live Load at Allowable Stress Design R3 levels.The Structural Engineer of Record must calculate R7 the site-specific Seismic Load and Wind Load. Figure 2:Sample Wooden Support Wall Configuration 24"(610 mm)C/C2x6 2x4 24"(610 mm)C/C 2x4 ilPil vi Finished runway length — �% Finished runway width (see plan drawings) . .'�"` (see plan drawings) �+ `-e • 24in(610mm' - �� f _-/._ C/C Anchoring �c( Hoistway must be plumb and � "�` /' 1 f 1 square,and based on dimensions Leave this section free of 4rdti ''-, { Pr , L.: shown in plan drawings studs for door installation I: Lighting `� and adjustments 'I i, /' 11 4 d 1 �./ ;,; i i . Studs(2x4) Disconnect(outside the . "` .- 1,r • '4 f ' x hoistway,not accessible :- f k‘ — to general public) , Drywall \ i{ " i . I .1. _ Waterproof pit must be provided Call/send station . I, _ - - and conform to local requirements. ,I Water drain maybe needed. +' j Concrete pit floor ' i _ �ca ableofsu supporting Electrical equipment and wiring I �_ � ,"" �, � l p pp 9 (light,electrical outlet,phone line, 4, ;-f ) .. C: a load of 3200 lb(14234 N) etc.-refer to power requirements) ' •t I+ ' iir (R3) . Power j - I 1. ly � Emergency manual " ,a3, supp l.ram lowering device (outside hoistway pit) j Leave a 3 in(76 mm)pit for platform clearance Part No.000690,19-m02-2019 V1504 Planning Guide • Fi_IRN,-t. :•.•?Ca 0.101TIC:1:IIIG AIR E-..A ASIL:ii...REPORT !4A Z,z G l'\,c- s cs: 3 i 1s / s-y^'' S ;-,aiPse r o G - `� Gzat r 3 7 ,�, 7 L7 6 3 11 f 5/1 iL y _,.. .l.i c'_,,.;(...q t,,,irS-: c'ISTRi=trr^.'3 TYPE _ _ 4fic')t3...zr..3r _ i:rc_i Reaun 1 X I ;yt•:u:S:aFssa/1 A �,-`y .-;1,C. �.,--;� , I �.-•c al:•3sd:_s I �2022 1, �' �'e+Y t 17 c,,,-G L'r L ',Yzi�t::`�: %I�.... �! . „, 1 `Its 51 -,-3 e-z y y�z2. I y.0-e -) ILL G L i/'3� r �f� �,,.>.-.. ._ 1 EV!!_A il:J..,REP OS!! r^.- P�...... :n r... . J:.r,!;1: ,;cy lei-;Ls+1 I P;�'I �i;Ft�r=-s.`7r ._.I ;s:CPAA_tu+1 I Fir.2s CFIE A41tu.ii' nc:,.7517'..Y:f U'�Y ' .,.9.:y6-2 •Ar--N IFIpX1t 1 _yJJ 1 3= Y :d?. -r.-= Yv-,-s` I F I k I-- i! c. i 3 '-� y I J`pq, t.. A"...-, IF I 6 A (,- 1 3 Z-4 -1 ,3 2S ,.a DUCT LC�CA i. :3 D 0,v c-% 6" I-- I i' c x it— I—5 2e I Zj 1' sJ St,Kiy Duc: to 7?r nzt C}"^'' - F 1 C,C IL 2.<- 1 3 Z: N L•x.:oon X Er..==',1v' - • ! I — I — I I =:::- i_ I I i 1 a_. - Pit D�t I to i!,xnu �._ 1 1 I jto_atc' X cn.r:k:? I I .. ,: Frt:,,.,rt:r.-L+i�-.lien I ii 'x'C�r', r-i r_.r + Ia-y )(LI_._I l <zS I ( t. Z; _ 1✓ :c�._ I — 1 ► — 1 — tt3st�s!.+.•":;:n rr.:tu,7 Duct 1 X I C�.�m-raS - t i AXE^ -a:9 t'-s'I;j r� ( 1 \. Tech 7' Systems Residential • Commercial • Industrial HVAC - Fire protection - Electrical (518)727-6317= CSC I V - JUN 0 3 22 .J TOWN OF QUEENSBURY 1 BUILDING&CODES , a ' .. FliSIIA'-!E'AIR CONE1ii11:%:11111-_,.:AR 6 !._ATIC 111G REPORT /k/1 k•1_.I /I -7 S — C.1_,...3 edr.F.:Li,te.ri,::,1 i.7 tr.ri/0 I- /2.-r, ') C--J''''••,- L ."`) c/ 'T,• 7 2-1. :17? St"'TE‘..PrInV.47r.:-.!4 DI i TRIE uncu if PE Sv..:,,,,Comz ,,t, 1 Sen.,:Ntyr.1),1 I 1,!;1,1,1,,,LV.1,....! I y...,,,,..1.,:ur , F 1.10&11i.10-.1,ar 7•,;,!!..(1,1n 1 A 1 7 y,,,,01 51.4,04/I 4 V:::.1.:.:-.-•-•=',1 Is ;,t C.!.A.1.t.7% N't. '....1.'0'1,7;.:-.t:C•::,...el..-::: i I Z e.-1-‘—• .1 '1,1 C-1-71 7t5 /,--)Dt<. .,11,r3 -'- - -4---1-•=,..--•Ev.,:-.:,-.K.).- fc,, 2_ -1_•>,a 1,?:•41 /-0-;•-`•- I .,,se i A.)-',C.,...i r.• ,07..1.,.‘2, P P.ALAN,-,..•43 REFv.::1-17 "10:...,,f..',-.€4-.f.:.-P.1%1:1•-'X'',:.:•!1:,-.-'•!!!*'=":•!: S'!-,-•114 L'Ous•-,L0.:-.11!:., I P.;I •:.1!A 7.-:••s-•,-., I 1:1(.1.1A Aciu.!!I F,r,a1CFIA AC:toll Ad.r.tr,..,01 WA? .---''r!•--'-''!•Pi cr IFI 161111- 1 '-2- 2-c I -3s--D I.," I' /6,..(6 I 3-Lc I .3 -1.-‹ — J.--''i:' Pyr -4- IF-71 1 0 %1 4. -,S.-S--1- 1 '. Z S. —.. t1.11:11 IC:ATV:3N 1::,15.;;_ e, P•—^ 1 c- I i I-x I 4 I ' S-..1 I 1: 1)y,..JAG" p...NJ1. lc. Lis.._y g 1.-C- I S 2< -- - --1 ..7,1•7_-:••.-a Frz,.!!• 1 I 1-1 ...-,--,,,,,,,,,• 1 1 1 I i 1 ;,•--i--...:,..•-•!.2• 1 1 1— ,--- 1 1 1 1 1 1_,..V/,"•. -,___J__ E-•:!--1--;•0-,=..!..1•:;' I t I 1 i 1 I I ..;t", -• f I , I ..,....-, I I. ..-,,--• I i I I 1 7.,..!•_.-.1-._- II 7.-.7.-!.• 1 1 I i 7,;.:::•,•• I—I Frturn Ge11.!tcr-xic3-. 1 fr 1_3-1(1.y 1_1 6 z- —c 1,0-ctic.r-.E. .'7:.....;_.:'...-0,-, I1 2.-;.. 1 k I t Ai r.•:.:, I i I I -.7. I _ .n.E•.).:,,,,17-;-,-"V. 4.!.,11-1.0:7o:00-1,;(r:.••.x..0 Ac17.:ty,..!A 01E..,,l -_-, 1 X! r,..arntrd V':,....:..%-,;-...•,1:,'.F.--24 L___1 ...-- - --,1 ,:.7,.':7707 ,.•;-7t,t1.-1:". i / 1 11 — ... .r...,:7,7,'.2,,.-:3•.•i'...!:,,...f.S.:ti.:". .".<74,;. 1-1 1_1 i 1 . r-i Tech 7 Systems Residential • Commercial • Industrial HVAC - Fire protection - Electrical . (518)727-6317 •