Loading...
1991-008 i9 CERTIFICATE OF COMPLIANCE (3A \ Liz2, TOWN OF QUEENSBURY ARREN COUNTY, NEW YORK Date /..20..-1/4QG ,4A 19 t - - This is to certify that work requested to be done as shown by Permit No. 91-008 has been completed. This structure may be occupied as a Sewage Alteration Location 45 Wintergreen OwnerDonald F. Collette By Order Town Board TOWN OF QUEENSBURY Director of Bldg. do Code Enforcement BUILDING PERMIT TOWN OF QUEENSBURY 3 No. 91-008 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to Donald F. Collette ~' OWNER of property located at 45 Wintergreen Street, Road or Ave. `s' in the Town of Queensbury,To Construct or place a Sewage Alteration N at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is Same 2. CONTRACTOR or BUILDER'S Name O Ken Collette Q 3. CONTRACTOR or BUILDER'S Address c-> 0 J fD ci- c+ 4. ARCHITECT'S Name O 5. ARCHITECT'S Address a' csi c+ CD 6. TYPE of Construction— (Please indicate by X) -5 trZ CD ( )Wood Frame ( ) Masonry ( ) Steel ( ) rD r 7. PLANS and Specifications p' rD No. Sewage alteration as per plot plan specifications and application including: One additional seepage pit 6' x 8' , #3 size stone to 8. Proposed Use CD iv Sewage alteration m 0J CD $ 25.00 PERMIT FEE PAID —THIS PERMIT EXPIRES January 15, 19 93 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the 0' town of Queensbury before the expiration date.) Dated at the Town of Queensbury this 15th Day of/ January 19 91 SIGNED BY G��✓' -� / for the Town of Queensbury Building and ZonirigtI nspector TOWN OF QUEENSBURY APPLICATIOf1 FOR SEPTIC DISPOSAL PERMIT DATE: // LOCATION OF PROPERTY FOR INSTALLATION 16 _ Arrc--oeA, 1-A jW1-4 OF QUEENSBUR Owner' s Name: pe N.62 iot_ f ila. l`!-G FRFCEWEE1 Address: r-IS(ii,"/.I�-o 1--‘4- ; /J,./ g ' " /1 7AN S 1991 Installer' s Name: /ci,u a,) /<<a G7--e_ Telephone:. 7 97 9,e7S/ BLDG. & CODE OEP 1. Number of bedrooms (residential only) 3 Total daily flow (compute @ 150 gal per bedroom) L/.5 0 Topography: Circle one: Flat Rollin Steep Slope % of Slope Soil Nature: Circle one: CLID Loam Clay Other /Depth: Ground Water: At what depth? CS Feet Bedrock or Impervious Material : At what depth? /V Feet Percolation test: Circle one: not required required Rate - Min. Per Inch Domestic water supply: Circle one: Municipal Well Other If domestic water supply is a, we Separation: Water supply from any septic absorption feet. PROPOSED SYSTEM: Septic Tank ( ,e,j,.2�rirz gal . (minimum size: 1,000 gal ) TILE FIELD: Each Trench /feet/Total system length feet EEPAGE PIT(S): Number of / /Size each 6 feet er\JAY 2 feet Size of stone to be used #. 5 /Depth or Thickness feet ***************************** HOLDING TANK SYSTEM IF REQUIRED NO. of Tanks Size of Each Gal . *Alarm system and associated electrical work to be inspected by an approved agency. I have read the regulation on the reverse side of this sheet and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. SIGNATURE OF RESPONSIBLE PERSON' C-1// 4Y/ DATE: /- -9/ 1 Septic System Inspections: • A. All applications for septic system installation, alteration or repair, as required by the 'Town of Queensbury Sanitary Sewage Ordinance, shall • be submitted to the Building Department at least 24 hours before start • • of construction and shall include a plot plan showing: 1.) the proposed location of the system 2.) location and distance to lot lines • 3.) location and distance to structures 4.) location and distance to any water supply 5.) size and dimensions of all tanks, distribution boxes, tile fields and/or drywalls B. Nu system shall be covered before inspection and approval by the Building Inspector. Failure to comply with this requirement may . result in the uncovering of the system by the installer and a fine of up to $250.00. C. An approved copy of the plot plan shall be available on the construction site. Failure co produce said plot plan at time of inspection may result in an immediate work stoppage. D. Should unforeseen problems during construction prevent proper installa— tion, alteration or repair of an approved system, a new proposal must be submitted to the Queensbury Building Department before further construction. -Town of Queensbury • BUILDING and CODES DEPARTMENT Bay and Haviland Roads • Queensbury, New York 12804 • k6niarks: c_7 Cokr\%Pft\I (' � _Down of Queeniburty I, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 • Queensbury, New York 12801 SEPTIC DISPOSAL SYSTEM INSPECTIOON NAME r _ s "�'� 1\k1CJ LOCATION 5 i c\ y Y'esvy\ DATE ri? / S.- PERMIT NO. 9J -- CJ �3 SOIL TYPE - Sand Loam - Clay - Percolation Test Required? YES 7 '0 Percolation rate - Min/Inch ,f ' TYPE of SYSTEM: Absorption field, total leng�`� Length of each trench ' , Depth of trenches � 1 Size of gravel h, i / SEEPAGE PITS{Number of) ' ( /i1 Ct-1,7, ;) l� Size- ft. X ' ft 1). 4 y mac.. Gravel size .3 V PIPING: Size Type Bldg. to tank 14 tO VL Tank to dist. box 1 tr Dist. box to field/. ' c( Openings sealed? , YES \NO Partial LOCATION/SEPARATIONS: a Foundation to tank Ea 75)‘ ft. Foundation to absorption S-j ft. . Absorption to lc t line ----lift. Separation 'of pits eft, LOCATION OF SYSTEM.ON RROPERTY(bircle one) Front - Rear/- -Left sid - Right\side - COMMENTS: �, -- �\ a 4`t • • • SYSTEM 'USE APPROVED YES N . Buildin nspector 01/86 and vl .own o/ Queenitur, BUILDING and ZONING DEPARTMENT Bay and Haviland Road, R.D. 1 Box 98 Queensbury, New York 12801 • SEPTIC DISPOSAL SYSTEM INSPECTION NAME ,.47-zeziz.-77 ��zC� LOCAT ION - 3- DATE/// /9/ PERMIT NO. 9/ 1 SOIL TYPE - -and - Loam - Clay - • Percolation Required? YES - NO Percolation rate - Min/Inch TYPE of SYSTEM: • Absorption field, total length Length of each trench' Depth of t -nches Size of grai'el_ SEEPAGE PIT N •-r of) • Size- ft`. X _$ ft. Gravel size PIPING: Size Type Bldg. to to Tank to di-' . ".ox 1 L� Dist. box to fi`-ld/r.'- y, PC/CJ ON Openings sealed:', NO Partial LOCATION/SEPARAT DNS: Foundation to tan • ft. • Foundation to absorption _ LJQ ft. Absorption to lot line Separation of pits ? ft. LOCATION • SYSTEM ON• PROPERTY(circle one) Front - - Left side - Right side - COMMENT . 6k Cod • ..„„„ • SYSTEM USE APPROVED YE N B lding spector 01/86 and vl .•., -- __.------- JAI .--' N OF QU ENSBUR --- RF.,ettivr-) ' .. .,.. / JAN 8 1991 I . BLDG. & CODE DEPT. 1 a I . I . ..N.\ • ) t r ,3 / i " ,);i;\ V f / \ 04-k, / ,ortv.,, • t%/_u 93 , 1 . 1 . . , -------