Loading...
2024-0089 7 9 Office Use Only PRINCIPLE STRUCTURE y' J PERMIT APPLICATI ON Permit#: Permit Fee:$ 1188 15 Town of Queensbury _ 2 1 Se.95 742 Bay Road,Queensbury, NY 12804 *Rec Fee:$ 1000 P:518-761-8256 www.queensbury.net Invoice#: 20 -0016 -a 2G24-ZI00 Flood Zone? Y Reviewed By:O ) Project Location: (�Ic��n 3 ►r� nk_ Tax Map #: 01 - i 3 -a-bq Subdivision Name: �- *TOWN BD.RESOLUTION 385-2020:$1000 recreation fee for new dwelling)u itssingI family,-duplexes/two-family, P1111Pi ' ri 1_ - E- multiple family, apartments, condominiums,townhouses,and/or manufactured_-&tmm-odular�homeEbut not mobile homes.This is in addition to the permit fee(s). -----� 4 PROJECT INFORMATION: T V 1 r- Residential Commercial, Proposed Use: _3_ -�a Single-Family: Two-Family Multi-Family(#of units: ) 1. Custom 2. _Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) Townhouse Garage (#of cars ) Business Office Retail Hotel/Motel Industrial Heated Warehouse/Storage Building Unheated Warehouse/Storage Building Amusement Ride Other(describe: ) MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1ST floor: 57--, 1'floor: ' C7A1 2nd floor: C� 2nd floor: (3 3rd floor: C"a Total square feet: g 7� Basement(habitable space): C) Total square feet: am t. Principle Structure Packet Revised March 2022 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ .f4( 900 2. Proposed use of the building: n5,vann;Iy 1-IAA 1� 3. If Commercial or Industrial,indicate the name of the business: 4. Source of Heat: Gas Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one nerapoliance) 5. Are there any structures not shown on the plot plan? YES )( NO Explain, if yes: 6. Are there any easements on the property? YES V. NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? r 7 Acre_ b. Is this a corner lot? YES Y.. NO c.Will the grade be changed as a result of the construction? YES JC NO d. What is the water source? .1.„PUBLIC PRIVATE WELL e. What type of wastewater system is on the parcel? SEWER. PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and inconformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I,or my agents,will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a NYS licensed land surveyor of all newly constructed facilities prior to issuance of certificate of occupancy. I have read and agree to the above: PRINT NAME: laLCcl ,I\AQ,r‘Spuu, SIGNATURE DATE alb I,�y Principle Structure Packet Revised March 2022 i CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): 1 ?MSOuk FAiPir.C1z1r5 1 LC_ Mailing Address, C/S/Z: N s l',ppp j4 (',omNbvs y Y1y .) y Cell Phone: ( ) yb1- 17/3 Land Line: ( ) Email: ()cop rQ (,oc-c is r®vr- • Primary Owner(s): Name(s): 0W10 Crl l'A1 i ., 4- Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): .01.‘neo QD Ace 1 cr A Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: **Workers' Comp documentation must be submitted with this application** • ,Architect(s1/Engineer(sl: Business Name: Lon.&' LV\ Le)vnva cU /Ir P Contact Name(s): Mailing Address, C/S/Z: iAAnpriolk, 03c. (DL e.,A\,.,,�yi, Cell Phone: ( 61 P) ) '32)f 1 t '-f Land Line: ( . Email: IA) ir)Anclic.te PR y,.4_ r-r Contact Person for Compliance in regards to this project: 4 )rLcu Atone-nu 1, Cell Phone: ( 5(P) ) Lfh 1- 17 P Land Line: ( ) Email: /Noe_ C Oc2_F Principle Structure Packet Revised March 2022 Office Use Only Q � Permit#: 2-021-k OCiefli Town- ofCZcensiurr Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.ciueensbury.net Invoice#: Flood Zone? Y N Reviewed By: SEPTIC DISPOSAL PERMIT APPLICATION Project Location: a'-( A-k6r-kn ..i r` ®k - Tax Map#: 301 - 13-- a-b RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed?(circle one) 1981-1991 130 Spa or Hot Tub Yes No Installed?(circle one) 1992-Present 110 3 I\o 33C> PARCEL INFORMATION: Topography 4.. Flat Rolling Steep Slope %Slope Soil Nature -4 Sand _Loam Clay Other, explain: • Groundwater At what depth? ybA Bedrock/Impervious At what depth? material Domestic Water Supply .Municipal _Well _Lake (if well or lake,water supply from any septic system absorption is ft.) Percolation Test Rate: per-minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size try gallons(min.size 1,000 gallons,add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length i<-o ft.; Each Trench -50 ft. Seepage Pit w/#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? :tank size ; #of tanks NOTES: 1.Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved.The installed system must match the septic layout on file—no exceptions. 3.As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. Principle Structure Packet Revised March 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): C1n(,X1n5 Fit ed mot J'Jc,ur,.�-iN� Contractor Trade: r,-erne ktnn Mailing Address,C/S/Z: 5'-c /10,16 I-kt&r{xr,n %ul)A NA`1 J aFaM Cell Phone:_( ) Land Line: _( ?Sri) ) 7Y7-9 11 Email: C 1artFr`,��( rn� aoccewA-?t . r_WM. **Workers' Comp documentation must be, submitted with this application** • Engineer(s): Name(s): WQThi- Lotty.c .Qw P. E. Mailing Address, C/S/Z: a-f7 Aker,AuLt, 39- l by Cell Phone:_( ) -A-2)S3,- &htf Land Line: _( ) Email: tt?]si.n.5aclue ec VG.lncr) Cr, v\ Contact Person for Compliance in regards to this project: ()Paw i1lok9irtleg Cell Phone: ( 616 ) 1-ft01_1713 Land Line: ( ) Email: Di;L U C^r)Cr-F Cc,r Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: i t) A41(010 SIGNATURE: DATE: ,� ?1,).y Principle Structure Packet Revised March 2022 • ( Office Use Only f; •�._��,: Permit#: 2•07-46C-0fl " 1 Town.of Qucensbury Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 • P:518-761-8256 www.queensburv.net invoice#: FUEL BURNING APPLIANCE& CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE**� Project Location: a.4 la-tpyln viA.t r• lJ _ Tax Map ID #: 30). I 3-a-uR Room of Install: I!O-C.AA- l2COM Planned Install Date: "IMr.f WW1 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _jFireplace Insert Fireplace Fuel Fired Equipment(Garage Only, 18" clearance per IMC 304.3) Fireplace,factory built** (**Manufacturer's name: eJ •-- ( l•t) Model#: 'bC.7 ) SOURCE OF HEAT: Wood Coal Pellet Gas CHIMNEY INFORMATION: Masonry(require plans to be submitted): block brick stone Flue: tile steel size, in inches SC Material*: double-wall triple-wall insulated (*Manufacturer's name: Model#: ) Prindole Structure Packet Rn.,k ,1 M.rrh,n99 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Installer/Builder:Workers'Comp documentation must be submitted with this application Contact Name(s): A()xo.-4-r?i,A Foy lot a + -in id- Contractor Trade: Mailing Address,C/S/Z: 1-13-7 �►�1c'.. �u,���ia�� jw i v -(1,1 Cell Phone:_( ) Land Line: _( 64£) T 680 Email: Contact Person for any questions regarding this project: CYLuin JUIC-,n, Cell Phone: ( -cff, .Lfhl- 17 i') Land Line: ( ) Email: ( C,a_ CI coi,cp,F to ADDITIONAL INFORMATION: 1. Two(2) inspections are required.A rough-in inspection,prior to installation and a final inspection,after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24)hour notification is required for inspections. 5. Workers'Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: CCuJ - aknfOkiDt,ft SIGNATURE: DATE: p1ahy Prindple Structure Packet Revised March 2022 • Office Use Only Permit#: ' ' -oat Town of Queensbury Permit Fee:$ 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.aueensbury.net Invoice#: FUEL BURNING APPLIANCE & CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE* Project Location: A n 5.r n it_ Tax Map ID #: .3O). R--)L-1R Room of Install: �n w.:ly line-ny-‘ Planned Install Date: "Vini D� Y FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove 'Fireplace Insert Fireplace Fuel Fired Equipment(Garage Only, 18"clearance per IMC 304.3) Fireplace,factory built** (**Manufacturer's name: L' to Model#: 5L-7 ) SOURCE OF HEAT: Wood Coal Pellet 1( Gas CHIMNEY INFORMATION: Masonry(require plans to be submitted): block brick stone Flue: tile steel size, in inches Material*: double-wall triple-wall insulated (*Manufacturer's name: Model#: Principle Structure Packet Revised March 2022 • CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL 0 Check if all work will be performed by property owner only, • Installer/Builder: Workers'Comp documentation must be submitted with this application Contact Name(s): 30YO. 17_114 F,iaplatp. t 6 7c►, Contractor Trade: Mailing Address, C/S/Z: 93-7 'lpL (a 'c.-. LiA: 66 5pelAok (ly Cell Phone:_( ) Land Line: _(_ 61 68C) 9a7l, Email: Contact Person for any questions regarding this project: Or.&iyp Aiihrtyvk Cell Phone: ( i(f) ) -'Nhl- 1"J)'') Land Line: ( ) Email: efrA t CI CoC9MF_ &pot\ ADDITIONAL INFORMATION: 1. Two (2) inspections are required.A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24)hour notification is required for inspections. 5. Workers'Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: 1G.t/� XO'JL SIGNATURE: DATE: a..)a/ay Principle Structure Packet Revised March 2022 Town of Queensbury David Drell Highway Superintendent Highway 518-761-8212 Department , - . Mark De Mers 742 Bay Road—Queensbury,NY Q �� 12801 . Deputy Highway Superintendent Phone: (518) 761-8211 518-761-8210 Fax: (518) 745-4466 DRIVEWAY PERMIT DATE: a/1 i a APPLICANT NAME: TELEPHONE NO.: 6 A-Lfhi- ) ' ADDRESS TO INSPECT: a-(11-1bni- c 2 n 09 RETURN ADDRESS &EMAIL: ill 121.1,aQ ILA( 0U064,.j16y f aue_e' 60C-Z-F (r�� Applicant must show exact location and width of driveway(s) to connect to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to use (if necessary) ( ) 12" ( ) 15" ( ) 18" . ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: David Duell, Highway Superintendent Mark De Mers, Deputy Highway Superintendent 1/21/2022 Revised Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) `- Two (2)full sets of plans �" Over 1,500 sq. ft. requires engineering stamp liezi Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, <.3 cfm for windows/Tempered glass in bathrooms -pi Door schedule/Main entrance 36" door IAEmergency Escape or Bedrooms & Habitable Space �U Above-grade: 5.7 sq.ft. tei Grade: 5.0 sq. ft. 24" (h)x 20" (w) minimum -f 0 44" maximum height above door /) Window control devices 24" or less 2nd story or 72" above grade i"7 Egress window from basement 5.0 sq. ft. '11. j Floor system sizing per table 502.3.1 Yw� Residential check ERI or Prescriptive method PA- Driveway length: 300' or more-12' width required/500' or more,turnaround required • kiz ,- Foundation drainage on plans, if required — //j .j t- A -'a tz io:3 ,3,e )-1-6tr. 16 6" drop in 10' exterior grade ,jl Framing cross section for each roof line,vertical fire stopping every 10'where required/joist spans pg. 127 '(K Ice &snow shield—24"from exterior wall el Platforms at exterior doors yi Stairway headroom 6'8"; all stairs 36" width • Yj;� Stair run and rise g(11p-- Winder run and rise p(A- Spiral stairs meet requirements i rgi Smoke detectors—battery backup & proper location, interconnectedA - Bathroom fixtures—proper clearance YHall width-36"width "g5 Handrails more than four risers on open sides 7A Railing&guards>30"/basement stairs included/closed risers more than 4" in height 14 Safety glazing notes for required areas Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door �'� and closer i' Garage floor sloped tfLe4 Attic access: gasket seal & R-value equal to roof insulation 7/4 Roof over 30"—22"x 30"/Crawl spaces 18"x 24" access Continued on back 4 4 Residential Plan Review Revised October 2021. Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) Carbon Monoxide detector outside lowest sleeping area, on every level &interconnected within 15' of sleeping area Zg4 Soil test results, if required //C Septic to well or water line separation --(4 All paperwork signed Note on plans energy saving light bulbs 90% '10 Note Blower door test agency paperwork Floodplain Permit required—check map: 2 feet above flood elevation 141 Hurricane clips required 04- Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped ,P1 /l,i.- Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations 14 Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm ik5 Continuous header for garage doors to end wall Yj Chimney rain cap shown for fireplaces 1)10, Deck hold down shown not less than 4 lags and bolts per table 507.2 • • • • Residential Plan Review Revised October 2021 • • ri7' TOWN I�1Y rig. � �► QUE�ENSB1.TRY 742 Bay Road, Queeasbury,NY. 12804-5902 • • • Septic System Checklist 4iantoscaie • - Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and • • Architects;� June 30 to April15 Town Engineer for unapproved Engineers and Architects) g . All wells on property and adjacent properties shown . ,Water line shown 'mid or well 10'separation to any part of system • • ffSetback to property lines show 10'or more for any part of system • 1ASeptic tank and pump stations 10'from foundation.50'from any well/lake/wetland 10'from any waterline . t±Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required(field verification required) 16 Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each 1g Leech Field 20'from foundation 100'from any well 10:from water line M Seepage pit 150'from•well 50'from septic tank • • rilt-Seepage Pits 3-times diameter apart IASeptic tank and pump stations over 30 gallons 50'from watercourse or wetland • • 1/distance from bottom of trench or syste 24"to bedrock or mottling 36"within 1000'of Lake George • 1i6 Leech field 100'from watercourse or wetland 41-oe of mound or bottom of retaining wall.10'from property line 100'from well 20'from Foundation iftProvide'Engineer/Architect stamp for bed or design systems • . • Department of Health Approval for all mobile home park new systems Flood Plain requirements • MO 2'above established flood elevation to bottom of system • All tanks anchored or 2'above flood elevation Generated by REScheck-Web Software 0 Com liance Certificate FILE COPY p 1. Project Monsour- 2597R —�' ' Ely i �,i 1— :- {k &p , ' Energy Code: 2021 IECC -- t I �j -� I I f�f; Location: Warren County,.New York :_ 1;;.,p"4 ,w. Construction Type: Single-family -mot '; ,P•' i ' Project Type: New Construction `. , ;i Ai; -ti —n i _ �+ •;, • Conditioned Floor Area: 2,021 ft2 i I - \g`-•' � • Glazing Area 12% , _"•J i _ _- � • 108.10 : <e: Climate Zone: 6 (8499 HDD) ;,;, y _ s' . _7.;� FfSS10Nl' Permit Date: --- = g, Permit Number: f '' �; --- Co • nstruction Site: Owner/Agent: Designer/Contractor: 12804 Michael Maney Concepts&Designs. Queensbury, NY 12804 5187448245 maneymi@gmail.com Compliance: Passes using UA trade-off . Compliance: 0.6%Better Than Code Maximum UA: 317 Your UA: 315 _ The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. • It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade 'k:' assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. '.. - Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or R-Value R-Value U-Factor U-Factor UA UA Perimeter Ceiling: Flat Ceiling or Scissor Truss 2,021 49.0 0.0 0.026 0.024 53 49 Wall:,Wood Frame, 16" o.c. 2,212 21.0 0.0 0.057 0.045 107 85 Door: Solid Door(under 50%glazing) 20 0.190 0.300 4 6 Door 1: Solid Door(under 50%glazing) 20 0.150 0.300 3 6 Door 2: Solid Door(under 50%glazing) 20 0.220 0.300 4 6 Door 3: Glass Door(over 50%glazing) 33 0.250 0.300 8 10 Window:Vinyl Frame 236 0.270 0.300 64 71 Basement Wall: Solid Concrete or Masonry Wall height: 8.0' 1,680 0.0 16.0 0.043 0.050 72 84 Depth below grade: 7.3' Insulation depth: 8.0' 301.13-2-69 2024-0089 Monsour Enterprises LLC 24 Algonquin Dr SFD w/2 gas fp 2021 s.f., Gar 576 s.f. Report date: 01/09/24 Project Title: Monsour- 2597R Data filename: Page 1 of10 Additional Efficiency Package(s) Required: 1 Proposed: 1 Description Credits Efficient Air Sealing and Ventilation Performance 1.0 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2021 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2021 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and $❑Complies 103.2 documentation demonstrate f ❑Does Not [PR1]1 energy code compliance for the j i r44; building envelope.Thermal I{ ❑Not Observable envelope and energy compliance , i❑Not Applicable path represented on construction documents. 103.1, Construction drawings and f }❑Complies 103.2, documentation demonstrate I I❑Does Not 403.8 energy code compliance for - [PR3]1 lighting and mechanical systems. ( ❑Not Observable (0) Systems serving multiple ;❑Not Applicable dwelling units must demonstrate i • compliance with the IECC Commercial Provisions. - 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]z on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr :Not Observable ;approved by the code official. ❑Not Applicable i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.2 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value. Where interior R- R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per } ❑Does Not manufacturer's instructions. kg, /❑Not Observable } i❑Not Applicable 402.2.8 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulated in accordance with ElDoes Not table for values. Table R402.1.3 with insulation depth the minimum of 10 ft [Not Observable below grade or to the basement ❑Not Applicable floor. 303.2.1 ,A protective covering is installed # 4❑Complies [F011]2 to protect exposed exterior 1 " i❑Does Not • ,O, /insulation and extends a minimum of 6 in. below grade. - [Not Observable " ❑Not Applicable 403.9 ;Snow and ice-melting system i ;❑Complies [F012]2 !controls installed to shut off i S❑Does Not ,� !system when pavement ;temperature > 50F and no ,❑Not Observable ;precipitation. _ ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3, Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 4 of10 , Section Plans Verified 'Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [1'4 [Not Observable ENot Applicable 402.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 [Not Observable [FR2]1 ❑Not Applicable 1.4.04 303.1.3 U-factors of fenestration products . ' ❑Complies [FR4]1 are determined in accordance ! - i❑Does Not with the NFRC test procedure or :taken from the default table. ❑Not Observable . ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ' - ]❑Complies [FR23]1 'installed per manufacturer's • !❑Does Not instructions. ❑Not Observable ( . , , {❑Not Applicable • 402.4.3 Fenestration that is not site built 1 11=IComplies [FR20]1 is listed and labeled as meeting t ' - ❑Does Not iv AAMA/WDMA/CSA 101/1.5.2/A440 s - ' or has infiltration rates per NFRC [Not Observable 400 that do not exceed code . - .❑Not Applicable 1 limits. t 402.4.5 ?IC-rated recessed lighting fixtures; ;, , 'j❑Complies [FR16]z sealed at housing/interior finish ' - ❑Does Not ;and labeled to indicate -2.0 cfm : ❑Not Observable leakage at 75 Pa. I ❑Not Applicable 403.3.1 Supply and return ducts in attics i - ' . ' j❑Complies [FR12]1 insulated >= R-8 where duct is $❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. ❑Not Observable LINot Applicable 403.3.4 Ducts, air handlers and filter - j❑Complies [FR13]1 boxes are sealed with i❑Does Not ( joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as ❑Not Applicable i applicable. i 4 [FO3.3.7 15]3 I ducts or plenums. - ❑Does cavities re not used as 1plies Not 'Q' IDNot Observable " ;❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 5 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.3.2 ;Ducts declared to be within the i_ - . . j❑Complies [FR28]3 conditioned space are either 1) i #❑Does Not completely within the continuous - '�J ;air barrier and within the building I❑Not Observable ' ;thermal envelope, 2) buried . , . ;❑Not Applicable ;within ceiling insulation in } ;accordance with Section j •F ' ;R403.3.6 and the air handler is - = _ I located completely within the (continuous air barrier and within . ;the building thermal envelope - • I land the duct leakage is <= 1.5 Icfm/100 square feet of ;conditioned floor area served by • ;the duct system, or 3)the ceiling I ;insulation R-value installed I • ;against and above the insulated I duct>=to the proposed ceiling ; ;insulation R-value, less the R- `value of the insulation on the j 1 403.4 I HVAC piping conveying fluids R- R- EComplies [FR17]z ;above 105 °F or chilled fluids ❑Does Not t below 55 2F are insulated to >_R- 3 ENot Observable I ENot Applicable 403.4.1 Protection of insulation on HVAC ( • }4}1=IComplies [FR24]1 piping. f S❑Does Not t 1 ❑Not Observable I❑Not Applicable 402.4.6 {Electrical and communication ; ;❑Complies [FR29]3 ;boxes installed in the thermal ( - ❑Does Not boundary of the envelope sealed t to limit air leakage between I . ENot Observable ;conditioned and unconditioned ❑Not Applicable ;spaces. 403.5.2 ;Hot water pipes are insulated to R- R- ❑Complies [FR18]2 !>_R-3. ❑Does Not 1 I ❑Not Observable ; ❑Not Applicable 403.6 ;Automatic or gravity dampers are P I❑Complies [FR19]2 ;installed on all outdoor air + f❑Does Not ;intakes and exhausts for f ❑Not Observable mechanical ventilation systems. . I s❑Not Applicable 403.6.1 ;Ventilation systems in climate `i .'❑Complies [FR30]z ;zones 7 &8 shall utilize heat or f ; ❑Does Not energy recovery f ENot Observable j ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled ❑Complies [IN13}2 iorthe installed R-values • ❑Does Not V.) i provided. ! ' :Not Observable ❑Not Applicable 402.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3)1 exterior,the exterior insulation ❑ Mass El Mass ['Not Observable l'tii requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable i 303.2 Wall insulation is installed per 11=IComplies [INC' manufacturer's instructions. 3❑Does Not ❑Not Observable 3❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel [Not Observable 402.2.E[FI1] ❑Not Applicable I 303.1.1.1, Ceiling insulation installed per •- , ' ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 1 300 ft2. . , j❑Not Observable ❑Not Applicable 402.2.3 ;Vented attics with air permeable 1 ' " *'c : j❑Complies [F122]2 :insulation include baffle adjacent ' ❑Does Not ;to soffit and eave vents that • ;extends over insulation. _ - 6 ':';, ❑Not Observable . . . ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- ❑Complies [F13]1 :insulation ?_R-value of the ❑Does Not adjacent assembly. [Not Observable ❑Not Applicable 402.4.1.3 Blower door test @ 50 Pa. <=5.0 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3.0 ach in Climate Zones 3-8. [Not Observable ❑Not Applicable 403.3.5 Ducts are pressure tested in cfm/100 cfm/100 EComplies [FI27]1 accordance with ft2 ft2 ❑Does Not ANEI/RESNET/ICC 380 or ASTME1554 to determine air ❑Not Observable leakage with either: Rough-in ❑Not Applicable test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler ;enclosure. 403.3.6 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. Duct tightness <= 8 cfm/100 ft2 for ducts within ENot Applicable thermal envelope. For rough-in tests, verification may need to occur during Framing Inspection. 403.3.4.1 Air handler leakage designated ; • : . ',;❑Complies [FI24]1 by manufacturer at<=2%of -- ,' i❑Does Not design air flow. ( iENot Observable . 3❑Not Applicable 403.1.1 Programmable thermostats i❑Complies [FI9]2 installed for control of primary ' 5❑Does Not heating and cooling systems and initially set by manufacturer to [Not Observable i • f:'' ' s - 3❑Not Applicable ,code specifications. ,. PP 403.5.1 ;Circulating service hot water ' 1❑Complies [FI11]2 (systems have automatic or - ;❑Does Not ,accessible manual controls. - IENot Observable I ]❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) -3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 8 of10 Section Plans Verified Field Verified • # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.2 ;Hot water boilers supplying heat . ",❑Complies [FI26]2 ;through one-or two-pipe heating - ❑Does Not ;systems have automatic outdoor - setback control to lower boiler [Not Observable water temperature based on ]❑Not Applicable i outdoor temperature, indoor • - temperature or water .. ;temperature sensing. ( • , 403.5.1.1 ;Heated water circulation systems 4 (❑Complies [F128]2 I have a circulation pump.The -,j❑Does Not 'system return pipe is a dedicated return pipe or a cold water supply • - - ;❑Not Observable ;pipe. Gravity and thermos- ?❑Not Applicable ;syphon circulation systems are , ;not present. Controls for circulating hot water system + ;pumps start the pump with signal - !for hot water demand within the i ;occupancy. Controls ;automatically turn off the pump } ' ' ;when water is in circulation loop I - ;;is at set-point temperature and no demand for hot water exists. . . . • • j 403.5.1.2 ;Electric heat trace systems - #❑Complies [FI29]2 `comply with IEEE 515.1 or UL l❑Does Not '515. Controls automatically Observable adjust the energy input to the `heat tracing to maintain the • ❑Not Applicable jdesired water temperature in the piping• # 403.5.3 ;Drain water heat recovery units I a ❑Complies [FI31]2 tested in accordance with CSA f '.'j❑Does Not • ;B55.1. Potable water-side l❑Not Observable pressure loss of drain water heat • ;recovery units < 3 psi for 1❑Not Applicable I individual units connected to one •• - ) ;or two showers. Potable water- { Iside pressure loss of drain water heat recovery units < 2 psi for {individual units connected to - "i. 3 ;three or more showers. 403.6.2 ;All mechanical ventilation system , l❑Complies [FI25]2 ;fans not part of tested and listed ❑Does Not I HVAC equipment meet efficacy . ❑Not Observable ;and air flow limits per Table ' , I R403.6.2. - - • ;❑Not Applicable 403.6.3 ;Mechanical ventilation systems f} ;❑Complies [F133]2 'tested and verified to meet the 1 • ;❑Does Not 'minimum flow rates required by • ;Section R403.6. 1❑Not Observable i ; 3❑Not Applicable I • 403.5.1.1.;Demand recirculation water , - ;❑Complies '1 :systems have automatic controls f ' ❑Does Not [F132]2 ;to start pump when hot water is I ,requested. ❑Not Observable ti❑Not Applicable 404.1 100%of permanent fixtures have' -l❑Complies [MPhigh efficacy lamps. ❑Does Not • ❑Not Observable . ;❑Not Applicable 404.1.2 Fuel gas lighting systems have - -. ;❑Complies [FI23]3 no continuous pilot light. 1 ' .:1❑Does Not ' ) i ' . ' . ENot Observable ,❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 9 of10 Y J Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 404.1.1 ;Exterior lighting for multifamily ' ❑Complies [FI35]3 buildings shall comply with 1 . • ❑Does Not )Section C405.4. ❑Not Observable ' ;❑Not Applicable 404.2- Permanent interior lighting shall _ , ❑Complies [FI36]3 ;be controlled with either a -: • : .❑Does Not ;dimmer, occupancy sensor or t , , - ;other control built into the ❑Not Observable ;fixture. . - ❑Not Applicable 404.3 ;Exterior lighting >= 30 watts 1 -- #❑Complies [FI37]3 ;shall have the following controls: 1 - : - - '❑Does Not i44) manual on/off switch with :. ;automatic shut-off, automatic ❑Not Observable ;shut-off in daylight hours, and ( -3❑Not Applicable i controls that override automatic • ;shutoff that returns to automatic control within 24 hours. 401.3 ;Compliance certificate posted i 1❑Complies [FI7]2 ;with building specifications and fff ❑Does Not ;compliance path and results. I . ,.• I❑Not Observable ' -I❑Not Applicable 303.3 ;Manufacturer manuals for ;❑Complies [F118]3 ;mechanical and water heating •, ,- I❑Does Not ;systems have been provided. ❑Not Observable l❑Not Applicable 408.2.5 ;Improved Air Sealing: Air leakage ❑Complies [F142]3 �<= 3.0 ACH50 combined with an ❑Does Not ;Energy Recovery Ventilator>= Latent Recovery/Moisture I❑Not Observable ;Transfer(LRMT)or Heat - - , ❑Not Applicable ;Recovery Ventilator with >= 75% Sensible Recovery Efficiency ;(SRE). ; . . . .. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Monsour- 2597R Report date: 01/09/24 Data filename: Page 10 of10 .gi2021 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 16.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.27 Door 0.25 Heating & Cooling Equipment Efficiency Heating System: Cooling System:_ Water Heater: Name: Date: Comments • ..• • _ . , ' • • tl .' , , &M ,.1 Project Summary FILE L COPY Job: - - `RONDq Date: 4 4 _•N t) Entire House By: Adirondack PBM,Inc. l►:'"`-".k Adirondack PM PO Box 582,Glens Falls,NY12801 Rom 518-7933883 Email:irfot adlrordadpmmm Pro'ect Information For. Monsour Queensbury_ � 1i`_ 1 t. k`' 4; ,_ i l!1 Nam: i \\ FEB i !-= Desi n Information Weather. Glens FallsAP,NY US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 26 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27166 Btuh Structure 13983 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btub Central vent(0 cfm) 0 Btuh (none) Humidification 0 Btuh Bloer 0 Btuh Piping 0 Btuh Equipment load 27166 Btuh Use manufacturers data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 12585 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 5980 Btuh CCeenntral vent(0 cfm) 00 Btuh Heating Coolie (none) Area(it2) 3201 3201 Equipment latent load 5980 Btuh Volume(ft3) 0 0 Air changges/hour 0.90 0.40 Equipment Total Load(Sen+Lat) 18565 Btuh Equiv.AUF(dm) 0 0 Req.Total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Amana Make Trade AMAMANAHEATING ANDAIR CONDITIO... Maker AMANA Model AMSS960402BN Cond ASX130181 D AHRI ref 7368085 Coil ACNF180616D AHRI ref 5996190 Efficiency 96.1 AFUE Efficiency 10.8 EER,13 SEER Heating input 40000 Btuh Sensible cooling 11760 Btuh Heating output 38000 Btuh Latent cooling 5040 Btuh Temperature rise 62 °F Total cooling 16800 Btuh Actual airflow 560 din Actual airflow 560 cfm Air flow factor 0.021 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.70 Calculations approved byACCAto meet all requirements of Manual J 7th Ed. wrightsofe' 2018--0ci-17 08 35:45 i9 C 1 R'igltStitetSUriversal201818.0.16 RS1121843 Page 1 ate7151Doarnerts\WrigtisofliVAOMonsotrQby.np Calc=MJ7 Front Door f s W ' P Job: Q081134cF Manual S Compliance Report Date: Sep rr,zo1a . \ Entire House By. Adirondack P&M,Inc. ��..._ Adirondack P&M PO Box562,Glens Falls,NY 12801 Phone:518-793-3883 Email:kio®adirondadptncom Project Information For: MonsourQueensbury Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 13983 Btuh Entering coil DB: 75.0°F Outdoor design WB: 70.8°F Latent gain: 5980 Bluh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 19963 Btuh Indoor RH: 50% Estimated airflow: 605 cfm Manufacturer's Performance Data*Actual Design Conditions Equipment type: SplitAC Manufacturer. Amana Model; ASX130181 D+ACNF180616D Actual airflow. 560 cln Sensible capacity: 11760 Btuh 84%of load Latent capacity: 5040 Btuh 84%of load Total capacity. 16800 Btuh 84%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 27166 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Amana Model: AMSS960402BN Actual airflow: 560 dm Output capacity: 38000 Btuh 140%of load Temp_rise: 50 °F Meets all requirements ofACCA Manual S. ' 'Wrlghtsoft^' 2018.Oct-170835:45 W.•��-.�a..�,�•.-, RigttStitetle Universal 201818A.18 RSU21843 Page 1 _.ate7151Downens1WrigtisoltHVA0MorscuQbynp Calc=MJ7 Front Door lac/etc W Specification Sheet ?, j• _; ; FLEx 100H® �SAus Heat Recovery Ventilator Product#: 44001 Fans Two[2)factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life and maintenance-free operation. v- zY;_„7a��tsrwy Heat Recovery Core t. k . ~ Aluminum heat recovery core covered by a limited lifetime warranty.Core .r ' 1 w4� ::_'p- dimensions are 8.5"x 8.5"(216 x 216 mm)with a 12"(305 mm)depth. k, y, • `Z?r�6 441" w cf ; s Our heat exchangers are designed and manufactured to withstand f • extreme temperature variations. r E fi, ,I' i'i • WinterguardTM Defrost "`� , ,,'+ }` The FLEX 100H incorporates a unique and quiet internal recirculation defrost that does not depressurize the home during the defrost cycle.A preset defrost sequence is activated when the outdoor temperature falls below 23°F(-5°Cl and automatically adjusts itself based on operating As Fantech's masterpiece of versatility,features and efficiency,the Flex conditions.The fan speed is also adjusted automatically to provide a 100H is ideal for high-rise apca-trrrent applications, condominiums, single smooth and quiet transition between Ventilation&Defrost mode. and multi family homes.With its compact top port design featuring 5 Serviceability inch oval collars and the included EZ Mount wall bracket,the Flex Core,filters,fans and electronic panel can be accesses easily from the 100H can be installed in spaces as small as 24 inches,such as a closet access panel. Core conveniently slides out with only 14"[356 mm) or maintenance room. clearance. Unlike traditional HRVs that require excessive power to meet Duct Connections supplemental ventilation needs,the compact,yet powerful Flex 100H 5"[125mm)Oval plastic duct connections with integrated balancing allows for sizing based entirely on principal ventilation requirements. damper and airflow measurement ports. With its exclusive TurboTouchlM feature,the Flex 100H can deliver up to 50%more exhaust capacity to easily meet supplemental ventilation Case needs whenever additional airflow is required. 24 gauge galvanized steel.Baked power-coated paint for a superior Fea tures adhesion and resistance. • TurboTouch function boosts exhaust capacity by up to 50% Insulation • 5"(125mm)oval duct connections with integrated airflow Cabinet is fully insulated with 1"(25 mm)high density expanded measurement polystyrene. • Removable screw terminal for easy connection filter • Lightweight:only 39 lbs(17.7 kg)including core • Super compact size Two[2l washable electrostatic panel type air filters 8.5"(216mm)x • Top port design fits in tight spaces 12.5"(318 mm)x-0.125°[3mm). • Includes EZ-Mount wall bracket Drain • Aluminum heat recovery core 1/2"(13mm)0D[outside diameter)drain spout provided,entire bottom • Multiple speed operation of unit covered by drain pan. • Internal recirculation defrost Warranty Optional Controls: Limited lifetime on aluminum core,7 year on motors,and 5 year on parts. • ECO TOUCH®r44s2sr — Programmable Touch Screen Wall Control • EDF7 (4448830 - Electronic multi-function dehumidistat • RTS2 (#401641 - 20 minute timer over-ride • RTS5 rr447g4) — 20/40/60 minute timer • MDEH1 (#401721 - Dehumidistat Specifications • Duct size - 5'(125mm)oval • Voltage/Phase — 120/1 • Power rated — 166 W • Amp — 1.4 A • Average airflow — 105 cfm[50 Vs) ®0.4"PS(100Pa) fantech .6,g ••• a systemair company D_imensions&Airflow E r_ _ _ _ -_ f -� --- lir , I l ,. CI. 1(If I! I stale air ' I 4� from inside — II.I� l.Il stale air I...---- A ------I �— B —.4 — to outside Model A 0 C 0 E F m nun iu nun in rim in inns in rum in urn Flax 100H 21 1/2 546 141/2 368 15 5/8 397 17 7/8 454 221/2 572 15 361 Dimensional information is in inches.Clearance of 14'1356nvnl in front of the unit is recommended for removal of core.All units feature three font plug•in power cord with 3-prong plug. Airflow Us) Ventilation performance 0 12 24 35 47 59 71 82 94 300 in.wg.(Pal 0.1(251 0.2(501 0.3(751 0.0(100) 0.5(125) 0.6(150) 0.7(175) 0.8(200) 12 yet;i•, zb cfm(lls) cfm(L/sl cfm(L/s) clm(Us) clm(L/s) cfm(1/s) clm(1/n) cfm(L/s) s$..f7e a�45'✓,W -,,-;t-+lr#.rr 1.0 ,:'..., 250 Net supply airflow 146(69) 1291611 116 155) 105(49) 96(45) 88(41) 80(38) 73(34l = ,3; p 1 I,t,s+h Gross exhaust airflow 1481701 1331631 1201571 107(511 95(45] 85(401 73(351 63 l301 1 0.6 -'z .. ', ,*- t'+�a i. -Y 150 6 *Turbo Mode is an intemuttent mode only.it can be activated with the RTS2.RTS5 and the ECO-Touch for up to 60 minutes. aIM. "``•=3, uyy„' -`;,iss g Only the data of the normal speed are HVI certified. `—' =;t ',sc o r.3t- ' -;;; " o 'A oA _ O, © ©:'._� O:^.'''' 100 2 02 x f.- 0 25 50 75 100 125 150 175 200 Airflow(cfm) Energy performance Sensible recovery Apparent sensible Latent rocouery/moisture Supply temperature Net airflow Consumed power efficiency effectiveness transfer Heating uF cc clm L/s W 0l0 90 - 32 0 52 24 46 70 80 -0.08 • 4 F • l,.G' fis,i L .� .q .5 1c i f iC- ur C •4 k r +t a- S " •r..,: /( d/ '" t".'t '. • 4.Wtit t_ i .:<'- ...Of:t.r,5;5.tit.;iR.t t-tc/:ti y.i.v 1.. .Y���. d:.:�!, '4.>ti �'firs_,,,,.s�:�?_'iY C..�.•'•}��k .-r�� .tin....�.4 ..� ,.rc*x,..t a.t� >,.r.. �... _ , 32 0 99 47 102 64 73 0 04 -> .tom 4 n v\i. ..i ..n p._ +. - .� 1 './,•.n.-- 1 i i X,W 4f, ._ �' ti r '�Iff.,- v r_.sd' • K : . .�., s._j-." t.'lf;. Pa _.,r C.i �, ,t. ?a s. . ..r. .:....,. -. 0` ' Requirements and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no.113 Standard applicable to ventilators • Complies with the CSA F325 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified and ENERGY STAR®qualified* ▪This product earned the ENERGY STARK by meeting strict efficiency guidelines set by Natural Resources Canada and the US EPA.It meets ENERGY SfARO requirements only when used in Canada. Contacts Distributed by: Submitted by: pate: Quantity: Model: Project#: Comments: Location: Architect: engineer: Contractor: United States 10048 Industrial Blvd.•Lenexa,KS 66215•1.800.747.1762•www.fantech.net Canada 50 Kanalfia t Way•Bouctoudre,NB E4S 3M5.1.800.5E5.3548•www.fantech.net dine comp- ���•- f a n t e e h Systenrair reserves the right to modify,at any e and without notice,any or all of its products'features,designs.comp- ��,;; nents and specifications to maintain their technological leadership position. •••••• a systemair company __ �a. la L ri \‘t.i 7' :i's ;i i \) ���Plifi.,,I.4."4,4:::;.4;0:::r7.3.,,,,\:,_ux�" • I I AUG 14 r:;2'� i iol � � 9ii; I I IT�iHl�iVNORF{�iQUEEv 3 ;t1{ Y- - - Ei�1�6..11�1`I C?r,4.'�..i�.�L..�J J, 0 6 `��,I! 8 3 6$ 4c.// Alloy_ ESSIO, .,.. ABSORPTION FIELD: THREE ROWS OF — `— ABSORPTION TRENCH, v EACH ROW 50—FEET IN LENGTH 1,000 GALLON PRECAST SEPTIC TANK 4" TRIPLE WALL HDPE PIPE • 1V AS BUILT I — _ ii N DISTRIBUTION BOX I 0 10'-1" N 23'-3" - • .... 9 Nil slY r‘''/\ N� �Co 1.) THIS AS-BUILT HAS BEEN PREPARED WITHOUT THE / • BENEFIT OF ACTUAL SURVEY INFORMATION. THE /r DIMENSIONS SHOWN HEREON HAVE BEEN MADE WITH A N STEEL TAPE AND ACTUAL LENGTHS MAY VARY. 2.) NO FUTURE ROOF DRAINS/GUTTERS, FOOTING • DRAINS, SUMP PUMPS, COOLING WATER, BACKWASH . DRAINS, ETC. SHALL BE CONNECTED TO SEPTIC SYSTEM. 3.) CONTRACTOR IS RESPONSIBLE FOR ADJUSTING SPEED LEVELERS IN DISTRIBUTION BOX TO ENSURE EQUAL DISTRIBUTION OF EFFLUENT. 20 2\ -OCeC\ �O 1 . I 5 - Z_bq OJ M rC1r NO, 2404.00 ` bAt: JURY22, 2024 0\-5 ; 'WA5';WA';° 5°O5A, 515/,'IVI SCALD;. NO SCALD 2 - ALGO\Q., \ OAV - A5-13.,IL-1 Warren A. Longacker, 19,. \Y5 08�686 TOWN OF QU�;�15C3UFY - W fl N COU\1TY, NY This home has been professionally insulated with Owens Corning' PROPINK'L77 Loosefill Insulation (Job Site Address) Name Address 24 Algonquin Dr. city Queensbury State zip Owens Corning. PROPINK' L77 Loosefill Insulation Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required number of bags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. Specification for Open Blow Attics Coverage charts are based on a nominal net bag weight of 32 lbs. Attics ,,,, J�trfrraUrr�tr��laf��a((k���������Mrntm�r��e�fled �fa�rrr�u�U�riverag� ,Mrntttzurr���gs„, �ffnJrr�}�m1N�aght ,„ New Construction ® Retrofit ❑ �ai�e rrrkne�stesy,, rtt�ne&sttmes�,,,�� eeBag( �r�} eltiousyft 13 4.75 4.75 184.6 5.4 0.173 19 7.00 7.00 125.0 8.0 0.256 22 8.00 8.00 106.3 9.4 0.301 Number of bags 26 9.25 9.25 89.6 11.2 0.357 39 used 30 10.50 10.50 77.0 13.0 0.416 38 13.25 13.25 59.9 16.7 0.534 44 15.00 15.00 50.7 19.7 0.631 49 16.75 16.75 45.0 22.2 0.711 P Estimated R-value 20.00 20.00 35.8 28.0 0.895 of previous N/A insulation Walls IIed 7 Yr k es� fastall €7Ens iy (N�imam f a�� Word4w lghf 14 2x4 3.5 1.25 87.8 11.4 0.364 Area of coverage 15 2x4 3.5 1.45 75.7 13.2 0.423 g 1750 16 2x4 3.5 2.20 49.9 20.1 0.642 (sq.ft.) 22 2x6 5.5 1.25 55.9 17.9 0.573 23 2x6 5.5 1.35 51.7 19.3 0.619 24 2x6 5.5 1.75 40.0 25.0 0.802 Other type(s)of N/A Floors Insulation In attic alua..,,,"' parrying" Ml mU tir����������Cn�fa112d�EnSiY �%��£� GfXQ� M41 wafizgSPpY Ml t �gh4 Thfaknass{X a arr ft P r fag ,,,ffiaa�y .,,, VI*41 30 2x8 7.25 1.35 39.2 25.5 0.816 38 2x10 9.25 1.35 30.8 32.2 1.041 46 2x12 11.25 1.35 25.3 39.6 1.266 Thickness of insulation 16.75 Cathedral Ceiling y iviiiiiiiiillletlpnnSfi �Nl�%In£nrrE Col�k� �4JIffillrt3 cgs Pp�Y Ml�f ��nlght iiatalli ,,,,������Thinktl�ssX�fiks`f,Ro,Iti peY P ,,,,, ,,,f4Gpsf 30 2x8 7.25 1.35 39.2 25.5 0.816 Depth of previous 38 2x10 9.25 1.35 30.8 32.5 1.041 insulation N/A 49 2x 12 11.25 1.85 18.5 54.2 1.734 Loosefill insulations vary in thermal performance due to factors such as aging,mean temperature,settlement,convection,moisture absorption and installation variation. Convection in glass loosefill insulation installed in open attics can reduce its thermal performance in extreme winter temperatures during the heating season. Contractor Thermally Yours Date6/14/2+,alder Monsour Enterprises Date Company �.cY8d Company (Sign re) (Signature) Address 149 Plant Rd., Haftoon NY 12065 Address Phone 518-312-0859 Phone OWENS CORNING INSULATING SYSTEMS,LLC ONE OWENS CORNING PARKWAY TOLEDO,OHIO,USA43659 Pub.No.10012954-B.Printed inU.S.A.October 2016.The color PINK isaregistered ® 1-800-GET-PINK" trademarkof Owens Corning.Cc2016 Owens Corning Insulating Systems,LLC.AII www.owenscorning.com Rights Reserved. mmmmmmim anrvmoi mim U IIII� i P4l S I' fi, ( Ti 0 I111 518.832.9213 1 ryan@clearvuinspections.com 1 18 Blackberry Lane,Queensbury,NY 12804 Monsour Enterprises 41 Revere Road Queensbury, NY 12804 518.461.1713 dave@gocif.com ClearVU Inspections, performed a one-point airtightness, blower doortest on the single family dwelling at 24 Algonquin Drive,Queensbury, NY,to determine the air changes per hour on August 8,2024.The dwelling was depressurized and the testing procedure performed as per IECC- R402.4.1.2. Test conditions were as follows: Fan location - Front door 350'above sea level 1,144 CFM50 68°F outside air temperature 71°F inside airtemperature Pre-Test Baseline Building Pressure 4.1 PA -50.0 Pa testing pressure TEC DG-1000& Model 3 Fan Building Volume Calculated via architectural plans Altitude Correction Factor=(1+(.000006 x altitude))x CFM50 = n/a Results:( 1,144 CFM50 x 0.936 x 60 Minutes )/( 26,269 cubic feet) _ 2.613 ACH50 IECC-R402.4.1.2-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed atthe time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Ryan Wild ClearVU Inspections BPI IDL Certification - 5063518 Asbestos Sampling & Handling License- 879660/282890 NYS Home Inspector License- 16000085839 SITE MAP LOCATION \ not to scale Wooden Fence+ Red.: cr Pn ._, ,r slrE N Lot 127 .� 44 pera7apref 1 U Lands Now or Formerly of Hulfinger Book 6654 Page 42 301.13-2-82 DEED REFERENCE: 1. Con veyance to Monsour Enterprises, L L C by deed dated May 251 20231 filed in the Warren County Clerks Office on May 30, 2023 in Book 6794 of Deeds at page 252. MAPREFERENCES- 1. Map entitled 'Map of SecHon No. 5Land O'Pines ; prepared by Coulter cos McCormack, dated February23, 19841 filed in the Warren _ County Clerks Office on December 18, 1994k Wooden Fence T .! A " A rIRmr, c* 1. Boundary information shownhereon was compiled from map reference 1 I and an actual field survey conducted on May 11, 2023. I 2. North orientation and bearing baseperrndp reference 1. r 3. Warren County tax parcel ,301.13--2-69. f 4. 177e location of underground improvements or encroachments, if any exist, I or as shown hereon, are not certified There maybe other underground I utilities, the existence of which are unknown. Size and location of all I underground utilities must be verified by the appropriate authorities. The Underground Facilities Protective Organization must be notified prior to I conducting test borings, excavation and construction. I 5. This survey it as prepared without the benefit of an up to date abstract of ' title. KRISTIN M. DARRAH 6. Reproduction or copying of this document may be a violation of copyright 050803 law unless permission of the author and/ or copyrightholder is obtained 7 A copy of this document without a proper app�lcaf7on of d7e Surveyor embossed seal should be assumed to be an unaz authorized copy. S. Property corner monuments were not placed as r otherwise noted. �s a part of this survey unless ,d V °ONLY BOUNDARY SURVEY MAPS WITH THE SURVEYOR'S EMBO SEAL ARE GENUTNE TRUE AND CORRECT COPIES OF THE SURVEY ORIGINAL WORK AND OPINION," SSED Capped Iron Rod Found Iron Rod Found DATE I I I Lot 14,3 ( ) permapref 1 ?ds Now or Formerly ofILL Parmar I I 1V I Book 6770 Page 191 301.13-2- 70 I ► '.� I6I8V, r � Capped Iron i I RodFbund� I i I 201 I I t ! 304" _ I t h t O t proposed I p Driveway t� o Proposed House 2Op" 11 760, r i t I I t 49.3'+--1 r + I o K b I t t� t I I 14 I to I r Pl opo"d Waterline 35d, W __ I W W t Lot r per map ref. 1 I r I Area = 0.54 Acres f + I I L__ I r I --_-------- 50.T+ I Sefbacl� t --J N8307120,, W 16000' Lot125 permapref. 1 Lands Now or Formerly of Gra bo wski Book 1386 Page 74 301.13-2-68 REVISIONS RECORD/DESCRIPTION Capped Imn Rod Found I I 1 r I 6F,,4f I I I I I I f I Q) DRAFTER I UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. © 2024 Darrah Land Surveying, PLLC APPROVED: KMD DRAFTED: RjT CHECKED: KMD PROj. NO: 23098 SCALE: 1 " 20' DATE: 011,3112024 1 I 1 ZONINGREQUIREMENTS. I Zoned..................................MDR Minimum Setbacks Fron t.............................. 30' fSide................................25' Rear................................30' I ' (Zoning data is shorn for informational purpose only. It is the responsibility of the I Owner/Builder to verify all zoning I requirement and setbacks) I I I I 1 PRaAq�IINARY REVIEW Map of a Proposed Site Plan Lands Now or Formerly of Honour Enterprises, LLC TOWN OF QUEENSBURY Irk WARREN COUNTY, NEW YORK Darrah L4id Surveying, FLLC 59 Lake Avenue, kake Luzerne, New York 12846 VOIce. (518) 798-4692 br (518) 654-9416 23098-1 SHEET. 1 OF 1 PROjNO: 2.3098 SITE MAP LOCATION \ not to scale Fence APAiahause Lr. � - c1 0 o ro Lester Peg BY Ann Rd - �e'x Tr r 3 Aiq.rq,�in D, >Z s $ F y 9 r Chippewa Cir SI E f`O9uo,s lJr Chipv° 'Cir - Eehro 'ohawk Tit. - -r 7;nes.WgY v y.Wfiiapetiny E +c o- Fovsax Ln � a porost In vs Gfiotokee Ln � },M1ot9'n Dr MotSan Or �afin St z s John 9t -a a � Upper Sharmatt Ave Lot127 ti per map ref. I C U Lands Now or Formerly of Hulfinger Book 6654 Page 42 301.13-2-82 DEED REFERENCE.- 1. Conveyance toMonsourEnterprises, LLCbvdeed datedMav25,2023, filed -in the Warren County Clerks Office on Ma v 30, 2023 m Book 6794 of Deeds at page 252 MAPREFERENCES - 1. Map entitled 'Map of Section No. 5 Land O'Pines1 prepared by Coulter & McCormack, dated February 23,19841 filed in the Warren County Clerks Office on December 18,1984. 2 Map entitled 'Map of Proposed Site Plan lands now or formerly of Monsour Enterprises, LLC','prepared by Darrah Land Surveying, PLLC, dated February 26, 2024. MAPNOTES 1. Boundaryinformation shown hereon was compiled from map reference 1 and an actual field survey conducted on May 11, 2023. 2. North orientation and hearing base per map reference 1. 3. Warren County tax parcel 301.13-2-69. 4. The location of underground improvements or enc.-roachin ents, -if any exist, ores shown hereon, are not certified There may be other underground utilities, the existence of which are unknown. Size and location of all underground utilitiesmust be verged by the appropriate authorities The Underground Facilities Protective Organization must be notified prior to conducting test borings, exc a vation and construction. 5. This survey was prepared without the benefit of an up to date abstract of title. 6. Reproduction or copying of this docurnentlnay be a violation of copyright law unless permission of the authorand/ or copyrightholder is obtained. 7. A copy of this document without a proper appl , ! embossed seal should he assumed to he an uUkdf on 0f the sarvey01' S 8Property corner monuments were notplaced a�r�� �t"� otherwise noted 5 a Part Of this survey unless itONLY BOUNDARY SURVEY MAPS WITH THE SURVEYORS EMBOS G.AI . ARE GENUINE TRUE AND CORRECT COPIES OF THE SURVEY Wooden_ Fence I r i j, 1 I KRISTIN M. DARRAH 050803 1 Capped Iron Rod Found Iron Rod Found N• l 54.7 t to In I� Woad Framed House Deck s�g32:s9 � I61844 IV83°1120, W16Q00' Lot 125 per map ref. I Lands Now or Formerly of Grabowski Book 1386 Page 74 301.13-2-68 REVISIONS RECORD/DESCRIPTION Lot 143 f per map ref. 1 1 Lands Now or Formerly of I Parmar I I Book 6770 Page 191 J 301.13-2— 70 J I I 1 Capped Iron I Rod Found 1 I ravel Drive Capped Iron Rod Found I I I 1 f i I I , r I I I I I I DRAFTER UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. © 2024 Darrah Land Surveying, PLLC APPROVED KMD DRAFTED.- R, jT CHECKED: KMD PROD. NO: 23098 SCALE: 1 "=20` DATE: 0710112024 it I I r I I r t� 1 N I i fI i 1 � I I I FINAL SURVEY EY I JI I II 1 1 Asphalt Driveway 14y nii IxLLZ,'1 ' AUG 14 220024 t TO!rl� rBllY I ZONING REQUIREMENTS.• I IZoned..................................MDR I Minimum Setbacks I Front..............................30' Side...............................25' IRear................................30' 1 ' (Zoning data is shown for informational purpose only. It is the responsibility of the I Owner/Builder to verify all zoning JI requirement and setbacks) t 1 Oct Map of an As -Built l r �� 2- ^ �� Lands Now or Formerly of Monsour Enterprises, L L C TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Darrah Lazid Surveying., PLLC 23098 2 may- d 59 Lake Avenue, Luke Luzern, NOW York 12846 Nice: (518) 798-4692 SHEET 1 OF + °or (518) 654-9416 PROJNO.• 23098