WASTEWATER-SEWER\APPROVE\Conway—Replacement With Components to Well Lane House-In APA-7-1-2024
RESOLUTION APPROVING ADAM AND TRYNTZE CONWAY'S
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
RESOLUTION NO.: 12024
INTRODUCED BY:
WHO MOVED ITS ADOPTION
SECONDED BY:
WHEREAS, Adam and Tryntze Conway(Applicants)filed an application for variances from
provisions of the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136 to install a
replacement on-site wastewater system with certain of its components to be located as follows:
1. Pump station 23' from the onsite well in lieu of the required 50' setback;
2. Pump station 3' from the house in lieu of the required 10' setback;
3. Pump Station 3' from the south property line in lieu of the required 10' setback;
4. Force main 21' from the onsite well in lieu of the required 50' setback; and
5. Force main 5' from the south property line in lieu of the required 10' setback;
on property located at 74 Reardon Road in the Town of Queensbury, and
WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Town's
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
variance requests on Monday, July Is', 2024, and
WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners
within 500 feet of the subject property,
NOW, THEREFORE, BE IT
RESOLVED,that
1. due to the nature of the variances, the Local Board of Health determines that the
variances would not be materially detrimental to the purposes and objectives of this
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
objectives of any Town plan or policy; and
2. the Local Board of Health finds that the granting of the variances is necessary for the
reasonable use of the land and are the minimum variances which would alleviate the
specific unnecessary hardship found by the Local Board of Health to affect the
Applicants; and
BE IT FURTHER,
RESOLVED, that the Local Board of Health hereby approves the application of Adam and
Tryntze Conway for variances from the Sewage Disposal Ordinance to install a replacement on-site
wastewater system with certain of its components to be located as follows:
1. Pump station 23' from the onsite well in lieu of the required 50' setback;
2. Pump station 3' from the house in lieu of the required 10' setback;
3. Pump Station 3' from the south property line in lieu of the required 10' setback;
4. Force main 21' from the onsite well in lieu of the required 50' setback; and
5. Force main 5' from the south property line in lieu of the required 10' setback;
on property located at 74 Reardon Road in the Town of Queensbury and bearing Tax Map No:
289.11-1-36.
Duly adopted this I"day of July, 2024, by the following vote:
AYES
NOES
ABSENT:
169 Haviland Road
Queensbury, NY 12804
Hutchins Engineering PLLC Phone: (518)745-0307
Fax: (518)745-0308
June 12, 2024
Town of Queensbury Local Board of Health
742 Bay Road
Queensbury NY 12804
Re: Adam and Tryntze Conway— 74 Reardon Road, Glen Lake
Septic Variance
Tax Map ID: 289.11-1-36
Dear Supervisor Strough and Town Board Members:
This office represents Adam and Tryntze Conway with respect to a wastewater system installation
at their 74 Reardon Road property.
Currently, the residence is served by an antiquated single-vessel system that is within 50' of Glen
Lake.
Variance requests to the Local Board of Health are as follows:
1) 23' from the pump station to the onsite well instead of the required 50';
2) 3' from the pump station to the house instead of the required 10';
3) 3' from the pump station to the south property line instead of the required 10';
4) 21' from the forcemain to the onsite well instead of the required 50';
5) 5' from the forcemain to south property line instead of the required 10'
We respectfully request that this application be placed on the Town Board's meeting agendas for
the next upcoming meetings. Please contact me with any questions that you may have or if you
would like to perform a site visit. Thank you for your assistance with the project.
Best regards,
A
G. Thomas Hutchins, P.E.
Enclosures
Cc. Adam and Tryntze Conway
Hutchins Engineering PLLC
292293-Conway
SEPTIC VARIANCE Office Use Only
- ll I Permit#:
APPLICATION Permit Fee:$
town of Q ccn7auEy
Invoice#:
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.queensbury.net Approvals:
Submittal: 1 (one) original & 8 copies of the completed application paac�l�ag p
PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN'EMAIL0122024
SBVR•1
Section 1: EN O ,i f� ��
tp
Contact Information: 9� g E �
Property Owner(s): Adam and Tryntze Conway Owner's Agent: HUTCHINS ENGINEERING,PLLC •
Address: 73 N. Helderberg Parkway Address: 169 HAVILAND ROAD
Slingerlands, NY 12159 QUEENSBURY,NY 12804
Phone#: 518-810-3960 Phone#: 518-745-0307
Email: tryntzeconway@gmail.com; aconway1999@yahoo.com Email: thutchins@hutchinsengineering.com
Section 2:
Site Information:
Site Address: 74 Reardon Road Tax ID#: 289.11-1-36
Directions to Site: from Bay Rd turn left on Tee Hill Rd for 0.6 miles; left on Reardon Rd for 0.3 miles (on right)
Section 3:
105'(absorption field)21'(pump station)
Distance from well on property to septic system (if applicable) feet
Section 4:
Is it possible to install a conforming septic system on this property? ❑Yes No
If YES, please explain and attach a diagram:
Section 5:
Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring
properties? ❑�Yes ❑ No If NO, please explain:
Section 6:
Is the proposed system to be installed under a parking area? ❑Yes ❑■ No
Section 7:
Section of the Sanitary Sewage Ordinance from which you are seeking the variance(i.e. leaching system will be 89 ft.
from well in lieu of required 100 ft.): see plans for list
Septic Variance Application Revised December 2021
Section 8:
List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this
information from the Town of Queensbury's Assessor's Office:
North Name Seidel Family Irrevocable Trust
Address 70 Reardon Road
Tax Map ID 289.11-1-37
South Name Sharon Stephenson
Address 76 Reardon Road
Tax Map ID 289.11-1-35
East Name Jeffrey Robillard
Address 66 Hall Road
Tax Map ID 289.11-1-59.121
West Name Glen Lake
Address
Tax Map ID
Section 9:
OWNER STATEMENT
I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
74 Reardon Rd . I/We realize that putting the pump station less than the required 50 feet
from the well may increase the risk of pollution.
Owner—Print Name: Tryntze or Adam Conway
Owner—Signature:
Date: 06/12/2024
Section 10:
NEIGHBOR OR TENANT RELEASE STATEMENT(If applicable)
I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
. I/We realize that putting the well, septic tank or leaching system less than the required feet
from the may Increase the risk of pollution,
Neighbor/Tenant—Print Name:
Neighbor/Tenant-Signature: Date:
Septic Variance Application Revised December 2021
Section 11:
AUTHORIZATION AND SIGNATURE PAGE
This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site
visits, other permit responsibilities and agreement to provide documentation required.
Complete the following if the OWNER is using an Agent:
Owner's Name: Tryntze and Adam Conway
HUTCHINS ENGINEERING PLLC
Designates: as agent regarding the Septic Variance for
Site Address: 74 Reardon Road -
Tax Map #: 289.11-1-36
Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic
design,storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services
will be charged directly to the applicant.
Author'ization for.Site Visits: By signing this page and submitting the application materials attached herein,the
Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code
Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the
application submitted.
Please Note: Other permits may be required for construction or alteration activity subsequent to approval by
the Town Board of Health. It is the applicant's responsibility to obtain any additional permits.
Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated
stenographer tape record the proceedings of the meetings resulting from the application, and that the
minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy
between such record and the handwritten minutes taken by the designated stenographer,the handwritten
minutes shall be deemed the official record.
I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the
submission requirements and completed checklist:
OWNER—PRINT NAME: Tryntze or Adam Conway _-
OWNER—SIGNATURE: — DATE: 2. 'Z /
P.E.
AGENT—PRINT NAME: h mas. 1.1 InS,
AGENT—SIGNATURE: _ DATE: �..
Septic Variance Application Revised December 2021
\ Zlz
La as N/F o
en & aron
B:635 P
I28911_1_3=
I
WASTEWATER SYSTEM PLAN
SCALE: 1 "=20'
GRAPHIC SCALE
10 9 2 10 20 40
( IN FEET )
CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES
..............
/ Lands N/F of
!chard & Tina DeMarsh
S �604 B:6850 P:48 A�
� _3 3�„ 289. 1 1-1-38
150
�_..,
1 dPF
VARIANCE REQUEST SUMMARY
THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY
SANITARY ORDINANCE:
1) INSTALL PUMP STATION 23' FROM WELL IN LIEU OF REQUIRED 50'.
2) INSTALL PUMP STATION 3' FROM BUILDING FOUNDATION IN LIEU OF REQUIRED 10'.
3) INSTALL PUMP STATION 3' FROM SOUTH PROPERTY LINE IN LIEU OF REQUIRED 10'.
4) INSTALL FORCE MAIN 21' FROM WELL IN LIEU OF REQUIRED 50'.
5) INSTALL FORCE MAIN 5' FROM SOUTH PROPERTY LINE IN LIEU OF REQUIRED 101.
SITE LOCATION —/ LOCATION MAP
WASTEWATER SYSTEM DESIGN
3-BEDROOM RESIDENCE (DESIGN TO 4)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 440 GPD
PUMP STATION-4'0 PRECAST CONCRETE WITH DUPLEX
GRINDER PUMPS
SEPTIC TANK - 1500 PRECAST CONCRETE DUAL
COMPARTMENT
DESIGN APPLICATION RATE: .95 GPD/SF, BASED ON
1-5 MIN/IN PERCOLA110N RATE
ABSORPTION BED AREA REQ'D = (440 GPD)/(.95 GPD/SF)
= 463 SF
POTABLE WATER SUPPLY IS TO BE ON -SITE WELL
SYSTEM MATERIAL SPECIFICATIONS
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT.
FORCEMAIN
PIPING TO BE 1-112" SDR-11 HDPE, PROVIDE POSITIVE DRAINBACK TO PUMP STATION.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 114" PER FOOT MINIMUM SLOPE.
SYSTEM FILL
AS DESCRIBED IN "FILL MATERIAL NOTES."
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER
CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO
ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS
CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER
SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION
FIELD.
SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND
DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS.
MAP REFERENCE:
1. BASE MAP INFORMATION FROM "MAP OF A
TOPOGRAPHIC SURVEY MADE FOR TRYNTZE &
ADAM CONWAY" BY VAN DUSEN & STEVES
LAND SURVEYORS, JANUARY 17, 2024.
Dig ® Safely.
New ®York
Cali Before You Dig
Wait The Required Time
Confirm Utility Response
Respect The Marks
Dig With Care
800.962.7962
www.diguatelynewyork.com
am
ALTERATION OF THIS DOCUMENT
EXCEPT BY A LICENSED
PROFESSIONAL ENGINEER IS A
Hutchins
Engineering
PLLC
169 HoWand Road
Queensbury, NY 12804
(518) 745-0307 Phone
(518) 745-0308 Fax
AX MAP # 289.11-1-36
WASTEWATER
SYSTEM PLAN
& DETAILS
prepared for
Tryntze and Adam
Conway
74 Reardon Road
Town of Queensbury,
County of Warren,
State of New York
WASTEWATEF SYSTEM SETBACK REQUIREMENTS
STREAM, LAKE,
ZOPERTY LINE HOUSE WATERCOURSE, WELL
F WETLAND
10' 10' 50' S0'
SEPTIC TANK
ABSORPTION FIELD
10' 20' 100' 100'
Drawn: AVA Checked: OTH
Scale: NOTED Date: 0310612024
292293-01-S1
Dig ® Safely.
New AYork
CAST IRON MANHOLE COVER
W/WATER 77GHT INSERT
PRECAST CONCRETE —
RISER
4" PVC SDR-35 U I
INLET
LAG/ALARM 3" ABOVE
'PUMP ON'
LEAD PUMP ON
PUMP OFF
VOLUME OF DOSE TO
BE 60 i GALLONS
(7-8" BETWEEN ON
AND OFF LEVELS)
16" MIN.
2" HDPE SDR-11
FORCEMAIN
BALL VALVE
1d a
d
a
G e
4' DIAMETER PRECAST
CONCRETE PUMP STATION WITH TRAFFIC CO
AND ACCESS MANWAY
INSTALL FLOAT SWITCHES TO
OPERATE PUMP AND MAINTAIN
LEVELS AS INDICATED
EXTERIOR WEATHERPROOF JUNC71ON BOX (IF NECESSARY).
SEAL CONDUIT GAS 71GHT. INSTALL CONTROL PANEL IN HOUSE.
ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED
ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP
STATION.
1-1/2" SCH-40 PVC INSIDE
WET WELL THROUGH WALL
UNION — LOCATE SUCH THAT UNION
CAN BE DISCONNECTED AND PUMP
REMOVED WITHOUT TANK ENTRY
REDUCING TEE POINTED DOWNWARD WITH 1"
BALL VALVE THROTTLED TO ALLOW TRICKLE
DRAIN BACK INTO WETWELL
BALL CHECK VALVE
DUPLEX GRINDER
PUMPS
PUMP STATION NOTES
GRINDER PUMPS TO BE LIBERTY PROVORE 380 SERIES 1 HP
RESIDENTIAL GRINDER PUMPS IN 4' DIAMETER PRECAST CONCRETE
BASIN WITH TRAFFIC COVER.
SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL
WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, DEMAND
DOSE CONTROL PANEL IN BASEMENT UTILITY ROOM IN
COORDINATION WITH OWNER.
INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM
IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS
AND NATIONAL ELECTRIC CODE (N.EC.) REQUIREMENTS.
GRINDER PUMPS TO BE LIBERTY PROVORE PRG-102M,
23OV, 1 HP, 25 GPM ® 30 FT TDH.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING
PUMPS.
ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED
ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP
STATION.
4" SCH. 40 PVC
INLET
MIN. SLOPE
1/4" PER FOOT
WATERTIGHT SLEEVE
AND SEAL (TIP.)
1,500 GALLON --
POLYETHYLENE
SEPTIC TANK A
POLYETHYLENE EXTENSION TO
GRADE WITH TAMPER RESISTANT
ACCESS COVER
15"
LIQUID
DEPTH
40"
12"f
J.
118" LONG
6"f PEA GRAVEL
51"
PUMP STATION & SEPTIC TANK DETAIL
SCALE: NTS
4" TOPSOIL COVER ABOVE 4" PVC PERFORATED
LATERAL INSTALLED LEVEL,
FILTER FABRIC
TOP OF STONE BED; IN BED CONFIGURATION WITH 5.00' PIPE
2 ' TO ED
MIRAFI 140N OR
EQUAL
SEED &ESTABLISH TURF
MANIFOLDED ENDS
SPACING
OF BED
8-6
.
C R
-----mac
2" STONE
12" TOTAL
COVER OVER PIPE
z'.
T NE DEPTH
S 0
6" MIN STONE
_ BED WIDTH & GEOMETRY PER PLAN
--,
2' MINIMUM
BELOW PIPE
SEPARATION
TO BOUNDARY_
CONDITION
3/4"— —1/2" WASHED
CRUSHED STONE
ABSORPTION BED SECTION
NTS
APPROXIMATE
FINISH GRADE
18"
MIN.
POLYETHYLENE EXTENSION TO
GRADE WITH TAMPER RESISTANT
ACCESS COVER
TEE BAFFLE
C*1411 M
12" MIN. COVER
DISTRIBUTION BOX
4" SDR-35 PVC
MIN. SLOPE BAFFLE
1/8" PER FOOT 2" MIN.
USE SPEED LEVELERS TO ASSURE ALL OUTLETS 2" MIN. DROP
ARE AT EXACTLY THE SAME ELEVATION BETWEEN INVERTS
4" PVC SDR-35 SOLID HEADER TO ABSORPTION
FIELD, 1/8" PER FOOT MIN SLOPE
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT
OF HEALTH AND SHALL BE OF PREFABRICATED POLYETHYLENE.
ALL STRUCTURES SHALL BE PLACED ON 6"t LEVEL PEA GRAVEL BASE. WHERE EXISTING
SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED UNDER PEA GRAVEL
AS NECESSARY TO ACHIEVE A STABLE BASE.
RUBBER GASKETS SHALL BE INSTALLED IN ALL INLETS AND OUTLETS.
INSTALL, BACKFILL, & FILL TANK IN STRICT CONFORMANCE WITH TANK MANUFACTURER'S
WRITTEN INSTALLATION INSTRUCTIONS.
PROVIDE COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION.
40
15'
ABSORPTION BED PLAN
NTS
LIMIT OF 15'x4O'
STONE BED
'ERFORATED PVC LATERALS
ALLED NEAR LEVEL IN
CONFIGURATION
POSED
RIBU71ON BOX
4SI TION FORCE
J TO 4" PVC
SIDE OF D-BOX
Call Before You Dig
Wait The Required Time
Confirm Utility Response
Respect The Marks
Dig With Care
800.962.7962
www.digsafelynewyork.com
IN
ALTERATION OF THIS DOCUMENT
EXCEPT BY A LICENSED
PROFESSIONAL ENGINEER IS A
Hutchins
Engineering
PLLC
169 HoWand Road
Queensbury, NY 12804
(518) 745-0307 Phone
(518) 745— 0308 Fax
AX MAP # 289.11-1-
prepared for:
Tryntze and Adam
Conway
74 Reardon Road
Town of Queensbury,
County of Warren,
State of New York
Drawn: AVA lChoocked: GTH
Scale: NOTED Date: 0310612024
292293-01-S2