Loading...
2024-0313 Office Use Only SEPTIC DISPOSAL APPLICATION Permit#: 245r- o316 Town of Qucensbury fl IE Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 ::d:nTYPE: Y282 72024 L.J.) ;0 Project Location: 11 Gunn Lane TOWN OF QUEENSBUF:Y ? Y BUILDINe.&CODES CIO Reviewed By: ki\' Tax Map #: 227.17-1-15 STRUCTURE INFORMATION Garbage Grinder Yes No Year Built Gallons #of X gallons per =total daily flow Installed? ❑, ❑� Per day Bedrooms Bedroom 1980 or 150 Spa or Hot Tub n older Installed? J 1981-1992 130 1992-Present 110 2 110 220 PARCEL INFORMATION TOPOGRAPHY ✓ - Flat Rolling Steep Slope % Slope SOIL NATURE - Sand Loam - Clay . . Other, explain: GROUNDWATER At what depth:36" (mottling) BEDROCK/IMPERVIOUS MATERIAL At what depth: >44" DOMESTIC WATER SUPPLY - . Municipal . Well .✓ Lake (if well or lake, water supply from any septic system absorption is >200' feet) PERCOLATION TEST Rate: 6-7 per minute per inch (test to be completed by a licensed engineer/architect)designed to 6-7 min/inch PROPOSED SYSTEM INFORMATION TANK SIZE 1,00o gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub SYSTEM Absorption field w/#2 stone Total length ft. Each trench ft. Seepage pit w/#3 stone How many: ; Size: Alternate system Bed or other type: 15'x 30'=450 SF Holding tank system Total required capacity: ; tank size: ; # of tanks: Septic Alteration Application Revised May 2024 CONTACT INFORMATI ON: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Tyson Ruecker Mailing Address, C/S/Z: 12 Willow Creek Court Slingerlands, NY 12159 Cell Phone: 518-337-7444 Land Line: Email: • Primary Owner(s): Name(s): Ruecker Family Irrevocable Trust Mailing Address, C/S/Z: 34 Ausable Forks Albany, NY 12205 Cell Phone: Land Line: Email: U Check if all work will be performed by property owner only • Contractor: Contact Name(s): BBB Construction Inc.-Con Burke Contractor Trade: Excavation/Installation Mailing Address, C/S/Z: P.O. Box 3 Bolton Landing, NY 12814 Cell Phone: Land Line: 518-796-0329 Email: conburke.bbb@gmail.com **Workers' Comp documentation must be submitted with this application** • Engineer(s): Name(s): Hutchins Engineering PLLC Mailing Address, C/S/Z: 169 Haviland Road Queensbury, NY 12804 Cell Phone: Land Line: 518-745-0307 Email: thutchins@hutchinsengineering.com Contact Person for any questions regarding this project: Tom Hutchins Cell Phone: Land Line: 518-745-0307 Email: thutchins@hutchinsengineering.com Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. � ` PRINT NAME: fiASS r.— 1i�1 SIGNATURE: - 'A DATE: (7(2-7/2.fri-- Septic Alteration Application Revised May 2024 TOWN OF QUEENSBURY Ibp- 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist e Plan to scale a`eReceived Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and rchitects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) N All wells on property and adjacent properties shown Z.ct /� wale,-SNP, /�Nater line shown Municipal or well 10'separation to any part of system ,__________..) Setback to property lines show 10'or more for any part of system tank and pump stations 10'from foundation, 50'from any well/lake/wetland, 10'from any waterline/ ,,6Septic ti/A Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) 6/'LS Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each /46Leech Field 20'from foundation 100'from any well 10'from water line /�� Seepage pit 150'from well 50'from septic tank N li Seepage Pits 3-times diameter apart fe3 Septic tank and pump stations over 30 gallons 50'from watercourse or wetland \ .j'Distance from bottom of trench or system 24"to bedrock or mottling36';within 1000' of Lake George �� 3 Leech field 100'from watercourse or wetland 7 To Toe of mound or bottom of retaining wall 10'from property line, 100'from well, 20'from foundation -e45 Provide Engineer/Architect stamp for bed or design systems idO Department of Health Approval for all mobile home park new systems Flood Plain requirements As° 2' above established flood elevation to bottom of system r- All tanks anchored or 2' above flood elevation MAP REFERENCE: WASTEWATER SYSTEM PLAN SCALE: 1 "= 30' 1. BASE MAP INFORMATION FROM WARREN COUNTY GIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. ALL GRAPHIC SCALE LOCATIONS ARE APPROXIMATE CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR TO BEGINNING INSTALLATION. 152 7 5 15 30 60 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES. THIS IS NOT A FIELD SURVEY. 114" PER FOOT MIN. SLOPE 4" HOUSE SEWER WATERTIGHT SLEEVE & SEAL (TY'•) 16" LIQUID DEPTH 30" MIN. 60" MAX. 12" MIN. COVER LIQUID LEVEL MINIMUM 2X WIDTH MAXIMUM 4X WIDTH . e. MIN. ° EXISTING 1,000 GALLON PRECAST CONCRETE SEPTIC TANK POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER (NON —TRAFFIC AREAS) 1/8" PER FOOT MIN. SLOPE 4" EFFLUENT SEWER FLOAT SWITCHES — INSTALL INSIDE PUMP PIT IN LOCATION d ACCESSIBLE WITHOUT PIT ENTRY ALARM 3" ABOVE 'PUMP INSTALL FLOAT ON' SWITCHES To PUMP ON OPERATE PUMP AND MAINTAIN PUMP LEVELS AS OFF INDICATED d VOLUME OF DOSE TO BE 801 GALLONS SEPUC TANK & 16 MIN. 500 GALLON PRECAST CONCRETE PUMP STATION ncTATI LIMIT 15' SITE SOILS DATA TEST PIT TP-1 — 512012024 BY TOM HUTCHINS, P.E. 0-6" — TOPSOIL 6-18" — MEDIUM BROWN FINE SAND FILL 18-30" — DARK BROWN SILTY SAND 30-44" — OLIVE BROWN COMPACT SILT ROOTS TO 34" MOTTLING ® 36" BOUNDARY CONDITION 0 36" PROVIDE 36" VERTICAL SEPARATION TO BOUNDARY CONDITION WASTEWATER SYSTEM DESIGN 2—BEDROOM RESIDENCE (DESIGN FOR 3 BEDROOMS) DESIGN FLOW — 110 GPD/BEDROOM SYSTEM DESIGN FLOW — 330 GPD SEPTIC TANK — EXIST. 1,000 GALLON PRECAST CONCRETE TO BE PUMPED, INSPECTED, & REUSED IF SUITABLE. INSPECT BAFFLES. DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON 6-7 MIN/IN PERCOLATION RATE ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF) = 413 SF ABSORP77QN BED AREA PROVIDED = 15'x3O' = 450 SF POTABLE WATER SUPPLY IS TO BE ON —SITE WELL MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEP77C TANK & WELL MAINTAIN 100' MINIMUM SEPARATION BETWEEN ABSORPTION FIELD & WELL 30' AL ABSORPTION BED PLAN NIS IROPOSED IISTRIBUTION BOX TRANSITION FORCE MAIN TO 4" PVC OUTSIDE OF D—BOX Crrf= I In/`ATTnAl . _. �.........." LOCATION MAP TOWN OF QUEENSBU BUILDING & CODES DEPT. n E Reviewed By'. . LJ 7 2024 Date,. - r.11 jp TOWN OF QUEENSBURY BUILDING & CODES � �NcgURY �dJN � � �EpPR aMonNoos P ed as iN exam !` d our 11 R� d Q11 not biElcutlons ace In L� wa h out comrnelans and sneu td�n9 codes of Ind. k.,"Cl oe e '1th the Go ,tate• SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND THE MANUFACTURER ANUA'S INSTRUCTIONS. AFTER EXCAVATION OF ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. PLACEMENT OF CRUSHED STONE, PURAFLO UNITS AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE ABSORPTION BED. DISPOSAL FIELD SHALL BE GRADED TO SHED RAINFALL AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER ABSORPTION SYSTEM HAS BEEN INSTALLED. THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WI7H 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON —WOVEN SEPARATON FABRIC, TENCATE MIRAFI 14ON OR EQUIVALENT. FORCEMAIN PIPING TO BE 1-1/2" SDR-11 HDPE, PROVIDE POSITIVE DRAINBACK TO PUMP STATION. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL KITH 1/4" PER FOOT MINIMUM SLOPE. SYSTEM FILL AS DESCRIBED IN FILL MATERIAL NOTES." TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND SEPTIC TANK NOTES ESTABLISH TURF. ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW 12" MINCOVER YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST WASTEWATER SYSTEM FILL TRANSITION TO 4 . OUTSIDE CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR OF D—BOX DISTRIBUTION BOX EQUIVALENT. MATERIAL NOTES ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, AFTER REMOVING ORGANICS & TOPSOIL, PLACE SYSTEM FILL OVER THE ENTIRE CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A AREA OF PROPOSED ABSORPTION BED AND TAPER AREA. BAFFLE STABLE BASE. 1-1 2" USE SPEED LEVELERS TO ASSURE ALL 2"MIN. "ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND / SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA OR SANDY LOAM WITH IN —PLACE PERCOLATION RATE OF 3-6 MIN/INCH AND NO FORCEMAIN OUTLETS ARE AT EXACTLY THE SAME HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ORGANICS OR OBJECTS OVER 3" IN SIZE LESS THAN 10% BY WEIGHT SHALL BE ELEVATION FINER THAN 0.05mm. AT LEAST 257. OF THE MATERIAL BY WEIGHT SHALL BE IN 2"MIN. DROP ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 15Z OF THE MATERIAL BY WEIGHT BALL VALVE 4" PVC SDR-35 SOLID HEADER TO BETWEEN INVERTS THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING. SHALL BE LARGER THAN A 1/2" SIEVE. ABSORPTION LATERALS, 1/8" PER FOOT I SLOPE PUMP STATION NOTES ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE SEAL ALL TANK OPENINGS WATERTIGHT. MINIMUM OF 3—FEET BETWEEN SEASONAL HIGH GROUNDWATER (60" FROM NATIVE d PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH GRADE AT 7P-1)) AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL 1-1 2" SCH-40 PVC OR GALVANIZED PIPING INSIDE WET VISUAL AND AUDIBLE ALARM. INSTALL SIMPLEX, DEMAND DOSE CONTROL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION BED AREA AND / TAPER AREAS. WELL THROUGH WALL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION. UNION —LOCATE SUCH THAT UNION CAN BE INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN DISCONNECTED AND PUMP REMOVED WITHOUT TANK HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND 12" LIFTS WITH TRACKED EQUIPMENT PRIOR TO WSTALLA77ON OF ABSORPTION ENTRY NATIONAL ELECTRIC CODE (N.EC.) REQUIREMENTS. TRENCHES. PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO PROVIDE A 40 INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF SYSTEM FILL MATERIAL Q " BALL VALVE GALLON DOSE. PRIOR TO TRANSPORTING TO SITE REDUCING TEE POINTED DOWNWARD WITH INTO WETWELL EFFLUENT PUMPS TO BE GOULDS PUMPS WE THROTTLED TO ALLOW TRICKLE DRAIN BAD APPROVED EQUIVALENT, SUBMERSIBLE EFFLU SERIES, MODEL WE03M, OR VOLT, 1PH 'ENT PUMP 1/3 HP, 230 WASTEWATER SYSTEM SETBACK REQUIREMENTS VERIFY EXISTING ELECTRICAL SERVICE PRIOR STREAM, LAKE, CHECK VALVE TO PURCHASING PUMP. PROPERTY LINE HOUSE WATERCOURSE, WELL BALL ALL ELECTRICAL WORK TO BE INSPECTED GOULDS WE O3M PUMP OR INSPECTION AGENCY PRIOR TO START-UP 0 B P �PCSRAnC�I CAL SEPTIC TANK 10' 10' So' So' ABSORPTION FIELD 10' 20' 100' 100' EQUIVALENT EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION. IN Call Before You Dig Wait The Required Time Confirm Utility Response Respect The Marks Dig With Care 800.962.7962 www.digsafelynewyork.com x I— ;a N LA c ^ ii rt Pr M V :� un fDCD3�+ 1-& D (D � i— rt �D p CL 0 2) O Cr Ncr W @ 4 W �e of N E 062 ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Haviland Road Queensbury, NY 12804 (518) 745-0307 Phone (518) 745-0308 Fnx TAX MAP # 227.17-1 -15 �TIATA"iff SYSTEM PLAN & DETAILS prepared for: Ruecker Family Revocable Trust 11 Gunn Lane Town of Queensbury, County of Warren, State of New York Drawn: GTH/HKB Checked: GTH Scale: NOTED I Date: 512012024 22316-01 - S 1