Loading...
2024-0295 I SEPTIC DISPOSAL PERMIT Office Use Only ` y APPLICATION Permit#: P262all - 0.2g5 `y Il 1 E S. c2O Town of ucrnsbu [ TL7 !J eimit Fee:�� 742 Bay Road,Queensbury,NY 12804 JUN *OF P:518-761-8256 www.queensbury.net I e tic Varianc-? Y TOWN OF QUEENSBUR" Fl od Zone? Y BUILDING& CODES-- �� " —Wetlands? Y Reviewed By: 6/5(a) Project Location: I � � +�� ram,o�r/ Tax Map #: ', RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day _ bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) ❑_ 1 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 , , v �� Installed? (choose one) ❑ 3 i 4.je ems, PARCEL INFORMATION: Topography igFlat Rolling ❑ Steep Slope % Slope Soil Nature g Sand ❑ Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? — Bedrock/Impervious material At what depth?' Domestic Water Supply ,,Municipal ❑ Well ❑Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate: /;i14j per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size hop gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub zLi;if System Absorption field w/#2 stone Total length 17 ft.; Each Trench ':i' ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ; tank size ; # of tanks Septic Application Revised July 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): 5/Za G 1 Mailing Address, C/S/Z: 1ior I2- t L>ec(fG Cell Phone: ° `Z_' 7,Z7o7 Land Line: v-8 Email: c/ec.p.p 5 .�,e- 1,4c gig:// " • Primar n s Name(s): e r Mailing Address, C/S/Z: / 7 , f";G,l /`, coet,pri d 2 Cell Phone: _ Land Line:5) 7f-777L Email: ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Contractor Trade: --�' Mailing Address, C/S/Z: Are ;ME r� 3"..di, 'Za Cell Phone: a; 7 Zr-.... o = Land Line: Email: **Workers' Comp documentation must be submitted with this application**. • Engi Name(s): - 0 in,ccei �1 Mailing Addre,s-ss C/S/ZZZS� Cell Pho e: f;-a/7-oo y Land Line: Email: 11S- Contact Person for Compliance in regards to this project: C� Cell Phonp: Oro Land Line: M ti'_ Email:deafrO 4 I-c,,.-i )d etiC:5 r Gb ,�, Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of th own of Quee bury Sanitary Sewage Disposal Ordinance. in PRINT NAME: tt, fol,(2) SIGNATURE: - --' DATE: 1.-/7- Septic Application Revised July 2022 742 Bay Road, Queensbury,NY. 12804-5902 • • Septic System Checklist • L..Planto scale . • 4Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and • • ``A chitects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) M6All wells on property and adjacent properties shown • . 1 Water line shown Municipal or well 10'separation to any part of system • •LI .Setback to property lines show 10'or more for any part of system ' I Septic tank and pump stations 10'from foundation.50'from any well/lake/wetland 10'from any waterline `septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required(field verification required) • -L-Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each 1--( Leech Field 20'from foundation 100'from any well 10'from water line Bk-A.4sv� 1 PIA-Seepage pit 150'from•we1150'from septic tank • 1 eepage Pits 3-times diameter apart • 1 --(_ Septic tank and pump stations over 30 gallons 50'from watercourse . or wetland I distance from bottom of trench or systC1}— 'edrock or mottling 36"within 1000'of Lake George • Leech field 100'from watercourse or wetland . )l oe of mound or bottom of retaining wall•10'from property line 100'from well 20'from • Foundation ti Provide'Engineer/Architect stamp for bed or design systems • . . Department of Health Approval for all mobile home park new systems Flood Plain requirements • °2'above established flood elevation to bottom of system All tanks anchored or 2'above flood elevation NEW YORK Department STATE OF OPPORTUNITY. of Health KATHY HOCHUL JAMES V. McDONALD, M.D,, M.P.H. JOHANNE E. MORNE, M.S. Governor Commissioner Executive Deputy Commissioner May 17, 2024 TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination,compliance with our comments shall not be construA as Ryan K. Riper, P.E. � Indicating the plans and specifications ::e in FILE ..*��� RK Engineering, PLLC full compliance with the Building Codes of 225 Ruggles Rd New York State. Saratoga Springs, NY 12866 RE: Forest Park Mobile Home Court, Facility 56-6822 Replacement Onsite Wastewater Treatment Systems at Briwood Lot 18 Queensbury (T), Warren County Mr. Riper: We have this day, approved the plans and specifications for the above-referenced project. Application for this project was duly made by you on plans titled, "Forest Park—Briwood Circle Lot#18—2024 Modification," and was most recently received by this office May 2, 2024. The project includes installation of two new additional laterals to serve the 3-bedroom home, which failed due to 8 people living in the home with water meter usage of 550 GPD. The initial OWTS plans were approved 3/18/22. Approval of these plans is conditioned on the following: 1. That the proposed works be constructed in complete conformity with the approved plans or amendments thereto; 2. That all components of the proposed works be installed, operated, and maintained as per the manufacturer's specifications; • 3. That approval be granted by other agencies or municipalities have jurisdiction; 4. That the design professional inspects the construction and provides certification to this office that construction was completed in accordance with the approved plans. Certification shall also be provided to the Town Office Building and Code Enforcement. The responsibility for the design of the sanitary system lies solely with the design professional and the proper operation of the sanitary system lies solely with the owner. The purpose of the Department of Health review is for compliance with the New York State Sanitary Code and in no way guarantees proper system operation. A set of approved plans is being retained in our files. Sincerely, TOWN OF QUEENSBURY v� '(&itotaii BUILDING & GOD S DEPT. Brendan O'Connell Public Health Specialist I Reviewed y: . NYSDOH—Glens Falls District Office Date: l 77 Mohican St. Glens Falls, NY 12801 (518) 793-3893 Glens Falls District Office,77 Mohican Street,Glens Falls,NY 12801,518-793-38931gfdo@health.ny.gov cc: Rebecca Bussert, District Director, Glens Falls District Director Dan MacElrath, Glens Falls District Office Kevin Kenyon, P.E., Glens Falls District Office Joel Brown, RHP Properties John O'Brien, Town of Queensbury GENERAL NOTES: DESIGN INFORMATION * PER NYSDOH APP. 75—A(FEB 3, 2010); A 25% REDUCTION IN 1. SEE NOTE SHEET. CALL ENGINEER TO DESIGN FLOW DESIGN PERC, REQ'D LENGTH OF TRENCH LENGTH IS ALLOWED WITH USE OF GRAVELLESS CHAMBERS CLARIFY ANY DESIGN LAYOUT DETAILS. # BEDRMS GAL./DAY RATE. LATERALS WITH 1.6SF/FT OF BOTTOM AREA & VOLUME OF 7.5GAL/FT & OPEN SIDEWALLS. TABLE 6C OF NYSDOH "GREEN" HANDBOOK. 2. USE DIMENSIONS GIVEN: DO NOT SCALE I, 3 550 GAL./DAY 1-5 MPI 230'-25%*=172' DRAWINGS. forest}Park J —'� 3. ALL PERMITTING/VARIANCES TO BE OBTAINED PROPOSED INSTALLATION: NOR I I BY CONTRACTOR AND/OR PROPERTY OWNER. TRENCH SYSTEM WITH ADS HANCOR ARC 24 CHAMBERS 4, FULL TIME OR MULTIPLE CONSTRUCTION TOTAL NUMBER OF LATERALS = 5 INSPECTION Is NOT INCLUDED WITH SCOPE LENGTH OF EACH LATERAL = 35'-0" 6 RI WOOD CIRCLE OF WORK. TOTAL LENGTH OF LATERALS = 175' ------ ------------- 308.14-1-52 2024-0295 PARKING Forest Park MHC LOCATE WATER LINE AND PARKING j 18 Briwood Circle PROJECT LOCATION PLAN MAINTAIN 10' HORIZONTAL L 6' I Residential Septic Alteration NOT TO SCALE SEPARATION TO SEPTIC, TYP. I 1 I It is a violation of NYS education law for any person, unless he is acting under the direction of a licensed professional engineer, to alter any item in any way. EXISTING 3 LATERALS AT 35' I 2024 ADDITIONAL 2 Y I LATERALS ADDED. EACH.ADS HANCOR ARC 24 J a ADS HANCOR ARC 24 LOT INFORMATION: CHAMBERS. SEE DETAILS. CHAMBERS. SEE DETAILS. TAX MAP : 308.14-1 -52 o CIOI 2024 ADDITIONAL 2 LATERALS TOWN OF QUEENSBURY 00 BOX I INSTALLED DUE TO FLOWS LOT SIZE: 48.9 ACRES o _j FROM DWELLING AT 550GPD p °�w n MEASURED BY WATER METER t 1 f1 I APPROVAL STAMP / NOTES SITE INFORMATION: o I DUE TO 8 RESIDENTS. TOPOGRAPHY AT TREATMENT FIELD IS RELATIVELY LEVEL. I INSTALLER TO LOCATE A E E UNDERGROUND DWELLING SUPPLIED WITH MUNICIPAL WATER. I o UTILITIES PRIOR TO CONSTRUCTION. I NO ACTIVE NEIGHBORING WELLS NOTED/VISIBLE WITHIN 100' OF TREATMENT AREA. SOLID 4"0 SCH40 AT " I APPROVED PER FOOT, TYP. I 1000 GALLON CONCRETE I For Se`,`4'cge pispcspl TANKS WITH FILTER.SEE L5 I NE1 R.VYO ° STA LEPARTf�'?`ENTOF HEALTH SOILS INFORMATION: DETAILS.LOCATE AS FEASIBLE. PT = PERCOLA1ION TEST (LOCATIONS, SEE PLAN) WATER LINE, MAINTAIN 10' ' DTP = DEEP TEST PIT HORIZONTAL SEPARATION TO TEST PERFORMED ON 03-21-20 SEPTIC, TYP. ✓ 0^�'�� D , I ...w ., .. 0"-12" DARK SANDY TOPSOIL. I JN 17 7.j 12"-26" REDDISH BROWN SAND. ACTUAL SEPTIC COMPONENT LAYOUT I �m� a ry 26"-61° GRAY COURSE SAND MAY VARY DUE TO BURIED UTILITIES I T � €y r e NQ URY(�'�",� NO GROUNDWATER OR MOTTLING NOTED I SEPTIC REPLACEMENT DESIGN GRAVELLESS CHAMBER SOIL CONDITIONS ARE SIMILAR FOR ENTIRE MOBILE HOME PARK, OR COMPONENTS. I B III _ s 'yw .M.a_ SEVERAL TEST PITS DUG THROUGHOUT PARK WITH SIMILAR I PROJECT: FOREST PARK — FINDINGS. I LOT #18 - 2024 MODIFICATION PT #1 STABILIZED PERCOLAl10N RATE: 1:45 MPI I PT #2 STABILIZED PERCOLATION RATE: 1:40 MPI I 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) I AS—BUILT TIE—IN DIMENSIONS (FT) j ®Fj�R,y DRAWING TITLE: K o RKENGINEERINGv PLLC SITE PLAN A B C.` D 225 RUGGLES RD.,SARATOGA SPRINGS,NY SEPTIC TANK EXPOSED RISER �,, ( 518.581.3893 SCALE 1" = 20'-0" FILE NAME SITE D—BOX SEPTIC SITE PLAN d�1 NO. SUBMITTAL / REVISION APP'D. DATE DATE APRIL 2024 L1 BEGIN L1 END PLOT PLAN INFORMATION OBTAINED FROM WARREN COUNTY GIS �� s oC5 a ISSUED FOR REVIEW/APPROVAL RKR 2/2/22 REVISION 2 d 0 AND AS PURPORTED BY PROPERTY MANAGER. ,Q R t RECORD DRAWING RKR 6Jt7/22 W L5 BEGIN THIS DRAWING DOES NOT REPRESENT A LAND SURVEY AND MUST A 0795® . SHEET a a NOT BE CONSTRUED AS SUCH. �®FES5I®fit 2 2024 FLOWS AT 550GPD RKR 4/19/24 1 OF L5 END C-001 2 MOUND TOPSOIL FOR SETTLING. PROJECT NOTES: 6' SEED AND COVER WITH STRAW. DUE TO GRADE CHANGE SPACING OF 6 BURIAL DEPTH WILL VARY AND 1. SYSTEM DESIGNED IN ACCORDANCE WITH 2O10 NYSDOH APPENDIX 75-A. TYP. ABSORPTION SEE NYSDOH'S "APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS - MIN. EXCEED 24". INSTALL LATERAL TRENCHES = 6' O.C. INDIVIDUAL HOUSEHOLD sysrEMs'& "NYSDOH - (GREEN) DESIGN END VENT >3' DEEP. HANDBOOK" FOR ADDITIONAL DESIGN AND INSTALLATION GUIDELINES. NO GRAVELLESS NATIVE , GUARANTEE ON SYSTEM PERFORMANCE OR LONGEVITY. CHAMBER EARTH BACKFILL 1- 2. RECORD DRAWING BASED ON ONE SITE VISIT INSPECTION OF INSTALLED -_ _ EXPOSED COMPONENTS, NO UNEARTHING PERFORMED. ' — I=1'2" CHAMBER ICI I PROPOSED GRADE, ONE CHAMBER 3. CONSTRUCTION SHALL BE AS SHOWN ON THESE DRAWINGS AND II—II—III SLOPE TO DRAIN. IN ACCORDANCE WITH ALL NYSDOH AND SYSTEM MANUFACTURER'S HEIGHT z SEED AND MULCH. LONGITUDINAL SECTION REQUIREMENTS. 2 4. ALL WORK MUST COMPLY WITH LOCAL, STATE & FEDERAL SAFETY REGULATIONS, (NYSDOH, OSHA, NYSDOT). PERMITTING REQUIREMENTS ARE DO NOT SMEAR SOILS DURING `� INSTALL LEVEL. REMOVE THE RESPONSIBILITY OF THE OWNER. EXCAVATION. DEBRIS, RAKE FLOOR & WALLS. 5. HEAVY EQUIPMENT SHALL BE KEPT AWAY FROM THE TREATMENT FIELD. GROUND WATER, BEDROCK OR NO VEHICLES ALLOWED ON TREATMENT FIELD. IMPERMEABLE STRATA 6. SMEARED TREATMENT AREA FLOORS AND WALLS ARE TO BE RAKED. PER NYSDOH APP. 75-AFEB 3, 2010 ; A 25% SEE PLAN VIEW FOR TOTAL NUMBER AND LAYOUT OF LATERALS REDUCTION IN TRENCH LENGTH IS ALLOWED WITH USE OF 7. TREATMENT FIELD SHALL BE GRADED TO SHED RAINFALL AND TO GRAVELLESS CHAMBERS WITH 1.6SF/FT OF BOTTOM AREA ADS H A N C 0 R ARC 24 CHAMBER MODEL DIVERT SURFACE RUNOFF FROM ADJACENT AREAS. & VOLUME OF 7.5GAL/FT & OPEN SIDEWALLS. GRAVELLESS CHAMBER TRENCH TREATMENT SECTION 8. RECOMMENDATION: DOWNSLOPE OR SHALLOW WELLS SHOULD HAVE UV TREATMENT OR CHLORINATION AND FILTRATION SYSTEM INSTALLED. SCALE: NTS WELL WATER QUALITY SHOULD BE TESTED PERIODICALLY. FROM SEPTIC TANK I--T-T---------- 24" DIA 9. READILY VISIBLE WELLS ARE SHOWN ON PLANS. NOT ALL WELLS MAY BE 4" DIA. SOLID PVC I I I I I FEASIBLY LOCATED. INLET II `f A OUTLET 10. GARBAGE GRINDERS AND WATER TREATMENT SYSTEM SHALL NOT ATTACH I i''I I TO SEPTIC. NO SUMP PUMP DISCHARGE ALLOWED. LEAKING FIXTURES WILL I 1 1 I I CAUSE FAILURE OF SEPTIC SYSTEM. INLET OUTLET PROVIDE EFFLUENT FILTER. SEE NOTES. APPROVAL STAMP / NOTES INSTALL RISER & EFFLUENT FILTER (POLYLOK PL-122) It is a violation of NYS education law for any person, LOCKABLE COVER, TYP unless he is acting under the direction of a licensed 1-1 2" PRECAST professional engineer, to alter any item in any way. CONCRETE BAFFLE BACKFILL WITH CLEAN OR EQUAL BAFFLE ON—SITE MATERIAL PLACED INISHED GRADE REMOVABLE COVER IN 8 INCH LIFTS AND TAMPED EFFLUENT FILTER TOP SOIL, SEED & MULCH COVER �\ WATERPROOF SEAL \ \ \ \ �z 12" MIN 4 g POLY RISER INLET INVERT T 2" ABOVE N O INLET OUTLET INVERT OUTLET iV,md INLET - CAULKED °� CAULKED 018nS Falls L.d.:?:ilCu Ice`e JOINT z F JOINT - OUTLET 9 W QUI o SANITARY TEE W/ R TeIr tO mast s3haot for approved CUBed date and,signatu's'�:-r. y, SANITARY o a LEVEL EFFLUENT FILTER 2" MIN. TEE i S �BUUKIHEAID (( $g,�n4�8.a°•: �,,, °a a o 3" MIN 12" MIN.L �'0 o.,�•°° broby „ °� va,,a a�a� CLEAN SAND, PEA GRAVEL OR AGGREGATE (3/4" - 1 1/2") a o m e •o `'.o:�m o ., o o• = o/ IF DESIGNED TO USE EXISTING SEPTIC TANKo-, PUMP OUT AND INSPECT _ EXISTING TANK. PROVIDE WRITTEN REPORT TO ENGINEER. SYSTEM COMPONENTS SHALL BE 1. MINIMUM TANK CAPACITY AS FOLLOWS: MAINTAINED. TANKS SHALL BE PUMPED SEPTIC REPLACEMENT DESIGN GRAVELLESS CHAMBER 1. PIPE JOINTS TO BE SEALED LIQUID TIGHT. - FOR 3 BEDROOMS OR LESS TANK SHALL BE 1,000 GALLONS, WITH OUT AND INSPECTED EVERY 2 YEARS PROJECT. - 27 S.F. SURFACE AREA. OR LESS FOR OPTIMAL PERFORMANCE; FOREST PARK BRtWOOD 2. SPEED LEVELING DEVICES SHALL BE USED ON ALL - 4 BEDROOMS SHALL HAVE A 1,250 GALLON TANK WITH 34 S.F. EFFLUENT FILTER (IF INSTALLED) SHALL LOT #18 2024 MODIFICATION OUTLET PIPES. SURFACE AREA BE CHECKED AND CLEANED - FOR EACH ADDITIONAL BEDROOM ADD 250 GALLONS & 7 S.F. REGULARLY. OTHERWISE PREMATURE 3. SEPTIC TANK TO D-BOX: 4" PVC OR SDR21, LIQUID SURFACE AREA. FAILURE COULD OCCUR . 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) TIGHT JOINTS, MIN. SLOPE 1/8" PER FOOT. - FOR HOT TUB/SPA AND/OR GARBAGE GRINDER ADD 250 GALLONS TO TANK SIZE FOR EACH. 4. THE SLOPE OF OUTLET PIPES BETWEEN THE DRAWING TITLE: DISTRIBUTION BOX AND DISTRIBUTION LATERALS 2. BUILDING TO SEPTIC TANK: 4" PVC SCH. 40 PIPE, LIQUID TIGHT JOINTS, QF NEtijr SHOULD BE SLOPED AT LEAST 1/32" PER FOOT MIN. SLOPE 1/4" PER FOOT. g Y RKENGINEERING, PLLC DETAILS AND CONSTRUCTED OF 4" PVC SCH. 40 OR SDR21 11 225 RUGGLES RD.,SARATOGA SPRINGS,NY WITH LIQUID TIGHT JOINTS. 3. SEPTIC TANK TO D-BOX OR PUMP TANK: 4" PVC SCH. 40 PIPE OR 1 518.581.3893 FILE NAME DETAILS SDR21, LIQUID TIGHT JOINTS, MIN. SLOPE 1/8" PER FOOT. 5. USE DOUBLE SIDED STICKING RUBBER BUTYL FOR ar SCALE AS NOTED DOSED SYSTEMS. 4. SEPTIC TANK TO CONSTRUCTED PER NYSDOH GUIDLINES. Z NO. SUBMITTAL / REVISION APP'D. DATE DATE APRIL 2024 ki NEW CONCRETE 14 tpo (j A ISSUED FOR REVIEW/APPROVAL RKR 2/2/22 DISTRIBUTION BOX CONCRETE SEPTIC TANK �d w� 1 RECORD DRAWING RKR 6/17/22 REVISION 2 Uj a a SCALE: NONE SCALE: NONE OF79 50 01`Z 2 of 0 0 A� $SSI ty 2 2024 FLOWS AT 550GPD RKR 4/19/24 SHEET C-100 2