1.3 1.3
WASTEWATER-SEWER\SetMOKeeffe—Replacement with Absorption Setback—In APA-8-5-2024
RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL
VARIANCE APPLICATION OF DANIEL AND MARY HELEN O'KEEFFE
RESOLUTION NO.: ,2024
INTRODUCED BY:
WHO MOVED ITS ADOPTION
SECONDED BY:
WHEREAS,the Queensbury Town Board serves as the Town's Local Board of Health and is
authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal
Ordinance, and
WHEREAS, the O'Keeffe Revocable Trust (Applicant), has applied to the Local Board of
Health for a variance from Chapter 136 to install a replacement wastewater system with fill material
for the absorption field to be placed/located 4' from the east property line in lieu of the required 10'
setback on property located at 102 Bay Parkway in the Town of Queensbury,
NOW, THEREFORE, BE IT
RESOLVED,that the Town of Queensbury Local Board of Health will hold a public hearing
on Monday, August 19'', 2024 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road,
Queensbury, to consider the O'Keeffe Revocable Trust's sewage disposal variance application
concerning property located at 102 Bay Parkway in the Town (Tax Map No.: 226.15-1-18) and at
that time all interested persons will be heard, and
BE IT FURTHER,
RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town
Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice
to neighbors located within 500 feet of the property as required by law.
Duly adopted this 5 h day of August, 2024,by the following vote:
AYES
NOES
ABSENT:
♦ I
/ - - ■re Im ■re WIN sre ■m am ■m •
I
LANDS NIP OF I
BRETT R. HEST
226.15-1-17 1 I
LAKE HATER SUPPLY I
1 I
: 1
1 I LANDS OF
:
1 I DANIEL & MARY HELEN O'KEEFFE
1 I 226.15-1-18
I LAKE WATER SUPPLY
1 � I
CQ
a I
1
m
■ I
� I
■
1 \
1 I \
■ I \
1 I \\�--------- 50' SHORELSETBACK
INE
■
■
1
■
PROPOSED 1,500 GALLON
DUAL COMPARTMENT PRECAST
CONCRETE SEPTIC TANK
1
1
i
1
EXISTING PUMP STATION TO BE
DECOMMISSIONED AND REMOVED
'
PROPOSED EFFLUENT SEWER
1
I
1
I
■
I
1
I
1
I
1
PROPOSED 1,000 GALLON PRECAST
CONCRETE PUMP STATION
I "LL I
: l EXISTING OUTDOOR SHOWER 30 SUM
1 TO BE PIPED INTO NEW
■ I BUILDING SEWER WITH TRAP • LL
■ — — — — — — — — — — — — �
1 I 100' SHORELINE SETBACK
I 6" TPL B I
- I
I LL
■ 1
1 PROPOSED 1-1/2` FORCEMAIN
TAPER TO EXISRNG�� ■ LL
■ I
1 I wy
■
■ I ■ ha
1 GRADE, MAX SLOPE 1:3
1: 3
1 I
I
1 I
1 I PROPOSED (3) ELJEN TRENCHES,
L 3 TRENCHES EACH 32' LONG
WITH 8 MODULES EACH, 24
1 1O' — _ _ K MODULES TOTAL, 96 LF TOTAL
PL SE�AC-' � \
\
S81•08'00-E ■■AK �■■�I■■�� \ IN,
LAKE GEORGE
• • E,Y/S17IVC
• SAKE
• = 'yOREC/NE
•
3
44
3 ,
AKE
E f /3
3
// • /
tj
:
y ;
/
` — f ij • • LANDS N/F OF
CHRISTIAN E. SANDER
KITCHEN SINK DRAIN • • 226.15-1-19
Arc Yn NCW wnr )Cr - LAKE HATER SUPPLY
Qyc 1. 73Y ' • tiyC•
6 B /
T- • z
ti
:'�
i
'TP-2 �•
VU
W��•
i
\ '.
/
i}�►
MIN
\
Pqp,
'e
•
,
•�•. /
WASTEWATER SYSTEM PLAN
:�
/
APPROX.
SCALE: 1 "=to'
sel�. '•sa SjllrG,
;
LOCATION OF
,
GRAPHIC
e49 '•�
:
NEIGHBORING /
ABS. FIELD
25 10
( IN FEET)
•,`
.
/
/
CONTRACTOR TD FlELD VERIFY LOCATIONS AND DISTANCES
SITE SOILS DATA
TP-2 - 0911512023 BY TOM HUTCHINS, P.E.
0-4"
- TOP SOIL
4-15"
- DARK LOAM
15-32"
- MEDIUM BROWN SILT LOAM FEW COBBLES
AND BOULDERS
32-57"
- DARK BROWN SILT- FIRM MOLTING
MOTTLING 0 32"
GROUNDWATER 0 51 "
BOUNDARY CONDITION ® 32"
PERCOLATION TEST -
STABILIZED PERCOLATION RATE= 6:20 MIN/INCH
DESIGN PERCOLATION RATE- 6-7 MINANCH
WASTEWATER SYSTEM DESIGN
5-BEDROOM RESIDENCE
WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX.
FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 550 GPD
SEPTIC TANK - NEW 1,500 GALLON DUAL COMPARTMENT
PRECAST CONCRETE SEPTIC TANK
PUMP STATION - NEW 1,000 GAL PRECAST CONCRETE
LEACH FIELD - 96 LF OF ELJEN TRENCHES
ELJEN ABSORPTION AREA REQ'O = (550 GPD)/(1.0 GPD/SF)
= 550 SF
MINIMUM LINEAR FEET REQ'D = (550 SF)/(6 SF/LF) = 92 LF
ELJEN LINEAR FEET PROVIDED = 96 LF
(UP TO A 6 MIN PERCOLATION RATE IN NEW SYSTEM FILL
MATERIAL PER NYSDOH APPENDIX 75-A)
ELJEN MODULES REQ'D = (92 LF)/(4 FT/MODULE) = 23 MODULES
ELJEN MODULES PROVIDED = (96 LF)/(4 FT/MODULE)
= 24 MODULES (3 MODULE ROWS WITH
8 MODULES/ROW)
APPLICATION RATE TO EXISTING SOIL: 1.0 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE (APPENDIX 75-A)
DOSING
DOSING TO DISTRIBUTION BOX VIA SIMPLEX PUMP STATION.
62 GAL CAPACITY IN DISTRIBUTION PIPING
VOLUME OF DOSE TO BE 40t GALLONS
POTABLE WATER SUPPLY IS LAKE WATER
-MAINTAIN 50' SETBACK TO SEPTIC TANK
-MAINTAIN 100' SETBACK TO MOUND (EDGE OF TAPERS)
MAP REFERENCE:
1. BASE MAP INFORMATION FROM "SURVEY OF LANDS FOR ASSEMBLY
POINT TRUST," IN THE TOWN OF QUEENSBURY, WARREN COUNTY,
NEW YORK. DATED OCTOBER 5, 2021. PREPARED BY CORNER
POST LAND SURVEYING, PLLC.
2. WESTERN NEIGHBOR INFORMATION FROM "A MAP OF A SURVEY
MADE FOR BRETT R. WEST" BY VAN DUSEN & SIEVES LAND
SURVEYORS, DATED MAY 31, 20OZ
3. EASTERN NEIGHBOR INFORMATION FROM "A MAP OF A SURVEY
MADE FOR CHRIS SANDER" BY VAN DUSEN & SIEVES LAND
SURVEYORS, DATED FEBRUARY 6, 2018.
-- `"`""-1. LULA 11UIV 1vIAIJ
WASTEWATER SYSTEM FILL MATERIAL NOTES
AFTER REMOVING ORGANICS AND TOPSOIL, PLACE WASTEWATER SYSTEM FILL OVER THE
ENTIRE AREA OF PROPOSED ABSORPTION FIELD AND TAPER AREA.
"WASTEWATER SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND, SANDY
LOAN OR SANDY LOAMY GRAVEL WITH IN -PLACE PERCOLATION RATE OF 3-5 MIN/INCH
AND NO ORGANICS OR OBJECTS OVER 3" IN SIZE. LESS THAN 109 BY WEIGHT SHALL
BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE IN
THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 159d OF THE MATERIAL BY WEIGHT
SHALL BE LARGER THAN A 1/2" SIEVE.
WASTEWATER SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE MINIMUM OF
3-FEET BETWEEN SEASONAL HIGH GROUNDWATER AND BOTTOM OF ABSORPTION FIELD.
ONLY SYSTEM FILL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION FIELD
AREA AND TAPER AREAS.
WASTEWATER SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS
WITH TRACKED EQUIPMENT PRIOR TO INSTALLATION OF ABSORPTION TRENCHES.
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF WASTEWATER SYSTEM FlLL
MATERIAL PRIOR TO TRANSPORTING TO S►TE
MATERIAL REQUIRED TO PROVIDE COVER OF SEPTIC TANK MAY BE NATIVE MATERIAL OR
OTHER MATERIAL WHICH IS NOT NECESSARILY "WASTEWATER SYSTEM FILL."
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S.
DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF
THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS
GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS.
PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES.
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF
AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN
INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE
INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER
BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES,
SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION
OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO
THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM
THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF
AROUND ABSORPTION FIELD.
SEPTIC TANK, PUMP STATION & ABSORPTION FIELD MUST BE INSPECTED BY LOCAL BUILDING
DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST
INSPECTIONS.
VARIANCE REQUEST SUMMARY
THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY SANITARY
1) INSTALL ABSORPTION FIELD FILL MATERIAL 4' FROM EAST PROPERTY LINE WHERE 10'
IS REQUIRED.
6' RELIEF REQUESTED
WASTEWATER SYSTEM SETBACK REQUIREMENTS
STREAM, LAKE,
PROPERTY LINE HOUSE WATERCOURSE, WELL
WETLAND
SEPTIC TANK 10' 10' 50' 50'
ABSORPTION FIELD 10' 20' 100' 100'
NPy
ighSafely,
e /York
■ Call Before You Dig
■ Walt The Required Time
■ Confirm Utility Response
■ Respect The Marks
■ Dig With Care
800.962.7962
www.dlgsafelymviyork.com
o N
v
C)
z
14
IN
ALTERATION OF THIS DOCUMENT EXCEPT BY
A LICENSED PROFESSIONAL ENGINEER IS A
VIOLATION OF NYS EDUCATION LAW.
Hutchins
Engineering
PLLC
169 HoWand Road
Queensbury, NY 12804
(518) 745-0307 Phone
(518) 745-0308 Fax
TAX MAP # 226.15-1-18
WASTEWATER
SYSTEM PLAN
prepared for:
O'Keeffe Family
Revocable Trust
102 Bay Parkway
Town of Queensbury,
County of Warren,
State of New York
Drawn: WOCIAVANIMI Chocked: OTH
Scale: NOTED I Date: 08/02/2029
292201-01 -S 1
4" MIN. TOPSOIL,
ESTABLISH TURF
4" SCH 40 PVC
PERFORATED PIPE
GEO-TEXTILE COVER
WASHED CONCRETE
SAND CONFORMING TO
NYSDOT SPECIFICATION
703-07
IN -DRAIN UNIT
HOLES ® 5&7 O'CLOCK
2' MIN &
BETWEEN L-I
APPROXIMATE
EXISTING GRADE
4" PVC SDF
INLET
MIN. SLOPE
1/4" PER FOOT
WATERTIGHT SLEEVE
AND SEAL (TYP)
4" PVC TEE & TAIL
PIECE INLET BAFFLE
NEW 1,500 GAL
DUAL COMPARTMENT
PRECAST CONCRETE
SEPTIC TANK
12" OF 3/4-1-1/2"-
CRUSHED STONE
PRECAST CONCRETE
ANTI -FLOATATION
BASE EXTENSION
BY MANUFACTURER
DETAILED EVEN MODULE SECTION
NTS
2"
POLYETHYLENE EXTENSION
—TO GRADE WITH TAMPER —�
RESISTANT ACCESS COVER
APPROXIMATE FINISHED GRADE
12" MIN.
COVER
6" MIN. N
LIQ�ID LEVEL
16" 47H x18"W SLOT,
(2) 4" ELBOWS
OR 6" ELBOW
zQ
:XZ
60-75% OF
TANK VOLUME
MINIMUM 2X WIDTH 1
113
1
DEPTH
18"
OF OUTLET
MIN.
INVERT
25-40% OF
TANK VOLUME
g"
fN
n1 I I.'1 V I—, — _V VI — I L J .-
ELGEN ABSORPTION BED SECTION
1,000 GAL PRECAST
CONCRETE PUMP STATION
4" PVC TEE & TAIL
PIECE OUTLET BAFFLE
BALL VALVE, ONE PER PUMP,
INSTALL VALVES AND UNIONS
SUCH THAT EITHER PUMP CAN
E4. ,BE ISOLATED AND REMOVED
WITHOUT REQUIRING PIT ENTRY v a
4" PVC SDR-35
OUTLET EFFLUENT SEWER
MIN. SLOPE no- fi4
118" PER FOOT
FLOAT SWITCHES - INSTALL INSIDE
PUMP PIT IN LOCATION
ACCESSIBLE WITHOUT PIT ENTRY
ALARM
4"
s e . a e °
d ° G
ada a
. °. < .. A ' < .d.
<°
SEPTIC TANK DETAIL
NTS
PUMP ON
PUMP OFF
VOLUME OF DOSE
PER NOTE
16 MIN. I :
BALL CHECK VALVE)
SIMPLEX (1) EFFLUENT PUMP —
12" OF 314-1-112"
CRUSHED STONE
NTS
30" POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
CHAIN ON PUMP TO TOP
OF TANK TO ALLOW FOR
FUTURE PUMP REMOVAL
WITHOUT ENTERING TANK
PRECAST CONCRETE
ANTI -FLOATATION
BASE EXTENSION
BY MANUFACTURER
PUMP STATION DETAIL
NTS
2" TEE JOINS TWO PUMP
DISCHARGES INTO
ONE FORCEMAIN
MATERIAL WITH NATIVE SOILS TO DEPTH OF 1.5'
EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY).
SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE.
ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL
INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION.
12"t COVER
CONNECT TO 2" PVC J
PRESSURE DISTRIBUTION
MANIFOLD
2" PVC SDR-26
OR SCH-40
FORCEMAIN PROVIDE POSITIVE
DRAINBACK TO
PUMP STATION
2" SCH-40 PVC INSIDE
WET WELL THROUGH WALL
GATE VALVE
REDUCING TEE POINTED DOWNWARD
° a WITH 1" BALL VALVE THROTTLED TO
ALLOW TRICKLE DRAIN BACK INTO
_f
WETWELL
�
UNION (2)- LOCATE SUCH THAT UNION
CAN BE DISCONNECTED AND EACH
PUMP REMOVED WITHOUT TANK ENTRY
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW
YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST
CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR
EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR
GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE,
CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A
STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA
HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW
THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING.
PUMP STATION NOTES
SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL
WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, ALTERNATING,
DEMAND DOSE CONTROL PANEL INSIDE BUILDING IN ACCESSIBLE
LOCATION.
INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN
HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
NATIONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS.
PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO PROVIDE A
40 GALLON DOSE.
EFFLUENT PUMPS TO BE GOULDS 3885 MODEL WE03M, 230V,
SINGLE PHASE, 30 GPM PUMP AT 20 FT TDH.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP.
Dig ® Safely.
ew/York
■ Call Before You Dig
■ Walt The Required Time
■ Confirm Utility Response
■ Respect The Marks
■ Dig With Care
800-962.7962
,MwwAlgsafelynewyoik.com
o
N
4-1
p
U
Z
U
�
O_
W
p
�
N
W
o
z
ALTERATION OF THIS DOCUMENT EXCEPT BY
A LICENSED PROFESSIONAL ENGINEER IS A
VIOLATION OF NYS EDUCATION LAW.
Hutchins
Engineering
PLLC
169 Haviland Road
Queensbury, NY 12804
(518) 745-0307 Phone
(518) 745-0308 Fax
TAX MAP # 226.15-1-18
WASTEWATER
SYSTEM
DETAILS
prepared for:
O'Keeffe Family
Revocable Trust
102 Bay Parkway
Town of Queensbury,
County of Warren,
State of New York
Drawn: WOC/AVAMK
B Checked. aTH
Scale: NOTED
Data: 0S/0*=3
292201-01 -S2