2024-0416 ilEC F Fry, 3) Office Use Only AUG 0 7 122 Permit#: 1,1�RI OF LEA 3l i_iF�1' Permit Fee: Sz c� 742 Bay Road,Queensbury,'NY 1280 o0Ii_®ING 'C`�-k `' Invoice# P:518-761-8256 www.queensbuFmet— Flood Zone? ® Reviewed By. SOLAR PANEL PERMIT APPLICATION SITE INFORMATION: Project Location: 14 Bennett Rd Queensbury NY 12804 Tax Map ID#: 295.14-1-25 Subdivision Name: PROJECT INFORMATION: Residential: Commercial Other: Single Family Multi-Family Are the solar panels? V Purchased Leased Estimated cost of construction: $ 14,040.00 Total System Capacity Rating (sum of all panels): Solar PV System: 10.8 kW DC Select System Configuration: Supply side connection with micro inverters Supply side connection with DC optimizers Supply side connection with string inverter Load side connection with DC optimizers Load side connection with micro inverters Load side connection with string inverter Solar Panel Application Revised January 2021 DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. A third-party electrical inspection will be completed at which time the Town of Queensbury's Building and Codes Enforcement department will be contacted to complete an inspection of the final installation of the solar panels. Please sign below to affirm that all answers are correct and that you have met all of the conditions and requirements to submit a unified solar permit. I have read and agree to the above: /e4eAtW_md 8/5/2024 Homeowner's Signature Date C/1 S 8/3/2024 Solar Co. Representative Signature Date Solar Panel Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Property Owner(s): Name(s): Robert McLeod Mailing Address, C/S/Z: 14 Bennett Rd Queensbury, NY 12804 Cell Phone:_(518 )796-9929 Land Line:_( ) _ Email: bob.jmc1976@gmail.com • Solar Contractor: Workers' Comp documentation must be submitted with this application Business Name: Plug PV LLC Contact Name: 630 7th Ave Troy, NY 12182 Mailing Address, C/S/Z: "" Cell Phone:_(838 ) 839-1500 Land Line:_(518 )948-5316 Email: permits@plugpv.com/cbreen@plugpv.com • Electrical Contractor: Workers' Comp documentation must be submitted with this application Business Name: Plug PV LLC Contact Name: Steve Weigel Mailing Address, C/S/Z: 630 7th Ave Troy, NY 12182 Cell Phone:_( ) Land Line:_( ) Email: permits@plugpv.com/cbreen@plugpv.com Contact Person for Compliance in regards to this project: Chelsea Breen Cell Phone: (838 )839-1500 Land Line: ( ) Email: permits@plugpv.com/cbreen@plugpv.com Solar Panel Application Revised January 2021 (518)948-5316 HELLOOPLUGPV.COM PLUG^\I HTIPS://WWWPLUGPV.COM t'" 630 7TH AVENUE,TROY,NY 12182 LETTER OF AUTHORIZATION FOR ZONING AND PERMIT APPLICATION To Whom It May Concern: t, QD �cr NAG Lena as owner(s)of the property located at y l thee, - i d f 0JeeJ-J 1� N1 Hereby designate PlugPV,LLC.as my contractor and registered agent for the purposes of the applying for Permits and Zoning Board representation regarding my solar installation project. Print a)-el/ _ Wkz.s Sign Date 0 DU �=s 1) 1, AUG 0 7 2024 TOWN OF OUEENSBURY BUILDING&CODES 1221 CamScarmer BEE Hi-MOFI AUG 0 70 F.71 TOWN OF QUEENSbUi ' BUILDING&CODES LR5-54HABB 39O '415 M ■ Suitable for distributed projects • Advanced module technology delivers superior module efficiency •M10 Gallium-doped Wafer •Integrated Segmented Ribbons •9-busbar Half-cut Cell • Globally validated bifacial energy yield • High module quality ensures long-term reliability 25-year Warranty for y Materials andd Processing 30 30-year Warranty for Extra Linear Power Output Complete System and -- Product Certifications = IEC 61215,IEC 61730,UL 61730 1509001:2015:ISO Quality Management System IS014001:2015:ISO Environment Management System IS045001:2018:Occupational Health and Safety IEC62941:Guideline for module design qualification and type approval ■ LONGI cat. C E , Hi-MO © LR5-54HABB 390-415M 21.3% 0-3% <2% 0.45% HALF-CELL MAX MODULE POWER FIRST YEAR YEAR 2-30 EFFICIENCY TOLERANCE POWER DEGRADATION POWER DEGRADATION Lower operating temperature Additional Value , . I 30-Year Power Warranty 100% 98% .+275% � fetr � 912% • f +4.00% •-' 87.7% +4.95% I, 84.5% - 1+6.50% ( 80.7% Units:mm 9 1722 1400 ___- 1150 - 1 5 10 15 20 25 30 - --- I Mechanical Parameters f=___ r=* - _ 1`,. Cell Orientation 108(6x18) =�i= f f -) `�� r Junction Box IP68,three diodes =_(__{a=i=t==_,;_uA-n=_�_-__-(_ 4mm2,±1200mm -J �__ -=1=- _=-�=� i Output =p,- �_' _ _-' _=_fi._ p length can be customized =_'- -____-�==1 =!=1= _,-,r. Glass Dual glass,2.0+1.6mm heat strengthened glass -__ k =_I_)-- a=';= Frame Anodized aluminum allo frame --..,--2, ,;= _=,,== � =�=.I -_ =I_-f-. Weight 22.5kg Tolerance: 9 Length:±2mm it-Toles II Dimension 1722x1134x30mm Width:±2mm Packaging 36pc5perpallet/216pcsper20'GP/936pcsor792pcs(OnlyforUSA)per40'HC c " Electrical Characteristics STC:AM1.5 1000W/m2 25°C NOCT:AM1.5 800W/m2 20°C lm/s Test uncertainty for Pmu33% Module Type LR5-54HABB-390M LR5-54HABB-395M LR5-54HABB-400M LR5-54HABB-405M LR5-54HABB-410M LR5-54HABB-415M Testing Condition SiC NOCT STC NOCi STC NOCT SiC NOCi SiC NOCi SiC NOCi Maximum Power(Pm ax/W) 390 2915 395 2952 400 299.0 405 302.7 410 306.5 415 3102 Open Circuit Voltage(Voc/V) 36.58 34.39 36.81 34.61 37.05 34.84 3729 35.06 37.53 35.29 37.77 3551 Short Circuit Current(Isc/A) 13.57 10.95 13.65 11.01 13.72 11.07 13.79 11.13 13.87 11.19 13.94 11.25 Voltage at Maximum Power(Vmp/V) 30.47 28.43 30.70 28.64 30.94 28.86 3L18 29.09 31.42 29.31 31.66 29.54 Current at Maximum Power(Imp/A) 12.80 1026 12.87 10.31 12.93 10.36 12.99 10.41 13.05 10.45 13.11 10.50 Module Efficiency(%) 20.0 20.2 205 20.7 21.0 21.3 Electrical characteristics with different rear side power gain(reference to 400W front) Pmax/W Voc/V Isc/A Vmp/V Imp/A Pmax gain 420 37.05 14.41 30.94 13.58 5% 440 37.05 15.09 30.94 14.22 10% 460 37.15 15.78 31.04 14.87 15% 480 37.15 16.46 31.04 1552 20% 500 37.15 17.15 31.04 16.16 25% Operating Parameters Mechanical Loading Operational Temperature -40°C-+85°C Front Side Maximum Static Loading 5400Pa Power Output Tolerance 0-3% Rear Side Maximum Static Loading 2400Pa Voc and Isc Tolerance ±3% Hailstone Test 25mm Hailstone at the speed of 23m/s Maximum System Voltage DC1500V(IEC/UL) Maximum Series Fuse Rating 30A Nominal Operating Cell Temperature 45±2°C Protection Class Class II Temperature Ratings(STC) Bifaciality 70±5% Temperature Coefficient of 1st +0.050%/°C UL Similar type 38° Temperature Coefficient of Voc -0.265%/°C Fire Rating IECClassC Temperature Coefficient of Pmax -0.340%/°C 'Reference Standard:UL61730 Second Edition,Dated October 28,2022 Specifications Included in this datasheet are • No.8369 Shangyuan Road,Xi'an Economic And subject to change without notice.LONGI �14G' Technological Development Zone,Xi'an,Shaanxi,China. reserves the right offinal interpretation. Web:www.longi.com (20230115V17)Only for North America ENPHASE. DATA SHEET illI'1 I L I IN I L I 'r I I •1 r I I 1 I ir I I '. -_0'H E - GFHASE - .I ' ENPHASE ._.=y,•® 10� r -' ..•. - IQ8A -� 1 ENPHASE ''-A ' ' - • . I I 1 IQ8. I ' i - I nEgnd,.:I - . - - e rr4 _ _ f•1...•'„ia t I- ' • ';L�, ._a• I :_ ,d'- n 1 .. - �• ;lilt — A7r,....SN. L. : I • u IQ8 Series Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the • Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times • Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling - Enphase ''•,............--- • • {i p High productivity and reliability e i !i iI ,J i . Produce power even when the li; year limited grid is down i; i warranty e; II — - • More than one million cumulative Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, • Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules 411 (111) Microgrid-forming CERTIFIED • Complies with the latest SAFETY advanced grid support pport Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as • Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when Installed connectors. according to manufacturer's instructions. • Configurable to support a wide range of grid profiles Ct 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,108 microinverters, • Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SE-DS-0001-OI-EN-US-2021 10-19 • IQ8 Series Microinverters INPUT DATA IOC1 108-60-2-US 108PLUS-72-2-US I08M-72-2-US 108A-72-2-US 108H-240-72-2-US 108H-208-72-2-US' Commonly used module pairings' W 235-350 1 235-440 260-460 I 295-500 320-540+ 295-500+ Module compatibility 60-ce11/120 half-cell! 60-ce1l/120 half-cell and 72-ce11/144 half-cell MPPf voltage range V I 27-37 i - 29-45 I 33-45 36-45 38-45 38-45 Operating range V 25-48 1 25-58 Min/max start voltage V ; 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Ise] A ; 15 Overvoltage class DC port II DC port backfeed current • mA { 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATAIACI 108-60-2-US 108PLUS-72-2-US 108M-72-2-US 108A-72-2-US 108H-240-72-2-US 108H-208-72-2-US y384 366 Peak output power VA • 245 300 j 330 � 366 Max continuous output power VA 240 290 i 325 349 380 . i 360 Nominal(L-L)voltage/range' V i 240/211-284 ; 208/183-250 Max continuous output current A 1 1A 121 ' L35 1.45 j 1.58 1.73 i Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit° 16 j 13 11 ; 11 10 9 Total harmonic distortion <5% Overvoltage class AC port j III AC port backfeed current mA 30 Power factor setting -1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % { 97.5 i 976 I 97.6 I 97.6 i 97.6 i 97.4 CEC weighted efficiency % 97 97 97 975 i 97 I 97 • Night-time power consumption mW • 60 MECHANICAL DATA Ambient temperature range ( -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) I 212 mm(8.31 x 175 mm(6.9")x 302 mm(L2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at m I <60 dBA Pollution degree PD3 Enclosure Class II double-Insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating j NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product Is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's Instructions. (1)The 1O8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https✓/Unk.enphase.com/module-compatlbllity(3)Maximum continuous Input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal If required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microlnvertere per branch in your area. IO8SE-DS-0001-01-EN-US-2021-10-19 ENPHASE. OATASHEET • • 9ENPHASE • 1. • • X-IQ=AM1-240-5. X-IQ-AM1-240-5C • • IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and Smart - streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, • Includes IQ Gateway for pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. • Includes Enphase Mobile Connect (CELLMODEM-M1-06-SP-05),only The IQ Combiner 5/5C,along with IQ Series Microinverters,IQ System Controller 3/3G,and with IQ Combiner 5C IQ Battery 5P provides you with a complete grid-agnostic Enphase Energy System. • Supports flexible networking:Wi-Fi, •Ethernet,or cellular 1 p b. • Provides production metering (revenue grade)and consumption monitoring• o Easy to Install IQ Series Microinverters IQ System Controller 3/3G • Mounts to one stud with centered The high-powered smart grid-ready IQ Series Provides microgrid interconnection brackets Microinverters(106,IQ7,and IQ8 Series) device(MID)functionality by • Supports bottom,back,and side dramatically simplify the installation process automatically detecting grid failures and conduit entry seamlessly transitioning the home energy system from grid power to backup power • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers J (not included) T • 80 A total PV branch circuits • • Bluetooth based WI-Fi provisioning for easy Wi-Flsetup - 1. Reliable • Durable NRTL-certified NEMA type 3R enclosure IQ Battery 5P IQ Load Controller • 5-year Ilmited warranty Fully integrated AC battery system.Includes six Helps prioritize essential appliances field-replaceable IQ8D-BAT Microinverters during a grid outage to optimize • Two years labor reimbursement energy consumption and prolong program coverage included for both battery life the IQ Combiner SKUs • UL1741 listed Enphase L LISTED 5-year limited warranty ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at https://enphase.corn/trademark-usaqe-ouideiines are trademarks of Enphase Energy,Inc.In the US and other countries. Data subject to change. IQC-5-5C-DSH-00007-2.0-EN-US-2023-09-27 IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 with IQ Gateway printed circuit board for Integrated revenue grade PV production IQ Combiner 5(X-I0-AM1-240-5) metering(ANSIC12.20±0.5%),consumption monitoring(t 2.5%)and IQ Battery monitoring 025%). Includes a silver solar shield to deflect heat IQ Combiner 5C with IQ Gateway printed circuit board for Integrated revenue grade PV production IQCombinerSCOC-IQ-AM1-240 5C) metering(ANSI C12.2O±0.5%),consumption monitoring(t2.5%)and lQ Battery monitoring(t25%). Includes Enphase Mobile Connect cellular modem(CELLMODEM-MI-08-SP-0S),Includes a silver solar shield to deflect heat WHAT'S IN THE BOX IQ Gateway printed circuit board . 10 Gateway Is the platform for total energy management for comprehensive,remote maintenance and management of the Enphase IQ System Busbar 125A busbar with support for 1 x IQ Gateway breaker and 4 x 20A breaker for Installing IQ Series Microlnverters and 10 Battery 5P IQ Gateway breaker r Circuit breaker,2-pole,1O A/15 A Production CT Prewired revenue-grade solid core CT,accurate up to 0.5% Consumption CT Two consumption metering clamp CTs,shipped with the box,accurate up to 25% 10 Battery CT One battery metering clamp CT,shipped with the box,accurate up to 2.5% CTRL board Control board for wired communication with 10 System Controller 3/3G and the 1Q Battery 5P Enphase Mobile Connect(only with IQ Combiner 5C) ; 4G-basedLTE-M1cellularmodem(CELLMODEM-M1-06-SP-O5)witha5-yearT-Mobile data plan Accessories kit ! Spare control headers for CTRL board ACCESSORIES AND REPLACEMENT PARTS INOT INCLUDED,ORDER SEPARATELY) CELLMODEM-M1-08-SP-05 40-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CELLMODEM-M1-06-AT-05 40-based LTE-M1 cellular modem with a 5-year AT&T data plan Circuit breakers(off-the-shelf) a Supports Eaton BR21O,BR215,BR220,BR23O,BR24O,BR25O,and BR260 circuit breakers Supports Eaton BR220B,BR230B,and BR240B circuit breakers compatible with hold-down kit Circuit breakers(provided by Enphase) BRIO-10A-2-240V,BRK-15A-2-240V,BRK-20A-2P-240V,BRK-15A-2P-240V-B,and BRK-20A-2P- 240V-B(More details in"Accessories"section) XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 j 1Q Gateway replacement printed circuit board(PCB)for Combiner 5/5C X-IQ-NA-HD-125A : Hold-down kit compatible with Eaton BR-B series circuit breakers(with screws) ELECTRICAL SPECIFICATIONS Rating 80 A System voltage 120/240 VAC,60 Hz Busbar rating 125 A Fault curent rating 10 kAIC Maximum continuous current rating(Input from PV/storage) 64 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series distributed generation(DG)breakers only(not Included) Maximum total branch circuit breaker rating(input) 80 A of distributed generation/135 Awith IQ Gateway breaker included IQ Gateway breaker 10 A or 15 A rating GE/Slemens/Eaton included Production metering CT 200 A solid core pre-Installed and wired to IQ Gateway Consumption monitoring CT(CT-20O-CLAMP) , A pair of 200 A clamp-style current transformers Is Included with the box IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the box 'A plug-end-play Industrial-grade cell modem for systems up to 60 mkxdnverters.(Avssabie in the US,Canada,Madco,Puerto Rico,and the US Virgin Islands,where there Is adequate cellular service In the installation area.) IQC-5-5C-DSH-00007-20-EN-US-2023-09-27 Tech Brief JAIL IRON RIDGE XR Rail Family Solar Is Not Always Sunny ` - , Over their lifetime, solar panels experience countless 0,-_ extreme weather events. Not just the worst storms in years, - ':' 41 - ----but the worst storms in 40 years. High winds capable of - ripping panels from a roof, and snowfalls weighing i enough to buckle a panel frame. f/� v p, 4 i XR Rails are the structural backbone preventiow ng -% \' �,.`� � �, P 9 �® these results.They resist uplift, protect : .--....44‘ against buckling and safely and efficiently 4*, tot®; transfer loads into the buildingstructure. — ` - ''^�:�.. Their superior spanning capability ,{ `+ °` ®® requires fewer roof attachments, -( _ ,__. � _. _ --,... -----.. .14,;•_ reducing the number of roof ' _ • - ®® penetrations and the amount __- �t -� �+ ��'� ' ` `/( _ -...mot �.� '` �y 4 of installation time. • ',- - ,.n:W - --41 - I tom ,, 0 r _--_-_ .:_r-----1: __- .. : ;. r `'I' - Force-Stabilizing Curve Sloped roofs generate both vertical and lateral -- forces on mounting rails which can cause them '' to bend and twist.The curved shape of XR Rails Is specially designed to Increase strength in both ;'.Y directions while resisting the twisting.This unique feature ensures greater security during extreme ¢ weather and a longer system lifetime. H Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series ;i compatible with a range of tilt leg aluminum alloy,then protected with an FlashFoot and options for flat anodized finish.Anodizing prevents surface n other pitched roof n roof mounting and structural corrosion,while also providing P ; attachments. applications. a more attractive appearance. ��. • Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads,while minimizing material costs. Depending on your location,there is an XR Rail to match. 1---- ----- ------mil {— , _,------16k r -- li -- _ ._ — , _ `':` . XR10 XR100 XR1000 XR10 Is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.*Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow(PSF) Wind(MPH) 4' 5'4" 6' 10' 12' 90 a i 120 None _ I 140 XR10 _ _--- -- F100 2211000 i 160 i " -' 90 f y s 120 a ,,;: 140 5 160 ;� a y Xp 30 160 i - 90 >~ 40 1 th,...--..L-4,........U.a. 160 � _r 80 160 , � ., � 120 160 i .:_ ,- 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. igi 2020'tronRitlge,Inc.All rights reserved Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 120 �illiN Cut Sheet /P IRON RIDGE QuickMount® Halo UltraGrip V RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY OSHOWN FOR REFERENCE 4r y /7i Release Liner ' ,---1 --1 shown for reference -' 4 ; ems: o O // ITEM NO DESCRIPTION CITY IN KIT 1 QM Halo UltraGrip(MiII or Black) 1 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black a c 2022 lronRldge,Inc.All rights reserved.%isd www.U-per com for patent Information. OM-HUG-01.81 or QM-HUG-01-MI Cut Sheet Rev 1.0 Cut Sheet 1. Halo UltraGrip .38 1 it 3.35 1.... I I I I1 11 3.83 --H .40 1-..— 4.,,, '-► 1 (I . o 1 -ry 01-1 — 1.56 1 IIIiiii�_—Iiil I l . _ I 'UPI .'�'^'�-. WI - ' .i, . e 1 � 1 /,_ 0 0 .34 j \ / } I ( I I 111 3.00 Property Value Material 300 Series Aluminium Finish Mill or Black .2022 IrenRidge,Inc.All rights reserved.Visit www t-patents.00m for patent Information. QM-HUG-01-B1 or QM-HUG-01-MI Cut Sheet Rev 1.0 IP;ZS June 19,2024 ®v PlugPV LLC 11 r``; 630 7th Avenue 1 Troy,NY,12182 AUG ,, 4 7 Iii Subject:Structural Certification for Installation of Solar Panels s L;, Job Number:24-03035 TO \j OF QUEr t11��: Client:McLeod,Robert-008625-P24-1190619R2J B''ILD!NG& r•, -' Y Address:14 Bennett Road,Queensbury,NY 12804 "` - Attn.:To Whom It May Concern The scope of work is limited to performing a structural evaluation of loading at the address above.After review,the EOR certifies that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and criteria shown below: Design Criteria: • Applicable Codes=2020 Residential Code of NYS,ASCE 7-16,and NDS-18 • Ground Snow Load=50 psf;Roof Snow Load=34.7 psf ARRAY 1-2 • Basic Wind Speed=110 mph Exposure Category C • Existing Roof Dead Load:ARRAY 1-2=10 psf • Existing Roof Live Load:19.2 psf The existing structure is adequate to support the PV alteration per 2020 EBCNYS§503.3&503.4. PV System Assembly The PV module assembly including all structural supporting components shall be installed in accordance with the manufacturers specifications and meet or exceed all requirements set forth by the referenced codes above. Installation Requirements The PV system shall be mounted flush to the existing roof surface.The contractor shall notify the EOR of any signs of damage to the roof framing prior to commencing the installation.The EOR shall then determine if the existing roof is adequate to support the applied loads.The electrical engineering and system waterproofing shall be addressed by others. If you have any questions on the above,do not hesitate to call. ��OF NE0; ��. t K. Zq O,>~ Sincerely, _zip- 1 r-~--�t cyF,�' C' it A r 1- '.</ "I,'*, i*�. n �T 1I1 W (�m.`aa W Paul Zac - / XP�91365z AROFESSIONPN.. 06/19/2024 < ( \ , . PHOTOVOLTAIC SYSTEM � r ..,-.7,,,, (I�/-f� �� ; _ ; , 1��°° > Lif SYSTEM SIZE: ,y � �': t r ;, :'' '•' i if j 1 ___I /'� !rl �i NAMEPLATE: 10.8 KW DC/7.83 KW AC t. Y"j ' - - '� � ; (hi f / 1 i 1 ii 1 V 2i i Li E PV MODULES:27 LONGI SOLAR LR5-54HABB�OOM 400 SOLAR MODULES i'", _� {• - r ", ; •r`'r` } �' f 4�. ti! X !`Yr a ( ) ( ,M ii 7.- ---, MICROINVERTER:(27)ENPHASE 108PLUS-72-2-US MICROINVERTERS '"`o( �' v r= � 4 7 Ji M� ,. J- z,+ :-.9 ( TOBcEnettRd f16 ' r_ - - Wie.�nslfOry N4� P T S: (1)125A ENPHASE IQ COMBINER PANEL 5/5C `i;l`a; r,1 r 1 l =`)r L ? r t�`� CI , a�,c i I, B2aT,unlledstates i1 I' ` ~` rm ACCOMONENO _ { (1)60A FUSED AC DISCONNECT 't ' ( ;�tm '"L' �` �� 1,.., ti `� AUG 0 7 2024 J j ' p m r {,� ,a),.::. ti `.� fH'_, TOWN OF d..UEENSBURY f a v >> TYPE OF INTERCONNECTION: LINE SIDE TAP IN THE MSP (Ict , y� • 1 _ •- r:' [ILEDiNG 8,CODES i a. 2 v a SCOPE OF WORK: =ti .. + - ,� r q ®, r._„ m„�,.®....-... m_. I 1H c°D�I INSTALLATION OF A CODE COMPLIANT,UTILITY INTERACTIVE . 1, ' cl. 17 2 •J •'v., p:... �- I i ; j I j }- PHOTOVOLTAIC ELECTRIC SYSTEM. �' - s, 'i fi s � � ^� ,T� r} _ 1 I0 m �j {'�, 2/ f I 0 0 z AERIAL VIEW 43.339520,-73.721240 VICINITY MAP CO 2017 NATIONAL ELECTRICAL CODE I�� QPY _ 2020 FIRE CODE OF NYS i - ROBERT MCLEOD: 14 BENNETT RD, QUEENSBURY, NY 12804, Vv�� OF QU��RASB� ` 2020 RESIDENTIAL CODE OF NYS R n\ ELECTRICAL NOTES: BUILDING a CODES D F. -°\ • oo M N 2020 BUILDING CODE OF NYS GENERAL NOTES: R W O ti W 1. ALL EQUIPMENT IS LISTED FOR USE. Reviewed 6J " 1. DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF RACEWAYS 2 MAXIMUM VOLTAGE DOES NOT EXCEED 1300VDC. (� SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR 3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION r p APPLICABLE CODE PER LOCAL AUTHORITY HAVING STANDARDIZED. SHALL BE NEW AND LISTEDBYA RECOGNIZED E1ECTRICALTE r a e° U U O 2 ALL EQUATIONS ACCOUNT FOR WORST CASE cONDRIONS. LABORATORY. JURISDICTION 3. IFA DISCREPANCY MQUANtm OR SIZE OF CONDUIT,WIRE,EQUIPMENT DET/ICEB, 4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY OVER-CURRENT PROTECTION.GROUNDING SYSTEMS,ETC-(ALL EQUIPMENT AND DE-ENERGIZE ITS OUIPUTTO THE CONNECTED ELECTRICAL PRODUCTION AND p < MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND DISTRIBUTION NET WORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE NETWORK VOLTAGE HAS BEEN RESTORED. (�y COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND 5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. ' 1- Q SAFETY OF THE OPERABLE SYSTEM. 6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT 4. ALL OUTDOOR EQUIPMENT SHALL BE MIN.NEMA 3R RATED. CALCULATED AT THAT COMPONENT. F -1 CO 6. METAL CONDUITAND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT 7- ALL MODULES AND ANY RELATED ROOF MOUNTED METALUC EQUIPMENT SHALL ......-I D APPLICABLE CODES CIRCUITS ARE RUN INSIDE A BUILDING. BE PROPERLY GROUNDED. 6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6• 8. DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. ABOVE FLUSH VENTS. 9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE ¢ Q 7. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. 5 F Fi GIVEN BY UTILITY COMPANIES. 10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL Z ...1 PV7 COVER PAGE 8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. BOXES OR JUNCTION BOXE&COMBINER BOXES PER APPROPRIATE a- }} 9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY JURISDICTIONAL REQUIREMENTS. O o NEC AND THE LOCAL AHJ.THEAHJ MAY HAVE SPECIAL LABEL REQUIREMENTS 11. FOR ANY UNGROUNDED PV SYSTEM,A LABEL READING:-WARNING-ELECTRICAL V c,J PV2 SITE PLAN BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY ENCOMPASS LANGUAGE SHOCK HAZARD.THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE KO INCLUDING.BUT NOT LIMITED TO,THAT FOUND IN NEC ARTICLES 690.E(C),690.14 UNGROUNDED AND MAY BE ENERGTZED.SHALL BE PLACED AT EACH JUNCTION(CK2),690.17,690.53.690.35(F),690.54,690.64(B)(7)and 705.10. BOX,COMBINER BOX DISCONNECT AND DEVICE WHERE ENERGIZED, ( DATE 1 PV3 MOUNTING PLAN 10. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEO UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. 06/18/2024' REFERENCES. 12. INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION STRUCTURAL NOTES: DEVICE PV4 STRUCTURAL DETAILS 13. ALL METALUC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND 1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE.BUT SHALL BE ELECTRICALLY CONTINUOUS. DESIGNED BY: 1 14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CECINEC. ACCURATELY SPACED. 2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD 15. BAGCIRC IT ORAR BRTESTAER(S)SAYIF BE INSTALLEDRT THEOPPOSITE END OF ` OS nA , PV5 MOUNTING DETAILSAMONGST RAFTERS THEL IRE,V OR FURTHEST AND EQUIPMENT MAIN BREAKER.SIZEDIER t V' 3. DO NOT SPLICE RAILS IN MIDDLE 60%OF SPAN BETWEEN TWO MOUNTS. 16. ALL WIRE,VOLTAGES,AMPERAGES AND EQUIPMENT IS ACCORDING TO PV6-6.1 ELECTRICAL DIAGRAMS TEMPERATURE COPPER RE CU)CONDUCTTING RSLO SHALL / 17. ONLY COPPER(CU)CONDUCTORS SWILL BE USED.CONDUCTORS SHALL BE C STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. -(G of NEW y TOWN OF QUEENSBURY 18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. !1 K 2q O PV7 MARKING$LABELS 19. ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS. J� Cy BUILDING DEPARTMENT 20. ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE • NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDMDUAL PIECES OF RAIL. fZ I G5�%f. FAT,a*� `ATTACHMENTS Based on eur limited examination,compliances.__1:1 ` i n I slI j<l ct, 04 r with our comments shall not be construed as 1 I a indicating the plans and specifications are in F, '.�, - MANUFACTURER'S SPECIFICATIONS full compliance with the building Codes of ` ,,p 1/3643e2-0 • INDEX `G ( StRAL NOTES 6/19/024 J PV1 / ARRAY 1 X ARRAY 2 \ _—- TILT:22° TILT:22° 0_ W PROPERTY LINE AZIMUTH:98° AZIMUTH:278° 1 I — PROPERTY LINE D- al m �W s o A,a 1 ? / iI f a ARRAY SPECIFICATIONS z W W a co o g O a0 '°`6' a 8 UTILITY METER I' I- Pe' 9E /WOW ni� 1 ♦� I I d AC DISCONNECT FUSED ~ Fri t} Q COMBINER PANEL U) GLj n MAIN SERVICE PANEL 0 Z i nEj i 18"VENTILATION SETBACK m 1 Cli1 3'WIDE FIRE ACCESS PATHWAY I �+4" ElplISEDI O I \ 3'x3'GROUND LADDER ACCESS POINT I I Gp M N Q 37,-4. \. Liiiiila ab "ill 2 O 2 z LEGEND o i . z DRIVE WAY is .o 0/1' O .U.1 ~a c� J I zJN W 1 I 1 O Q. (p zI I `° , DATE CC I I 06/18/2024 W N Q. 1 v f DESIGNED BY: \ � OSMJ a , I �OF NE i !IJV K ZgCy�O PROPER�rLINE------__-_ _ � w (,' poi,�;lf r�,,�n _ ______j rla — J a \c i PROPER `�,o °9/366�e 0 T1'LINE ROFESSIONP-- PV2 06/19/2024 ( 1 0. i aw JE 18" VENTILATION SETBACK 3' WIDE FIRE ACCESS PATHWAY 0_ r-i ';-1 / 2' 2' re I' 18' L\/ 18' li 18' 18' z o 2 • _al— ——— .-•— •--— •--•� - • • i. � �• t•l •1IV :olittlIto...•totot.t.t.t � •• •t.t.t.itotoGitt ! ..... . • ---ok --. Alt o. ---.--- .-- .%°101 a >co 00 Z 0 RI 03 'Ci' • • - -- ---•- --♦— -a——•-——— t--0---♦ --.— ---• --- j 0 'fit 0 ` -- � w '� m H •- --•--- -- .--- - ---.--- ---♦---.- -- -- — --- .---.- --. --- �� i / c0 co cV // W p ao V) �� I 1- co ~ J �- 38' -I 38' o MP1 o a ° F-.... TILT: 22° MP2 AZIMUTH: 98° SOLAR MODULE TILT: 22° �o J ce a Q AZIMUTH: 278° o a Q Q N I- n N 0 °' o \� w J DATE Design Criteria: 06/18/2024 TYPE DESCRIPTION QUANTITY ROOF SPECIFICATION •Applicable Codes=2020 Residential Code of NYS,ASCE 7-16,and NDS-18 \ 1 •Ground Snow Load=50 psf;Roof Snow Load=34.7 psf ARRAY 1-2 / DESIGNED BY: 1 LONGI SOLAR LR5-54HABB-400M(40(W)SOLAR • Basic Wind Speed=110 mph Exposure Category C OS M MODULE MODULES 27 ROOF MATERIAL ASPHALT SHINGLE • Existing Roof Dead Load:ARRAY 1-2=10 psf \ �7 • Existing Roof Live Load:19.2 psf �OF NEWY I' 1 MICROINVERTER ENPHASE IQ8PLUS-72-2-US MICROINVERTER 27 RAFTERS 2"X 6"@ 16"O.C. pV K'ZAoy�O.p� tt�i ,t+i? a* \ J 125A ENPHASE IQ COMBINER PANEL 5/5C ROOF CONDITION �� i by W' 04 t COMBINER 1 GOOD 6 t P0§1365e��i DISCONNECT 60A FUSED AC DISCONNECT 1 AROFESSIONP pV3 \ 06/19/2024 a II D 2 IRONRIDGE(XR10)RAILS LL IRONRIDGE RELEASE LINER � 8 '-k.-,...___________----------;‘, A i (QUICK MOUNT / \ HALO ULTRAGRIP) b. / Soll11111111.' � V �rZ 0C7�'0WOOD SHEATHING ' V W t} q14 RD STRUCTURAL SCREW m Gj Z H- Ix Z CO m WOOD ROOF 1- TRUSS TYP. DO M �! IRONRIDGE(XR10)RAILS ILI o ti J IRONRIDGE(QUICKMOUNT HALO ULTRAGRIP) � `N 0 , 0 / a SOLAR MODULE J w co Ird�°' q a � allo ""_.. -'" ,_; RELEASE LINER Z a k } ..............<111-- 11 DATE `06/18/2024 l DESIGNED BY: 1 WOOD ROOF TRUSS TYP. ` OS M J WOOD SHEATHING �OF NElv}, r STRUCTURAL ATTACHMENT DETAILS '�J�,K.zqey O, a ':t. �Su try ' I1i !all a 04 r 1 A,pOFESSIONP\• \ 06/19/2024 i " 7 0. CO DL9 Project D0.ils Roof M100 A y Mane Robed Mcleod Date 06'14't024 Might 1511 slope 22• Rafter spacing ten Bin of Materials Ma Location 14 Bennett Road.Qtee,ndoy,NY 12001 Total moduks 27 Pad Spares Toth Qty _ E Module Lon01 Solari LR55.NAB0-W0M(30nso) Total wa 800 tt. 10 Rolls a Splices a. Dlmanabns Deen5dts.67.g'•N65'a LAW(172201Tm•11310mm•30.01nm) Attachments 60 0R.10168A 0 20 8 ASCE 7-16 Rnila per 2 10110.P.„�aw \ J 0R10AOSS-01-MI 0 B / Clomps 0105a I •YW• Clomps 4 Grounding UFO-CL-01A1 0 42 Mew.1bawrMs,Clem l'1•610017A1 IX 0 Td N I Ir' `11 !'.1 c+ona.atwln.rta�e o 6 Q Z 1 Alteclunentn f 03 • Im 6 66 W J W tt_ I NV410143001-M1 U •J PD Souct.Y 5owe10. 12 132 a. /A 2 ` O a dnM.4'tdW CS o .aw.q.WeM.e spin..column. ��// • eNW.sQO2a 6 66 N saaaaA mmg N9dwe LL Accessories W ...e. ..-.....�......... _..__ Z. QQMB0001aU 0 4 co Solent Weight _- Total system weight 1S20.7lbs Weight/atechmcm 253Es m RecWng awlght 121.501 'a' Distributed weight 26psi \ \\/ Roll Information00 M N Roof Material PMN an ly Ct SW W1 of Ro Randal Camp S � O I,: W RNA ratsmery II Roof o1achmenl Nab l00aGdp(Rafter scathed) I— J Staggered attachments Yes r. Atbchmem6ardwe Square %^ Root shape Gat* 0 Gat* ss, Specific gravity 042 ` 0 < C / O J 1 (4) J III a > co ..- O a meZ s. c J DATE `06/18/2024 C DESIGNEDEDe BY: OSM J sof NEh,Y c J,1k.240 O,p� I11 !• 't}h�j,4 :n , by •tuft' 04 J tb,o°�13651 PV5 "FESS° 06/19/2024 ( l E , > t Q. N 0 200A IJ J 1 125A ENPHASE IQ MAIN SERVICE a 1 1 STRING OF JUNCTION PANEL $ 09 MODULES WITH BOX COMBINER PANEL 5/5C 60A AC 120/240V MICROINVERTERS cENVOY IQ Z. DISCONNECT Z. \.. ) rn t 15A/2P FUSED 200A _ °o z a 1 STRING OF I/ I I 20A/2P 50A/2P •' I o 09 MODULES WITH •20A/2P - M ems < re W MICROINVERTERS e r- . ri m ��- G N UM w � w 1 STRING OF z z G n n win 9 MODULES WITH �, U MICROINVERTERS G N - / rc. 00 ch N . e 0 4 WonIA co 2 0 o a 2/ GEC lw o a VJ w = g a in _ c Z a k } CONDUCTORS AND CONDUIT ` MODULES ` INVERTER(S) J ` OTHER EQUIPMENT ' 0 0 J (27)LONGI SOLARSOLAR LR5-54HABB-400M (27)ENPHASE IQ8PLUS-72-2-US (1)125A ENPHASE IQ COMBINER PANEL 5/5C O (3)ENPHASE Q CABLES O (3)#6 THHN MICROINVERTER (1)60A FUSED AC DISCONNECT DATE (1)#6 THHN GND (400W)SOLAR MODULE 3/4"EMT (1)#6 THHN GND 06/18/2024 3/4"EMT WATTS STC:400W INV OUTPUT CURRENT:1.21 A \ J J (6�10 THHN ISC:13.72A MAX AC OUTPUT:27X1.21 =32.67 A DESIGNED BY: © (1)#6 THHN GND INVERTER OCPD CALC:(32.67)X 1.25= IMP:12.93A 40.84A STRUCTURAL ONLY ` OS / 3/4"EMT VOC:37.05V MIN OCPD:50A *,OF NEWY c • © (3)#10 THHN VMP:30.94V J� 2q�y O.p (1)#6 THHN GND WIRE AMPACITY:65A @75°C TERMINAL 1q'i ,it 11�*'' \ l 3/4"EMT ( 1 f cc 04 1 TEMPERATURE CORRECTION FACTOR: 31°-35°C=0.96 P413653f �'� CORRECTED WIRE AMPACITY:62.40A ARCFESSIONP� PV6 1 - -- --- - J 06/19/2024 / ( \ I > t� dl 125A ENPHASE IQ (. 1 COMBINER PANEL 5/5C J ( ENVOYIQ) 200A 0- $ 1 STRING OF JUNCTION 'I MAIN SERVICE ` l 09 MODULES WITH 15A/2P BOX — PANEL MICROINVERTERS V / A 20 2P 60A AC 120/240V 2 o D DISCONNECT `8 n Q w Wa 1 STRING OF 20 2P co FUSED __ 200A a il a 09 MODULES WITH I--« n 50A/2P A Fre I W NMICROINVERTERS 20 2P I �0 . rt o L ( 0�i _ - re w 1 STRING OF Z UM co Tr 9 MODULES WITH V I- G N — MICROINVERTERS 1 G N co cn N . . I 0 H O ti J 4 IG '�� CO o a 0 — GEC vJ w -9 g a m I— D E N J CONDUCTORS AND CONDUIT ` MODULES J ` INVERTER(S) OTHER EQUIPMENT ) v °" M z (27)LONG!SOLARSOLAR LR5-54HABB-400M (27)ENPHASE IQ8PLUS-72-2-US (1)125A ENPHASE IQ COMBINER PANEL 5/5C O (3)ENPHASE Q CABLES ° J (1) THHN GND O (3)#6 THHN (400W)SOLAR MODULE MICROINVERTER (1)60A FUSED AC DISCONNECT ' DATE EMT#6 (1)#6 THHN GND 06/18/2024 3/4" 3/4"EMT WATTS STC:400W INV OUTPUT CURRENT:1.21 A ` J \ MAX AC OUTPUT:27X1.21=32.67 A / DESIGNED BY: 1 © (6)#10 THHN ISC:13.72A INVERTER OCPD CALC:(32.67)X 1.25= (1)#6 THHN GND IMP:12.93A 40.84A �SM 3/4"EMT STRUCTURAL ONLY VOC:37.05V MIN OCPD:50A t.OF NE14,Y f 1 © (3)#10 THHN VMP:30.94V I(240y F�O.p, (1)#6 THHN GND WIRE AMPACITY:65A @75°C TERMINAL R91.. .f' * 3/4"EMT 1 .n , 1Y o: 04 TEMPERATURE CORRECTION FACTOR: W 31"-35°C=0.96 v41365 , 4i CORRECTED WIRE AMPACITY:62.40A AROFESSIONP' PV6.1 06/19/2024 / / \ 0 ' • \/LL 1 . W I INVERTER AC DISCONNECT MAIN SERVICE PANEL (9 1 NEC 690.13(4) NEC 690.14(C)(2) NEC 705.12(D)(4)),690.56(B) J i WARNING PHOTOVOLTAIC DISCONNECT POWER IS BEIN RN SUPPLIED TO THIS a ELECTRIC SHOCK HAZARD. FOR UTILITY OPERATIONS PANEL FROM THE UTILITY AND A DO NOT TOUCH TERMINALS. SOLAR PV SYSTEM. TERMINALS ON BOTH LINE AND NEC 690.54 NEC 705.12(D)(7) o: LOAD SIDES MAY BE ENERGIZED IN _1 inm THE OPEN POSITION. RATED AC OUTPUT CURRENT:32.67 A WARNING NOMINAL AC VOLTAGE: 240 V INVERTER OUTPUT CONNECTION g v co NEC 690.14(C)(2) NEC 690.56 DO NOT RELOCATE THIS °� o 0 OVERCURRENT DEVICE z w r4 co EMERGENCY RESPONDER Y m PHOTOVOLTAIC DC DISCONNECT LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED 2 w THIS SOLAR PV SYSTEM BREAKER.IF INSTALLED ANYWHERE ELSE ON DEADFRONT EQUIPPED THEN A PERMANENT ARROW FROM LABEL POINTING TO m WITH RAPID SHUTDOWN PV BACKFEED BREAKER REQUIRED. PHOTOVOLTAIC TURN RAPID SHUTDOWN NEC 690.54 �� SWITCH TO THE CN SYSTEM EQUIPPED WITH •ONDUCT RSINSIDETION ONLY �� 1 c CO CONDUCTORS INSIDE sowae�rnuc� �. p g CO w BUILDING OR OFF THE % '"""� !i, RATED AC OUTPUT CURRENT: 32.67 A w , t, W RAPID SHUTDOWN ROOF WILLSHUTDOWN NOMINAL AC VOLTAGE 240 V o Sectiane of the PV system pid shut doe+t,in Na rapid 1111111 J O ehutdam Itch Is operated. N Section,a/the PV system that NEC 690.14(C)(2) 8 C are not,het door,hen the rapid snatda.n e.lt°^I,apexated Q G NEC 5 CONDUIT, RACEWAYS, > PHOTOVOLTAIC ARRAY DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT g J P NOMINAL OPERATING AC VOLTAGE: 240 V ENCLOSURES, CABLE U NOMINAL OPERATING AC FREQUENCY: 60HZ — g. k MAX.AC POWER: 290 VA ASSEMBLIES z 3 MAX AC CURRENT: 121 A MAX OV RC RRENT.DEVICE RATING FOR AC & JUNCTION BOXES `" a 2 ' MODULE PROTECTION PER CIRCUIT:20A NEC 690.31(D)(2)CONDUIT DATE ` `06/18/2024 Warning: Photovoltaic Power Source DESIGNED BY: OSM NEC 690.35(F)UNGROUNDED SYSTEMS JUNCTION BOX STRUCTURAL ONLY J OF NEt1r / WARNING '1 K• y0.p. ELECTRIC SHOCK HAZARD. %27-N,I: F�' t THE DC CONDUCTORS OF THIS n' . ' 'zY re' 04 PHOTOVOLTAIC SYSTEM ARE \F � ;- UNGROUNDED AND MAY BE 6, P�13652,e. t�.'� ENERGIZED. AROOEss►O' PV7 06/19/2024