Loading...
2024-0063 Office Use Only /Ce, ADDITION ALTERATION PERMIT .. ao � Permit#: 2� Town ofQ uce b ry APPLICATION Permit Fee:$ 2 �32• )� 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensbury.net Invoice#: .0 —. ko Flood Zone? Y N Reviewed tQ . Project Location: 751 Glen Street, Queensbury, NY 12804 Tax Map ID#: 302.6-1-25 Subdivision Na tt PROJECT INFORMATION: FEB 0 2 2024 1),, TOWN OF QUEENSBURY TYPE: ❑ Residential I Commercial, Proposed Use: Bagel_&�ColffeeShop CODES ❑ Single-Family ❑ Two-Family ❑ Multi-Family(#of units_) ❑ Townhouse ❑ Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ❑ Other(describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 7,522 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total sq ft: Total sq ft: 7,522 Scope of work to be done: Work includes the fit-up of the existing Recovery Room Resturant for use as the Uncommon Grounds Coffee& Bagels shop. The work includes the installation of new finishes including ceilings, new lighting throughout the space and installation of new serving counters with equipment. The existing kitchen will be renovated and include new cooking and baking equipment. The existing rooftop HVAC equipment will remain and existing ductwork will be modified to accomodate the new layout. The existing fire sprinkler system will also be modified to accomodate the new layout. Addition/Alteration Application Revised June 2022 . ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 375,000 2. Source of Heat (circle one): ® Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES NO Explain: 4. Are there any easements on the property? ® YES ❑ NO SITE INFORMATION: • Is this a corner lot? ❑ YES © NO • Will the grade be changed as a result of the construction? ❑ YES .1 NO • What is the water source? I] PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? 0 SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Richard E. Jones SIGNATURE: ‘4,1g DATE: 01-16-2024 Addition/Alteration Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Richard E. Jones, Architect Mailing Address, C/S/Z: 339 Aviation Road, Queensbury, NY 12804 Cell Phone: )518-791-1960 Land Line: ( )518-793-1015 x 311 Email:richardjones@rejaarchitects.com • Primary Owner(s): Name(s): Upper Glen Street Associates (Contact: Brad Pringle) Mailing Address, C/S/Z: 20 Corporate Woods Blvd., Albany, NY 12211 Cell Phone: ( )518-626-1866 Land Line: ( )518-436-8421 Email:bprinel@nigroproperties.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: Contact Person for Compliance in regards to this project: Ave?kiC0A. Cell Phone: ( ) Land Line: ( ) Email: • Addition/Alteration Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Richard E. Jones,Architect Mailing.Address,-C/S/Z: 339 Aviation Road,Queensbury, NY 12804 Cell Phone: ( )518-791-1960 Land Line: ( )518-793-1015 x 311 Email:richardjones@rejaarchitects.com • Primary Owner(s): Name(s): Upper Glen Street Associates (Contact: Brad Pringle) Mailing Address, C/S/Z: 20 Corporate Woods Blvd., Albany, NY 12211 Cell Phone: ( )518-626-1866 Land Line: ( )518-436-8421 Email:bprinel@nigroproperties.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Huntington Construction, Inc. dba EMCO Construction (Contact: Kevin Huntington) Contractor Trade: General Construction and all associated trades Mailing Address, C/S/Z: 4 Kelch Drive, Suite 208, Malta, NY 12020 Cell Phone: ( 518 ) 857-0058. Land Line: ( 518 )456-1853 Email: kevinh@emcoconstruction.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Richard E.Jones Associates,Architects Contact Name(s): Richard E. Jones,AIA Mailing Address, C/S/Z: 339 Aviation Road, Queensbury, NY 12804 Cell Phone: ( 518 )791-1960 Land Line: ( 518 )793-1015 x 311 Email: richardjones@rejaarchitects.com Contact Person for Compliance in regards to this project: Richard E.Jones,AIA Cell Phone: ( 518 ) 791-1960 Land Line: ( 518 )793-1015 x 311 Email: richardjones@rejaarchitects.com Addition/Alteration Application Revised June 2022 1�\ FIRE MARSHAL'S OFFICE _s Town of Queensbury f � 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live" PLAN REVIEW Uncommon Grounds 751 Glen St, Ste #1 CC-0061-2023 7522 S.F. Comm Interior Alterration 2/14/23 I have reviewed the submitted drawings for the above project; and offer the following comments: 1) Locks / latches shall comply with 2020 NYSFC. 2) Verify operation of exit/emergency lights, include egress corridor 3) Verify paths of egress 4) CO Detection required 5) EVAC plan for both egress points 6) Provide all documents for Fire alarm system NFPA 72 -System Layout -NYS License for installer -Spec. sheets for all appliances and equipment -Ansul system tie in -Sprinkler system monitoring -Central station monitoring -A witness function test by the FM office is required -HVAC shutdown is required Fire Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 firemarshal@queensbury.net • www.queensbury.net 7) NFPA 13 letter of compliance required for any modifications to the Sprinkler System 8) Knox Box required for fire department/ provide a key 9) Verify Storage 10) FM to provide Max OCC signage 11) Protection of the Fire Alarm system during construction According to the 2020 NYSFC Chapter 33 Deputy Fire Marshal Tyson Converse 742 Bay Road Queensbury NY 12804 518 761 8205 tysonc@queensbury.net Tyson Converse 742 Bay Road Queensbury NY 12804 518 761 8205 tysonc@queensbury.net Fire Marshal 's Office ■ Phone: 518-761-8206 • Fax: 518-745-4437 firemarshal@queensbury.net ■ www.queensburi.net Richard E. Jones Associates Architects- Environmental Planners 339 Aviation Road Queensbury,NY 12804 Telephone(518) 793-1015 Fax(518)793-2223 E-mail:richardjones@rejaarchitects.com July 12,2024 John O'Brien,Building Inspector Town of Queensbury Building Department 742 Bay Road Queensbury,NY 12804 Re: Building Permit#2024-0063 Building Certification for Bagel&Coffee Shop Fit-up Uncommon Grounds 751 Glen Street Queensbury, New York Dear John: To the best of my knowledge and belief the construction for the Uncommon Grounds renovation project has been substantially completed as required to obtain a final certificate of occupancy. Work has been completed in accordance with the submitted and approved plans and specifications and conforms to the 2020 Building Codes of New York State including the Energy Conservation Construction Code. Should you have any questions with regard to this Letter of Certification do not hesitate to contact me. Sincerely, 0. a so. Richard E.Jones,AIA P:\01-Projects\2022\2022-11 Uncommon Grounds-Queensbury\Regulatory Agency\Sign Off Letter 07-12-2024.doc + � a' y " x a � x- rri � .1Y as s -VK � "7 10 A"44 c ;tr. w" , .� . i3 Q� :*y cfs� _ � rflc{ ' > a <�� tsi ^ ;;- r '^'4. �b` >`e k [ ` r } 4 � _k4`' i� Fi C' ' .Zx 14 c aa r r v�.' �—� ' � �:1 e I fi vM. ix `� wr i- ` - `, v i, ,„+ r lit: ,', t ,-. ?L .e BP/5264 Rev. 11 /23 Commonwealth Electrical Inspection service, Inc. tos.„4...._..../4........: ..e---if 7e../ only has been isually inspected - and - certified as of this date pursuant to applicable codes. 6/(77,-s/ v, 0 ,2 C.7 .1, Date Lnspector • 5iee Air Ji c 7 COMcheck Software Version COMcheckWeb (iInterior Lighting C�~A^'1 � � 41 302.E-1-25 2024-0063 , Uncommon Grounds 751 Glen St Project Information Interior Alterations 7522 s.f. Energy Code: 2018 IECC Project Title: Uncommon Grounds - Queensbury Copy 2 Copy 2 Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 751 Glen Street Uncommon Grounds Richard Jones Queensbury, New York 12804 751 Upper Gle Street Richard E.Jones Associates Queensbury, New York 12804 Architects 339 Aviation Road FILE COPY i----- .- --_.^__.__ _ Que518 ensbury, 7931015 New York 12804 ✓ I �. �— D 1 _�^- i5� '',1')•: ;'• I:i .richardjones@rejaarchitects.com r I i Allowed Interior Lighting Power 1i - nzB 0, tiR il1ifl I A !'11�1l1 /t_+� c B C D Area Category i liF -�(..o�lF�loor Area Allowed Allowed g nr _---- _f3i _ 0, �L.i ES (ft2) Watts /ft2 Watts 1-Dining&Serving area (Common Space Types:Dining Area-Cafeteria/Fast 4169 0.63 2626 Food) 2-Kitchen (Common Space Types:Food Preparation) 2040 1.06 2162 3-Storage& Utility space (Common Space Types:Storage >=50- <=1000 936 0.46 431 sq.ft.) 4-Mens&Womens Toilet Rooms (Common Space Types:Restrooms) 377 0.85 320 Total Allowed Watts = 5540 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp/Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Dining & Serving area (Common Space Types: Dining Area - Cafeteria/Fast Food. 4169 sq.ft.) LED: Cl: Chandelier: LED A Lamp 12W: 2 1 24 24 LED: C2: Chandelier: LED A Lamp 12W: 2 6 24 144 LED: C3: Chandelier: LED A Lamp 12W: 2 1 24 24 LED: Pl: Pendant: LED A Lamp 8W: 1 11 8 88 LED: P2: Pendant: LED MR 6W: 1 4 6 24 LED: P3: Pendant: LED A Lamp 12W: 2 1 24 24 LED: Ll: Ceiling Mount w/Swivel Arm: LED PAR 16W: 2 1 32 32 LED: L4: 6" Dia. Recessed: LED PAR 18W: 1 2 18 36 LED: Si:Wall Sconce: LED A Lamp 9W: 1 2 9 18 Track Lighting:Tl:Track: Wattage based on 309 feet of track 0 0 2472 2472 Kitchen (Common Space Types: Food Preparation. 2040 sq.ft.) LED: L2: Lay-in: LED Panel 33W: 1 18 45 810 Storage & Utility space (Common Space Types: Storage >=50 - <=1000 sq.ft.. 936 sq.ft.) LED: L2: Lay-in: LED Panel 33W: 1 12 30 360 Mens & Womens Toilet Rooms (Common Space TiCpEVR trochas. J711q.ft.) ENERGY CODE COMPLIANCE Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 1 of 6 A B C D E Fixture ID : Description / Lamp/Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. LED: S2:Wall Sconce: LED A Lamp 8W: 1 4 8 32 LED: 53:Wall Sconce: LED A Lamp 8W: 2 2 16 32 LED: L4: 6" Dia. Recessed: LED PAR 18W: 1 13 18 234 Total Proposed Watts= 4354 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checkllist. Richard E. Jones, Architect / ol _ 02-01-2024 Name-Title Signature Date . cs �O DWI J` .fb�'.� qy 1/41 � '... t • • O ��, 0•400 �$ Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 2 of 6 t COMcheck Software Version COMcheckWeb (6 Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 3 of 6 Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. ;Spaces required to have light- ❑Complies Requirement will be met. 2 reduction controls have a manual ❑Does Not [EL22]1 ;control that allows the occupant to `reduce the connected lighting load in ❑Not Observable la reasonably uniform illumination Observable,__, Applicable !pattern >= 50 percent. C405.2.1, Occupancy sensors installed in ❑Complies Exception: Requirement does not apply. C405.2.1. classrooms/lecture/training rooms, ❑Does Not 1 !conference/meeting/multipurpose [EL18]1 !rooms, copy/print rooms, Not Observable !lounges/breakrooms, enclosed offices, ❑Not Applicable !open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces<= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 ;for open plan office spaces. C405.2.1. !Occupancy sensors control function in ❑Complies Exception: Requirement does not apply. 2 !warehouses: In warehouses,the ❑Does Not [EL19]1 !controlled in aisleways and open areas is pilot Observable `controlled with occupant sensors that automatically reduce lighting power ❑Not Applicable !by 50%or more when the areas are !unoccupied.The occupant sensors !control lighting in each aisleway ;independently and do not control !lighting beyond the aisleway being ;controlled by the sensor. C405.2.1. I Occupant sensor control function in ❑Complies Exception: Requirement does not apply. 3 !open plan office areas: Occupant DDoes Not [EL20]1 ;sensor controls in open office spaces '>= 300 sq.ft. have controls 1) ❑Not Observable configured so that general lighting can ❑Not Applicable !be controlled separately in control !zones with floor areas<= 600 sq.ft. !within the space, 2) automatically turn I off general lighting in all control zones !within 20 minutes after all occupants !have left the space, 3) are configured !so that general lighting power in each control zone is reduced by >= 80%of the full zone general lighting power !within 20 minutes of all occupants !leaving that control zone, and 4) are ;configured such that any daylight !responsive control will activate space !general lighting or control zone ;general lighting only when occupancy 'for the same area is detected. C405.2.2, !Each area not served by occupancy '❑Complies Requirement will be met. C405.2.2. !sensors (per C405.2.1) have time- ❑Does Not 1, ;switch controls and functions detailed C405.2.2. !in sections C405.2.2.1 and C405.2.2.2. [Not Observable 2 ! ❑Not Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 4 of 6 • Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, 1 Daylight zones provided with DComplies Exception: Requirement does not apply. C405.2.3. i individual controls that control the ❑Does Not 1, }lights independent of general area C405.2.3. 1 lighting. See code section C405.2.3 ❑Not Observable 2 I Daylight-responsive controls for ❑Not Applicable [EL23]2 ;applicable spaces, C405.2.3.1 Daylight 3 responsive control function and II section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for DComplies Requirement will be met. [EL26]1 specific uses installed per approved ❑Does Not lighting plans. [Not Observable ❑Not Applicable C405.2.4 {Additional interior lighting power ❑Complies Requirement will be met. [EL27]1 I allowed for special functions per the ❑Does Not ;approved lighting plans and is !automatically controlled and ['Not Observable ;separated from general lighting. ❑Not Applicable C405.3 ;Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 Iface. ❑Does Not ❑Not Observable ❑Not Applicable C405.6 1 Low-voltage dry-type distribution DComplies [EL26]2 ;electric transformers meet the ODoes Not minimum efficiency requirements of Table C405.6. ❑Not Observable ❑Not Applicable C405.7 I Electric motors meet the minimum DComplies [EL27]2 ;efficiency requirements of Tables EDoes Not IC405.7(1)through C405.7(4). 1 Efficiency verified through certification ❑Not Observable I under an approved certification ❑Not Applicable J program or the equipment efficiency ratings shall be provided by motor I manufacturer(where certification programs do not exist). C405.8.2, !Escalators and moving walks comply DComplies C405.8.2. ;with ASME A17.1/CSA B44 and have ❑Does Not 1 ;automatic controls configured to [EL28]2 ;reduce speed to the minimum DNot Observable 3 permitted speed in accordance with ❑Not Applicable )ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C405.9 Total voltage drop across the DComplies [EL29]2 ;combination of feeders and branch ❑Does Not circuits <= 5%. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 5 of 6 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ❑Does Not 2 ;building owner or designated [FI17]3 ;representative. [Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting [Not Observable :plans, demonstrating proposed watts I are less than or equal to allowed ❑Not Applicable watts. C408.1.1 {Building operations and maintenance ❑Complies [F157]1 !documents will be provided to the ❑Does Not :owner. Documents will cover manufacturers' information, ❑Not Observable specifications, programming ElNot Applicable procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. C408.2.5. ;Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ❑Does Not [FI16]3 ;of system acceptance. [Not Observable { ❑Not Applicable • C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [FI33]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Uncommon Grounds-Queensbury Copy 2 Copy 2 Report date: 02/01/24 Data filename: Page 6 of 6