2024-0369(2)GENERALNOTES 1. DESIGNED IN ACCORDANCE WITH 2O20 BUILDING CODE OF NYS (2018 IRC WITH NEW YORK STATE AMENDMENTS. IT IS THE INTENT OF THESE DRAWINGS IS TO COMPLY WITH ALL BUILDING CODE REQUIREMENTS AND ASSOCIATED REFERENCED STANDARDS WITHIN THE BUILDING CODE OR SPECIFIED HEREIN. WHERE ANY DISCREPANCY EXISTS THE MORE STRINGENT SHALL GOVERN THE CONTRACTORS BID AND CONSTRUCT IONNVORK, HOWEVER IN NO CASE SHALL WORK BE INSTALLED OR COMPLETED WHICH IS NOT IN CONFORMANCE WITH THE REQUIREMENTS OF ANY CODE SECTION OR REFERENCED STANDARD. 2. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES IN DIMENSIONS OR ELEVATIONS. 3. DO NOT CHANGE SIZE OR SPACING OF BUILDING COMPONENTS OR STRUCTURAL MEMBERS. CONTRACTOR SHALL NOTIFY ENGINEER OF PROPOSED DEVIATIONS OR SUBSTITUTIONS FROM DIMENSIONS OR MATERIALS SHOWN ON THE DRAWINGS AND MAKE ONLY THOSE DEVIATIONS OR SUBSTITUTIONS ACCEPTED BY ENGINEER. 4. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS, DETAILS, OR PROVISIONS FOR MEANS AND METHODS OR FOR CONSTRUCTION SAFETY. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS AND METHODS AND CONSTRUCTION SAFETY, INCLUDING BUT NOT LIMITED TO DESIGN AND IMPLEMENTATION OF ANY REQUIRED TEMPORARY CONDITIONS OR SHORING REQUIRED FOR PHASING, SEQUENCING, OR IMPLEMENTATION/INSTALLATION OF WORK SPECIFIED. 5. DESIGNED PER 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NYS (2018 INTERNATIONAL ENERGY CONSERVATION CONSTRUCTION CODE WITH NYS AMENDMENTS). 6, ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED IN THE RESIDENTIAL CODE SHALL BE PROVIDED WITH A MANUFACTURERS LABEL, DESIGNATING THE TYPE AND THICKNESS OF GLASS AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES. SEE MINIMUM CATEGORY CLASSIFICATION OF GLAZING TABLE ON DRAWING #7 FOR GLAZING CLASSIFICATIONS AND REQUIREMENTS. 7. BUILDING SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 680F AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN HABITABLE ROOMS AT THE DESIGN TEMPERATURE. 8. TOILET, BATH, AND SHOWER FIXTURES SHALL BE SPACED IN ACCORDANCE WITH THE MINIMUM FIXTURE CLEARANCES DIAGRAM ON DRAWING #7. 9. ALL CO AND SMOKE ALARMS REQUIRED SHALL BE INTERCONNECTED. ALARMS SHALL BE CONNECTED TO THE PRIMARY BUILDING POWER SOURCE AND SHALL CONTAIN BATTERY BACK-UP. 10. ALL FOAM PLASTIC OR FOAM PLASTIC CORES OF MANUFACTURED ASSEMBLIES SHALL BE COVERED WITH MINIMUM 1/2 INCH GYPSUM BOARD WHICH IS MECHANICALLY FASTENED TO SUPPORT STRUCTURE. 11. IN ALL FRAMED WALLS, FLOORS, AND ROOF/CEILINGS COMPRISING ELEMENTS OF THE BUILDING THERMAL ENVELOPE, A 4-MIL POLY VAPOR RETARDER SHALL BE INSTALLED ON THE WARM SIDE OF INSULATION. 12. FIRE -BLOCKING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS BOTH VERTICAL AND HORIZONTAL BETWEEN BUILDING STORIES. BLOCKING SHALL BE INSTALLED VERTICALLY AT CEILING AND FLOOR LEVELS, AND IN ALL VERTICAL OR HORIZONTAL CAVITIES EXCEEDING 10 FT IN LENGTH OR HEIGHT AT INTERVALS NOT TO EXCEED 10 FEET. BTTTS OR BLANKETS OF MINERAL OR GLASS FIBER INSULATION OR SOLID WOOD BLOCKING SHALL BE USED FOR FIRE -BLOCKING. REFER TO R302.11 FOR ADDITIONAL REQUIREMENTS. 13. ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQUARE FEET. OPENINGS SHALL BE MINIMUM 22 INCHES BY 30 INCHES AND SHALL HAVE A MINIMUM 30 INCH UNOBSTRUCTED HEADROOM HEIGHT. VERIFY AND COORDINATE LOCATION(S) IN FIELD WITH BUILDER/OWNER. 14. THE PLANS HEREIN HAVE BEEN DESIGNED FOR A DEAD LOAD OF 10 PSF FOR EACH FLOOR AND ROOF LEVEL, LIVE LOADS SPECIFIED IN THE UNIFORM LIVE LOAD TABLE, AND THE ROOF SNOW LOAD, AS A SINGLE FAMILY DWELLING, AND FOR OTHER REGIONAL OR CLIMACTIC DATA IN THE DESIGN CRITERIA TABLE THIS DRAWING. 15. HABITABLE ROOMS HAVE BEEN DESIGNED TO PROVIDE NATURAL LIGHT AND VENTILATION AT A RATE OF 8% AND 4% RESPECTIVELY. FOR @BITABLE WHERE EITHER IS NOT PROVIDED, ARTIFICIAL LIGHTING AND MECHANICAL VENTILATION SHALL BE PROVIDED. 8EE TABLE PROVIDED FOR INDIVIDUAL ROOM CALCULATIONS AND COMPLIANCE REQUIREMENTS ON DRAWING #2. WHERE WHOLE HOUSE VENTILATION SYSTEMS ARE INSTALLED THAT MEET THE VENTILATION DEMAND FOR THE ENTIRE THERMAL ENVELOPE IN ACCORDANCE WITH M1505.4, THE GLAZED AREA OF A HABITABLE ROOM NEED NOT BE OPENABLE (R303.1 EXCEPTION 1), 8:12= 16. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACE, AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH GYPSUM BOARD. 17. A MECHANICAL WHOLE -HOUSE VENTILATION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH M1507.3 PROVIDING A CONTINUOUS AIRFLOW RATE AS SPECIFIED OR INTERMITTENTLY OPERATING 25% OF EACH 4-HOUR SEGMENT WITH A MINIMUM AIRFLOW RATE AS SPECIFIED. INTAKE AND EXHAUST OPENING LOCATIONS SHALL BE COORDINATED WITH RESTRICTIONS OUTLINED IN R303.5. INCLUDE FINISHED BASEMENTS OR FUTURE SPACES IN THE SIZING OF SUCH SYSTEMS. CONTINUOUS WHOLE -HOUSE MECHANICAL VENTILATION; DWELLING SIZE 1BR 2-3BR 4-5BR 1500 SF 30CFM 45CFM 60CFM 1501-3000 SF 45CFM 60CFM 75CFM 3001-4500 SF 60CFM 75CFM 90CFM 4501-6000 SF 75CFM 90CFM 105CFM INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION; PERCENT OF CONTINUOUS RUN TIME IN EACH 4-HR SEGMENT - MIN CFM REQ'D 25%- MULTIPLY REQ'D CONTINUOUS VENTILATION ABOVE BY FACTOR OF 4 33% - MULTIPLY REQ'D CONTINUOUS VENTILATION ABOVE BY FACTOR OF 3 50%- MULTIPLY REQ'D CONTINUOUS VENTILATION ABOVE BY FACTOR OF 2 66% - MULTIPLY REQ'D CONTINUOUS VENTILATION ABOVE BY FACTOR OF 1.5 75% - MULTIPLY REQ'D CONTINUOUS VENTILATION ABOVE BY FACTOR OF 1.3 18. INTERIOR AND EXTERIOR STAIRS AND LANDINGS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS TO A LEVEL OF NOT LESS THAN 11 LUX OR 1 FC. A SWITCH OPERATING LIGHTING SHALL BE INSTALLED AT EACH FLOOR LEVEL THAT ACCESSES THE STAIRWAY. REFER TO STAIR NOTES ON DRAWING #7 FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 19. BASEMENTS, HABITABLE ATTICS, AND EVERY SLEEPING ROOM SHALL BE PROVIDED WITH AN EMERGENCY ESCAPE AND RESCUE OPENING OPENING DIRECTLY TO THE EXTERIOR PUBLIC WAY. OPENINGS SHALL BE OPERATIONAL FROM THE INTERIOR WITHOUT THE USE OF SPECIAL DEVICES, KEYS, OR TOOLS. PROVIDE A MINIMUM OPENING OF 5.7SF FOR ABOVE GRADE LEVELS, AND 5.OSF AT OR BELOW GRADE. OPENINGS SHALL HAVE A MINIMUM CLEAR HEIGHT OF 24-INCHES AND CLEAR WIDTH OF 20-INCHES. SILL HEIGHTS FOR ESCAPE AND RESCUE OPENINGS SHALL NOT BE INSTALLED HIGHER THAN 44-INCHES ABOVE THE FLOOR. BASEMENT ESCAPE OPENINGS SHALL HAVE A WINDOW WELL INSTALLED IF GRADE IS ABOVE THE OPENING SILL ELEVATION (HORIZONTAL PROJECTION OF 3 FT FROM WALL FACE AND MINIMUM AREA OF 9 SF). WINDOW WELL FLOORS MORE THAN 44-INCHES BELOW ADJACENT GRADE SHALL HAVE LADDERS OR STEPS INSTALLED COMPLYING WITH R310.2.3.1. EXIT DOORS MAY BE USED TO SATISFY ESCAPE AND RESCUE REQUIREMENTS. 20. EACH HOME SHALL BE AIR -LEAK TESTED IN ACCORDANCE WITH ASTM E 779 OR ASTM E 1827 AND SHALL NOT EXCEED 3 AIR CHANGES PER HOUR. 21. ENERGY CODE COMPLIANCE FOR THIS HOME UTILIZES THE TOTAL UA ALTERNATIVE OUTLINED IN R402.1.5. SEE PROJECT SPECIFIC RESCHECK CERTIFICATION AND CALCULATIONS FOR MINIMUM INSULATING AND PERFORMANCE REQUIREMENTS OF THE THERMAL ENVELOPE. 22. INSULATING BAFFLES SHALL BE INSTALLED ABOVE INSULATION IN VENTED ATTICS BETWEEN EACH RAFTERS OR TRUSS CAVITY WITH ONE END NEAR THE VENTED SOFFIT AND THE OTHER EXTENDED ALONG THE UNDERSIDE OF THE ROOF SHEATHING CLEAR OF INSULATION. ENERGY OR RAISED HEEL TRUSSES WITH ADEQUATE VENTILATION CLEARANCE BETWEEN THE TOP OF BATT TO THE UNDERSIDE OF ROOF SHEATHING MAY OMIT BAFFLES. 23. MOISTURE BARRIERS INSTALLED BENEATH SIDING OVER EXTERIOR WALL SHEATHING (HOUSE WRAP) SHALL HAVE LAPPED AND TAPED SEAMS COVERING THE ENTIRE SHEATHED WALL SURFACE. UPPER SEGMENTS OF WRAP SHALL LAP OVER LOWER LEVELS TO ALLOW MIGRATION OF WATER DOWNWARD OVER SEAMS. 24, A MINIMUM OF 90% OF ALL LIGHT BULBS SHALL BE ENERGY SAVING TYPE. 25. LATERAL LOAD RESISTING SYSTEM FOR THE STRUCTURE HAS BEEN DESIGNED USING THE SIMPLIFIED WALL BRACING PROVISIONS OF THE 2020 RESIDENTIAL BUILDING CODE SECTION R602.12. 26. THE NOTES, SECTIONS, AND DETAILS ON THESE DRAWINGS ARE TYPICAL UNLESS OTHERWISE INDICATED. SIMILAR REFERENCES AND DETAILS OR REQUIREMENTS APPLY TO SIMILAR CONDITIONS. REVIEWED FOR ENERGY CODE COMPLIANCE - 21'-0" - 12 8 8:12 0F__ RONT ELEVATION - _ 12 R� REAR a TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, Compliance with our comments shall not be construed as indicating the plans and speci icatians are in 2 full Compliance wiih the Building Codes of o - New York State. NOTICE KRAFT PAPER INSULATION MUST BE COVERED BY NON-COMBUSTIBLE BARRIER NOTICE FOAM INSULATION MUST BE COVERED BY 15 MINUTE THERMAL BARRIER NOTICE: Smoke detectors are required in bedrooms, adjacent to bedrooms and on each floor level including cellar or basement. All smoke detectors $ carbon monoxide detectors shall be Interconnnected with battery backup and located on all levels. Carbon monoxide detecto are repqair� outside sleeping areas and on all Idvels. TABLE R301.2 (1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW WIND DESIGN SEISMIC DESIGN CATEGORY SUBJECT TO DAMAGE FROM WINTER DESIGN ICE BARRIER UNDERLAYMENT FLOOD HAZARDS AIR FREEZING MEAN ANNUAL CLIMATE ZONE SPEED TOPOGRAPHIC SPECIAL WIND WIND-BORNE WEATHERING FROST LINE TERMITE LOAD a (mph) EFFECTS k REGION DEBRIS ZONE m f a DEPTH b TEMP e REQUIRED h e INDEX TEMPI 50 115 NO NO NO B SEVERE 4 FT SLIGHT -MOD 0° F YES NO 2500 45.2° F 6A FOR SI: 1 POUND PER SQUARE FOOT = 0.0479 kPa, 1 MILE PER HOUR = 0.447m/s NOTES: a. WEATHERING MAY REQUIRE A HIGHER STRENGTH CONCRETE OR GRADE OF MASONRY THAN NECESSARY TO SATISFY THE STRUCTURAL REQUIREMENTS OF THIS CODE. THE WEATHERING COLUMN SHALL BE FILLED IN WITH THE WEATHERING INDEX, "NEGLIGIBLE," "MODERATE" OR "SEVERE" FOR CONCRETE AS DETERMINED FROM FIGURE R301.2(3). THE GRADE OF MASONRY UNITS SHALL BE DETERMINED FROM ASTM C 34, C 55, C 62, C 73, C90, C 129, C 145, C 216 OR C 652. b. THE FROST LINE DEPTH MAY REQUIRE DEEPER FOOTINGS THAN INDICATED IN FIGURE R403.1(1). THE JURISDICTION SHALL FILL IN THE FROST LINE DEPTH COLUMN WITH THE MINIMUM DEPTH OF FOOTING BELOW FINISH GRADE. c. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE TO INDICATE THE NEED FOR PROTECTION DEPENDING ON WHETHER THERE HAS BEEN A HISTORY OF LOCAL SUBTERRANEAN TERMITE DAMAGE. d. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE WIND SPEED FROM THE BASIC WIND SPEED MAP [=IGURE R301.2(4)A]. WIND EXPOSURE CATEGORY SHALL BE DETERMINED ON A SITE -SPECIFIC BASIS IN ACCORDANCE WITH SECTION R301.2.1.4. e. THE OUTDOOR DESIGN DRY-BULB TEMPERATURE SHALL BE SELECTED FROM THE COLUMNS OF 97 1/2-PERCENT VALUES FOR WINTER FROM APPENDIX D OF THE INTERNATIONAL PLUMBING CODE. DEVIATIONS FROM THE APPENDIX D TEMPERATURES SHALL BE PERMITTED TO REFLECT LOCAL CLIMATES OR LOCAL WEATHER EXPERIENCE AS DETERMINED BY THE BUILDING OFFICIAL. f. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE SEISMIC DESIGN CATEGORY DETERMINED FROM SECTION R301.2.2.1. g. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH (A) THE DATE OF THE JURISDICTION'S ENTRY INTO THE NATIONAL FLOOD INSURANCE PROGRAM (DATE OF ADOPTION OF THE FIRST CODE OF ORDINANCE FOR MANAGEMENT OF FLOOD HAZARD AREAS), (B) THE DATE(S) OF THE FLOOD INSURANCE STUDY AND (C) THE PANEL NUMBERS AND DATES OF THE CURRENTLY EFFECTIVE FIRMS AND FBFMs OR OTHER FLOOD HAZARD MAP ADOPTED BY THE AUTHORITY HAVING JURISDICTION, AS AMENDED. h. IN ACCORDANCE WITH SECTIONS R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 AND R905.8.3.1, WHERE THERE HAS BEEN A HISTORY OF LOCAL DAMAGE FROM THE EFFECTS OF ICE DAMMING, THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "YES." OTHERWISE, THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "NO". i. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE 100-YEAR RETURN PERIOD AIR FREEZING INDEX (BF -DAYS) FROM FIGURE R403.3(2) OR FROM THE 100-YEAR (99 PERCENT) VALUE ON THE NATIONAL CLIMATIC DATA CENTER DATA TABLE "AIR FREEZING INDEX -USA METHOD (BASE 37F)." j. THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH THE MEAN ANNUAL TEMPERATURE FROM THE NATIONAL CLIMATIC DATA CENTER DATA TABLE "AIR FREEZING INDEX -USA METHOD (BASE 32° F)." k. IN ACCORDANCE WITH SECTION R301.2.1.5, WHERE THERE IS LOCAL HISTORICAL DATA DOCUMENTING STRUCTURAL DAMAGE TO BUILDINGS DUE TO TOPOGRAPHIC SIND SPEED-UP EFFECTS, THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "YES". OTHERWISE, THE JURISDICTION SHALL INDICATE "NO" IN THIS PART OF THE TABLE. I. IN ACCORDANCE WITH FIGURE R301.2(4)A, WHERE THERE IS LOCAL HISTORICAL DATA DOCUMENTING UNUSUAL WIND CONDITIONS, THE JURISDICTION SHALL FILL IN THIS PART OF THE TABLE WITH "YES" AND IDENTIFY ANY SPECIFIC REQUIREMENTS. OTHERWISE, THE JURISDICTION SHALL INDICATE "NO" IN THIS PART OF THE TABLE. m. IN ACCORDANCE WITH SECTION R301.2.1.2.1, THE JURISDICTION SHALL INDICATE THE WIND-BORNE DEBRIS WIND ZONE(S). OTHERWISE, THE JURISDICTION SHALL INDICATE "NO" IN THIS PART OF THE TABLE. THERMAL ENVELOPE LOCATION MAX U-FACTOR MIN R-VALUE LOCATION MAX U-FACTOR MIN R-VALUE WINDOWS (LOW E) 0.30 NA FIRE DOOR 0.14 NA 15-LITE SLIDERS & PATIO DOORS 0.30 NA UNFINISHED BASEMENT NA 19 (CONTINUOUS) CEILINGS NA 38 (FRMG CAVITY) BASEMENT EGRESS WINDOW 0.29 NA EXTERIOR WALLS NA 21 (STUD CAVITY) TYPICAL EXTERIOR DOOR 0.24 NA BASEMENT SASH 0.40 NA THERMAL ENVELOPE NOTES: 1. THE THERMAL ENVELOPE COMPLIANCE METHOD USED FOR DESIGN PURPOSES HAS BEEN COMPLETED IN ACCORDANCE WITH CODE SECTION N1102.1.5 USING THE TOTAL UA ALTERNATIVE (SEE ATTACHED RESCHECK CERTIFICATE FOR MORE INFORMATION AND CALCULATIONS). 2. EACH COMPONENT SHALL MEET OR EXCEED THE THERMAL VALUE(S) SPECIFIED ABOVE OR SHALL ALTERNATIVELY MEET THE PRESCRIPTIVE INSULATION AND FENESTRATION REQUIREMENTS OF TABLE N1102.1.2 (R402.1.2). 3. WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NOT GREATER THAN 0.3 CFM PER SQUARE FOOT, AND FOR SWINGING DOORS, NOT GREATER THAN 0.5 CFM PER SQUARE FOOT, WHEN TESTED IN ACCORDANCE WITH NFRC 400 OR AAMANVDMA/CSA 101/I.S.2/A440. 8:12 I- =12= BASEMENT EGRESS WINDOW - AND ENCLOSURE/ESCAPE WELL. SEE NOTES ON FDN PLAN AND DETAILS FOR MORE INFO OLEFT ELEVATION RIGHT ELEVATION =8:12= 301.18-2-59 2024-0369 Cerrone Builders 54 Dean Thomas Way, lot 16 SFD w/unfinished basement, gas fp 1677 s.f. 3-car attached garage 750 s.f. DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY CALL BEFORE YOU DIG WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ELE COPY TOWN OF QUEENSBUF FIRE MARSHAL'S OFFI( REVIEWE�Y DATE ` T _ COMMENTS, eu rem ENGINEERS STAMP: 7/18/24 REVISIONS 5 4 3 w a } J W Q 2 7/18/24 REVISED FRONT GABLE 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED a DATE: 6/19/24 Z W co o DRAWN BY: DWRPE U Z PROJECT: CERRONE BUILDERS INC LU LOT 16 VUS j QUEENSBURY, NY W� U = D 0w a a DRAWING TITLE GENERAL NOTES & W a BUILDING ELEVATIONS QZ W IL . o§ U J UJ W m Z DRAWING NO. T DWG=l z J 2 J Q N Z O g= OF 7 a W } N a �o I CV N O N � �I 0 i� .m 7'-0" 14'-0" 11'-D" 28'-0" 5-6" 5'-6" 5-0" 6-10 1 /8" 10'-4 1/2" V-11 1 /8" V-11 1 /8" O I (3) 2X10 DROPPED - M NOTIC PORCH BEAM AT N GAS BURNING DIRECT VENT PERIMETER FIREPLACE, COORD. STYLE Install per manuf AND FINISH WITH BUI DER COVERED PORCH NOOK PRIOR TO CONST. INSTALL PER MANUF. SPECIFICATIONS Specs and (CONCRETE FLOOR) A o :15-LITE � � M plan rev 30 DOm TEMP. �� *R.O. HT INCREASED FAN FOR TRANSOM O 13-8 1/2" 10'-1' 13'-7 1/2" 23'-8 1/2" o � BATH 2 W.I.C. 3-2X12 HDR C4 LLL cfl 6 2 _ 6 2 BEDROOM #1 �^ KITCHEN �� TOP PUNDELATE FAMILY ROOM L13 - AT FP OPNG rJ L NOTE: KITCHEN LAYOUT T-7" 6'-2 1/2" BSMNT SHOWN IS EGRESS • o SCHEMATIC ONLY - BELOW SMOKE MIN. 22X30 2a o COORDINATE FINAL LAYOUT WITH ALARM ATTIC ® BUILDER PRIOR TO BEDROOM #2 ACCESS CONSTRUCTION - I - o 26 r -1 r N SMOKE iv ALARM U) 2e 2a L - J 26 26 FAN® C.O. o z DET. , �5 5'-4 3/4" 5'-4 3/4" BATH 1 Q 4.4 ct) ® L-C,)) SMOKE[1 PANTRY 3'-7" -- P-ANTRY - SLOPED FAR N LIVING ROOM DET. bo T_' ALARM SMOKE - TEMP. BASEMENT STAIR ALARM N „ 9'-8 1/2" 8'-2 1 /2 `� 13 R AT 7.96" t 12T AT 9" t 20 20 20 20 6'-4" MUD ENTRY r ROOM o `' ALMARM - - a 2 c� r 3'-7" co iO 2a I � � 30 o `- "' W.I.C. o 4 18'-4" DEN 2a -1" r I j 9-LITE M �20 1--, __ _ _. __W .._ ��� �� - 2' BARN DR 9-LITE I; B COVERED BUILT-UP STUD r- N PORCH b COLUMNS AT 28 io POINT LOADS 0 12'-1" 28 "` co (CONC. FLOOR) (TYPICAL) 1/2" GYPSUM WALL BOARD `' FIRE 611" co ON GARAGE WALLS COMMON I WITH DWELLING (3) 2X10 - -- g 1 0, 17'-0" 13'-0" DROPPED PORCH 28SELF-CLOSING BEAM AT HEAT 20-MIN 0 FIRE RATED PERIMETER DET. DOOR ASSEMBLY CODE REQUIRED Cn F_ 0 FIRE RATED SEPARATION 0 m INSTALL 1/2'' GYPSUM WALL m BOARD ON GARAGE CEILING z z 3-CAR GARAGE C2 x � O OO GARAGE PORTAL FRAME (SEE DETAIL) WITH (2) 1.75 x 11 7/8" LVL OH DOOR HDR (CCNT. SPAN) °°O H. DOOR 16 X 7 8°X 7� O.H. DOOR _ 10'-0" 14'-0" 6-0" 6-0" 9'-1 3/8" 2'-10 5/8" 6'-0" 6-0" 30'-C 18'-0" 12-0" 60'-0" FIRST FLOOR PLAN 1/4"=1'-0" TOTAL LIVING SPACE=1677t S.F. icturer's ,ee lew *R.O. HT INCREASED FOR TRANSOM c? zo w FLOOR PLAN NOTES: 1. ALL EXTERIOR WALLS ARE 2X6, UNLESS NOTED OTHERWISE. ALL INTERIOR WALLS ARE 2X4, UNLESS NOTED OTHERWISE. USE PRE-CUT WALL STUDS WITH A CONTINUOUS DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE FOR A FIRST FLOOR CEILING HEIGHT OF 9'-1 1/8", UNLESS OTHERWISE NOTED. 2. GARAGE EXTERIOR WALLS ARE 2X4, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR DOORS SHALL BE PRE -HUNG DOORS WITH SIZES AS SPECIFIED ON THE FLOOR PLAN. VERIFY THE STYLE AND FINISH FOR ALL DOORS WITH THE BUILDER & OWNER PRIOR TO CONSTRUCTION. 4. WALL DIMENSIONS INDICATED ARE TO FACE OF STUD, UNLESS NOTED OTHERWISE. 5. INSTALL WATER CLOSETS, LAVATORIES, AND SHOWERS WITH CLEARANCES AS INDICATED IN TABLE ON DRAWING #7. 6. EACH BATHROOM EXHAUST FAN MUST BE VENTED DIRECTLY TO THE EXTERIOR. COORDINATE THE EXHAUST VENT DISCHARGE LOCATIONS IN THE FIELD WITH THE BUILDER & OWNER PRIOR TO CONSTRUCTION. 7. WHERE FLOOR JOISTS ARE PARALLEL WITH EXTERIOR BEARING WALLS, INSTALL SOLID FULL HEIGHT 2X WOOD BLOCKING AT 36" O.C. INTERVALS ALONG PARALLEL WALL LENGTH IN FIRST BAY ADJACENT TO RIM JOIST. SEE SECTIONS AND DETAILS FOR MORE INFORMATION. 8. INSTALL DOUBLE FLOOR JOISTS AT 16" OC WHERE TUBS AND PARALLEL PARTITION WALLS OCCUR ABOVE. 9. AT EXTERIOR EXITS IF SITE GRADING REQUIRES MORE THAN ONE TREAD TO GRADE, INSTALL LANDING (UNLESS AT PORCH), TREATED STAIR, GUARDS, AND HANDRAIL PER CODE. SEE STAIR NOTES ON DRAWING #7 FOR MORE INFORMATION. 10. CONTRACTOR TO INSTALL ATTIC ACCESS IN ACCORDANCE WITH CODE REQUIREMENTS. COORDINATION LOCATION IN FIELD WITH OWNER & BUILDER. MINIMUM ATTIC OPENING SHALL BE 22"X30" AND THE PERIMETER SHALL BE SEALED WITH A COMPRESSIBLE GASKET WITH FULL INSULATION DEPTH OVER THE ACCESS DOOR. 11. SEE GENERAL NOTES ON DRAWINGS #1 & #7 AND WOOD FRAMING NOTES ON DRAWING #3 FOR ADDITIONAL REQUIREMENTS AND INFORMATION. 12, RANGE EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE AUTOMATICALLY CONTROLLED TO START AND OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. 13. GARAGES SHALL BE PROVIDED WITH A HEAT DETECTION DEVICE RATED FOR THE OUTDOOR AMBIENT TEMPERATURE AND WITH BATTERY BACKUP INTERCONNECTED WITH THE SMOKE OR FIRE ALARM SYSTEM (DEVICE SHALL BE UL521 OR UL539). 14, EXTERIOR PORCH COLUMNS SHALL HAVE A MINIMUM P.T. 6X6 CORE, UNLESS OTHERWISE NOTED. INSTALL POSTS FLUSH TO EXTERIOR FACE OF SUPPORTED BEAMS AND ANCHOR EACH POST TO BEAMS WITH SIMPSON AC6 OR ACE6 OR SIMILAR CONNECTORS. POST BASES SHALL BE ANCHORED TO SUPPORTING SURFACES WITH A SIMPSON ABW66 OR SIMILAR POST BASE. VERIFY AND COORDINATE COLUMN STYLES AND FINISHES WITH BUILDER AND OWNER PRIOR TO CONSTRUCTION. 15. FIREPLACES, WHEN SHOWN, SHALL BE GAS BURNING DIRECT VENT AND/OR ZERO CLEARANCE PREFABRICATED INSERTS/UNITS WITH A FLUE/EXHAUST PER CODE TO THE EXTERIOR IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION REQUIREMENTS/SPECIFICATIONS. MAINTAIN PROPER CLEARANCES FOR INSTALLATION OF ADJACENT/SURROUNDING FRAMING AND FINISHES. VERIFY AND COORDINATE THE LOCATION, SIZE, STYLE, AND FINISHES OF THE FIREPLACE AND RELATED COMPONENTS WITH THE BUILDER AND OWNER PRIOR TO CONSTRUCTION. 16. CABINETS, APPLIANCES, ISLANDS, FIXTURES, CLOSETS, SHELVING, BUILT-INS, AND SIMILAR FINISHES AND/OR COMPONENTS ARE SCHEMATIC ONLY. VERIFY AND COORDINATE PROJECT REQUIREMENTS FOR THESE ITEMS WITH THE BUILDING AND OWNER PRIOR TO CONSTRUCTION. 17, WINDOWS AND EXTERIOR DOORS SHALL BE OF MANUFACTURE, STYLE, AND FINISH PER THE BUILDER'S AND OWNER'S PROJECT SPECIFICATIONS. VERIFY AND COORDINATE REQUIREMENTS WITH THE BUILDER AND OWNER PRIOR TO START OF CONSTRUCTION. THERMAL PERFORMANCE OF WINDOWS AND EXTERIOR DOORS SHALL MEET THE MINIMUM PERFORMANCE REQUIREMENTS SPECIFIED ON THE THERMAL ENVELOPE TABLE ON DRAWING #1. 18. REFER TO DRAWING #3 FOR ROOF PLAN, WINDOW SCHEDULE, THE TYPICAL BUILDING SECTION, AND RELATED INFORMATION. NATURAL LIGHT & VENTILATION NOTES 1. ALL HABITABLE ROOMS HAVE BEEN PROVIDED WITH NATURAL LIGHT TO INCLUDE AN AGGREGATE GLAZING AREA OF NOT LESS THAN 8 PERCENT OF THE FLOOR AREA OF SUCH ROOMS, UNLESS OTHERWISE NOTED. 2. FOR ROOMS WHICH REQUIRE ARTIFICIAL LIGHT (REFER TO TABLE BELOW), PROVIDE ADEQUATE LIGHTING/ILLUMINATION THAT PROVIDES A MINIMUM OF 6 FOOTCANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL, 3. ALL HABITABLE ROOMS HAVE BEEN PROVIDED WITH VENTILATION TO INCLUDE AN AGGREGATE AREA OF NOT LESS THAN 4 PERCENT OF THE FLOOR AREA OF SUCH ROOMS, UNLESS OTHERWISE NOTED. 4. ROOM VENTILATION SHALL BE THROUGH WINDOWS, DOORS, LOUVERS, OR OTHER APPROVED OPENINGS TO THE OUTSIDE AIR, SUCH OPENINGS SHALL BE PROVIDED WITH READY ACCESS OR SHALL OTHERWISE BE READILY CONTROLLABLE BY THE BUILDING OCCUPANTS. 5. ALTERNATIVELY, GLAZED AREAS WITHIN HABITABLE ROOMS NEED NOT BE OPENABLE WHERE THE OPENING IS NOT REQUIRED BY SECTION R310 AND AN APPROVED MECHANICAL VENTILATION SYSTEM IS PROVIDED CAPABLE OF PRODUCING 0.35 AIR CHANGES PER HOUR IN THE ROOM. 6. FOR THE PURPOSE OF DETERMINING LIGHT AND VENTILATION REQUIREMENTS, ANY ROOM SHALL BE CONSIDERED AS A PORTION OF AN ADJOINING ROOM WHEN AT LEAST ONE-HALF OF THE AREA OF THE COMMON WALL IS OPEN AND UNOBSTRUCTED AND PROVIDES AN OPENING OF NOT LESS THAN ONE -TENTH OF THE FLOOR AREA OF THE iNTERIOR ROOM BUT NOT LESS THAN 25 SQUARE FEET. 7 BATHROOMS, WATER CLOSET COMPARTMENTS, AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SQUARE FEET, ONE HALF OF WHICH MUST BE OPENABLE. 8. THE GLAZED AREAS OF BATHROOMS, WATER CLOSET COMPARTMENTS, OR SIMILAR ROOMS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL b VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 o CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION, N VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 9. WHERE WHOLE HOUSE VENTILATION SYSTEMS ARE INSTALLED THAT MEET THE VENTILATION DEMAND FOR THE ENTIRE THERMAL ENVELOPE IN ACCORDANCE WITH M1505.4, THE GLAZED AREA OF A HABITABLE ROOM NEED NOT BE OPENABLE (R303.1 EXCEPTION 1). 10. HABITABLE ROOMS OR SPACES INCLUDE THOSE AREAS USED FOR LIVING, SLEEPING, EATING, OR COOKING. BATHROOMS, TOILET ROOMS, CLOSETS, HALLS, STORAGE SPACES, UTILITY ROOMS, AND SIMILAR SPACES ARE NOT CONSIDERED HABITABLE SPACES APPLICABLE TO THE REQUIREMENTS OF NATURAL LIGHT AND VENTILATION. CODE REQUIRED NATURAL LIGHTING & VENTILATION CALCULATIONS TABLE (SQ. FT.) ROOM NAME ROOM AREA REQ'D LT. (8%) ACTUAL LT. REQ'D VENT. (4%) ACTUAL VENT. KITCH/NOOK/LIVING 645 51.6 76.2 25.8 38.0 MASTER BEDROOM 165 13.2 16.5 6.6 6.7 BEDROOM #2 165 13.2 16.5 6.6 6.7 MASTER BATH 1 NA NA 112 3.0 4.1 1.5 2.0 FULL BATH 2 3.0 4.1 1.5 2.0 DEN 9.0 24.0 1 4.5 11.6 DAN I E L W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS, DIG SAFELY - CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ENGINEERS STAMP: �OF w r 1 C9 +,0, 07906 ROPES S 1 ONP� 7/18/24 REVISIONS 5 4 3 2 7/18/24 REVISED FRONT GABLE 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED DATE: 6/19/24 DRAWN BY: DWRPE PROJECT: CERRONE BUILDERS INC LOT 16 VUS QUEENSBURY, NY DRAWING TITLE FIRST FLOOR PLAN & PLAN NOTES DRAWING NO. DWG=2 OF 7 w !� 0 Fw �> Ow �Lu �w o� w= U D� o� OJ a 4 w r �w �a Oz Q w>- a O� U ww co z z A J d J d_ N N ZO S a0 Lu `" a Lu° PREFABRICATED ROOF - TRUSSES @ 24" O.C. (TYP.) GABLE END TRUSS TYPICAL MIN. 22X30 OPN. IN - SHEATHING BELOW OVERFRAMING FOR ACCESS/VENTILATION (TYP.) GIRDER TRUSS r------- -fir-=== 8:12 11 8:12 11 rF_ -1 GIRDER TRUSS I _JJ �L= -r - --- �� ICE AND WATER SHIELD EXTEND MIN. 2'-0" BEYOND INSIDE WALL LINE (TYPICAL) X, `� `� ��� ` OVERFRAMED STEPPED ROOF I I I SEE NOTES FOR MORE TRUSSES OR 2X8 RAFTERS @ 8:12 I I INFORMATION GIRDER TRUSS I I (I 8:12 I I I I I I I I II 8:12 24" O.C. AT SHADING TYP CONTINUOUS RIDGE VENT (TYP.) NOTE: TRUSSES WITH THREE ` BEARING POINTS AT 8:12 PORCH/GARAGE IF I I o 8:12 (I II 21'-0" I� 8:12 ROOF PLAN 1/4"=1'-0" 12" (TYP. U.N.O.) 1 FALSE TWIN GABLE, SEE ELEVATION FOR MORE INFO ROOF PLAN NOTES: 1. ROOF UNDERLAYMENT: UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED MINIMUM 2 INCHES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. END LAPS SHALL BE OFFSET BY AT LEAST 6 FEET. 2. ICE PROTECTION: AN ICE BARRIER CONSISTING OF SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET, SHALL BE USED IN PLACE OF UNDERLAYMENT AND EXTEND FROM THE EAVE'S EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. 3, BASE AND CAP FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. BASE AND CAP FLASHING SHALL BE OF CORROSION RESISTANT METAL MINIMUM 0.019-INCH THICKNESS. 4. VALLEYS: CLOSED VALLEYS (COVERED WITH SHINGLES) SHALL BE LINED WITH ONE LAYER OF SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET, THE VALLEY LINING SHALL BE AT LEAST 36 INCHES WIDE. OPEN VALLEYS (VALLEY LINING EXPOSED) SHALL BE LINED WITH CORROSION RESISTANT METAL AND SHALL BE AT LEAST 24 INCHES WIDE. COPPER LININGS SHALL BE MINIMUM 1 LB WT., AND ALUMINUM SHALL BE MINIMUM 0.024-INCH THICKNESS. 5. ALL VERTICAL SIDEWALLS SHALL BE FLASHED WITH METAL AND SHALL BE BY THE STEP -FLASHING METHOD. 6. FOR SLOPES LESS THAN 5 VERT. IN 12 HORIZ. INSTALL UNDERLAYMENT IN THE FOLLOWING MANNER: APPLY A 19-INCH STRIP OF UNDERLAYMENT PARALLEL WITH AND STARTING AT THE EAVES, THEN STARTING AT THE EAVE APPLY 36-INCH WIDE SHEETS, LAPPING SUCCESSIVE SHEETS MINIMUM 19 INCHES. 7. COFFERED OR TREY CEILINGS, WHEN SPECIFIED, SHALL ALLOW FOR A RECESS OR RAISED CEILING HEIGHT AS SPECIFIED AT THE CENTER AREA WITH A FLAT CEILING AT THE PERIMETER OF THE HEIGHT CHANGE (SEE FLOOR PLAN FOR MORE INFORMATION), UNLESS OTHERWISE SHOWN OR SPECIFIED. COORDINATE LOCATIONS, DIMENSIONS, ELEVATIONS, AND PERIMETER OF CEILING HEIGHT CHANGES OR RECESSES WITH BUILDER AND OWNER PRIOR TO CONSTRUCTION. 8. CATHEDRAL CEILINGS, WHEN SPECIFIED ON FLOOR PLANS, SHALL HAVE INTERIOR CEILING SLOPES (BOTTOM CHORD OF TRUSSES) AS SHOWN ON PLANS, SECTIONS, AND DETAILS. 9. THE TRUSS LAYOUT SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. THE TRUSS DESIGN/ENGINEERING IS HEREBY DELEGATED TO OTHERS. THE TRUSS MANUFACTURER AND ENGINEER/DESIGNER SHALL DETERMINE FINAL LAYOUT OF TRUSS FRAMING. CONTRACTOR SHALL REFER TO TRUSS DRAWINGS SUPPLIED BY MANUFACTURER FOR FINAL LAYOUT, DESIGN, AND INSTALLATION INSTRUCTIONS. MINIMUM DESIGN LOADS FOR TRUSSES SHALL BE IN ACCORDANCE WITH CODE REQUIREMENTS FOR THE PROJECT LOCATION, AND AS SPECIFIED IN THE DESIGN LOADS TABLE ON DRAWING #7. 10. CONTRACTOR/BUILDER AND/OR TRUSS MANUFACTURER SHALL COORDINATE AND ADJUST HEEL HEIGHTS OR OVERHANG LENGTHS FOR TRUSSES AND RAFTERS FOR ROOF AREAS WITH VARYING ROOF PITCHES AND AT INFILL AREAS (SUCH AS PORCHES) TO ALIGN THE FASCIA AT THE EXTERIOR PERIMETER OF THE BUILDING FOR EACH ROOF LEVEL. 11. REFER TO TYPICAL DETAILS AND BUILDING SECTIONS FOR ADDITIONAL INFORMATION NOT SHOWN OR SPECIFIED. 12. REFER TO TRUSS NOTES THIS DRAWING FOR ADDITIONAL INFORMATION AND REQUIREMENTS. METAL -PLATE CONNECTED WOOD TRUSS NOTES 1, PRE -FABRICATED ROOF TRUSSES SHALL BE CAPABLE OF SUPPORTING A TOP CHORD ROOF SNOW LOAD OF 38.5 PSF, TOP CHORD DEAD LOAD OF 10 PSF, AND BOTTOM CHORD DEAD LOAD OF 10 PSF. DESIGN TRUSSES FOR BALANCED SNOW LOADS AND UNBALANCED SNOW LOADS (TWO SEPARATE LOAD CASES) IN ADDITION TO DEAD LOADS. MAXIMUM TRUSS DEFLECTION SHALL BE U360 FOR SNOW LOAD AND U240 FOR TOTAL LOAD. CT OF 1.1 IS ASSUMED BASED UPON A COLD VENTILATED ATTIC. USE A CT OF 1.2 FOR UNHEATED SPACES OR BUILDING COMPONENTS (GARAGES AND PORCHES). 2. PRE -FABRICATED ROOF TRUSSES SHALL BE DESIGNED BY A LICENSED PROFESSIONAL ENGINEER. SUBMIT S-AMPED AND SIGNED/SEALED TRUSS DESIGN CALCULATIONS AND LAYOUT/SUBMITTALS/SHOP DRAWINGS PREPARED BY A LICENSED PROFESSIONAL ENGINEER TO THE CODE ENFORCEMENT OFFICER PRIOR TO FABRICATION AND INSTALLATION. 3. COMPLY WITH ANSI/TPI-1"NATIONAL DESIGN SPECIFICATION FOR METAL -PLATE CONNECTED WOOD TRUSS CONSTRUCTION". LATEST EDITION. 4. FABRICATION AND ERECTION OF TRUSSES SHALL BE IN ACCORDANCE WITH QUALITY CONTROL MANUAL OF THE T.P.I. 5. CONTINUOUSLY BRACE TRUSS BOTTOM CHORDS WITH FLAT 2-INCH BY 4-INCH BRACING AT APPROXIMATELY 8 FEET ON CENTER, LOCATED AT OR NEAR PANEL POINTS. PROVIDE DIAGONAL BOTTOM CHORD BRACING BETWEEN HORIZONTAL BRACING FOR FULL WIDTH OF BUILDING AT END NON -BEARING WALLS AND AT 20 FEET ON CENTER THROUGHOUT LENGTH OF BUILDING. PROVIDE CONTINUOUS VERTICAL 2-INCH BY 4-INCH DIAGONAL CROSS BRACING NAILED TO EACH TRUSS DIAGONAL FROM RIDGE TO BOTTOM CHORD OF TRUSS. ONE PAIR OF DIAGONAL CROSS BRACING REQUIRED FOR EACH SIX TRUSSES. FIRMLY SECURE BRACING TO GABLE END WALLS. 6. FURNISH GABLE END TRUSSES WITH VERTICAL 2-INCH BY 4-INCH MINIMUM STUDS AT 24 INCHES ON CENTER. WHERE REQUIRED BY DESIGN (I.E. AT FINISHED SPACES/ATTICS) PROVIDE 2X6 WEB MEMBERS AND/OR MEET REQUIREMENTS FOR THE MINIMUM SIZE WEBS/CHORDS, AS APPLICABLE. 7. TRUSS MANUFACTURER TO DESIGN AND SPECIFY ALL TRUSS CONNECTIONS, BRACING, HANGERS, AND ETC REQIIRED BETWEEN INDICATED TRUSS COMPONENTS. ACCOMMODATE SUBSEQUENT OR SUPPLEMENTAL FRAMING IN THE TRUSS DESIGN/CONFIGURATION AND LAYOUT WHERE FRAMING IS SUPPORTED BY GIRDER TRUSSES OR SIMILAR CONDITIONS IN ACCORDANCE WITH DETAILS AND NOTES (I.E COORDINATE WEB OR CHORD SIZES/DEPTHS/ELEVATIONS FOR INSTALLATION OF JOIST HANGERS OR SIMILAR CONDITIONS AT SUPPORTED STRUCTURE). 8. TRUSSES SHALL BE DESIGNED WITH A PINNED SUPPORT AT ONE END AND A ROLLER SUPPORT AT THE OPPOSITE AND SUCH THAT A ZERO HORIZONTAL FORCE RESULTS. 9. TRUSS MANUFACTURER SHALL DETERMINE TRUSS CONFIGURATIONS, SIZES, NUMBER OF PLY'S, AND SPACING TO MEET THE SPECIFIED LOADS, INSTALLATION CONDITIONS AND SPATIAL CONSTRAINTS, ELEVATIONS, SLOPES, AND ETC. SHOWN ON THE DRAWINGS, PLANS, AND DETAILS. 10. GIRDER TRUSSES SUPPORTED AT WALLS SHALL HAVE SOLID BUILT-UP STUD COLUMNS BELOW EACH BEARING PCINT. THE MINIMUM SIZE/WIDTH (# OF 2X STUD PLIES) FOR GIRDER TRUSS COLUMNS SHALL BE EQUAL TO THE SIZE OF THE SUPPORTED TRUSS BEARING WIDTH (# OF TRUSS PLIES) PLUS ONE ADDITIONAL STUD. CONNECT EACH GIRDER TRUSS BEARING LOCATION TO THE SUPPORTING WALL PLATE WITH A SIMPSON TBE(4 OR 6) BEARING K�0� E AH C H SIDE OF THE GIRDER TRUSS (MANUFACTURER SHALL NOTIFY THE ENGINEER IF THE GIRDER TRUSS UPLIFT LOADING EXCEEDS 850 LBS CONK RSD�. FULL HT. CONTINUOUS - PERIMETER FSK FACED BATT INSULATION OR FRAMED PERIMETER WITH INSULATION AND POLY V.B. AT FINISHED BASEMENTS (SEE FDN PLAN FOR INFORMATION) 4 INCH CONCRETE SLAB ON GRADE #2 CRUSHED STONE OR SAND/GRAVELSUBBASE AND 6 MIL. VAPOR BARRIER REFER TO TYP DETAIL FOR MORE INFORMATION 8" FDN WALL TYPICAL ROOF CONSTRUCTION - ASPHALT ROOF SHINGLES - 15# BUILDING PAPER - 1/2 INCH APA ROOF SHEATHING - ENERGY TRUSSES AT 24" OC W/H1 CLIP AND RAISED HEEL (OR RAFTERS PER PLAN) - SNOW AND ICE SHIELD AT PERIMETER EXTEND 24 INCHES INSIDE EXTERIOR WALL LINE ALUMINUM DRIP EDGE (INSTALL UNDER ICE & WATER MEMBRANE), AND TRIM 2X6 SUB -FASCIA AND FASCIA VENTED SOFFIT TYPICAL WALL CONSTRUCTION - EXTERIOR SIDING AND TRIM - TYVEK HOUSE WRAP - 1/2 INCH APA WALL SHEATHING - 2X6 STUDS AT 16 INCHES O.C. - 6 INCHES FIBERGLASS BATT INSULATION (MIN. R-21 U.N.O.) - 4 MIL. POLYEHTYLENE VAPOR BARRIER - 1/2 INCH GYPSUM WALL BOARD BOTTOM PLATE (TYPICAL) RIM JOIST (TYPICAL) 6 INCHES FIBERGLASS BATT INSULATION (MIN. R-21) (TYPICAL AT RIM JOIST) PERIMETER EXTERIOR GRADE, DROP GRADE MINIMUM 6" IN FIRST 10'-0" (TYPICAL AT PERIMETER) COORDINATE WITH SITE CONDITIONS FOUNDATION DAMPPROOFING BELOW GRADE CONCRETE FOUNDATION WALL (SEE TYPICAL FDN WALL DETAIL FOR INFORMATION) NOTE: PERIMETER FOUNDATION DRAINAGE NOT SHOWN, COORDINATE WITH FIELD VERIFIED SITE CONDITIONS (BY OTHERS) AND FOUNDATION PLAN/DETAILS FREE DRAINING SAND/GRAVEL BACKFILL UNDISTURBED BEARING SUBGRADE TYPICAL 1-STORY BUILDING SECTION NOT TO SCALE WINDOW & PATIO DOOR SCHEDULE DESIGNATION MODEL # ROUGH OPENING (WxH) GLASS/VISIBLE LIGHT CLEAR OPNGNENT AREA REMARKS OO W30410 3'-2" X S-1 1/2" 12.0 FT2 5.8 FT2 DOUBLE HUNG OW30410-2 6-2 1/4" X 5-1 1/2'' 24.0 FT2 11.6 FT2 TWIN DOUBLE HUNG OW20210 2'-2" X 3-1 1/2" 4.1 FT2 2.0 FT2 DOUBLE HUNG I D I W20510 2'-2" X 6-1 1/2" 9.3 FT2 4.5 FT2 DOUBLE HUNG OW364 3'-8" X 6'-1 1/2' 16.5 FT2 6.7 FT2 TRANSOM/DOUBLE HUNG 0 WINDOW SCHEDULE NOTES: 1. ALL WINDOWS SHALL BE MANUFACTURED BY HARVEY WINDOWS & DOORS, VINYL DOUBLE HUNG UNLESS OTHERWISE SPECIFIED, WITH LOW E. VERIFY FINISHES AND OPTIONAL FEATURES WITH BUILDER AND OWNER PRIOR TO CONSTRUCTION. PROVIDE INSECT SCREENS AT ALL OPERATING UNITS. 2. REFER TO DRAWING #2 FOR NATURAL LIGHT AND VENTILATION CALCULATIONS FOR OCCUPIED ROOMS AND SPACES. 3. Q INDICATES UNIT COMPLIES WITH 5.0 SQ. FT. EGRESS REQUIREMENTS FOR GRADE FLOOR OPENINGS. 4. Q INDICATES UNIT COMPLIES WITH 5.7 SQ. FT. EGRESS REQUIREMENTS FOR ALL OPENINGS. 5. ALL MULTIPLE -UNIT WINDOWS SHALL BE FACTORY MULLED, UNLESS NOTED OTHERWISE. VERIFY MULTIPLE UNIT REQUIREMENTS AND SPECIFICATIONS WITH MANUFACTURER PRIOR TO CONSTRUCTION. 6. CONTRACTOR/BUILDER SHALL VERIFY ALL WINDOW SPECIFICATIONS, ROUGH OPENINGS, AND AVAILABILITY WITH MANUFACTURER PRIOR TO CONSTRUCTION. 7. EXTERIOR SLIDING DOORS SHALL BE VINYL PATIO DOORS AS MANUFACTURED BY HARVEY, UNLESS OTHERWISE NOTED ON FLOOR PLAN. MATCH FINISH WITH WINDOWS AND VERIFY OPTIONAL FEATURES WITH BUILDER/OWNER PRIOR TO CONSTRUCTION. 8. ALL WINDOWS ROUGH OPENINGS SHALL BE PLACED AT 6-11 3/8 ABOVE SUB -FLOOR, UNLESS OTHERWISE NOTED. FOR DH WINDOWS WITH TRANSOMS, SET TOP OF DH WINDOW AT STD HEIGHT WITH TRANSOM ABOVE (ADD HEIGHT OF TRANSOM TO SPECIFIED TYPICAL TOP OF WINDOW R.O.). 9. ALL WINDOWS MUST BE INSTALLED WITH A CHILD SAFETY LOCKING MECHANISM PREVENTING THE WINDOW FROM OPENING MORE THAN 4-INCHES WHEN THE SILL IS LESS THAN 24-INCHES ABOVE THE FLOOR AND/OR THE SILL IS GREATER THAN 72-INCHES ABOVE OUTSIDE ADJACENT GRADE. 10, PROVIDE SAFETY GLAZING AT ALL LOCATIONS DEEMED HAZARDOUS IN ACCORDANCE WITH BUILDING CODE REQUIREMENTS. SEE NOTES AND TABLES ON DRAWING #7 FOR ADDITIONAL INFORMATION. :Y COMPLIANCE AND MINIMUM PERFORMANCE CRITERIA/REQUIREMENTS FOR WINDOWS AND 11, REFER TO THERMAL ENVELOPE TABLE ON DRAWING #1 FOR ENERC DOORS. WOOD FRAMING NOTES: 1. ACCURATELY CUT, FIT, AND SOLIDLY FASTEN MEMBERS TO PROVIDE PLUMB, LEVEL, TRUE, AND RIGID WORK. 2. NAILING NOT INDICATED ON DRAWINGS SHALL BE IN ACCORDANCE WITH TABLE R602.3(1), (2), AND (3) "FASTENING SCHEDULES" CONTAINED IN THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE. 3. COMPLY WITH APPLICABLE RECOMMENDATIONS CONTAINED IN APA, DESIGN/CONSTRUCTION GUIDE - RESIDENTIAL AND COMMERCIAL FOR STRUCTURAL WOOD PANELS INDICATED. 4. FOR BOLTED CONNECTIONS, DRILL HOLES %6 INCH LARGER IN DIAMETER THAN THE BOLTS BEING USED. PROVIDE WASHERS AND NUTS UNDER BOLT HEADS IN CONTACT WITH WOOD. 5. PROVIDE SINGLE BOTTOM PLATE AND DOUBLE TOP PLATES FOR LOAD -BEARING WALLS, 2 INCHES THICK BY THE WIDTH OF THE STUDS, UNLESS NOTED OTHERWISE. STAGGER TOP PLATE SPLICES A MINIMUM OF 4 FEET. SPLICE ONLY AT STUD LOCATIONS. 6. INSTALL FRAMED PURLINS, RAFTERS, AND JOISTS WITH CROWN EDGE UP AND SUPPORT ENDS OF EACH MEMBER WITH NOT LESS THAN 1Y2 INCHES OF BEARING ON WOOD OR METAL OR 3 INCHES ON MASONRY OR CONCRETE. 7. PURLINS, RAFTERS, AND JOISTS SHALL BE SUPPORTED LATERALLY AT THE ENDS AND AT EACH BEARING POINT/SUPPORT WITH 2-INCHES-BY-FULL-DEPTH SOLID BLOCKING (UNLESS DETAILED OTHERWISE) EXCEPT WHERE THE ENDS ARE ANCHORED TO A BEAM, HEADER, BAND JOIST OR ARE HELD IN POSITION BY METAL CONNECTORS AND/OR HANGERS PROVIDING ATERAL RESTRAINT. 8. JOISTS EXCEEDING NOMINAL 2 BY 12 SHALL BE SUPPORTED LATERALLY WITH SOLID BLOCKING CR DIAGONAL BRIDGING AT INTERVALS NOT EXCEEDING 8 FEET. 9. LAP OVER -FRAMED JOISTS SPANNING FROM OPPOSITE SIDES OF DROPPED BEAMS, GIRDERS, OR LOAD BEARING WALLS NOT LESS THAN 4 INCHES OR SECURELY TIE OPPOSING MEMBERS TOGETHER. INSTALL 2 INCHES BY FULL -DEPTH SOLID BLOCKING BETWEEN LAPPED MEMBERS ABOVE EACH BOTTOM BEARING SUPPORT CONDITION 10. DO NOT NOTCH HORIZONTALLY SPANNING SOLID WOOD PURLINS, RAFTERS, AND JOISTS IN THE MIDDLE THIRD OF THE SPAN. LIMIT NOTCHES ON THE TOP OR BOTTOM FACE OF THE MEMBER TO A MAXIMUM DEPTH OF Y6 OF THE DEPTH OF THE MEMBER AND MAXIMUM LENGTH OFY3 OF THE DEPTH OF THE MEMBER. NO OVER -CUTS WILL BE PERMITTED. 11. DO NOT BORE HOLES CLOSER THAN 2 INCHES FROM TOP OR BOTTOM OF SOLID WOOD MEMBERS. LIMIT DIAMETER OF HOLES TO Y THE DEPTH OF SOLID WOOD MEMBERS. 12. USE PRESSURE -TREATED WOOD FOR ELEMENTS EXPOSED TO WEATHER; IN CONTACT WITH SOIL, WATER, MASONRY, CONCRETE; OR FOR WOOD DIRECTLY ABOVE SOIL WHEN THE BOTTOM ELEVATION IS LESS THAN 18 INCHES ABOVE SOIL AND FOR WOOD BEAMS WHEN THE BOTTOM ELEVATION IS LESS THAN 12 INCHES ABOVE SOIL. 13. SIMPSON STRONG -TIE FRAMING CONNECTORS ARE INDICATED ON THE DRAWINGS. EQUIVALENT CONNECTORS WITH EQUAL CAPACITIES FROM OTHER MANUFACTURERS MAY BE UTILIZED. 14. PROVIDE G185 HOT -DIPPED GALVANIZED COATING MEETING THE REQUIREMENTS OF ASTM A 653 FOR METAL FRAMING CONNECTORS IN CONTACT WITH PRESSURE TREATED LUMBER. FASTENERS USED WITH THESE CONNECTORS SHALL BE HOT DIPPED GALVANIZED TO COMPLY WITH ASTM A 153. ALL CONNECTORS SHALL HAVE A Z-MAX FINISH BY SIMPSON STRONG -TIE OR ACCEPTED EQUIVALENT. 15. INSTALL ROOF SHEATHING WITH FACE GRAIN ACROSS SUPPORTS, USING PANELS CONTINUOUS OVER TWO OR MORE SPANS WITH END JOINTS BETWEEN PANELS STAGGERED AND LOCATED OVER CENTER OF SUPPORTS. INSTALL H-CLIPS OR EDGE BLOCKING WHEN REQUIRED BY MANUFACTURER FOR GIVEN APPLICATION AND USE AND WHEN SUPPORTS EXCEED 32" OC SPACING. 16. UNLESS INDICATED OTHERWISE, DO NOT INTERRUPT ROOF SHEATHING WHERE OVER -FRAMED CONDITIONS OCCUR (I.E. WHERE ROOF FRAMING SUPPORTS VALLEY FRAMING). MAINTAIN CONTINUITY OF ROOF DIAPHRAGM UNDER OVER -FRAMED CONDITIONS. INSTALL ADEQUATE VENTILATION AND INSPECTIONS OPENINGS IN LOWER SHEATHING UNDER THE OVER -FRAMED ROOF FOR ACCESS AND VENTILATION. 17. NAIL ROOF SHEATHING TO SUPPORTING ROOF STRUCTURE WITH 8D (2 1/2X0.131) COMMON NAILS AT 6 INCHES ON CENTER ALONG PANEL ENDS AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. NAIL ALL BLOCKED PANEL EDGES OR FIELD FRAMING/INFILL MEMBERS 6 INCHES ON CENTER UNLESS OTHERWISE NOTED. 18. NAIL WALL SHEATHING TO SUPPORTING WALL STRUCTURE WITH 8D (2 1/2X0.131) COMMON NAILS AT 6 INCHES ON CENTER ALONG PANEL ENDS AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE (SPECIAL NAILING AT DESIGNATED SHEAR WALLS OR PORTAL FRAMES MAY BE REQUIRED), 19. GLUE & SCREW FLOOR SHEATHING TO SUPPORTING JOISTS/FRAMING WITH 8D (2 1/2X0.131) RING SHANK OR COMMON NAILS AT 6 INCHES ON CENTER ALONG PANEL ENDS AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. 20. CONSTRUCT HEADERS WITH CONTINUOUS PLYWOOD OR RIGID INSULATION FILLERS OR SPACER BLOCKS AS REQUIRED TO MATCH WALL WIDTH. LOCATED SPACER BLOCKS AT EACH END AND AT MID -SPAN OF HEADER. COORDINATE ALL RELATED WORK AND DETAILS WITH FINISHES. 21. CONSTRUCT HEADERS FROM LUMBER WITHOUT END SPLITS, CHECKS, OR SHAKES. 22. NAIL EACH SIDE OF 2X HEADERS AND BEAMS UP TO 3-PLY AND LVL UP TO 2-PLY WITH (3) 10D AT 12" OC FOR ENTIRE LENGTH. MULTI -PLY LVL BEAMS WITH MORE THAN TWO MEMBERS SHALL BE BOLTED WITH (2) 1/2"0 THRU-BOLTS AT 24" OC. LOCATE ROWS OF NAILING MAXIMUM 2INCHES FROM TOP AND BOTTOM FACES AND AT MID -DEPTH OF BEAM. BOLT ALL BEAMS HAVING THREE OR MORE PLYS WHEN LOAD IS APPLIED TO EITHER OR BOTH SIDES OR VERTICAL FACES OF THE MEMBER. 23. PROVIDE BUILT-UP STUD COLUMNS AT BEAM OR GIRDER BEARING LOCATIONS IN STUD WALLS UNLESS NOTED OTHERWISE. CONSTRUCT BUILT-UP STUD COLUMNS WITH A MINIMUM WIDTH THE SAME WIDTH AS THE BEAM OR GIRDER SUPPORTED. PROVIDE A MINIMUM BEAM OR GIRDER BEARING LENGTH OF 3-INCHES UNLESS OTHERWISE SPECIFIED. 24. CUT "BIRDS MOUTH" IN SLOPED RAFTERS AT EXTERIOR BEARING WALLS TO PROVIDE FULL BEARING ON THE TOP PLATE, 25. PRE -DRILL LEAD HOLES FOR LAG SCREWS WITH A DIAMETER OF 60 PERCENT OF THE SHANK DIAMETER. ENLARGE THE LEAD HOLES TO THE SHANK DIAMETER FOR THE LENGTH OF UNTHREADED SHANK. 26. INSERT LAG SCREWS AND WOOD SCREWS BY TURNING, DO NOT DRIVE WITH HAMMER OR INSTALL WITH HAMMER DRILL. 27. EPDXY ADHESIVE FOR GLUE -NAILED SHEATHING OR BUILT-UP MEMBERS SHALL BE HEAVY DUTY CONSTRUCTION AND SUB -FLOOR ADHESIVE AS MANUFACTURED BY TITEBOND OR ACCEPTED EQUIVALENT. INSTALL EPDXY PER MANUFACTURER'S RECOMMENDATIONS. 28. ROOF RAFTERS AND TRUSSES SHALL BE CONNECTED TO SUPPORTING BEARING WALLS WITH NAILING (PER THE NAILING SCHEDULE CONTAINED IN THE BUILDING CODE) IN ADDITION TO ONE UPLIFT ANCHOR INSTALLED AT EACH SUPPORT OR BEARING POINT. INSTALL SIMPSON H1 HURRICANE TIES OR EQUAL, UNLESS OTHERWISE SPECIFIED. WHERE RAFTERS ARE LAPPED WITH CEILING JOISTS OR SIMILAR CONDITIONS USE SIMPSON H10-2 CONNECTORS TO ATTACH THE DOUBLE/LAPPED MEMBER TO THE SUPPORT. 29. WHERE BEARING WALLS ARE UN -SHEATHED (I.E. INTERIOR BEARING WALLS), INSTALL A CONTINUOUS ROW OF 2X SOLID BLOCKING AT THE MID -HEIGHT OF INTERIOR BEARING WALLS. 30. TYPICAL BEARING WALL HEADERS SHALL BE BUILT-UP (2) 2X10, UNLESS NOTED OTHERWISE. ALL HEADERS GREATER THAN 5'-0" SHALL BE BUILT-UP (3) 2X10 FOR 2X6 WALLS AND (2) 2X12 FOR 2X4 WALLS, UNLESS NOTED OTHERWISE. 31. INSTALL HEADERS AT NON -LOAD BEARING WALL LOCATIONS WITH MINIMUM 1 1/2 INCHES BEARING. 32, INSTALL HEADERS AT LOAD BEARING WALLS WITH MINIMUM 3" BEARING EACH SIDE WHEN THE SPAN IS 5FT OR GREATER. USE MINIMUM 1 1/2" BEARING EACH SIDE WHEN THE SPAN IS UNDER 5FT. WHERE POINT LOADS EXIST OVER HEADERS INSTALL DOUBLE JACK STUDS FOR A MINIMUM OF 3" BEARING EACH END, U.N.O. 33. EACH WALL HEADER JACK STUD SHALL BE ACCOMPANIED BY AN ADJACENT FULL HEIGHT KING STUD OF EQUAL SIZE, JACK STUDS SHALL SHALL BE ATTACHED TO FULL HT KING STUDS NAILED 6" OC STAGGERED. 34. FLUSH FRAMED 2X FLOOR JOISTS AT BEAMS SHALL HAVE SIMPSON U210 16GA FACE MOUNT JOIST HANGERS CONNECTED TO SUPPORTING MEMBER (USE MULTIPLE PLY HANGERS AS REQUIRED, U210-2, U210-3, ETC). 35. WHERE JOISTS, TRUSSES, OR RAFTERS ARE SPACED MORE THAN 16 INCHES ON CENTER AND THE BEARING STUDS DO NOT ALIGN, SUCH MEMBERS SHALL BEAR WITHIN 5 INCHES OF A SUPPORT STUD BELOW UNLESS THE TOP PLATE IS SUPPORTED OR REINFORCED WITH A TRIPLE 2X6 HEADER DIRECTLY BELOW. DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY - CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ENGINEERS STAMP: 7/18/24 REVISIONS w } w o 5 4 3 2 7/18/24 REVISED FRONT GABLE 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED r DATE: 6/19/24 W o DRAWN BY: DWRPE PROJECT: CERRONE BUILDERS INC 5Lu LOT 16 VUS w QUEENSBURY, NY O P U= & as DRAWING TITLE ROOF PLAN & WINDOW w Lu a SCHEDULE o U S Lrn O o DRAWING NO. DWG=3 � a Q N z g= OF 7 a� L� a N' �O Fnl_n,, 0;___ PLAN FOUNDATION PLAN NOTES: 1. REFERENCE ELEVATION (+0'-0") EQUALS TOP OF BASEMENT SLAB ON GRADE. ELEVATIONS NOTED AS (+/- X'-X") ARE WITH RESPECT TO REFERENCE ELEVATION (+0'-0"). 2. PERIMETER FOUNDATION WALLS SHALL BE 8'-T HEIGHT. FOUNDATION WALLS SHALL BE REINFORCED WITH MINIMUM (2) #4 HORIZONTAL REINFORCING AND #4 VERTICAL WHERE SPECIFIED ON THE FOUNDATION PLAN AND DETAILS, REFER TO THE TYPICAL FOUNDATION WALL DETAIL FOR REQUIREMENTS AND RELATED INFORMATION. 3. BOTTOM OF EXTERIOR FROST WALL FOOTINGS (WALK -OUT BASEMENTS, PORCHES, AND GARAGES) SHALL BE MINIMUM 4'-0" BELOW FINISHED GRADE, UNLESS NOTED OTHERWISE. 4. SEE TYPICAL SECTIONS & DETAILS ON THIS DRAWING AND DRAWING #6, AND FOUNDATION NOTES ON DRAWING #7, FOR ADDITIONAL OR RELATED INFORMATION NOT SPECIFIED ON THE FOUNDATION PLAN. 5. ASSUMED BEARING FOR FOUNDATIONS IS ON UNDISTURBED FIRM NATIVE SUBGRADE. WHEN SOILS DO NOT APPEAR TO COINCIDE WITH DESIGN ASSUMPTIONS, ARE EXPANSIVE, OR CONTAIN EXCESSIVE FINES, THE SOIL BEARING STRATUM AND CORRESPONDING FOUNDATION DESIGN AND DETAILS SHALL BE REVIEWED AND VERIFIED BY A QUALIFIED LICENSED PROFESSIONAL ENGINEER OR GEOTECHNICAL ENGINEER BEFORE CASTING CONCRETE. SEE FOUNDATION NOTES FOR ADDITIONAL REQUIREMENTS AND RELATED INFORMATION. 6. COORDINATE UTILITY PENETRATIONS AND UTILITY SERVICE LOCATIONS WITH UTILITY PROVIDERS AND SITE REQUIREMENTS/CONDITIONS. 7. ALL BASEMENT FRAMING DENOTED AS S.P. OR SYP SHALL BE SOUTHERN YELLOW PINE AS SPECIFIED IN THE MATERIALS NOTES ON DRAWING #7. 8. DO NOT BACKFILL BASEMENT FOUNDATION WALLS MORE THAN 4' ABOVE TOP OF FOOTING UNTIL WALLS ARE BRACED BY FLOOR FRAMING WITH SHEATHING INSTALLED OR AFTER INSTALLATION OF TEMPORARY SHORING/BRACING. 9. DROPPED BASEMENT BEAMS SHALL BE SPLICED ONLY OVER THE CENTERLINE OF SUPPORT COLUMNS. 10. COORDINATE SIZE, QUANTITY, AND LOCATIONS OF BASEMENT SASHES AND EGRESS WINDOWS DESIRED BY BUILDER AND/OR OWNER PRIOR TO START OF CONSTRUCTION. 11. FOUNDATION WALL CONTROL JOINTS (WCJ'S) ARE OPTIONAL BUT RECOMMENDED TO CONTROL THERMAL/SHRINKAGE CRACKING IN CAST -IN -PLACE CONCRETE FOUNDATION WALLS. VERTICAL WCJ'S ARE RECOMMENDED AT INTERVALS NOT TO EXCEED 30FT ALONG EACH WALL LENGTH (BETWEEN CORNERS, T-INTERSECTIONS, AND ETC). SEE THE TYPICAL WALL CONTROL JOINT DETAIL FOR MORE INFORMATION. 12, EGRESS WINDOWS SHOWN SHALL BE AS MANUFACTURED BY BOWMAN KEMP. BOWMAN KEMP 4040 EGRESS WINDOWS HAVE A NET CLEAR OPENING AREA OF 7.0 SF WITH 14.1 SF OF NATURAL LIGHT, MINIMUM CLEAR WIDTH OF 21.75", AND MINIMUM HEIGHT OF 45.375". COORDINATE THE HEIGHT OF WINDOW SILL WITH THE FINISHED BASEMENT SLAB ELEVATION TO PROVIDE A MAXIMUM SILL HEIGHT OF 44-INCHES ABOVE THE FINISHED FLOOR. REFER TO THE TYPICAL EGRESS WINDOW DETAIL FOR MORE INFORMATION. 13. THE BASEMENT ELEVATION SHALL BE A MINIMUM OF TWO FEET ABOVE THE FIELD VERIFIED SEASONAL HIGH GROUND WATER (SHGW) ELEVATION. PERIMETER FOUNDATION DRAINAGE IS RECOMMENDED WITH A SUMP PIT AND APPROPRIATE DISCHARGE OUTLET CONDITION WHEN THE SHGW IS DETERMINED TO BE WITHIN FOUR FEET OF THE BASEMENT ELEVATION/SLAB. VERIFY AND COORDINATE THE SHGW ELEVATION WITH FIELD VERIFIED CONDITIONS AT THE TIME OF CONSTRUCTION/EXCAVATION. 14. ANCHOR CONTINUOUS PERIMETER SILL PLATE TO CONCRETE FOUNDATION WALLS WITH 1/2"0 J-HOOKS EMBEDDED IN PLASTIC CONCRETE WITH MINIMUM 9" EMBEDMENT, LOCATE ANCHOR RODS 12 INCHES MAXIMUM FROM EACH END OF SILL PLATE SECTIONS AND 4 FEET MAXIMUM ON CENTER IN BETWEEN (PROVIDE A MINIMUM OF TWO ANCHOR RODS IN EACH SILL PIECE). 15. FOR FINISHED BASEMENT AREAS (OR FUTURE FINISHED SPACES) COORDINATE THE LAYOUT, PLAN ELEMENTS (DOORS, WINDOWS, FIXTURES, AND ETC), AND FINISHES WITH THE BUILDER AND OWNER PRIOR TO CONSTRUCTION. FINISHED BASEMENT AREAS THAT CONTAIN HABITABLE SPACES SHALL COMPLY WITH THE EGRESS, NATURAL LIGHT, AND VENTILATION REQUIREMENTS. WHERE WHOLE HOUSE VENTILATION IS PROVIDED THE FINISHED BASEMENT AREA SHALL BE INCLUDED IN THE SIZING AND CAPACITY OF THE WHOLE HOUSE VENTILATION SYSTEM. 16. WHERE BASEMENT WINDOWS ARE PLANNED INSTALL A DOUBLE RIM JOIST TO SPAN THE FOUNDATION OPENING WHERE BELOW BEARING WALLS OR POINT LOADS FROM ABOVE. EXTEND DOUBLE RIM JOISTS A MINIMUM OF 12-INCHES BEYOND EACH END OF THE FOUNDATION OPENING. (2) #4 HORIZ REINFORCING ABOVE AND BELOW AND EACH SIDE OF C.I.P. BUCK EXTENDED 2FT BEYOND OPNG EACH END BOWMAN KEMP EASY -BUCK BOWMAN KEMP 4040 VINYL EGRESS WINDOW M A[-CII A GAIT (3) 2X10 RIM JOIST OVER OPENING EXTENDED MIN 12'' BEYOND OPNG EDGES WITH U210 JST HANGERS (AT PERP. JOISTS) (2) 2X10 RIM JOIST OVER OPENING EXTENDED MIN 12" BEYOND OPNG EDGES (FOR PARALLEL JSTS) z 21 I GRATE OR COVER (OPTIONAL OR WHERE REQ'D BY 36" MIN. CODE) Ih'I� I .I um�=mi TYPICAL DETAIL AT BASEMENT EGRESS NOT TO SCALE BOMAN & KEMP 5236-60 EASY -WELL STEPS OR ESCAPE LADDER (WHEN REQ'D BY CODE) DRAINAGE STONE COMPACTED BACKFILL BELOW AND AROUND WINDOW WELL o ' o z I _ GRADE I I#4 HORIZONTAL TOP CONT. I BITUMINOUS FOUNDATION 8" FDN DAMPPROOFING BELOW GRADE WALL U.N.O. VERTICAL REINFORCING WHERE SPECIFIED ON 5 1/2" FOUNDATION PLAN O ao I BASEMENT #4 HORIZONTAL CONTINUOUS IAT WALL MID -HT PERIMETER BASEMENT FRAMING AND/OR INSULATION, I SEE FDN PLAN FOR IINFORMATION #4X2'-0" LONG I I NOTE: PERIMETER DOWELS AT I FOUNDATION DRAINAGE EACH CORNER _ NOT SHOWN ON TYPICAL AND 2'-0" O.C. I i DETAIL, COORDINATE WITH IN BETWEENVERIFIED SITE CONDITIONS AND FOUNDATION PLAN NOTES J-1 FREE DRAINING BACKFILL (WITH GP, GW, SW, SP SOIL) (2) #4 CONTINUOUS p T-4" U.N. 0. z D TYPICAL FOUNDATION WALL DETAIL 0 NOT TO SCALE SEE TYPICAL BLDG SECTION FOR INFORMATION NOT SHOWN GARAGE 00 w Q — — 4 INCH CONCRETE o 0 1 1 SLAB ON GRADE OVER U) z COMPACTED BACKFILL AND SUBBASE I 2X4 OR 2X6 P.T. BRG. PLATE (SEE PLAN FOR WALL SIZE) GRADE NOTE: WHEN FROST WALL IS EXTENDED #4 HORIZONTAL DOWN FOR FULL HEIGHT BASEMENT WALL TRANSITIONS, INSTALL VERTICAL 8" FROST REINFORCING IN FROST WALLS EXCEEDING WALL U.N.O. 4FT HEIGHT TO MATCH AND ALIGN WITH BASEMENT WALL REINFORCING NOTE: NO VERTICAL FOUNDATION WALL REINFORCING REQUIRED AT FROST WALLS BACKFILLED ON z BOTH SIDES EVENLY o I #4X2'-0" LONG DOWELS AT EACH I O CORNER AND 4'-0" O.C. IN BETWEEN z I (2) #4 CONTINUOUS • b Nk T-4" U.N.O. TYPICAL GARAGE FROST WALL SECTION NOT TO SCALE SEE TYPICAL BLDG SECTION FOR INFORMATION NOT SHOWN ROCI=KAI=KIT VAPOR BARRIER - 10-INCHES OF #2 - CRUSHED STONE BEDDING RECOMMENDED WHEN GROUNDWATER WITHIN 5FT OF SLAB LEVEL z v FREE DRAINING SAND BACKFILL (GP, GW, SW, SP SOIL) #2 CRUSHED STONE DRAINAGE STONE AT PERIMETER WRAPPED IN NON -WOVEN SEPARATION GEOTEXTILE 4"0 PERFORATED PIPE AT PERIMETER OF BASEMENT/FDN UNIFORMLY SLOPED TO DAYLIGHT LOCATION OR SUMP PIT PER LOCAL JURISDICTION AND SITE CONDITIONS, INSTALL BELOW BOTTOM OF SLAB OR T/FTG LEVEL NOTE: WHERE SEASONALLY ELEVATED GROUNDWATER IS PRESENT (WITHIN 4FT OF BASEMENT SLAB) PERIMETER FOUNDATION DRAINAGE IS RECOMMENDED WITH A DAYLIGHT OUTLET OR BY MEANS OF A COLLECTION SUMP (MIN 24" OX24, DEEP) AND AN AUTOMATIC MECHANICAL PUMP SYSTEM (BACKUP POWER RECOMMENDED). THE NEED FOR A PERIMETER FOUNDATION DRAINAGE SYSTEM AND THE PRESENCE OF GROUNDWATER SHALL BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION TYPICAL DRAINAGE DETAIL AT ELEVATED GROUNDWATER NOT TO SCALE SEE TYPICAL FDN & BLDG SECTIONS FOR INFORMATION NOT SHOWN DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY - CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME -CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION, DRAWING STATUS: ENGINEERS STAMP: tiOF �w p Cr d) O. 07906 OAFS S 10 7/18/24 REVISIONS 5 4 3 2 7/18/24 REVISED FRONT GABLE 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED DATE: 6/19/24 DRAWN BY: DWRPE PROJECT: CERRONE BUILDERS INC LOT 16 VUS QUEENSBURY, NY DRAWING TITLE FOUNDATION PLAN & DETAILS DRAWING NO. DWG=4 OF 7 w a z W Z a 0 m z z w z z O U z w o F w 0w Ow IA S w of w= U O o it OJ a 4 w ww wa Oz a} w� a O� U w w mZ z� J a J Q N =o co N Z o g~ a� w� (� �IL O SECTION THRU GARAGE NOT TO SCALE TRUSS MANUFACTURER TO DESIGN TRUSSES FOR TEMPORARY CANTILEVER OVER PORCH AT EXTERIOR WALL (DURING CONSTRUCTION) ?ICAL BUILDING SECTION PICAL DETAILS FOR ADDITIONAL JATION NOT SHOWN HE 71 SECTION AT PORCH MEMENNOW SECTION THRU BUILDING NOT TO SCALE SEE TYPICAL BUILDING SECTION AND TYPICAL DETAILS FOR ADDITIONAL INFORMATION NOT SHOWN DAN I E L W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN, IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY - CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ENGINEERS STAMP: OF ..._,. 0 0) �� o �O 07900 R�fi�SSIONP� 7/18/24 REVISIONS 5 4 3 2 7/18/24 REVISED FRONT GABLE 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED DATE: 6/19/24 DRAWN BY: DWRPE PROJECT: CERRONE BUILDERS INC LOT 16 VUS QUEENSBURY, NY DRAWING TITLE BUILDING SECTIONS DRAWING NO, DWG=5 OF 7 ui a z } J W d 0 r m z z W z O U Z W 0 � W 0 Q W W 00 W = U 0 K O J J d Q W w W af 1i O z a Lu a , O ?� U J W W mz 00 r J Q N 2N N Z O <_ W Fa O T/FOUNDATION WALL 2" CL TYP 2'-0" MIN. BASEMENT SASH OR I OTHER OPENING I (1) #4 REBAR (1) #4 REBAR ES OF OPNGS EXTENDED MIN. FULL HT I Z-0" BEYOND I OPENING EDGES FOUNDATION WALL ALL SIDES ( I TYPICAL REINFORCING AT FOUNDATION WALL EDGE OR OPNG NOT TO SCALE LAP PLACE VERT BAR AT INTERSECTION OF HORIZ BARS CORNER BARS TO MATCH HORIZ WALL REINFORCING SIZE AND SPACING (ALTERNATIVELY USE END HOOKS ON HORIZ REINF) NOTE: PROVIDE 2'-0" MIN LAP FOR DOWELS AND CORNER BARS ALTERNATE SIDE OF HOOK HORIZ WALL REINFORCING TO BE EXTENDED INTO INTERSECTING WALL AND TERMINATED WITH A T-4" LG END HOOK TYPICAL WALL CORNER/INTERSECTION REINFORCING DETAIL NOT TO SCALE SAW -CUT CONTRACTION JOINTS -� (INSTALL EQUALLY SPACED ACROSS EACH SLAB AREA/ MAX 15FT O.C. IN EACH DIRECTION, ALIGNED WITH CENTER OF ROOM?, SPACES, COLUMNS, OR WHERE SPECIFIED ON PLANS (MIN. 1/4" X 1" DEE"P), FILL WTIH SEMI -RIGID JOINT SEALANT REINFORCING TO BE--� SUPPORTED BY CHAIRS OR CONC. BRICKS BARRIER WITH LAPPED AND SEALED EDGES (BASEMENT/CONDITIONED SPACES ONLY) 4X4-W2.9 X W2.9 WWM OR #4 AT 16" OC EW (REINFORCING SHOWN IS RECOMMENDED BUT OPTIONAL) BASEMENT: 10" COMPACTED GRANULAR SAND OR SAND/GRAVEL SUBBASE (3/4" t CRUSHED STONE RECOMMENDED WHEN SHGW WITHIN 4FT OF SLAB ELEVATION) GARAGE/PORCHES: 6" COMPACTED GRANULAR SAND OR SAND/GRAVEL SUBBASE UNDISTURBED SUBGRADE OR COMPACTED STRUCTURAL FILL/BACKFILL PER SITE CONDITIONS 18" MIN. BEN D- z_ / o`er /� /1*01 2'-0" LAP 0 _� 1 (TYPICAL) 18" MIN. EXTENSION EACH END SLAB ON GRADE NOTES: 1, LAP AND TAPE VAPOR BARRIER EDGES MIN. 18" AT SPLICES 2. PROTECT SLAB FROM MOISTURE OR PRECIPITATION AND FROM EXCESSIVELY HOT/COLD TEMPERATURES DURING INITIAL CURING PERIOD. 3. SLAB CONSTRUCTION AND RELATED WORK, INCLUDING MEANS AND METHODS OF CONSTRUCTION, SHALL BE COMPLETED IN A SEQUENCE AND MANNER THAT CONFORMS TO AND IS CONSISTENT WITH THE AMERICAN CONCRETE INSTITUTE AND ACI 302.1 GUIDE TO CONCRETE FLOOR AND SLAB CONSTRUCTION. 4. FLOOR SLAB AREAS SHALL BE UNIFORM, SMOOTH, AND FLAT AND SHALL BE FINISHED FREE OF TROWEL MARKS. RIDGES. DEPRESSIONS, OR ROUGH ROUGH SURFACES UNLESS OTHERWISE SPECIFIED. WHERE ADJACENT TO PREVIOUS/EXISTING CONSTRUCTION SLABS SHALL BE INSTALLED FLUSH WITH ADJACENT EXISTING FLOOR SURFACES. NEATLY FINISH BUTTING EDGES AND JOINTS IN SLABS TO MINIMIZE JOINT APPEARANCE OR TRANSLATION THROUGH SCHEDULED FLOOR FINISHES. 4.1. APPLY SMOOTH TROWEL FINISH TO SLAB SURFACES EXPOSED TO VIEW OR WHERE SLAB SURFACES WILL BE SUBSEQUENTLY COVERED WITH A FLOOR FINISH. 4.2. LEVEL ALL FLOOR SLABS UNLESS SLOPED FOR DRAINAGE PURPOSES. 4.3. APPLY A NON -SLIP FINE BROOM FINISH TO EXTERIOR SLABS ON GRADE OR SLABS THAT WILL SUBSECJEN__ ' RECEIVE A FLOOR FINISH REQUIRING BONDING TO THE SLAB SURFACE. 4.4. SLABS THAT ARE SLOPED FOR DRAINAGE SHALL BE UNIFORMLY SLOPED TO PREVENT PONDING AND �-IE ACCUMULATION OF WATER ON THE SURFACE. SLOPE SURFACES MINIMUM 1%AT COVERED AREAS (PORCHES AND GARAGES) AND MINIMUM 2% AT EXTERIOR LOCATIONS. 5. COORDINATE SLAB BLOCK -OUTS OR PENETRATIONS FOR CONDUIT, PIPING, OR SIMILAR UTILITIES WITH GENERAL CONTRACTOR PRIOR TO START OF CONSTRUCTION. THE PERIMETER OF ALL SLAB PENETRATIONS (PIPES CONDUITS, ETC), AROUND BUILDING COLUMNS, AND ALONG ALL EDGES OF VERTICAL SURFACES ABUTTING OR PROJECTING THROUGH SLABS SHALL HAVE PRE -MOLDED ISOLATION JOINT MATERIAL INSTALLED FOR THE FULL THICKNESS OF THE SLAB, MINIMUM 1/2" THICK. WHERE EXPOSED TO MOISTURE RECESS ISOLATION MATERIAL AND INSTALL AN ELASTOMERIC JOINT SEALANT. TYPICAL SLAB ON GRADE DETAIL NOT TO SCALE PORCH COLUMN PER PLAN SIMPSON ABU44Z/ABU66Z OR EQUAL POST BASE (FILL ALL NAIL HOLES WITH 16D GALV) 5/8"0 GALV WEDGE OR ADHESIVE ANCHOR TO CONCRETE MEMBRANE FLASHING JOINT SEALANT CONCRETE SLAB RADIUS SLAB SUBBASE AND COMPACTED FILL TOOLED EDGES SLOPE 12" 0,5 MIN - MATCH #4 FOOTING REINFORCING - SEE FOUNDATION PLAN NOTE: VERIFY AND COORDINATE FOOTING STEP LOCATIONS WITH FIELD VERIFIED CONDITIONS AND SITE GRADING. MAINTAIN THE MINIMUM FROST PROTECTION DEPTH AT ALL TIMES FROM FINISHED GRADE TO BOTTOM OF FOOTING TYPICAL STEPPED FOOTING DETAIL NOT TO SCALE "^^� SHEATHING DAIRY NAILING 3 GABLE END TRUSS FULLY SHEATHED EXTERIOR FACE OF GABLE END TRUSS 2X4 BLOCKING AT 24" OC WITH SIMPSON LUS24 FM HANGER TO BOTTOM CHORD SIMPSON H1, TYP 2X FRAMED WALL BELOW GABLE END TRUSS TYPICAL GABLE END TRUSS TO TM/ALL DETAIL ROOF TRUSSE 24" OC RAISED HEEL ENERGY TRU: SIMPSON H1 / EACH TRUSS 2X6 BEARING HORIZONTAL REINFORCING WHEN SPECIFIED SHALL CONTINUE THRU JOINT -----=--L=-------= JOINT SEALANT EACH SIDE OF WALL FOR FULL HT 3/4" CHAMFEF EF OF WALL 3/4" CHAMFER EACH SIDE WITH MASTERSEAL NP2 JOINT SEALANT FULL HT, OR EQUAL TYPICAL FOUNDATION WALL CONTROL JOINT NOT TO SCALE (WCJ'S ARE OPTIONAL BUT IMPORTANT TO CONTROLLING THERMAL AND SHRINKAGE CRACKING OF CONCRETE FDN WALLS, SEE PLAN AND/OR FDN NOTES FOR RECOMMENDED JOINT LOCATIONS) RAISED HEEL ENERGY TRUSS AT SUPPORT TYPICAL TRUSS/RAFTER BEARING DETAIL 1 1/2" MIN CLEAR SPACE FOR VENTILATION, ELSE USE BAFFLES/VENTS EACH BAY, TYPICAL 9" t HT - R-38 BATT 14" t HT - R-49 BATT 12 SEE PLAN MIN. (3) 8d NAILS SHEATHING TO VERTICAL WEB OF _ TRUSS, TYP CEILING JOISTS SEE ROOF RAFTERS AT PLAN 16" OC SEE PLAN NOTE SIMPSON TIE EACH BEARING AT RAFTER; H1 AT RAFTER DROPPED ONLY LOC'S AND H10-2 PORCH FOR RAFTERS LAPPED BEAMS WITH CLG JSTS SIMILAR RAFTER FRAMING AT SUPPORT NOT TO SCALE NOTE: ADJUSTMENTS TO OVERHANGS MAY BE REQUIRED AT ROOF SLOPE CHANGES TO ALIGN FASCIAS - COORDINATE W/ROOF PLAN, BEARING ELEVATIONS, AND TRUSS DESIGN/LAYOUT PRIOR TO CONSTRUCTION IRDER TRUSS OR OOP BEAM (POINT DAD LOCATION) TUD COLUMN BELOW DINT LOAD (MINIMUM WIDTH TO MATCH BEAM OR GIRDER TRUSS WIDTH) 2X4 SQUASH BLOCKS (MINIMUM WIDTH TO MATCH COLUMN WIDTH PLUS TWO BLOCKS) FLOOR BEAM (POINT LOAD LOCATION) STUD COLUMN BELOW POINT LOAD (MINIMUM WIDTH TO MATCH BEAM OR GIRDER TRUSS H BLOCKS VIDTH TO MATCH IDTH PLUS <S) N WALL MIN.( 3" LG STEE" .� MIN 3/8" THK X BEAM WIDTH X 8" LG MIN. (4) 5/16"0 TAPCONS OR GALV WEDGE ANCHORS INTO SLAB/FTG (3" EMBED) STEEL BASE - PLATE MIN 3/8" THK X 5.5" SQ WT STEEL PIPE COLUMN WITH WELDED BASE/CAP PLATES, PRIMED (PRE -MANUFACTURED LALLY COLUMNS WITH CAPACITY > 15,000 LBS ARE AN ACCEPTABLE ALTERNATIVE, WITH TOP AND BOTTOM BEARING PLATES AND MECHANICAL ANCHORS TO BEAM AND SLAB, MINIMUM 11 GA.) INTERIOR COLUMN FOOTING PER FOUNDATION PLAN TYPICAL BASEMENT COLUMN DETAIL NOT TO SCALE NOTCH SILL PLATE AT BEAM POCKET AS REQ'D FLOOR JOISTS PER PLAN DROPPED FLOOR BEAM 2X4 PRESSURE TREATED BEARING PLATE & SHIMS FOUNDATION WALL TYPICAL WOOD BEAM POCKET DETAIL NOT TO SCALE CONTRA113 JSI-'t S►*.ATNED BRACED WALL PAL lEE tING tAth"A L9NGTH P&GU1RPNENIS OF ".ABLE a.6 EXTEW OF MEAC1 R WITH 154"LE PORTAL FRAMES iTWO BRACED 'WALL PAttiE L IE",I Or- HkAIDER WITH SmOd.E PORTAL%RANE 4CT.4E BR.ArlO 4'44At .P'At<ELI FASTE?i K[NG STUD -I a' FINlSs *z'h7OtliOF- OPENIIiaC toLAOILA WITH @ -0OR SPVGL.E OR DOUITICE P'GtRI ► TEt15ION STRAP f*u Y »ALL HEIGHT , ` ----------------------------- a,• r s . MIN. 3**1171.• kI:T HgADL4 5tEttL NEhFJEI•t Pfg TiEL� f ' .' SPACER IS USED, PLACE Ott BAAC:M-S► _* Of **_ADE}+ g FASTEN SIHEATHING TO HEADER WITH ED COMIAON OR GALYAHI.M0 90.x SAILS IN 3' GRIC PA11ERNAS S+40,'.Ii y T,7�- El TO .lALit.STUC STRAPPEK :ABLERW2.1@C,.1Ott O'tHSIL:fSOfOff��OPPO'3aTE S1t af' SHEATHINGwo VIN. UOUBLE .^"xr FAA►s'p & COVEA10 WITH MIN, g le it' IO,, WT3007 STRLK:IURA.L PANEL SHEATHING o ^� h"HBO COMMON OR GAL)OWlIZED BOX NAILS A" 3- U.C. tN ALL F R"ING CSTUDS, SLOCA t4G. AhO StLLS1 TYP. • MlFt LW4TH OF PATN&L PER TABLE 145,!(13 r:• } • 1olVL Ia 1 ' io DIALIETER AtOCHDIi BOL t S Ih51ALLED PER SECTM' R40L3A.E WIT? -I AO ,t 2`x7xq'x" PLAT E WA,SHE R ; CAI #x�iy°G` �190 c G a�w n Op rO IQsae. ''a4. e_Q_to ,_•, Now OVER CONCRETE OR MASONRY BLOCK FOUNDATION 1 ` ►'t=5rkUClUKOW.P .14EL %wl. SULE PLATE SFEATHPiG tO TOP Ol: BAUD TO JiO151 PFA OR fxtM JOIST tMSLE R 023(l) TABLE W2.. 10!. - t04`.OP%r4SltE SIDE BRACED WALL LINE• ... CONtfYUOUSLY SH"THE L s , • f 'AllH YvOOD STRLCtURAL • • ... PANELS If NEEDED. P'AttL ;.• SPLICE EDGES SHAU•� OCCUR O%C-R AND BE ►,JttED TO CMIPAON , -- BLOCKNM6WIMIN IHE ►,t�OL6 2w M TT*_ ;.. POR TAL• LErt HtiG 1 T C" ROW OF 3' O.C. .r 14Ay4r. IS RED u*M_7 •� tN EACH Pk*JLL EUGE Oft T"sPK:AL PCYRTAL R ♦fr ---� HAM* COkSIR: cflo`tw. r. 'M h=iN. DOUBLE 2xa POST (til4G AND JACK StUr_)? T+UntBEN 4l• JAG1a �" Sh1DS PER TABLES Rw�`.r(t I a t2l ;, ANCHOFT Sc Lt5 PER SEC t ON R401.1.6 rlkf' ,���j` FitA41iNGA`1 .: PULD ACROSS SHEATHING Jolt-0 *#1tl C,APACIT Y OF 5 *9 LBS I 14E HORtZ0141ALANO YERT1CAL 11FRL- c r10NS �4OOL=STRUIC1lr%tAL PAIrfL 5f4-Ar"M OVER APPROVED we (XT RIM J01'� OVER RAISED WOOD FLOOR - FRAWNG ANCHOR OPTION i'V."LRE PO14tAL SHEA'HING COES W' LAP(YJ ER BAND UK "I JOIV1 :; w5A){TD S tRUC 1 LWAL SII"DEL hAll 50 F PtAAT1e SHIEATHING to top OJ BAND TO Jow MR OR FUM JOIST TA-_t: 1011=30) to3o: a. At 1 ACH SHILAI H04G 10 BAVD OR FM JIMST %%4 t 9D COWA014!'MAILSAt 3' O.C. TOPAM DOTtO►A ' - .�aG s1Lrctt_A w1�.=t stEhTl�,c APPM ��� OKttn+JDls. OVER RAISED WOOD FLOOR - OVERLAP OPTION 4't. t'LW 7AL SHEA? HV LAPIS 014.P{ BAND OIL HR1 BOARL'`t FRONT ELEVATION FAStEN Taw PLATE TO HE.ACILA tout r1H t !S�O i,XMS Of 16D NAIIL5 At r O.C. I yv. tvit. 1w WE= S1NUC*URAL PANEL SHE AT HIND i NAIL SOLE ?LATE TO JC6ST PER TABLE 1 �- APYFTC3tiELI BAtdt3 o, - OR Rai Jots r Ile +dAA SOLE PLAM TO JOiffi1 or K `TABLE RM7.30 i �"-- APPROVED SAINIG OR RIIIM JOTS e SECTION FIGURE R602.10.6.4 METHOD CS-PF-CONTINUOUSLY SHEATHED PORTAL FRAME PANEL. CONSTRUCTION TYPICAL GARAGE PORTAL FRAME DETAIL NOT TO SCALE PORTAL FRAME NOTES: 1. DETAIL PROVIDED IS FROM THE 2020 RESIDENTIAL CODE OF NYS AND IS REQUIRED WHERE THE CONTINUOUSLY SHEATHED WALL PANEL EACH END OF THE GARAGE DOOR OPENING IS LESS THAN THE MINIMUM REQUIRED FOR THE CS-G WALL HEIGHT (8'-24", 9'-27", 10'-30"). THE MINIMUM CS-PF PANEL WIDTH EACH END OF THE HEADER FOR THE GIVEN WALL HT SHALL BE AS FOLLOWS; 8'-16", 9'-18", 10'-20". 2. ENGINEER IS NOT RESPONSIBLE FOR THE PORTAL FRAME DESIGN OR CONFIGURATION NOR IS ENGINEER RESPONSIBLE FOR CONSEQUENTIAL EFFECTS OF INSTALLING THE PORTAL FRAME DETAIL AS SHOWN PER RCNYS CHAPTER 6. 3. LATERAL BRACING (DIAGONAL 2X FRAMING 24" OC TO ROOF/CEILING) IS RECOMMENDED FOR THE BOTTOM OF PONY WALL AND HEADER BEAM TO PREVENT UNDESIRABLE DISPLACEMENTS, VIBRATIONS, OR REDUCED STABILITY OF THE HEADER. 4. THE TENSION STRAP SHOWN EACH END OF THE PORTAL FRAME HEADER SHALL BE CAPABLE OF 4125 POUNDS OF TENSION, USE SIMPSON CMSTC16 WITH MINIMUM 30" LAP WITH JACK STUDS BELOW HEADER, OR EQUAL. DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY - CALL BEFORE YOU DIG -WAIT THE REQUIRED TIME -CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ENGINEERS STAMP: 7/18/24 REVISIONS w 5 4 3 2 7/18/24 REVISED FRONT GABLE L z J w Q 1 7/11/24 REVISED HIP/GABLES PROJECT NO.: 1881 SCALE: AS NOTED 0 z DATE: 6/19/24 w o DRAWN BY: DWRPE z k PROJECT: CERRONE BUILDERS INC W LOT 16 VUS IL Lu QUEENSBURY, NY 0 � U a:D� DRAWING TITLE ow a a TYPICAL SECTIONS & w W wa DETAILS Oz W 0- o� J DRAWING NO. m Z z T DWG=6 J a J Q N zuc OF 7 Ul U) a �O MANDETPIL STRUCTURAL MATERIAL STRENGTHS STRUCTURAL AND MISCELLANEOUS STEEL: ROLLED STEEL W SHAPES - ASTM A 992 ROLLED STEEL C, MC SHAPE - ASTM A 36 ROLLED STEEL PLATES, BARS, AND ANGLES - ASTM A 36 HOLLOW STRUCTURAL SECTIONS (HSS SQUARE/ROUND) - ASTM A 500, GR B PIPE - ASTM A53, TYPE E OR S, GRADE B HOT -DIP -GALVANIZING - ASTM A 123 AFTER FABRICATION WELD ELECTRODES -AWS E70 BOLTING ASSEMBLIES (HEAVY HEX GROUP 120) -ASTM F3125, GRADE A325 ASTM A563, ASTM F436, TYPE 1, MIN 3/4" O UNO ANCHOR RODS/BOLTS -ASTM F 1554, GRADE 36 THREADED ANCHORS -ASTM A 36 POWDER ACTUATED FASTENERS (PAF) -HILTI 0.1770 DS/EDS ADHESIVE ANCHORS (FOR SOLID CONCRETE) -HILTI HIT-HY 200-A/R V3 ADHESIVE ANCHORS (FOR MASONRY) -HILTI HIT-HY 270 (USE SCREEN TUBES AT HOLLOW SUBSTRATE) -NON-SHRINK GROUT: MASTERFLOW 928 BY MASTER BUILDERS SOLUTIONS CAST -IN -PLACE CONCRETE: -FOOTINGS, PIERS, FOUNDATION WALLS, & INTERIOR SLABS fc = 3,000 psi@28DAYS -EXTERIOR, PORCH, & GARAGE SLABS ON GRADE fc = 3,500 psi@28DAYS -W/C RATIO 0.45-0.50 -SLUMP 3"-6" -AIR CONTENT FOR EXT/EXPOSED CONCRETE 6.5% t 1.5% (0-2% AT INTERIOR CONCRETE) -ASTM C 260 ENTRAINED AIR FOR EXTERIOR OR EXPOSED CONCRETE -ASTM C 150 TYPE I OR II PORTLAND CEMENT -MAXIMUM CEMENT SUBSTITUTION ASM C 618 CLASS F FLY ASH 15% (LOI<4%) -ASTM C 494 TYPE C OR E NON -CHLORIDE ACCELERATOR -ASTM C 33 FINE AGGREGATE (FOR CONCRETE), MUST BE 36% OF TOTAL AGGREGATE -COARSE AGGREGATE (FOR SLABS) SHALL BE A BLEND OF WASHED CRUSHED STONE MEETING THE REQUIREMENTS OF ASTM C 33 FOR COARSE AGGREGATE, SIZE 57 OR 67 -COARSE AGGREGATE (FOR FTGS/WALLS/PIERS) SHALL BE BLEND OF WASHED CRUSHED STONE MEETING THE REQUIREMENTS OF ASTM C 33 FOR COARSE AGGREGATE, SIZE 467 OR 57 -REINFORCING/DOWELS: ASTM A 615, GRADE 60 LIGHT -FRAMED WOOD CONSTRUCTION: -STRUCTURAL WOOD FRAMING: NLGA NO. 1/2 OR BETTER, SPRUCE -PINE -FIR (SPF) WITH MINIMUM E-1,400,000 PSI, U.N.O. ON PLANS -SUBFLOORING: 23/32" THK ADVANTECH T&G FLOOR SHEATHING OR EQUAL 23/32" THK APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 48/24 -ROOF SHEATHING: 1/2" THK ZIP SYSTEM OR EQUAL 15/32" THK APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 32/16 -EXTERIOR WALL SHEATHING: 7/16" THK ZIP SYSTEM WALL SHEATHING OR EQUAL 9/16" THK APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 -UNFINISHED BOLTS AND ANCHOR BOLTS: ASTM A 307, GRADE A. -SOUTHERN PINE (WHERE SPECIFIED "SYP" OR "S.& SO. PINE"): SPIB SELECT STRUCTURAL GRADE WITH MINIMUM E=1,800,000 PSI -DOUGLAS FIR (WHERE SPECIFIED "DF"): NLGA NO. 1 DOUGLAS FIR -LARCH (NORTH) WITH MINIMUM E=1,800,000 PSI -MANUFACTURED MICROLLAM LVL OR PARALLAM PSL: MINIMUM E=2.OX10' PSI AND Fb=2900 PSI AS MANUFACTURED BY TRUS JOIST, OR EQUAL -PRESSURE TREATED FRAMING: SOUTHERN PINE, NO. 2 OR BETTER, PRESSURE PRESERVATIVE TREATED AND RATED FOR APPLICATION, EXPOSURE, AND USE. MASONRY CONSTRUCTION: -CONCRETE BLOCK: PROVIDE MASONRY WALL ASSEMBLY WITH AVERAGE COMPRESSIVE STRENGTH fm OF 1500 PSI. CMU SHALL BE ASTM C 90 WITH AVERAGE NET COMPRESSIVE STRENGTH OF 1900 PSI, NORMAL WEIGHT. -MORTAR: READY -MIX ASTM C 270 OR ASTM C 1142, TYPES -GROUT: ASTM C 476, MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI, 8-10" SLUMP -BRICK: ASTM C 216, TYPE FIBS, GRADE SW, WITH MINIMUM AVERAGE NET AREA COMP. STRENGTH 3000 PSI -REINFORCING/DOWELS: ASTM A 615, GRADE 60 STAIR NOTES 1. STAIRWAY SHALL NOT BE LESS THAN 36 INCHES WIDE IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4 1/2 INCHES ON EITHER SIDE OF THE STAIRWAY AND THE MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE LESS THAN 31 1/2 INCHES WHERE THE HANDRAIL IN INSTALLED ON ONE SIDE AND 27 INCHES WHERE THE HANDRAILS ARE PROVIDED ON BOTH SIDES. 2. THE MAXIMUM RISER HEIGHT SHALL BE 8 1/4 INCHES AND THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES. 3. THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6-8" MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM. 4. PORCHES, BALCONIES, OR RAISED FLOOR SURFACES LOCATED MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36 INCHES IN HEIGHT. OPEN SIDES OF STAIRS WITH A TOTAL RISE OF MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 34 INCHES IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. 5. REQUIRED GUARDS ON OPEN SIDES OF STAIRWAYS, RAISED FLOOR SURFACES, BALCONIES, AND PROCHES SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES THAT DO NOT ALLOW THE PASSAGE OF A SPHERE 4 INCHES OR MORE IN DIAMETER. 6. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH STAIRWAY WITH TWO OR MORE RISERS. HANDRAIL HEIGHT, MEASURED ABOVE THE TREAD NOSINGS, SHALL BE NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES, ALL REQUIRED HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS FROM A POINT DIRECTLY ABOVE THE TOP RISER OF A FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. 7. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1 1/2 INCHES BETWEEN THE WALL AND THE HANDRAIL 8. ENCLOSED ACCESSIBLE SPACE BENEATH STAIRWAYS SHALL HAVE WALLS AND UNDER STAIR SURFACE ON THE ENCLOSED SIDE WITH A 1/2 INCH GYPSUM COVERING. 9. EXTERIOR EXIT LANDINGS, STAIRS, DECKS, AND SIMILAR EXIT FACILITIES SHALL BE POSITIVELY ANCHORED TO THE PRIMARY BUILDING STRUCTURE USING HANGERS, LAG BOLTS, SCREWS, OR OTHER FASTENING SYSTEMS NOT SUBJECT TO WITHDRAWAL. 10. REQUIRED EXTERIOR EGRESS DOORS SHALL HAVE A LANDING OR FLOOR ON EACH SIDE OF THE DOORWAY. THE LANDING OR FLOOR AREA EACH SIDE SHALL BE MINIMUM 3'-0" X T-0". THE LANDING OR FLOOR SHALL BE MAXIMUM 1 1 /2" BELOW THE DOOR THRESHOLD ON THE SIDE UNDER THE DOOR SWING, AND MAXIMUM 8 1/4" BELOW THE THRESHOLD WHEN THE DOOR DOES NOT SWING OVER THE FLOOR OR LANDING. 11. ALL EXTERIOR DOORS, OTHER THAN ANY REQUIRED EGRESS DOOR, SHALL HAVE A LANDING OR FLOOR ON EACH SIDE OF THE DOORWAY. THE LANDING OR FLOOR AREA EACH SIDE SHALL BE MINIMUM 3'-0" X 3-0". THE LANDING OR FLOOR SHALL BE MAXIMUM 7 3/4" BELOW THE DOOR THRESHOLD ON EACH SIDE. A TOP LANDING IS NOT REQUIRED WHERE A STAIRWAY OF NOT MORE THAN TWO RISERS IS LOCATED ON THE EXTERIOR SIDE OF THE DOOR, PROVIDED THAT THE DOOR DOES NOT SWING OVER THE STAIRWAY. 12. A FLOOR OR LANDING IS NOT REQUIRED AT THE TOP OF AN INTERIOR FLIGHT OF STAIRS, INCLUDING STAIRS IN AN ENCLOSED GARAGE, PROVIDED THAT A DOOR DOES NOT SWING OVER THE STAIRS. FOUNDATION NOTES: 1. BEAR FOOTINGS ON FIRM UNDISTURBED SOIL. FOUNDATIONS HAVE BEEN DESIGNED FOR A PRESUMPTIVE SOIL BEARING PRESSURE OF 2000 PSF. IF SOILS ENCOUNTERED ARE EXPANSIVE, COMPRESSIBLE, SHIFTING, OR HAVE OTHER UNKNOWN CHARACTERISTICS, BUILDING CODE OFFICIALSHALL DETERMINE NEED FOR SOIL TESTING WHICH SHALL BE PERFORMED TO VERIFY SOIL PROPERTIES AND THE DESIGN PRESUMPTIVE BEARING PRESSURE. 2. MINIMUM DEPTH OF EXTERIOR FOOTINGS FOR FROST PROTECTION IS 4 FEET BELOW FINISHED GRADE, UNLESS ENTIRE STRUCTURE IS FULLY BEARING ON SOUND BEDROCK OR OTHER NON -FROST -SUSCEPTIBLE (NFS) BEARING MATERIAL/SURFACES. 3. LAP FOOTING AND WALL REINFORCEMENT 2 FEET AT SPLICES. PROVIDE CORNER BARS THE SAME SIZE AND NUMBER AS CONTINUOUS REINFORCEMENT, LAPPED 2 FEET WITH MAIN REINFORCEMENT. REFER TO TYPICAL DETAIL FOR MORE INFORMATION. 4. CAST STEPPED FOOTINGS MONOLITHICALLY. REFER TO DRAWINGS FOR TYPICAL STEPPED FOOTING DETAIL. SEE FOUNDATION PLAN :OR APPROXIMATE STEP LOCATIONS. VERIFY AND COORDINATE LOCATIONS WITH GRADING AND FIELD VERIFIED CONDITIONS AT THE TIME OF CONSTRUCTION TO MAINTAIN THE MINIMUM FROST PROTECTION DEPTH. 5. EXCAVATIONS SHALL BE LAID BACK TO PREVENT SLOUGHING IN OF SIDES. MAINTAIN SIDES AND SLOPES OF EXCAVATIONS IN A SAFE/STABLE CONDITION UNTIL COMPLETION OF BACKFILLING. FOUNDATION EXCAVATIONS AT BEARING SURFACES SHALL BE HAND TRIMMED TO REMOVE LOOSE MATERIAL OR RIDGES LEFT BY EQUIPMENT. COMPLY WITH OSHA REQUIREMENTS CONTAINED IN 1926 SUBPART P FOR ALL EXCAVATIONS. PROTECT i\ND SECURE OPEN EXCAVATIONS UNTIL BACKFILLED TO MATCH THE SURROUNDING GRADE. 6. BACKFILL FOUNDATION WALLS WITH SAND AND GRAVEL (GW, GP, SW, OR SP SOILS) WHICH ARE WELL -DRAINING, SOUND, DURABLE, AND FREE OF ORGANIC OR OTHER DELETERIOUS MATERIALS. INSTALL BACKFILL EVENLY ON BOTH SIDES OF WALLS WHERE NECESSARY TO PREVENT DISPLACEMENT OF CONSTRUCTION. BACKFILL SHALL NOT BE PLACED AGAINST BASEMENT WALLS UNTIL THE WALLS HAVE REACHED THE DESIGN STRENGTH AND HAVE BEEN ANCHORED TO THE FLOOR ABOVE, FINISHED GRADE AT PERIMETER OF FOUNDATION SHALL BE SLOPED TO DRAIN SURFACE WATER AWAY FROM BUILDING. THE GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM OF 6 INCHES WITHIN FIRST 10 FEET. 7. PLACE INTERIOR BACKFILL (BASEMENTS, GARAGES, AND PORCHES) AND SLAB SUBBASE MATERIAL IN LAYERS NOT MORE THAN 12 INCHES IN LOOSE DEPTH AND COMPACT TO 95 PERCENT OF THE MATERIALS MAXIMUM DENSITY AS DETERMINED BY ASTM D1557. 8, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACE LOCATED BELOW GRADE SHALL BE DAMP -PROOFED FROM THE TOP OF FOOTING TO FINISHED GRADE. DAMP -PROOFING SHALL BE A BITUMINOUS COATING OR 3 POUNDS PER SQUARE YARD OF ACRYLIC MODIFIED CEMENT. 9. THE UNDER -FLOOR SPACE CREATED IN CRAWL SPACES SHALL BE PROVIDED WITH VENTILATION OPENINGS THROUGH FOUNDATION WALLS OR EXTERIOR WALLS, THE MINIMUM NET AREA SHALL BE 1 SQUARE FOOT FOR EVERY 150 SQUARE FEET OF CRAWL SPACE. ONE SUCH OPENING SHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING. VENTILATION OPENINGS ARE NOT REQUIRED WHEN THE GROUND SURFACE IS COVERED WITH 6-MIL POLY VAPOR RETARDER, THE SPACE IS SUPPLIED WITH CONDITIONED AIR, AND THE EXTERIOR PERIMETER WALLS ARE INSULATED IN ACCORDANCE WITH CODE AS PART OF THE PERIMETER THERMAL ENVELOPE. 10. ANCHOR SILL PLATE OF EXTERIOR WALLS TO FOUNDATION WALLS WITH 1/2-INCH ANCHOR BOLTS 12 INCHES MAXIMUM FROM EACH END AND 4 FEET MAXIMUM ON CENTER IN BETWEEN. (MINIMUM OF TWO ANCHOR BOLTS IN EACH SILL PIECE.) EMBED ANCHOR BOLTS A MINIMUM OF 9 INCHES IN THE TOP OF CONCRETE FOUNDATION WALLS. 11. DO NOT CASTOR PLACE FOOTINGS OR FOUNDATION ELEMENTS IN WATER OR ON FROZEN GROUND. 12. CENTER FOOTINGS UNDER WALLS, PIERS, AND COLUMNS UNLESS NOTED OTHERWISE. 13, REINFORCE ALL CONCRETE AND FOUNDATION ELEMENTS IN ACCORDANCE WITH PLAN NOTES AND CORRESPONDING TYPICAL DETAILS AND SECTIONS, UNLESS OTHERWISE SPECIFIED OR DETAILED. 14. ALL EXCAVATION AND UNDERCUTTING OR SIMILAR ACTIVITY ADJACENT TO PREVIOUSLY INSTALLED OR EXISTING CONSTRUCTION TO REMAIN MUST BE COMPLETED WITHOUT UNDERMINING OR COMPROMISING EXISTING WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF REQUIRED BRACING, SHORING, AND/OR SHEETING TO SUPPORT ADJACENT SOIL AND FOUNDATION/SLAB/EARTH LOADS WHEN EXCAVATING WITHIN AN AREA BEYOND A 30 DEGREE DOWNWARD ANGLE FROM EXISTING CONSTRUCTION SUCH AS SLABS, FOOTINGS, OR FOUNDATION BEARING ELEVATIONS. 15. IF EXCAVATIONS ARE REQUIRED TO EXTEND BELOW THE SEASONAL GROUNDWATER ELEVATION AS DETERMINED UPON INITIAL EXCAVATION WORK, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FULLY DE -WATERING THE SUBSURFACE TO MINIMUM TWO FEET BELOW THE LOWEST WORK POINT PRIOR TO PROGRESSING WITH EXCAVATION OR SUBSEQUENT FOUNDATION/SUBSURFACE WORK. 16. VERIFY SIZE AND LOCATION OF MECHANICAL, ELECTRICAL, OR UTILITY PENETRATIONS OR OPENINGS THROUGH CONCRETE ELEMENTS PRIOR TO PLACING CONCRETE. PROVIDE CAST -IN PVC OR GALVANIZED SLEEVES OR CHASES FOR UTILITY, PIPING, CONDUIT, OR DUCT PENETRATIONS. PROVIDE ISOLATION MATERIAL AROUND ALL NON -SLEEVED PENETRATIONS OR EMBEDDED ITEMS PRIOR TO CASTING CONCRETE. DO NOT LOCATE PENETRATIONS THROUGH CONCRETE COLUMNS, PIERS, BEAMS, GRADE BEAMS, OR FOOTINGS UNLESS SHOWN ON DRAWINGS OR ACCEPTED BY ENGINEER. 17. CONCRETE COVER FOR REINFORCEMENT SHALL BE AS FOLLOWS UNLESS DETAILED OTHERWISE: COVER FOOTINGS POURED AGAINST EARTH 3" SURFACE EXPOSED TO WEATHER OR EARTH (INCLUDING SURFACES OF FOUNDATION WALLS COVERED WITH WATERPROOFING MEMBRANE AND/OR INSULATION: BARS LARGERTHAN #5 2" #5 BARS OR SMALLER 1 1/2" SURFACES NOT EXPOSED TO WEATHER OR EARTH: SLABS AND WALLS 3/4" BEAM, GIRDERS, PIERS, AND COLUMNS 1 1/2" BETWEEN BARS AND EMBEDDED ITEMS: IN CONCRETE ELEMENTS EXPOSED TO WEATHER OR EARTH 1 1/2" IN CONCRETE ELEMENTS NOT EXPOSED TO WEATHER OR EARTH 3/4" 18. ROUGHEN SURFACES OF CONCRETE WHICH WILL BE IN SUBSEQUENT CONTACT WITH EXISTING OR OTHER INSTALLED CONCRETE WORK (SUCH AS BETWEEN T/FTG AND PIERS OR AT WALL CONSTRUCTION JOINTS). APPLY A LIQUID BONDING AGENT TO IN -PLACE CONCRETE SURFACES PRIOR TO INSTALLING SUBSEQUENT CONCRETE. LIQUID BONDING AGENT SHALL BE MASTEREMACO ADH326 BY MASTER BUILDERS SOLUTIONS, OR APPROVED EQUAL. 19. CONTRACTOR SHALL PRE -DETERMINE CONSTRUCTION SEQUENCE AND CONCRETE POUR SCHEDULE PRIOR TO START OF WORK. CAST ALL CONCRETE ELEMENTS MONOLITHICALLY UNLESS OTHERWISE SPECIFIED OR APPROVED BY ENGINEER (WALLS, FOOTINGS, AND ETC). 20. DO NOT ALLOW COLD JOINTS IN CONCRETE WORK DUE TO DELAYS AND CONTRACTOR SHALL PLAN POUR SEQUENCE ACCORDINGLY. CONCRETE SHALL BE PLACED IN ONE UNIFORM CONTINUOUS PROCEDURE FROM BOTTOM TO TOP OF PLACEMENT. 21. CONSOLIDATE ALL CONCRETE IMMEDIATELY AFTER PLACEMENT USING INTERNALLY PLACED MECHANICAL VIBRATING EQUIPMENT OR DEVICE CAPABLE OF TRANSMITTING VIBRATION TO CONCRETE IN FREQUENCIES OF NOT LESS THAN 5000 VIBRATIONS PER MINUTE. 22. CONCRETE WHICH IS TO BE PUMPED SHALL HAVE PIPES AND PUMPING SYSTEM WITH A MINIMUM DIAMETER AND CAPACITY SUFFICIENT FOR THE PLANNED CONCRETE MIX. 23. ALL CONCRETE WORK SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF ACI-318 AND RELATED OR REFERENCED STANDARDS/GUIDES/REPORTS CONTAINED WITHIN ACI-318, 24. ALIGN FOUNDATION WALL CONSTRUCTION/CONTROL JOINTS WITH JOINTS IN OTHER WORK AND/OR FINISHES. VERIFY AND COORDINATE JOINT LOCATIONS IN FIELD IN COORDINATION WITH PROJECT REQUIREMENTS AND PREFERENCES OF THE OWNER. FILL FOUNDATION WALL CONTROL AND CONSTRUCTION JOINTS WITH MASTERSEAL NP2 JOINT SEALANT BY MASTER BUILDERS SOLUTIONS OR EQUAL. 25. AT INTERSECTIONS OF CONCRETE WALLS, PROVIDE CORNER BARS IN OUTER LAYER THE SAME SIZE AND SPACING AS HORIZONTAL REINFORCEMENT LAPPED WITH MAIN REINFORCING. INNER BARS AT CORNERS SHALL HAVE STD END HOOKS PROJECTED INTO THE PERPENDICULAR WALL. AT "T" INTERSECTIONS, PROVIDE STEM REINFORCING EXTENDED TO OUTER LAYER OF PERPENDICULAR REINFORCING AND TERMINATE WITH STD END HOOK. 26. EXPOSED CONCRETE SHALL HAVE A SMOOTH -FORMED -FINISH. USE ONLY PREPARED, CLEANED, SMOOTH -FORMING PANEL MATERIALS TO PROVIDE SMOOTH, CONTINUOUS, STRAIGHT, FLAT, EXPOSED SURFACES WITHOUT HONEYCOMBS, POCKETS, BUBBLES, FINS, RIDGES OR SURFACE VOIDS OR DEFECTS. USE FORM COATINGS AND RELEASE AGENTS APPLIED PRIOR TO PLACEMENT OF FORMS THAT WILL NOT STAIN OR BOND TO SURFACES AND THAT WILL NOT ADVERSELY AFFECT CONCRETE SURFACES. DO NOT APPLY FORM COATINGS OR RELEASE AGENTS TO IN -PLACE FORMS TO PREVENT COATINGS FROM BEING SPRAYED ON REBAR OR OTHER EMBEDDED ITEMS. 27. FORM TIES SHALL BE OF PROPER LENGTH, POSITION, AND TYPE TO EASILY SNAP -OFF OR BE REMOVED. DO NOT USE FORM TIES THAT WILL DEFLECT OR PROMOTE SURFACE DAMAGE OR SPALLING OF CONCRETE UPON REMOVAL. METAL FORM TIES SHALL BE AVOIDED WHERE POSSIBLE WITHIN 1-INCH OF ANY EXPOSED CONCRETE SURFACE TO PREVENT CORROSION AND/OR SURFACE STAINING. 28. SECURE EMBEDDED ITEMS IN -PLACE PRIOR TO CONCRETE PLACEMENT USING FORMS, BRACES, TEMPLATES, AND OTHER DEVICES. DO NOT WET -SET EMBEDMENTS, REINFORCING, OR ANCHORS. 29. TOLERANCES FOR CONCRETE WORK SHALL BE AS FOLLOWS; 29.1. FOOTINGS: 29.1.1. VARIATION OF DIMENSIONS IN PLAN: PLUS 2 INCHES OR MINUS 1/2 INCH. 29.1.2. VARIATION OF CENTER FROM SPECIFIED CENTER IN PLAN: 2 PERCENT OF FOOTING WIDTH IN DIRECTION OF VARIATION, PLUS OR MINUS 2-INCHES MAXIMUM VARIATION. 29.1.3. VARIATION OF BEARING SURFACE FROM SPECIFIED ELEVATION: PLUS OR MINUS 1/2 INCH. 29.2. PIERS, COLUMNS, AND WALLS: 29.2.1. VARIATION IN CROSS -SECTIONAL DIMENSIONS OF PIERS AND COLUMNS AND IN THICKNESS OF WALLS. PLUS OR MINUS 1/4 INCH. 29.2.2. VARIATION IN PLAN FROM SPECIFIED LOCATION IN PLAN: PLUS OR MINUS 1/2 INCH FOR ANY MEMBER IN ANY LOCATION. 29.2.3. DEVIATION IN PLAN FROM STRAIGHT LINES PARALLEL TO SPECIFIED LINEAR BUILDING LINES: 1/4 INCH FOR ADJACENT MEMBERS LESS THAN 20 FEET APART OR ANY WALL LENGTH LESS THAN 20 FEET; 1/2 INCH FOR ADJACENT MEMBERS 20 FEET OR MORE APART OR ANY WALL LENGTH OF 20 FEET AND GREAT 29.2.4. DEVIATION ;fER, 29-2-5. VARIATION' 1-INCH MAXIMUM FOR ENTIRE HEIGHT. 29.2.6. DEVIATION FROM PLUMB; 114 INCH FOR ANY 10 FEET OF HEIGHT, 120 FEET APART OR ANY WALL L NPLUS OR MINUS 112 INCH FOR ANY MEMBER IN ANY LOCATION, OF 20 FEET AND GREATER. IN ELEVATION FROM SPECIFIED ELEVATION: S TO SPECIFIED GRADE LINES: 114 INCH FOR ADJACENT MEMBERS LESS TH 29.3, ANCHOR ROD IN ELEVATION FROM LINES PARALLEL ADJACENT MEMBERS 20 FEET OR MORE APART OR ANY WALL LENGTH' 29.3�1. VARIATION LENGTH LESS THAN 20 FEET;112 INCH FOR 29.3.2. VARIATION MINIMUM CATEGORY CLASSIFICATION OF GLAZING EXPOSED SURFACE GLAZING IN STORM GLAZING IN GLAZING PANELS GLAZING PANELS GLAZING IN DOORS AND SLIDING GLASS AREA OF ONE SIDE OR COMBINATION DOORS REGULATED BY ITEM 7 REGULATED BY ITEM 6 ENCLOSURES REGULATED DOORS PATIO OF ONE LITE DOORS (CATEGORY OF SECTION R308.4.3 OF SECTION R308.4.2 BY ITEM 5 OF R308.4.5 TYPE (CATEGORY CLASS) CLASS) (CATEGORY CLASS) (CATEGORY CLASS) (CATEGORY CLASS) (CATEGORY CLASS) 9 SQ.FT. OR LESS I I NO REQUIREMENT I II II MORE THAN 9 -T II II II II II II NOTES: 1. INDIVIDUAL GLAZED AREAS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201. GLAZING SHALL COMPLY WITH THE CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR II AS INDICATED IN THE TABLE ABOVE. FOUNDATION DESIGN PARAMETERS CLASS OF MATERIAL ALOWABLE FOUNDATION LATERAL EARTH LATERAL SLIDING BEARING PRESSURE PRESSURE COEFF. OF FRICTIONA (PSF)B (PSF/FT BELOW GRADE) CRYSTALLINE BEDROCK 12,000 1,200 0.70 SEDIMENTARY AND FOLIATED ROCK 4,000 400 0.35 GRAVEL, SANDY GRAVEL (GW AND GP) 3,000 200 0.35 SAND, SILT, SILTY SAND 2,000 150 0.25 AND GRAVELS (SW,SP,SM,& GM)_ CLAY, SANDY CLAY, SILTY CLAY, CALYEY 1,500 B 100 - SILT/SAND/GRAVEL, SANDY SILT A. COEFFICIENT TO BE MULTIPLIED BY THE DEAD LOAD. B. IF SOILS ENCOUNTERED ARE EXPANSIVE, COMPRESSIBLE, SHIFTING, OR HAVE OTHER UNKNOWN CHARACTERISTICS, OR IF THE SOILS ARE ANTICIPATED TO HAVE A BEARING CAPACITY LESS THAN 1,500 PSF, A SOILS INVESTIGATION SHALL BE CONDUCTED TO VERIFY THE FOUNDATION DESIGN. C. REFER TO SOIL PROPERTIES TABLE THIS DRAWINGS FOR CLASSIFICATION OF SITE SOILS UPON FIELD VERIFICATION. D. SHADED AREAS CONSIST OF SUITABLE FOUNDATION BEARING AND BACKFILL SOILS. E. FOUNDATION DESIGN IS BASED ON SOIL CONDITIONS AND AN ALLOWABLE BEARING PRESSURE FOR ASSUMED SUBSURFACE CONDITIONS WITHOUT THE BENEFIT OF A GEOTECHNICAL REPORT OR SUBSURFACE SOIL INVESTIGATION OR ANALYSIS. IF SUBSURFACE CONDITIONS OBSERVED AT THE TIME OF CONSTRUCTION ARE NOT REPRESENTATIVE OF GW, GP, SW, SP, SM, OR GM SOILS (AS NOTED ABOVE) THEN AN ENGINEER SHALL BE CONSULTED TO VALIDATE THE DESIGN PRIOR TO CONSTRUCTION OF ANY FOUNDATION ELEMENTS.. SOIL PROPERTIES ACCORDING TO UNIFIED SOIL CLASSIFICATION SYSTEM SOIL GROUP UNIFIED SOIL CLASSIFICATION SYSTEM SYMBOL SOIL DESCRIPTION DRAINAGE CHARACTERISTICS FROST HEAVE POTENTIAL VOLUME CHANGE POTENTIAL EXPANSION GW WELL -DRAINED GRAVELS, GRAVEL -SAND MIXTURES, LITTLE OR NO FINES GOOD LOW LOW GP POORLY -GRADED GRAVELS OR GRAVEL -SAND MIXTURES, LITTLE OR NO FINES GOOD LOW LOW GROUP SW WELL -GRADED SANDS, GRAVELLY. SANDS, LITTLE OR NO FINES GOOD LOW LOW SID POORLY -GRADED SANDS OR GRAVELLY SANDS, LITTLE OR NO FINES GOOD LOW LOW GM SILTY GRAVELS, GRAVEL -SAND -SILT MIXTURES GOOD MEDIUM LOW SM SILTY SAND, SAND -SILT MIXTURES GOOD MEDIUM LOW GC CLAYEY GRAVELS, GRAVEL -SAND -CLAY MIXTURES MEDIUM MEDIUM LOW SC CLAYEY SANDS, SAND -CLAY MIXTURES MEDIUM MEDIUM LOW GROUP II ML INORGANIC SILTS AND VERY FINE SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY MEDIUM HIGH LOW CL INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS MEDIUM MEDIUM MEDIUM TO LOW CH INORGANIC CLAYS OF HIGH PLASTICITY, FAT CLAYS POOR MEDIUM HIGH GROUP III MH INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SANDY OR SILTY SOILS, ELASTIC SILTS POOR HIGH HIGH OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY POOR MEDIUM MEDIUM GROUP IV OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS UNSATISFACTORY MEDIUM HIGH Pt PEAT AND OTHER HIGHLY ORGANIC SOILS TuNSATISFACTORY MEDIUM HIGH 1. THE PERCOLATION RATE FOR GOOD DRAINAGE IS OVER 4 INCHES PER HOUR, MEDIUM DRAINAGE IS 2 TO 4 INCHES PER HOUR, AND POOR IS LESS THAN 2 INCHES PER HOUR. 2. SOILS WITH A LOW POTENTIAL EXPANSION TYPICALLY HAVE A PLASTICITY INDEX (PI) OF 0 TO 15, SOILS WITH A MEDIUM POTENTIAL EXPANSION HAVE A PI OF 10 TO 35, AND SOILS WITH A HIGH POTENTIAL EXPANSION HAVE A PI GREATER THAN 20. WALL WALL WALL WALL e 011 e e 011 4" C N U 4" C L. 4" C L. 2" C L. LAVATORIES 15" MIN. 15" MIN. WALL WALL WALL ® IW2� c c U 30" MIN. 24" CL. IN ® FRONT OF OPENING ALL WATER CLOSETS SHOWER MINIMUM FIXTURE CLEARANCES UNIFORMLY DISTRIBUTED DESIGN LIVE LOADS LOCATION LIVE LOAD (PSF) EXTERIOR BALCONIES AND DECKS 40 ATTICS SERVED WITH FIXED STAIRS 30 UNINHABITABLE ATTICS WITHOUT STORAGE 10 UNINHABITABLE ATTICS WITH LIMITED STORAGE 20 ROOMS OTHER THAN SLEEPING ROOMS 40 SLEEPING ROOMS 30 GUARD IN -FILL COMPONENTS/BALLUSTERS 50 GUARDS AND HANDRAILS 200 LB STAIRS 40 PSF/300LB TREADS GROUND SNOW SEE DESIGN CRITERIA TABLE ON DWG #1 SEISMIC DESIGN CATEGORY SEE DESIGN CRITERIA TABLE ON DWG #1 BASIC WIND SPEED SEE DESIGN CRITERIA TABLE ON DWG #1 DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. BOX 1386 Nokomis, FL 34274 (518) 742-9569 dryan@dwrpe.com STRUCTURAL ■ CIVIL ■ MUNICIPAL ENGINEERING www.dwrpe.com ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE PROJECT DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST, THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY CALL BEFORE YOU DIG WAIT THE REQUIRED TIME CONFIRM UTILITY RESPONSE RESPECT THE MARKERS DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL THE APPROPRIATE STATE DIG SAFE HOTLINE OR CALL CENTER BEFORE YOU DIG. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DRAWING STATUS: ENGINEERS STAMP: 7/18/24 REVISIONS 5 4 3 2 7/18/24 REVISED FRONT GABLE w 1 7/11/24 REVISED HIP/GABLES z PROJECT NO.: 1881 SCALE: AS NOTED w a 0 DATE: 6/19/24cc z DRAWN BY: DWRPE w cn o z PROJECT: Lu r CERRONE BUILDERS INC I- > LOT 16 VUS QUEENSBURY, NY o U = o� DRAWING TITLE a w TECHNICAL NOTES of DRAWING NO. Oz w� a ouj co z ° J � = O DWG 7 No Z U g~ CL Lu OF 7 N (L O F ,., At rn lcC . ��, 11Q INCH.