2024-0443 Docusign Envelope ID:BB2CC934-B7B6-49E9-980E-8227520E45EE
• Office Use Only
Permit If: • .011-\---oL�3 FIRE MARSHAL TENT APPLICATION
Permit Fee:
Invoice tt: Nlec to
Reviewed by:
Office of the Fire Marshal Piro Marshal
742 Bay Road,Queensbury,NY 12804
518-761-8206/8205 www.queensbury.net
NOTICE: Tent sales require Planning Board Approval
Please contact the Planning Department at least 3 months prior to the date of the sale
Project Location: Morse Athletic Complex Tax Map ID It: - ' in - 2 V (` . 1
Dates of Installation: Set up by Wednesday 10/16 end of day
CONTACT INFORMATION:PLEASE PRINT LEGIBLY OR TYPE,PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Samantha Bennett
Mailing Address,C/S/Z: Special Olympics NY 94 New Karner Road Suite 208 Albany NY 12203
Cell Phone:_( 518 ) 992-4809 Land Line:_( )
Email: sbennett@nyso.org
•Property Owner(s):
Name(s): Glens Falls School District,Kirby Girad
Mailing Address,C/S/Z: 267 Sherman Avenue,Queensbury NY 12804
Cell Phone:_( 518 )955-6505 Land Line:_(
Email: kirby@jglmcorp.com
•Tent Contractor(s):
Name(s): Entertainment 1 Rentals,Tara N
Mailing Address,C/S/Z: 433 Lower Main St,Hudson Falls,NY 12839
Cell Phone: ( ) Land Line:_( 518 )792-0929
Email: 433 Lower Main St,Hudson Falls,NY 12839
Please submit Workers' Comp documentation with this application
DECLARATION:
I acknowledge that this is not a permit but only an application for a permit and no work shall
commence prior to approval.All work will be in accordance with the approved plans and in
accordance with the Town of Queensbury and the NYS Fire and Building Codes.
If,for any reason,this application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
I have read and agree to the above:
APPLICANT NAME: Samantha Bennett
Signed by:
APPLICANT SIGNATURa tiad 4,6AAAn.J1- DATE:
2005883=55408...
PROPERTY OWNER NAME: Glens Falls School District
PROPERTY OWNER SIGNATURE: DATE: j 2
FM Tent Application Revised 3/2023
TEMPORARY STRUCTURE WORKSHEET
STEP 1
USE and OCCUPANT LOAD FACTOR(OLF)Indicate the type of use and circle the corresponding OLF. You'll use this
number in Step 2.
TENT USE OCCUPANT LOAD FACTOR/OLF(sf.ft./person)
Concentrated assembly use(chairs only,not fixed,no furniture) 7
Unconcentrated assembly(tables and chairs) 15
Standing space only assembly use(no obstructions permitted) 5
• Retail and all other uses 30
STEP 2
OCCUPANT LOAD Enter the length and width of each tent in the spaces below.Multiply these numbers to determine the total
square footage for each tent.Divide the total square footage by the OLF(Step 1)to determine the Occupant Load for each tent.
Soccer Skills Staging
Tent1 20 x 20 = 400 _ 15 = 27
Length Width Area OLF Occupant Load
Lunch
Tent 2 40 x 80 = 3,200 — 15 = 214
Length Width Area OLF Occupant Load
Young Athletes
Tent 3 20 x 20 = 400 15 = 27
Length Width Area OLF Occupant Load
Tent 4 20 20 400 15 27
Performance Stations
STEP 3 Length X Width = Area / OLF = Occupant Load
REQUIRED EXITS Using the Occupant Load(Step 2)for each tent,determine the total number of exits and minimum required
width for each exit.Please note:The key difference between a tent and a membrane structure for exiting purposes is that a
membrane structure utilizes traditional doors and door frames versus a simple opening or removal of a tent side wall panel.
Occupant Load(Step 2) Required#of Exits Minimum width of each exit(in inches)
Tent Membrane
1—9 1 72 36
10—199 2 72 36
200—499 3 72 72
500—999 4 96 72
1000—1999 5 120 96
2000—2999 6 120 96
Over 3000* 7 120* 96*
*The total width of all exits shall not be less than the total occupant load multiplied by 0.2 inches per person.
Exiting through other,nearby tents,is NOT an acceptable configuration.
FM Tent Application Revised 3/2023
STEP 4
EXITING SUMMARY Using the Occupant Load(Step 2)use the Table in Step 3 to determine the corresponding Required
Number of Exits and Minimum Width of each exit.Provide a summary of this determination below.
Tent 1
Soccer Skills Staging 2
Required#of exits Width of each exit 72
Tent 2
Lunch 72
Required#of exits 3 Width of each exit
Tent 3
Young Athletes 2 72
Required#of exits Width of each exit
Tent 4: Performance Stations 2 Required Exits Width of each exit: 72
STEP 5
FIRE EXTINGUISHERS Using the square footage of each tent(Step 2)indicate the appropriate number of fire extinguishers are
needed for each tent.
Size of Tent(sq.ft) Min.#of fire extinguishers Fire Extinguisher Summary
1—200 1 Tent 1: 2
Soccer Skills Staging
201—500 2 TentLu 2:t 5
501—1000 3 Tent 3:
Young Athletes 2
1001—3000 4 Tent 4: Performance Stations 2
3001—5000 5
5001—7000 6
7001—9000 7
9001-11000 9
Add 1 additional 2A: 10BC extinguisher for each additional 2000 sq.ft.,or fraction thereof.
STEP 6
ANCHORING Tents or membrane structures shall be designed and installed to handle the elements and prevent collapse.Please
indicate the location of all anchoring weights(minimum of 500Ibs.).
Each vertical support will be anchored with a minimum of a 500#weight.
All corners will be anchored with a minimum 500#weight.
EXAMPLE OF A 20'x 40'TENT:
0 0 0
0 0 0
500# 500#
500# 500#
500# TENT - 500#
500# 500#
500# o 0 0 500#
0 0 0
•
•
FM Tent Application Revised 3/2023