CC-0121-2023
5 , YAK Office Use Only ADDITION/ALTERATION PERMIT Permit#: C=C-- V2A, - 2cv2.,„3 Town of Queensbury APPLICATION 5�3_ Permit Fee: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensburv.net Invoice#: Flood Zone? Y N Reviewed By: I\A,c Project Location: 40 Media Dr - Travelers . Tax Map ID #: E ision Name: PROJECT INFORMATION: MAR 2023 TOWN OF QUEENSBURY BUILDING &CODESMixed Commerical Space TYPE: ❑ Residential i Commercial, Proposed Use: ❑ Single-Family ❑ Two-Family ❑ Multi-Family (#of units_) ❑ Townhouse ® Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ❑ Other (describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 15,820 sf 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total sq ft: Total sq ft: 15,820 sf Scope of work to be done: Modifications to accommodate new tenant in the building including demo, new doors, walls, finishes, plumbing, mechanical, and electrical. Addition/Alteration Application Revised June 2022 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 633,000 2. Source of Heat (circle one): ❑ Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES 0 NO Explain: 4. Are there any easements on the property? ❑ YES 0 NO SITE INFORMATION: • Is this a corner lot? ❑ YES © NO • Will the grade be changed as a result of the construction? ❑ YES • NO • What is the water source? 0 PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? © SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100% of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Cory Crane Uar,TMI,3,1Me.com,C Cory Crane ryrane O=BBL Construction Services, 3/22/23 SIGNATURE: J (late:2'023.0213:44:49-04'00' DATE: Addition/Alteration Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): BBL Construction Services (Cory Crane) Mailing Address, C/S/Z: 302 Washington Ave Ext, Albany NY 12203 Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com • Primary Owner(s): Name(s): BBL Tribune,LLC(Brandon Stabler) Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )944-0695 Land Line: ( 518 )862-9133 Email:bstabler@columbiadev.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): BBL Construction Services(Cory Crane) Contractor Trade: General Contractor Mailing Address, C/S/Z: 302 Washington Ave Ext,Albany NY 12203 Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Carry D.McClain / ME Engineering Contact Name(s): Mailing Address, C/S/Z: 2641 Irving Blvd,Dallas TX 75207 / 433 State Street 4th Floor,Schenectady,NY 12305 Cell Phone: ( ) Land Line: ( 972 )861-2296 / 518-533-2171 Email: Contact Person for Compliance in regards to this project: Cory Crane Cell Phone: ( 518 )416-2224 Land Line: ( 518 )452-8200 Email:ccrane@bblinc.com Addition/Alteration Application Revised June 2022 COMcheck Software Version 4.1.5.5 (.14. 1(1 Envelope Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Traveler's Insurance Location: Glens Falls,New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: • 40 Media Drive M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 4th Floor Schenectady, NY 12305 518-533-2171 Building Area Floor Area 1-Office:Nonresidential 15700 Envelope Assemblies Envelope TBD: No envelope assemblies specified • OF Eti, CD dssiota4- REv►EWES FAR SCE ENERGY CODE COMPLIa_.— • Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\albs_Projects\2023\23-3000\233018\Design\Desinfo\COMCHECK\233018 Traveler's Page 1 of 13 Insurance.cck • COMcheck Software Version 4.1.5.5 fit(' Interior Lighting Compliance Certificate • Project Information Energy Code: 2018 IECC Project Title: - Traveler's Insurance Project Type: Alteration • Construction Site: Owner/Agent: Designer/Contractor: • 40 Media Drive. M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 4th Floor Schenectady,NY 12305 518-533-2171 • • Allowed Interior Lighting Power A • B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Office Total Allowed Watts= N/A Area Category Exemption Qualifications • • #Fixtures Total#Watts Activity Area Pre-Alt. Repl./Added - Pre-Alt. Post-Alt. Office(15700 sq.ft.) 35000.000 35000.000 • Exemption:Replacement of bulbs and ballasts only. • Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Office(15700 sq.ft.):Exempt Linear Fluorescent 1:Other.Electronic: 2 200 ' 50 10000 Total Proposed Watts= N/A • Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designedto meet the 2018 IECC-requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. • • • Name-Title Signature Date Project Title: Traveler's Insurance • Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECIg233018 Traveler's Page 2 of 13 Insurance.cck - • AfiCOMcheck Software Version 4.1.5.5 i Mechanical Compliance Certificate Project Information • Energy Code: 2018 IECC Project Title: Traveler's Insurance Location: Glens Falls, New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 40 Media Drive M/E Engineering P.C. 1st Floor 433 State Street Queensbury, NY 12804 4th Floor Schenectady, NY 12305 518-533-2171 Mechanical Systems List Quantity System Type&Description 2 HVAC System 1 (Single Zone): Cooling:1 each-Split System,Capacity=36 kBtu/h,Air-Cooled Condenser,No Economizer,Economizer exception:None Proposed Efficiency=18.80 SEER,Required Efficiency: 13.00 SEER Fan System: AC-4,5 I First Floor VDC—Compliance(Motor nameplate HP method):Passes Fans: FAN 2 Supply,Constant Volume,920 CFM,0.1 motor nameplate hp,0.0 fan efficiency grade • Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application:The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date • Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 3 of 13 Insurance.cck COMcheck Software Version 4.1.5.5 Inspection Checklist Energy Code: 2018 IECC Requirements: 96.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section c. ,,.# Plan`Review., Complies • Comments/Assumptlons ;.;.:"`: ¢e Req.1D C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR2]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the mechanical systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable • engineering standards and handbooks. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be ONot Observable Location on plans/spec: E.20 determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and • control devices. Additional Comments/Assumptions: • 0 • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\albs_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 4 of 13 Insurance.cck • • Footing I-F94Ficiation Inspection •-;• •, - ‘_..tomnfents/Assipriturs', • &Reqmi • ; • • C403.12.2 iSnow/ice melting system and freeze 0Complies Exception: Requirement does not apply. :protection systems have sensors and Elooes Not C403:1.2.3:controls configured to limit service for • [FO9] ;pavement temperature and outdoor [Not Observable • Itemperature.future connection to ONot Applicable controls. Additional Comments/Assumptions: • • • • • • • • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Desinfo\COMCHECK\233018 Traveler's Page 5 of 13 Insurance.cck • Section .. _ # Plumb in Rough=In Ins ection -ComPes? CommentsAssum_ ptions.; &Req.ID C404:5, . !Heated water supply piping conforms ❑Complies Exception: Requirement does not apply. C404.5.1; !to pipe length and volume ❑Does Not C404.5.2 ;requirements.Refer to section details.[PL6j3' ❑Not Observable ❑Not Applicable C404.6:3 .'Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3.. !heater and storage tank have controls ❑Does Not• • !that limit operation from startup to `<= 5 minutes after end of heating ['Not Observable cycle. DNot Applicable C404.7 Demand recirculation water systems DComplies Exception: Requirement does not apply. [PL8]3 !have controls that start the pump DDoes Not -'upon receiving a signal from the :action of a user of a fixture or :Not Observable !appliance and limits the temperature ❑Not Applicable of the water entering the cold-water :piping to 104°F. ' Additional Comments/Assumptions: • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance • Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 6 of .13 Insurance.cck #q Mecha_nical Rough-In:Inspect-ion;; .Complies? Comments/Assumptions &Re .ID C402.2.6 ;Thermally ineffective panel surfaces of OComplies Exception: Requirement does not apply. [ME41]3 :sensible heating panels have ODoes Not insulation >= R-3.5. ['Not Observable ONot Applicable C463:11.3 HVAC piping insulation insulated in ❑Complies Requirement will be met. [ME6112 accordance with Table C403.11.3. ODoes Not Insulation exposed to weather is Location on plans/spec: MO.2, MO.3 `protected from damage and is ❑Not Observable • • .provided with shielding from solar DNot Applicable ;radiation. `C403.8.4 Motors for fans that are not less than ❑Complies Requirement will be met. [ME142]2 :1/12 hp and less than 1 hp are ODoes Not ;electronically commutated motors or have a minimum motor efficiency of ['Not Observable 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. `C403.8.5 ;Each DX cooling system > 65 kBtu OComplies Exception: Requirement does not apply. [ME143]2 ;and chiller water/evaporative cooling ODoes Not !system with fans> 1/4 hp are ❑Not Observable Location on plans/spec: Existing systems>65kBtu are to !designed to vary the indoor fan airflow remain in place. as a function of load and comply with DNot Applicable detailed requirements of this section. C403.12.11Systems that heat outside the building ❑Complies Exception: Requirement does not apply. [ME71]2 •.. envelope are radiant heat systems ODoes Not • : ;controlled by an occupancy sensing ;device or timer switch. Not Observable DNot Applicable C403.2.3 ;HVAC equipment efficiency verified. OComplies See the Mechanical Systems list for values. [ME55]2 ! DDoes Not ❑Not Observable • ❑Not Applicable C403.2.2 ;Natural or mechanical ventilation is OComplies Requirement will be met. [ME5931 ;provided in accordance with ODoes Not • International Mechanical Code ;Chapter 4. Mechanical ventilation has ['Not Observable capability to reduce outdoor air supply DNot Applicable to minimum per IMC Chapter 4. C403.7.1 Demand control ventilation provided DComplies . Exception: Requirement does not apply. [ME59]1 for spaces >500 ft2 and >25 ODoes Not people/1000 ft2 occupant density and served by systems with air side Not Observable economizer,auto modulating outside DNot Applicable air damper control, or design airflow >3,000 cfm. . C403.7.2 ;Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. [ME115]3 :has automatic contaminant detection ODoes Not • • ;and capacity to stage or modulate ;fans to 50%or less of design capacity. ['Not Observable DNot Applicable C403.7.6 HVAC systems serving guestrooms in OComplies Exception: Requirement does not apply. [ME141]3 Group R-1 buildings with >50 ODoes Not guestrooms: Each guestroom is • provided with•controls that ❑Not Observable :automatically manage temperature DNot.Applicable . setpoint and ventilation(see sections C403.7.6.1 and C403.7.6.2). C403.7.4 Exhaust air energy recovery on ❑Complies Exception:Requirement does not apply. [ME57]1 systems meeting Table C403.7.4(1) DDoes Not • and C403.7.4(2). :Not Observable DNot Applicable • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 7 of 13 Insurance.cck ' 1 • Section # Mechanical Rough-In Inspection ,.~`..Complies?& • ;-.Comments/AssumP tions.Re .ID q C403.7.5 iKitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply. [ME116]3;I replacement air and conditioned DDoes Not ;supply air limitations,and satisfy hood rating requirements and maximum ❑Not Observable exhaust rate criteria. ONot Applicable • C403.11.1 HVAC ducts and plenums insulated in..❑Complies Exception: Requirement does not apply. accordance with C403.11.1 and ❑Does Not C403.11.2.constructed in accordance with [ME60]2 C403.11.2,verification may need to ONot Observable occur during Foundation Inspection. ONot Applicable C403.4.1. ;Heating for vestibules and air curtains ❑Complies Exception: Requirement does not apply. 4 :with integral heating include ODoes Not [ME63]z :automatic controls that shut off the heating system when outdoor air ONot Observable temperatures>45F.Vestibule ❑Not Applicable heating and cooling systems • !controlled by a thermostat in the ;vestibule with heating setpoint<= • 60F and cooling setpoint>=80F. C403.3.3 Hot gas bypass limited to: <=240 ❑Complies Requirement will be met. [ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not ❑Not Observable Location on plans/spec: MO.6-No hot gas bypass specified. System is capable of continuous capacity modulation. ❑Not Applicable C408.2:2. ;Air outlets and zone terminal devices ❑Complies Requirement will be met. ' 1 • I have means for air balancing. ❑Does Not [ME53]3 ['Not Observable ❑Not Applicable C403.5, ;Refrigerated display cases,walk-in ❑Complies Exception: Requirement does not apply. C403.5.1,. !coolers or walk-in freezers served by ❑Does Not C403.5.2 ;remote compressors and remote [ME123]3 I condensers not located in a ❑Not Observable • condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.: Additional Comments/Assumptions: • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:. Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\DesInfo\COMCHECK\233018 Traveler's Page 8 of 13 Insurance.cck . . . ` omp C405.2.2. Spaces required to have light- ElComplies Exception: Daylight spaces that comply with this code, o reduction contmbhaveamanual []ouesmvt [sL22]1 control that allows the occupant u, L]mo�Obsemab|e Location oopKan�ypec: so'o reducetheconnecoed|ighting|uadin a reasonably uniform illumination []mot Applicable pattern>~ sopercent. c405.2.1. Occupancy sensors installed in []Complies Exception:Automatic-on controls are allowed incorridors, C405.2.1. classrooms/lecture/training moms. []Does Not stairways, sstmoms'phmary'bui|dino entrance areas and z conference/meeting/multipurpose lobbies,and aeasWhere manual-on cvntm|scould impact [sL18}1 �moms'copy/print moms' []mc�Obsemab|e safety-rsecuhtv |nunges/bneakmnms.endusedn��ces' []Notxpp|icaWe ' open plan office areas, nstmvms. Location wupUans/spec: E2.0 -storage rooms, locker rooms, � :warehouse storage areas,and other spaces==sousqft that are enclosed byflonpto'cei ling height partitions. Reference section language C4os.a.1.o for control function in warehouses and section C4Vs.z.z.s mropen plan office spaces. C405.2.1. Occupancy sensors control function in []complies Exception:Requirement does not apply. o wanehouses: |n warehouses,the []Does Not [sLle]z lighting inais|eways and open areas is Location wn�Xao��pw�: so'o contmKedwith occupant sensnothat []Not Observable automaUcaUyreduce|�htingpower []Not Applicable by50Y6or more when the areas a[e unoccupied.The occupant sensors control lighting in each aisleway independently and do not control .lighting beyond the a|s|ewaybeing controlled by the sensor. c405.2.1. Occupant sensor control function in LJCvmplies Requirement will bemet. 3 open plan office areas: Occupant []Does Not [sL20]1 sensor controls in open office spaces Lp��tiwu�u�Xao�����: soo >= 3O�sq.ft. haVecuntm|sz} [:]Not Observable ' �� |i b| configured []m lighting o«'*op ca e ue controlled separately incontrol ' zones with floor areas <= 600 sq.ft. within,the space, off generallighting in allcontrol zones within 2o minutes after all occupants have left the space,s)are configured _ —at_~_--'~'—~ power in each control zone is reduced the full zone general lighting power within 2o minutes or 611 occupants leaving— -~^^~~~~~.`~~-,..~ configured" spaceresponsive control will activate general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2� Each area not served Exception: Lighting controlled byoccupancy sensors. c405.12. :sensors(per c4os.a.z)have time- []ovesmct z. :switch controls and functions detailed Location on plans/spec: E2.0 C405.2.2. Hn sections c*05.2.2.1 and c405.2.3.2. []Not Observable 2 []mntApp|icabie sLaz12 | ' ) , � z High Impact(rierl) o Medium Impact(rierz) 3. Low Impact(Tlera) Project Title: Traveler's Insurance Report date: V]/ n/os Data filename: nfo\COMCHscm233VzD-rrave|ers Page .gof 13 Section oa hIn Elect`i•�`a 'r c I Ins` action- .�' -:Com"lies. Comments/Assumptions &`RegID. C405.2.3, Daylight zones provided with DComplies Requirement will be met. C405.2;3. ;individual controls that control the ODoes Not 1, lights independent of general area Location on plans/spec: E2.0 C405:2:3. ;lighting. See code section C405.2.3 ONot Observable 2:' !Daylight-responsive controls.for ONot Applicable [EL23]Z ;applicable spaces,C405.2.3.1 Daylight • ;responsive control function and ;section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for DComplies Requirement will be met. [EL26]1 specific uses installed per approved ODoes Not lighting plans. Location on plans/spec: E2.0 ONot Observable ❑Not Applicable C405.2.4 ;Additional interior lighting power DComplies Requirement will be met. [EL27]1 allowed for special functions per the ODoes Not ;approved lighting plans and is ❑Not Observable Location on plans/spec: E2.0 ;automatically controlled and separated from general lighting. ONot Applicable C405.3 Exit signs do not exceed 5 watts per DComplies Requirement will be met. [EL6]1 face. DDoes Not ['Not Observable Location on plans/spec: E7:0 DNot Applicable C405.6 ;Low-voltage dry-type distribution DComplies Requirement will be met. ,[EL26j2 !electric transformers meet the ODoes Not ;minimum efficiency requirements of ;Table C405.6. ['Not Observable ONot Applicable C405.7 Electric motors meet the minimum DComplies Requirement will be met. [EL27]z. ;efficiency requirements of Tables ODoes Not ;C405.7(1)through C405.7(4). :Efficiency verified through certification [Not Observable under an approved certification ONot Applicable program or the equipment efficiency ;ratings shall be provided by motor . .,manufacturer(where certification programs do not exist). C405.8.2, ;Escalators and moving walks comply DComplies C405.8.2. 'with ASME A17.1/CSA B44 and have ODoes Not 1. automatic controls configured to [EL2812 reduce speed to the minimum [Not Observable !permitted speed in accordance with ONot Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. • C405:9 ;Total voltage drop across the DComplies Requirement will be met. [EL29]2 ;combination of feeders and branch ❑Does Not ;circuits<= 5%. ['Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 10 of 13 Insurance.cck • • "Section - _ #• Final Inspection. Complies? - Comments/Assumptions• &Reg ID ": , Furnished O&M instructions for ❑Complies Requirement will be met. C408.2;5: systems and equipment to the ❑Does Not 2,;; .._. ;building owner or designated [FI17]3 rrepresentative. ['Not Observable • ❑Not Applicable C303.3, I Furnished O&M-manuals for HVAC ❑Complies Requirement will be met. C408`2.5: systems within 90 days of system ODoes Not 3; 'acceptance. ❑Not Observable [FI8]3". ❑Not Applicable C403-2.2 HVAC systems and equipment DComplies Exception: Multiple units of the same type of equipment with [F127.]3.: ° 'capacity does not exceed calculated ❑Does Not sequencing controls. ;loads. ENot Observable ❑Not Applicable C403.2:4:;Heating and cooling to each zone is DComplies Requirement will be met. ;controlled by a thermostat control. ❑Does Not [FI47]3 " !Minimum one humidity control device Location on plans/spec: M2.0 ;per installed ['Not Observable humidification/dehumidification ONot Applicable system. • .C403.41"r' Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 2 ' deadband. ['Does Not [FI38]3 ❑Not Observable ❑Not Applicable C403:2i4.: ;Temperature controls have setpoint DComplies Requirement will be met. 13• : ;overlap restrictions. ❑Does Not [FI20]3: ['Not Observable ❑Not Applicable C403.2.4, !Each zone equipped with setback DComplies Requirement will be met. 2 controls using automatic time clock or ❑Does Not [FI39]3 programmable control system. ['Not Observable • ❑Not Applicable C403.2:4. ;Automatic Controls:Setback to 55°F DComplies Exception: Requirement does not apply. 21, I(heat)and 85°F(cool); 7-day clock,2- ElDoes Not C403.2.4. 1 hour occupant override, 10-hour Not Observable 2:2 backup [F140]3. ❑Not Applicable C403.2.4: ;Systems include optimum start DComplies Exception: Requirement does not apply. 2:3. controls. ❑Does Not [FI41j3 ❑Not Observable ❑Not Applicable C405.4.1 Interior•installed lamp and fixture DComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting ['Not Observable plans,demonstrating proposed watts ❑Not Applicable are less than or equal to allowed pP icable watts. • C408.1.1 Building operations and maintenance DComplies [FI57]1 documents will be provided to the DDoes Not owner. Documents will cover manufacturers'information, ❑Not Observable specifications, programming ❑Not Applicable procedures and means of illustrating to owner how building,equipment and systems are intended to be installed, maintained, and operated. • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\Deslnfo\COMCHECK\233018 Traveler's Page 11 of 13 Insurance.cck , . ` » ^ . ion ,, [408.2.1 ':Commissioning plan developed by ElComplies Requirement will bemet. [F12811 registered design professional or []Does Not approved agency. LJNotObsemab|e []mctxpp|icab|e c4082.3. HVAc equipment has been tested u, ElComplies Requirement will bemet. l ensure proper operatiun. []Does Not [F|3l]z � LJwotmbsenvable []mctxppUcab|e C408.2.3. !HvAc control systems have been []Complies Requirement will bemet. 2 !tested u,ensure proper operation, []ovesmot [RzV]z |ca|ibrmjonandacUustme,tofcon�o|s ' ' []Notobsemab|e | []wntApplicable c4oa.Z.0 Preliminarynepo� []complies Requirement wiUbemet. [RzoIz completed and certified bvregistered []Does mot design professional orapproved LJmotobsemab|e agency. []Notxpp|icab|e Furnished MvAc as-built drawings []Complies Requirement will bemet. submitted within 9O days ofsystem []Does mot IF17]3,: !acceptance. ] LJNotObsenab|e ' []NotAppUcaWe ` |Furnished as-built drawings for ElComplies Requirement will bemet. . |e ectric power systems within qodays []ooe°mvt � cf system acceptance. []mctobsemab|e ONot Applicable C408.2.5. 'An air and/or hydronic system ElComplies Requirement will bemet. 3 balancing report m provided for HVxc LJovesmot [p143]1 systems. [-]Not Observable ' LJwotxpp|icab|e C408.2.5. 'Final commissioning report due to []cump|is Requirement will be met. 4 |building owner within 90 days of []ooeswvt [p80]1 receipt nf certificate ofoccupancy. ! LJNutObservable . � E]mvtxppicaWe C408.3 Lighting systems have been tested to OComplies Requirement will bemet. � [p133]1 ensure proper calibration,adjustment, []ooe,m,t programming,and operation .. []mctobsemab|e � []Not Applicable ' Additional Comments/Assumptions: ' ` l High Impact(Tier 1) Z Medium Impact(Tier 3) s Low Impact(Tier s) Project Title: Traveler's Insurance Report date: O3/30/2s Data fi|enamei Va|bafl|eua|ba_pn4ects\ uo3\23'aoVm233ol8y»esign\oes|nfo\cmMCHeCm23so10—Trameler's Page zoof 13 msu,ance.cck ` • • Project Title: Traveler's Insurance Report date: 03/30/23 Data filename: \\albafilel\alba_Projects\2023\23-3000\233018\Design\DesInfo\COMCHECK\233018 Traveler's Page 13 of 13 Insurance.cck BB � o n BBL Construction Services, LLC Phone 518 452-8200 Services 302 Washington Avenue Ext. Fax 518 452-2897 Albany, New York 12203 April 10, 2023 Town of Queensbury Building Department 742 Bay Road Queensbury, NY 12804 • Attn: Mark Smith Re: Building Permit Application- CC0121-2023-Air Balancing Dear Mark, • This letter shall serve as our letter of intent to perform air balancing before the end of the project as both a project and town requirement. The contractor that will be performing this scope is yet to be determined, however, upon selection of a contractor, their information will be shared with the Town of Queensbury Building Department. I hope this letter will provide the commitment you require to issue a building permit and that the contractor name can be provided upon scope award. Sincerely, —DocuSigned by: "-9EF9B4169F194A1... Cory Crane Project Manager 101111111k FIRE MARSHAL'S OFFICE w 1 Town of Queensbury f 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Travelers /BBL CC-0121-2023 3/24/2023 15,820 sf, Floor 1 The following comments are based on a review of submittals: • Verify fire extinguisher location and inspection • Verify paths of egress • CO detection is required • Locks /Latches to comply with Chapter 10 of IFC • Provide Knox Box and entry key for FD • Function test exit/El lighting, • Contractors shall follow all guidelines in Fire Code Chapter 33, for protection of fire and life safety devices, during construction • NFPA 72 letter of compliance required for any changes or alterations to the fire alarm system • NFPA 13 letter of compliance required for any changes or alterations to the sprinkler system ,t\i,\N„,e .--sillE Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office a Phone: 518-761-8206 a Fax: 518-745-4437 firemarshal@queensbury.net . www.queensbuly.net