Loading...
1.1 1.1 WASTEWATER-SEWER\SetPI-Nomer-Replacement Components—Setbacks-Parking Under Driveway-Share Absorption W/DiMartmo Neighboring Property—ETU-10-7-2024 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF STEVE JOINER RESOLUTION NO.: ,2024 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS,the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, Steve Joiner,on behalf of the Margaret P.Berrigan Revocable Trust,(Applicant) has applied to the Local Board of Health for variances from Chapter 136 for installation of a replacement wastewater treatment system (System)to be located on 99 Birdsall Road in the Town of Queensbury, with installation of the proposed System's absorption field to be located on adjacent property owner Domenick DiMartino's parcel located at 97 Birdsall Road as will be described in an easement to be provided with the System permit application if the requested System variances are approved, and WHEREAS, Applicant has requested variances for the System components to be located as follows: 1. ETU/Pump Station to be located 34' from Applicant's well in lieu of the required 50' setback; 2. ETU/Pump Station to be located 40' from DiMartino's well to the north in lieu of the required 50' setback; 3. ETU/Pump Station to be located 25' from the Gwinup property's well to the south in lieu of the required 50' setback; 4. ETU/Pump Station to be located 1' from the structure (crawl space to the north) in lieu of the required 10' setback; 5. Force main to be located 9' from the south property line in lieu of the required 10' setback; 6. Absorption field to be located 46' from Applicant's well in lieu of the required 100' setback; 7. Absorption field to be located 55' from DiMartino's well to the north in lieu of the required 100' setback; 8. Absorption field to be located 90' from the Gwinup property's well to the south in lieu of the required 100' setback; 9. Absorption field to be located 9' from the south property line in lieu of the required 10' setback; 10. Absorption field to be located 4' from the west property line in lieu of the required 10' setback; and 11. Absorption field to be installed under the driveway; NOW, THEREFORE, BE IT RESOLVED,that the Town of Queensbury Local Board of Health will hold a public hearing on Monday, October 21", 2024 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider Steve Joiner's sewage disposal variance application concerning property located at 99 Birdsall Road in the Town of Queensbury(Tax Map No.: 289.17-1-36) and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500 feet of the property as required by law. Duly adopted this 7 h day of October, 2024,by the following vote: AYES NOES ABSENT: MAGNETIC REACTION UNDER PAVEMENT LANDS NIF OF 794 STATE ROUTE 149, LLC 289.17-1-1.2 DRY STACKED "ONCRETE BLOCK RETAINING WALL 1-114"IPF S46.14'W, 0.68' From Corner LANDS NIF OF STUART ALAN 289.17-1-54 IAIA CTCIAIATCD CVCTCM Of A At GRAPHIC SCALE 15 0 8 15 30 60 (IN FEET) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. Glen Tie Line 54'f Along Shore 3/4" IPF N49-25'15"W, 0.25' From Corner Lake e0 cFalc o \ o � a} ,o ILYETHYLENE��g',�G�j USED AS LANDS NIF OF MARGARET P.BERRIGAN REVOCABLE TRUST 289.17-1-36 0kA- C� \ fat \ LANDS NIF OF DANIEL & KATHRYN GWINUP 289.17-1-37 SYSTEM INSTALLATION NOTES SEPTIC VARIANCE SUMMARY 1. ETU/ PUMP STATION TO WELLS 50' REQUIRED 34' PROPOSED FROM OWN WELL 16' OF RELIEF REQUESTED 40' FROM DIMAR77NO WELL TO THE NORTH IO' OF RELIEF REQUESTED 25' PROPOSED FROM GWINUP WELL TO THE SOUTH 25' OF RELIEF REQUESTED 2. ETU / PUMP STATION TO STRUCTURE 10' REQUIRED I' PROPOSED FROM CRAWL SPACE TO THE NORTH 9' OF RELIEF REQUESTED 3. FORCE MAIN TO PROPERTY LINE 10' REQUIRED 9' PROPOSED FROM SOUTH PROPERTY LINE 1' OF RELIEF REQUESTED 4. ABSORPTION FIELD TO WELLS 100' REQUIRED 46' FROM OWN WELL 54' OF RELIEF REQUESTED 55' FROM DIMARTINO WELL TO THE NORTH 45' OF RELIEF REQUESTED 90' FROM GWINUP WELL TO THE SOUTH 10' OF RELIEF REQUESTED 5. ABSORPTION FIELD TO PROPERTY LINES 10' REQUIRED 9' FROM SOUTH PROPERTY LINE 1' OF RELIEF REQUESTED 4' FROM WEST PROPERTY LINE 6' OF RELIEF REQUESTED 6. ABSORPTION FIELD TO BE INSTALLED UNDER THE DRIVEWAY U.V. DISINFECTION TO BE INSTALLED ON JOINER. DIMARTINO & BIRDSALL, LLC PARCEL WELLS CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. AFTER EXCAVA71ON OF THE ABSORPTION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF THE BED SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. PLACEMENT OF OPEN -BOTTOM GRAVELLESS CHAMBERS SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE ABSORPTION BED. OPEN -BOTTOM GRAVELLESS CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE CHAMBERS SHOULD BE LAID AS INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR 07HER UNSUITABLE CONDITIONS. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONS 34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY. ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FORCEMAIN PIPING TO BE 1-1/2" SDR-11 HDPE, OR SCHEDULE 40 PVC PRESSURE PIPE. PROVIDE POSITIVE DRAINBACK TO PUMP STATION. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 Pvc. INSTALL WITH 1/4" PER FOOT kA f crr= i nrATTnAl LOGATION MAP WASTEWATER SYSTEM DESIGN 2-BEDROOM RESIDENCE DESIGN FLOW - 110 GPD/ROOM SYSTEM DESIGN FLOW - 220 GPD SEPTIC TANK - PROP. FUJICLEAN CE-5 ENHANCED TREATMENT SYSTEM PUMP STA77ON - EX. 500 GALLON POLYETHYLENE PUMP TANK LEACH FIELD - SUB PARKING AREA ABSORPTION BED W/34" WIDE TRAFFIC RATED OPEN -BOTTOM GRAVELLESS CHAMBERS DESIGN PERCOLATION RATE = 1-5 MIN/IN APPLICATION RATE = 0.95 GPD/SF ABSORPTION AREA REQUIRED = 220 GPD/0.95 GPD/SF = 232 SF INSTALL 15'x2O' ABSORPTION BED = 300 SF W/(3) LATERALS OF (2) INFILTRATOR H-20 CHAMBERS POTABLE WATER SUPPLY IS TO BE ON -SITE WELL MINIMUM SLOPE. MAP REFERENCE: STABILIZATION FABRIC GEOTEXTILE WITH POLYPROPYLENE 1. BASE MAP INFORMATION FROM ''SURVEY LANDS OF STEVEN STABILIZATION FABRIC TO BE WOVEN HIGHWA)T JOINER & THE MARGAREI P. LTNIGAN REVOCABLE TRUST," YARNS, 1HRACE LINQ G7F-300 OR EQUIVALEN IN THE TOWN OF QUEENSBUR�WARREN COUNTY NEW YORK. DATED MAY 28, 2024.' PREPARED BY GILBERY SEPARATION FABRIC 'OTEXTILESEPARATION FABRIC, TC VANGUILDER LAND SURVEYOR, PLLC.. STABILIZATION FABRIC TO BE NON -WOVEN GE 2. WESTERLY NEIGHBOR PROPERTY' INFORMATION FROM "MAP MARAFI 140N OR EQUIVALENT. OF A TOPOGRAPHIC SURVEY MADE FOR DOMENIC & KATHLEEN P DIMARTINO-" IN Tt 0 50 E TOWN OF QUEENSBURY, SEPTIC TANK 10' 10' 5 Dig % Safely. New ®York Call Before You Dig Wait The Required Time ConfirmUtility Response Respect The Marks Dig With Care 800-962.7962w www.digoafelyneyork.com d- o N Of o C) U 2 v W .O N ct o W o z ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Havi/and Road Queensbury, NY 12004 (518) 745.0307 Phone (518) 745.0308 Fax G. THOMAS HUTCHINS, P.E. THOMAS R. CENTER, JR. P.E. LUCAS W. DOBIE, P.E. TAX MAP # 289.17-1.36 WASTEWATER SYSTEM PLAN prepared for: Steve Joiner 99 Birdsall Road Town of Queensbury County of Warren State of New York Drawn: HKB Checked: MC Scale: 1" - 1s' Date: 9/3/2024 2923504141 114" PER FOOT MIN. SLOPE D/ll VCTIJVI LAIC CVTCAI Cl/1Al NSF-40 ENHANCED TREATMENT UNIT TANK FUJICLEAN CE5 FUJICLEAN ETU STATION DETAIL NTS 1 1/2' TOP COURSE ASPHALT 2" BINDER COURSE ASPHALT GRANULAR SUBBASE COURSE NYS DOT SECT. 304. TYPE 2 OR 4 COMPACTED TO 95% STD. PROCTOR ASPHALT PAVEMENT DETAIL NTS 18" MINIMUM D.O.T. GRAVEL STABILIZATION GEOGRID 6" ABOVE SYSTEM STONE, 12" MIN. GRAVEL SUBBASE OVER BED AREA EXTENDING 1' BEYOND EDGES OF STONE BASE COURSE 1' 15' BED WIDTH 1' 4' TYP. SPACING �I 'VAVAV�►VAV� �i W,!�i VAVAVAVAVAVAVAVAVAVAVAVAVAVAVAVA�IAVAVAVAVAVAVAVAVAVAVAV.i�VAVAVAVi�\VA�Ia�V.AVAVAV i�i �i i�i'•�i i�i i�i i�i i�ly �i �i:�i;�i i�%;�i,�i � �'i i� A :. L-7�L��rl�ArL��YLa►�rI1���YaeLa�L1�LLD�rL����ISW a �. - Imo—wip—.iti[�— �— ABSORPTION FIELD SECTION NTS M ui I— N BBI� B 1 BB�>>••B��>• i1i�0a�� B��t•����IBti ����� '�oil, ���millm ��� �l�o� �weMINE 1111 1�1�1�1� z INFILTRATOR H-20 CHAMBER PROFILE NTS FLOAT SWITCHES - INSTALL INSIDE PUMP PIT IN LOCATION ACCESSIBLE WITHOUT PIT ENTRY — 34" CHAMBER MD 7H —�' ` INFIL TRA TOR H-20 CHAMBER SECTION N TS iMBER qT EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. POLYETHYLENE EXTENSION 500 GALLON POLYETHYLENE PUMP STATION INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED TRANSITION TO 4" OUTSIDE OF D-BOX 1-1/2" SCH-40 PVC PIPING INSIDE WET WELL THROUGH WALL REDUCING TEE POINTED DOWNWARD WITH 1" BALL VALVE THROTTLED TO ALLOW TRICKLE DRAIN BACK INTO WETWELL UNION - LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PUMP REMOVED WITHOUT TANK ENTRY BALL CHECK VALVE GOULDS WE05H PUMP ASPHALT PAVEMENT dAhhLt USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 4" PVC SDR-35 SOLID HEADER TO ABSORPTION LATERALS, 118" PER FOOT MIN SLOPE TRAFFIC -RATED CAST IRON MANHOLE COVER 30" INSIDE DIAMETER CONCRETE RISER RING INSTALL 2" RIGID POLYSTYRENE INSULATION BOARD OVER DISTRIBUTION BOX Dig P Safely. New®York ■ Call Before You Dig N Walt The Required Time Confirm Utility Response ■ Respect The Marks Dig WHh Care 800-962.7962 wwwAigsafelynewyork.com PUMP STATION DETAIL z NTS SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. AFTER EXCAVATION OF THE ABSORPTION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF THE BED SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. PLACEMENT OF OPEN -BOTTOM GRAVELLESS CHAMBERS SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE ABSORPTION BED. OPEN -BOTTOM GRAVELLESS CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE CHAMBERS SHOULD BE LAID AS INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS OR OTHER UNSUITABLE CONDITIONS. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. PUMP STATION NOTES PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, DEMAND DOSE CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION. INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS. PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO PROVIDE A 50 GALLON DOSE. EFFLUENT PUMPS TO BE GOULDS PUMPS WE SERIES, MODEL WE05H SUBMERSIBLE EFFLUENT PUMP .5 HP, 230 VOLT, 1PH OR APPROVED EQUIVALENT VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. SYSTEM MATERIAL SPECIFICATIONS 34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY. ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FORCEMAIN PIPING TO BE 1-112" SDR-11 HDPE, OR SCHEDULE 40 PVC PRESSURE PIPE. PROVIDE POS171VE DRAINBACK TO PUMP aTA110N. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. STABILIZATION FABRIC 4WAY GEOTEXPLE WITH POLYPROPYLENE STABILIZATION FABRIC TO BE WOVEN HIGIALENT. YARNS, THRACE LINQ GTF-300 OR EQUIV SEPARATION FABRIC ' GEOTEXTILESEPARA71ON FABRIC, TC STABILIZATION FABRIC TO BE NON -WOVE MARAFI 140N OR EQUIVALENT. SCUM BAFFLES B 4" INLET PIPE,.. l INLET / BAFFLE RECIRCULATION PIPE - FLOW OPENING (TYP. J' 20" AC N ��� per! � • I • >'�t•lo LFLOW BAFFLE O-I �3/4" AIR INTAKE (CLEANING OPENING) SECTION A -A VIEW . •• 1.-. j�' - •• . . .- i•�f:� " - - • • • ucil •: . . • �. �J�a1�•Z�f[• -•. -► -- ACCESS COVER p) NFECTION INDER (OP SECTION B-B VIEW FUJICLEAN CE-5 ETU DETAILS NTS ACCESS COVER W OPENING �RD TYPE ITACT MEDIA 'IRCULATION LIFT PUMP 'OBIC MEDIA 'ATION ASSEMBLY ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC 169 Haviland Road Queensbury, NY 12804 (518) 745.0307 Phone (518) 745.0300 Fax C. THOMAS HUTCHINS, P.E. THOMAS R. CENTER, JR. P.E. LUCAS W. DOB►E, P.E. TAX MAP # 289.17-1-36 WASTEWATER SYSTEM PLAN prepared for: Steve Joiner 99 Birdsall Road Town of Queensbury County of Warren State of New York Drawn: HKB Checked: TRC Scale: 1"- 15' Date: 0/3/2024 23504142