Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-0330-2022
Office Use Only PRINCIPLE STRUCTURE PERMIT APPLICATION Permit#: CC - O 3w0 2022 Permit Fee:$ • h5 Town ofQueensbury 742 Bay Road,Queensbury, NY 12804 *Rec Fee:$ 1•11f�e' �pYQV .d1N�A‘i P: 518-761-8256 www.queensburynet Invoice#: itDC00 L Flood Zone? Y N Reviewed By: Project Location: 2 10 ii'1 '1SrcA VY Tax Map #: 309.10-1-60 Subdivision Name: *TOWN BD.RESOLUTION 385-2020:$1000 recreation fee for new dwelling units:single family,duplexes/two-family, multiple family, apartments,condominiums, townhouses,and/or manufactured & modular homes,but not mobile homes. This is in addition to the permit fee(s). PROJECT INFORMATION: Residential X Commercial, Proposed Use: Multi-family residential apartments Single-Family: _Two-Family X Multi-Family(#of units: 6 ) 1. Custom 2. _Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) X Townhouse 6 Garage (#of cars 1 ) _Business Office Retail _Hotel/Motel Industrial Heated Warehouse/Storage Building _Unheated Warehouse/Storage Building Amusement Ride _Other(describe: MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1ST floor: 1,360 SF 1ST floor: 3,563 SF 2nd floor: 5,016 SF 2"d floor: NA 3rd floor: NA Total square feet: 1,360 SF Basement(habitable space): NA Total square feet: 8,579 SF Principle Structure Packet Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 850,000 2. Proposed use of the building: Multi-family residential apartments 3. If Commercial or Industrial, indicate the name of the business: Mountain Vista Apartments 4. Source of Heat: X Gas Oil Propane Solar _Other: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES X NO Explain, if yes: 6. Are there any easements on the property? X YES _NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? 1.04 acres b. Is this a corner lot? YES x NO c. Will the grade be changed as a result of the construction? _YES X NO d. What is the water source? x PUBLIC PRIVATE WELL e. What type of wastewater system is on the parcel? X SEWER PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ethan P. Hall -ArchitectWgent for the Applicant SIGNATURE: DATE: 25 May 2022 Principle Structure Packet Revised January 2021 r CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Schermerhorn Properties Mailing Address, C/S/Z: 356 Bay Road Suite 2, Queensbury NY 12804 Cell Phone: ( ) Land Line: ( 518 )792-0674 Email: rschermerhornaschermerhornproperties.com • Primary Owner(s): Name(s): Schermerhorn Properties Mailing Address, C/S/Z: 356 Bay Road Suite 2, Queensbury NY 12804 Cell Phone: ( ) Land Line: ( 518 )792-0674 Email: rschermerhorn@schermerhornproperties.com 12 Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): Schermerhorn Properties Contractor Trade: General Construction Mailing Address, C/S/Z: 356 Bay Road Suite 2, Queensbury NY 12804 Cell Phone: ( ) Land Line: ( 518 )792-0674 Email:rschermerhorn@schermerhornproperties.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Engineer(s): Business Name: Rucinski Hall Architecture Contact Name(s): Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: ( 518 )260-2888 Land Line: (518 )741-0268 Email:ephall@nycap.rr.com Contact Person for Compliance in regards to this project: Ethan P. Hall Cell Phone: ( 518 )260-2888 Land Line: ( 518 )741-0268 Email: ephall@nycap.rr.com Principle Structure Packet Revised January 2021 - J•tir:.... ,-.i.ta.. ,. _• c HAANEN ENGINEERING Job No I boSS Sheet No. 1 of •" Subject: RNA Associoks Town hoi se, A pan-4-rnr, i- eu i 12,i ut By NSGr Date o5/2.4I lECEOVE ;\ 1' RauFDe.d Loa _ MAY 2 7 2022 .2) a ReoF f7s+SSes x TOWN OF QUEENSBURY - j°psF BUILDING&CODES --) Shea-411.5 b A psP ._-, Pl 11ate+icc-I f Fh efr cwii 1)aaw,bi►"-i 3 psP TO Rc F l eiari Loa.1 , I7-psF ~~�'\ Z) RooF Emu.) Log4dr' GC NYS I 6 it) o ���E © � --e 3,1,old slid 0 (pwa Pb, 50 Rs F --b' F.LJ- P sr,utii lockJ Pp t• G.4-• cc• 4.•1 • Gih al Eg poStAtt 1&th'r Frr t'n -ct sr4 - i3 g parli.ab wo a posed ?noP * z m. 0 ►•o C Tilde- I .3. g) d = x 1.0 eTcaWC ig0t•3 •mil �`I e �\ .,�r _ .2 ir, , t:.it N m O I. +, C v (1) A �dicc�u c ��c l'w o.61241 • ��= 04 w = I,.® Tc �� ESS 6. W C (604, s-j N k.0 . N ' Pao pp v 0.7 Cy • ce • 7. • 4 s G.7-x t•ox l.o x i.e.X goPO', ` N 15 frr 254 Bay Rd - Queensbury,NY 12804- Phone:S18-793-7444- Fax:91B-793-7061- Email:hiht hlhlic.com HAANEN ENGINEERING Job No -I 6055 Sheet No. 2 of '5-- subject: RHA ,ssoc.ic -es By PIS 4 Date o5 12.4 s,)oped v1;10 f slow A04 A 11 P Cs• bP Roo F slope. �s: ►2 Fey uvib J-e4 5 e p 90'ru as to I ft',�A For wv,vta •d eil o P a� IZ .Zo (air vern4,'A.4•e.d oP J Cs o 0. 6. Far oLl o4sv rrPtces , Cs - o,q*S kerICL.) Cori Wina4- cake Cs 6 3' • •,, Duped Tut* Sna-r .10.a ps . Cz.• Pp : @. 9i5'x35 = 34•1 pIP 44 85psF lejorynivve, fuvlbeiAncej sinDt4 1o4a ( ASCg 4--oS F.(pre 4.SJ I : 5Ps e.3ks 6. 3x3s a to.SpsP L_---_ r- c. I a• , 4- 14 — o2 0•SpS s= I..� ; JL4.= s��_ tik= 21 12 t d' r x2aS 33. SpsF 84. h�• � 2,e III = F� r — - z „ u ,i 35,5A 254 Bay Rd - Queens bury,NY 12804- Phone:318-793-7444- Fax:518-793-70811- Emaih hih@hihlic.com .Fp;E:4 HAANEN ENGINEERING Job No 16 o SS sheet No. b of 7- Subject: LH/4 'Us-6 c C oe c By 115 Cir Date 5)z4 )►� (III) i ri d Loma.. Cea cuto. -i av1 op C S rnr1 Piers ?roc ed+kr+t; . ASCE- G.4.1) Simp.iPiecl desjy. wind prErsure la Q ?► k-Lt ' x P.530 A Acl.;ustrn - Pekcb'7Y fer ;Pt he;ylnit> a exr3suat Nei" ~artof heicpk 30►-0" g.xposes. Co.teocrwz A 43. ' rr� . TOP11Imp We. Fgtc ur & dePiwcd set dion 6. Sa ' • ti I,® b d'rvtp '9 tape. Po.c1 ps r eec-vfN 6. I• ® br30 7 Si rvIpliPied) des pr ivir , ; - = 6- 1-• t l• o r ,° 155rp OS So Hsi t8vD-1 fres swre, 14-1r4i t frers,wres. Gp4P) C PIP,) k 14. 4 piP tiff : a 1 psr E ' 1. 1 PsF 5: r sF 9• 9 IDsP 6.On : a 1t fsP r a -4.3e3f cP 11° sF (ft a oat PO . psF )01- 9 piF - soF -1, 1 psi CIA e 234 Bay Rd - Queeisbufy,NY 12804- Phone:518-793-7'.A`' a Fax:51b-793-7091- Eiflail:hih@hihllc.com HAANEN ENGINEERING Job No 16 035 Sheet No. 41 of T Subject: ?HA sr,rros By {•CSG? Date OS 14 4iS Since, kirri t Grp pri gtu"es & VeTh.c.4 until pre wi res a Yr. A eat %u 1.ps P Coo wo.-1-% ) Wt./eta PU0411 V, 1 S ps C®ns icy ntok. FIe>7ce) To ILJA base skeir age. LAIi1PNd p' 'ssur rhRuifkk 'flea V II di lion 16psf It hcf l` st Levafh i dov 4-0 F-rbaj —vur d •j-Col 1S-psp x 2 . P1-- x 1Ca P4- 4ri 3 it' s4j So kips —te 1 bc.s e S be, d4 e. w‘w1i p re-ssu roe i w 's i ale , s i ete, 20 x [1163P4- 13, kips 15 l'�s 254 Bay Rd - Queensbury,NY 12804- Phone:518-793-7444- Fax:518-793-7061- Email:hihPhjhIlc.com HAANEN ENGINEERING Job No b o5C Sheet No. S. of Subject: RI- ASS6 ci0k.S By H S Gr Date 0 5'Ali I'I (C) De-iG ,;we Stisrni c -to act 8e0 4S aa° ASCE v-os Si\e CadssiF;cohroh _ �t,�k'Auww . cYICG 5 Otss z b Ss = `W^ckppeol !►UGC 5 pow,* (tom pe.d� s pec}iuI ponse c.&cc..e - on fall en e.-/-e-7- cal' S 'for± pet-ion 51 _ bppec0 tee ) 6 pereevklr 1uulPe J SpeGW fae-sPertse deeeEtrult�w pot t e I M.G. ,° � : 6, ZS 4 6, s ®.o 3 Fo. t j .6 Fy = a2• 5 -r.Q . 6. 113 CM! - S a• I s� SAS Sa a St, DI I. 27:3 SPri a 12 FaV SOS e, a� S _ , S 0G o '8 Crabie, l!.6 -1) Seismic esi5 C eri a e• 254 Bay Ind - Ctueensbury,NY 12804- Phone:518-793-7444- Fan:518-793-7061- Email:hih@hihllc.com • HAANEN ENGINEERING Job No 16 0S/ Sheet No. A of 7` Subject: R- Assoc By /GSG• Date U5 Jo24 I Grenens4ResPorist Spec.(91 24. w Ct. e o. hI c So x : o. T Oo2x (3o) • 6,2si S•e6- n; • T x Spi = o. a3 X 0. 12 ' COI see. O.2.3- 4 T, - sp, e• 12g a O. Sec• e.+NF ,tom .ema. pr0cezi) titre, . C se11•6>1 12• ) Se isw,i c ease- shun r '� _- Cs• "i wh Cs Seis14c -re Woe(se to -ePP ;c ( vd VJ a 44 erPec. +ve seis-mic eig14- Cg SP d. - Oo ® z12, • (124) ( ) a G• 5 i ai Lis* NAThed wafis S•hesh.e wod S c1 pew►eis ra,pe4,1 ay JJ'env its th ,cc• CT ,-6-6,wie II.Z-0 254 Bay Rd - Queensbury,NY 12804- Phone:518-79S-7444- Fax:518-793-7061- Email:hih@hihUc.corn HAANEN ENGINEERING lob No 16 o SS sheet No. 7 of Subject: R FI 4 A-st6.1 By HSCst Date 5/62-14141 (R) Seismic mold load e P s Nere RO4 'Deed I01/1d iltrsFA 46P+- x 161 Pl- = IcI 21c1 pAotry 1 ups P 4cP+- x 10.r - size ÷ 20 % o1 .Sno )ud _ 0. 2 x 3.S•esP 10. x 16l CA- To 1 7 e23®1t 5vn To Se6ic cl•GGO. �. el-3 SIN � O� 0 4� X 23�ks � t ktp3 < fc4Pa. Hence, lii d Juusa3v6 9ove rns a es 254 Bay Rd - Queensbury,NY 12804- Phone:518-793-7444- Fax:518-793-7061- Email:hihPhihlic.com 2v ' L Envelope Leakage Test 3 3 v Testing Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address..- 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury NEINYORK 12804 Phone:5188573144 Email: tony@tocascioenergysolutions.com WWW.locascloenergysolutions.com Building Information: Customer Information: Project ID: Newcomb Street Apartments Name: Schermerhom Holdings Address: Newcomb Street Address: Queensbury. NY 12804 Geo-Tag Data: Latitude:43.301110 Longitude:-73.669553 Timestamp:2024-06-12 08:06:13 Measured Leakage: 0.21 CFM50Ift2 (Env. Area) Leakage Target: 0.30 CFM50/ft2(Env Area) Compliance with Leakage Target Pass Test ID: Mcluntairl"F Purpose of Test: NY IECC 15 Env Leakage Measured CFM50: 824.8(+1-0.60/0) Effective Leakage Area: 39.7 in2 Building Volume: 12,079.0 ft3 Enclosure Surface Area:3,940.0 ft2 Coefficient(C): 52,8(+1-4.8%) Exponent(n): 0.703 (+/-0.013) Correlation Coefficient: 0.99982 Test Standard: ASTM E779 (single mode) Test Mode: Depressurize Test Characteristics.. Pre Indoor Temp:67 °F Post Indoor Temp 67 DF Pre.Outdoor Temp:62°F Post Outdoor Temp:62 IT Altitude: 372.0 ft Time Average Period: 10 seconds Test Date and Time: 2024-06-12 0942:06 2000 - Depressurize — 600 -16 500 3 400 En 300 '5 200 CD 100 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure(Pa) Envelope Leakage Test Testing:Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury, NEW YORK 12804 Phone: 5188573144 Email: tony©10Cascieenergysolutions.com www.locasdoeriergysolutions.com Building information: Customer Information: Project ID: Newcomb Street Apartments Name: SCherrrierhom Holdings Address: Newcomb Street Address: Oueensbury, NY 12804 Geo-Tag:Data: Latitude:43.301110 Lengitude:-73.669553 Timestamp:2024-06-12 08:06:13 Measured Leakage; 0.22 CFM50/ft2(Env. Areal Leakage Target 0.30 CFM50/ft2(Env Area) Compliance-with,Leakage Target: Pass Test ID: Purpose of Test; NY IECC 15 nv.Leakage Measured-CFM50: 869.3 .3%) Effective Leakage Area 43.9 in2 Building Volume: 12079.0 ft3 Enclosure Surface Area 3;940.0 ft2 Coefficient(C): 69,9(t1-.9.8%) Exponent(n):0.684 (44-0.027) Correlation Coefficient: 0.99921 Test Standard ASTM E779 (single mode) Test Mode: Depressurize Test Characteristics: Pre Indoor Temp:.68 °F Post indoor Temp:6B°F Pre Outdoor Temp:62°F Post Outdoor Temp:62°F Altitude: 372.0 ft Time Average Period: 10 seconds Test Date and Time: 2024-06-12 0930:48 2000 o Depressurize P, 600 500 111) 400 F 300 -5 200 co 100 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure(Pa) 'r, I AfiCOMcheck Software Version 4.1.5.0 l Envelope Compliance Certificate Project Information IECEll iE Energy Code: 2018 IECC r • i Project Title: New 6 Unit Townhouse Apartment MAY 27 �022 z W Location: Glens Falls, New York , Uf fD = O Climate Zone: 6a TOWN QF UREA! i * AD • Project Type: New Construction BUILDING BBURY rn -e F a' Vertical Glazing/Wall Area: 12% "-D®DF-v Construction Site: Owner/Agent: Designer/Contractor: * g O Newcomb Street Schermerhorn Residential Holdings Ethan P. Hall CU 7 Queensbury, NY 12804 536 Bay Road Rucinski Hall Architecture _ O rQueensbury, NY 12804 627 Maple Ave um o -LE c 518-798-0674 Saratoga Springs, NY 12866 fD - PYrich@schermerhornconstruction.co 518-580-1905 e.41 n o m ephall@nycap.rr.com 5..m= n Additionat-E cieffi y akage(s) g O Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. 5 w co Building Area Floor Area 0 W 1-Multifamily: Residential 10621 cnON Envelope Assemblf€VIEWED FOR I EN E R G Y eeEPEylu pM p L IA N C E Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(e) Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1-Multifamily] 5213 38.0 0.0 0.027 0.021 Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1- 449 - 10.0 0.480 0.520 Multifamily](c) NORTH. Exterior Wall 3:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 1070 21.0 3.6 0.049 0.051 Door 17:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 18:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 19:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 20:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 21:Glass(>50%glazing):Nonmetal Frame,Perf.Specs.:Product 40 - - 0.290 0.430 ID Product Label,SHGC 0.33,[Bldg.Use 1 -Multifamily](b) Exterior Wall 4:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 384 21.0 3.6 0.049 0.051 EAST Exterior Wall 1:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 1160 21.0 3.6 0.049 0.051 Door 1:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 2:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 3:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 4:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 5:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 6:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 7:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 1 of 27 I a Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter Door 8:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 9:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 10:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 11:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 12:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Exterior Wall 2:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 848 21.0 3.6 0.049 0.051 Window 1:Vinyl Frame:Double Pane with Low-E,Pert.Specs.:Product 186 - - 0.290 0.360 ID Product Label,SHGC 0.33,[Bldg.Use 1 -Multifamily](b) SOU Exterior Wall 7:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 1070 21.0 3.6 0.049 0.051 Door 28:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 29:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 30:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 31:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 18 - - 0.300 0.370 Door 32:Glass(>50%glazing):Nonmetal Frame,Perf.Specs.:Product 40 - - 0.290 0.430 ID Product Label,SHGC 0.33,[Bldg.Use 1 -Multifamily](b) Exterior Wall 8:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 384 19.0 5.0 0.048 0.051 WEST Exterior Wall 5:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 1160 21.0 3.6 0.049 0.051 Window 2:Vinyl Frame:Double Pane with Low-E,Perf.Specs.:Product 217 - - 0.290 0.360 ID Product Label,SHGC 0.33,[Bldg.Use 1-Multifamily](b) Door 22:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 23:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 24:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 25:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Door 26:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 - - 0.300 0.370 Exterior Wall 6:Wood-Framed,16"o.c.,[Bldg.Use 1-Multifamily] 848 21.0 3.6 0.049 0.051 Window 3:Vinyl Frame:Double Pane with Low-E,Perf.Specs.:Product 310 - - 0.290 0.360 ID Product Label,SHGC 0.33,[Bldg.Use 1-Multifamily](b) (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope PASSES: Design 8% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Versi•- ,.1,5.0 d.to m.ly ith any applicable mandatory requirements listed in the Inspection Checklist. • '%-' " Ethan P. Hall-Architect , ` �, ;,.1.., IV° ¢,?)•®4' :, \ Name-Title Signatu 74.3/ ' N Ci\, Date kr * 'f'f'F,Iall A ljt1 \(\\:\ SL,.k .)i. 1:R41' t5 F ` erg Si L 41� n . J Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 2 of 27 AfiCOMcheck Software Version 4.1.5.0 i Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: New 6 Unit Townhouse Apartment Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Newcomb Street Schermerhorn Residential Holdings Ethan P. Hall Queensbury, NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs, NY 12866 rich@schermerhornconstruction.co 518-580-1905 m ephall@nycap.rr.com Additional Efficiency Package(s) Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Multifamily 10621 0.61 6500 Total Allowed Watts= 6500 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Multifamily Compact Fluorescent 1:Spiral 23W:Electronic: 1 102 32 3264 Total Proposed Watts= 3264 Interior Lighting PASSES: Design 50% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Versio 4.1.5.0 nd t m with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P.Hall-Architect �Y4= Name-Title Signature Date Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 3 of 27 .1 A( COMcheck Software Version 4.1.5.0 1 Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: New 6 Unit Townhouse Apartment Project Type: New Construction Exterior Lighting Zone 2(Residentially zoned area) Construction Site: Owner/Agent: Designer/Contractor: Newcomb Street Schermerhorn Residential Holdings Ethan P. Hall Queensbury, NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs, NY 12866 rich@schermerhornconstruction.co 518-580-1905 m ephall@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Pedestrian and vehicular entrances and exits 6 ft of door 14 Yes 84 Total Tradable Watts(a)= 84 Total Allowed Watts= 84 Total Allowed Supplemental Watts(b)= 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Main entry(6 ft of door width):Tradable Wattage Compact Fluorescent 1:Spiral 23W:Electronic: 1 12 32 384 Total Tradable Proposed Watts= 384 Exterior Lighting PASSES: Design 21% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Versi.• 4.1.5.0 and t comply with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P.Hall-Architect c kilo l h22 Name-Title Signat. Date Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 4 of 27 .1 COMcheck Software Version 4.1.5.0 Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: New 6 Unit Townhouse Apartment Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Newcomb Street Schermerhorn Residential Holdings Ethan P. Hall Queensbury, NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs, NY 12866 rich@schermerhornconstruction.co 518-580-1905 m ephall@nycap.rr.com Additional Efficiency Package(s) Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System 2(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System 3(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System 4(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 5 of 27 Quantity System Type&Description Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System 5(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System 6(Single Zone): Heating:1 each-Central Fumace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=0.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,450 CFM,0.8 motor nameplate hp,93.0 fan efficiency grade SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 Water Heater 1: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump • Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) 1 Water Heater 2: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) 1 Water Heater 3: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) 1 Water Heater 4: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) 1 Water Heater 5: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) 1 Water Heater 6: Electric Storage Water Heater,Capacity:40 gallons w/Circulation Pump Proposed Efficiency:91.00 SL,%/h(if>12 kW),Required Efficiency:0.98 SL,%/h(if>12 kW) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 6 of 27 . COMcheek Software Version 4.1.5.0 11 Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable envelope and document where exceptions to the standard are ❑Not Applicable claimed. C103.2 Plans,specifications, and/or ❑Complies [PR2]1 calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ENot Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications, and/or ❑Complies [PR3]1 calculations provide all information ❑Does Not with which compliance can be determined for the service water ❑Not Observable heating systems and equipment and ENot Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 Plans,specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting [Not Observable and electrical systems and equipment ENot Applicable and document where exceptions to the standard are claimed.Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C103.2 Plans,specifications,and/or ❑Complies [PR8]1 calculations provide all information ❑Does Not with which compliance can be determined for the exterior lighting ENot Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed.Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C402.4.1 The vertical fenestration area <=30 ❑Complies [PR10]1 percent of the gross above-grade wall ❑Does Not area. [Not Observable DNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 7 of 27 Il n Section # Plan Review Complies? Comments/Assumptions & Req.ID - C402.4.1 The skylight area <= 3 percent of the ❑Complies [PR11]1 gross roof area. ❑Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 8 of 27 • Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 Slab edge insulation installed per ❑Complies [F04]2 manufacturer's instructions. ❑Does Not ❑Not Observable { ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies [F06]1 damage,sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. ['Not Observable ❑Not Applicable C105 ;Installed slab-on-grade insulation type ❑Complies See the Envelope Assemblies table for values. [F03]2 and R-value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports. ['Not Observable ❑Not Applicable C402.2.4 'Slab edge insulation depth/length. ❑Complies See the Envelope Assemblies table for values. [FO7]2 !Slab insulation extending away from ❑Does Not building is covered by pavement or [Not Observable >= 10 inches of soil. ❑Not Applicable C403.12.2 Snow/ice melting system and freeze ❑Complies protection systems have sensors and ❑Does Not C403.12.3 controls configured to limit service for [F09]3 pavement temperature and outdoor ['Not Observable )temperature.future connection to ❑Not Applicable controls. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 9 of 27 Section # Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 1 Fenestration products rated in ❑Complies [FR12]2 accordance with NFRC. ❑Does Not [Not Observable ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies [FR13]i to performance labels or certificates ❑Does Not provided. [Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. EComplies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not [Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ❑Does Not 4 1 ❑Not Observable [FR8] ❑Not Applicable C402.4.4 U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.7 'Vestibules are installed on all building ❑Complies [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 10 of 27 • Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, `Heated water supply piping conforms ❑Complies C404.5.1, 'to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable DNot Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 !requirements. Refer to section details. ENot Observable [PL6]3 I ❑Not Applicable C404.5, ;Heated water supply piping conforms ❑Complies C404.5.1, Ito pipe length and volume ❑Does Not C404.5.2 !requirements.Refer to section details. ['Not Observable [PL6]3 I [Not Applicable C404.5, !Heated water supply piping conforms ❑Complies C404.5.1, ito pipe length and volume ❑Does Not C404.5.2 ;requirements. Refer to section details. [Not Observable [PL6]3 ❑Not Applicable C404.5, I Heated water supply piping conforms ❑Complies C404.5.1, ito pipe length and volume ❑Does Not C404.5.2 !requirements. Refer to section details. ❑Not Observable [PL6]3 ENot Applicable C404.5, !Heated water supply piping conforms ❑Complies C404.5.1, ;to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [Not Observable [PL6]3 i ❑Not Applicable C404.5, :Heated water supply piping conforms ❑Complies C404.5.1, !to pipe length and volume ❑Does Not C404.5.2 ;requirements. Refer to section details. ❑Not Observable [PL6]3 ❑Not Applicable C404.5, !Heated water supply piping conforms ❑Complies C404.5.1, ito pipe length and volume ElDoes Not C404.5.2 ;requirements. Refer to section details. ❑Not Observable [PL6]3 ❑Not Applicable C404.5, !Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ODoes Not C404.5.2 i requirements. Refer to section details. [PL6]3 i ENot Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, !to pipe length and volume ❑Does Not C404.5.2 I requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, !Heated water supply piping conforms ❑Complies C404.5.1, Ito pipe length and volume ❑Does Not C404.5.2 ;requirements. Refer to section details. [PL6]3 I ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 11 of 27 • Section Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, ;Heated water supply piping conforms ❑Complies C404.5.1, ;to pipe length and volume ❑Does Not C404.5.2 ;requirements. Refer to section details. [Not Observable [PL6]3 ONot Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. ❑Not Observable ONot Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. ['Not Observable ONot Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. ONot Observable ONot Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. ❑Not Observable ONot Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. ENot Observable ONot Applicable C404.6.1, Automatic time switches installed to DComplies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat trace. [Not Observable ONot Applicable C404.6.3 I Pumps that circulate water between a ❑Complies [PL7]3 I heater and storage tank have controls ❑Does Not ;that limit operation from startup to <= 5 minutes after end of heating ONot Observable ;cycle. ONot Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies [PL7]3 !heater and storage tank have controls ❑Does Not ;that limit operation from startup to <= 5 minutes after end of heating [Not Observable ;cycle. ONot Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 ;heater and storage tank have controls ❑Does Not ;that limit operation from startup to <=5 minutes after end of heating ['Not Observable (cycle. ONot Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies [PL7]3 i heater and storage tank have controls ❑Does Not ;that limit operation from startup to <=5 minutes after end of heating [Not Observable cycle. ONot Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies [PL7]3 ;heater and storage tank have controls ❑Does Not ;that limit operation from startup to <=5 minutes after end of heating ❑Not Observable ;cycle. ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 12 of 27 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.6.3 ;Pumps that circulate water between a DComplies [PL7]3 I heater and storage tank have controls ODoes Not ;that limit operation from startup to ❑Not Observable <=5 minutes after end of heating cycle. ❑Not Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies [PL7]3 !heater and storage tank have controls ❑Does Not ;that limit operation from startup to [Not Observable <=5 minutes after end of heating !cycle. ❑Not Applicable C404.6.3 ;Pumps that circulate water between a DComplies [PL7]3 heater and storage tank have controls ODoes Not that limit operation from startup to <=5 minutes after end of heating ❑Not Observable !cycle. ❑Not Applicable C404.6.3 ;Pumps that circulate water between a DComplies [PL7]3 I heater and storage tank have controls ODoes Not ;that limit operation from startup to <=5 minutes after end of heating ❑Not Observable cycle. ❑Not Applicable C404.6.3 ;Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ODoes Not <that limit operation from startup to <=5 minutes after end of heating ❑Not Observable I cycle. ❑Not Applicable C404.6.3 'Pumps that circulate water between a DComplies [PL7]3 theater heater and storage tank have controls ODoes Not ;that limit operation from startup to <= 5 minutes after end of heating ['Not Observable ;cycle. ❑Not Applicable C404.6.3 ;Pumps that circulate water between a i❑Complies [PL7]3 heater and storage tank have controls ODoes Not that limit operation from startup to [Not Observable <=5 minutes after end of heating cycle. ❑Not Applicable C404.7 Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump EDoes Not upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. C404.7 ;Demand recirculation water systems I❑Complies [PL8]3 have controls that start the pump ODoes Not ;upon receiving a signal from the ;action of a user of a fixture or ❑Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water ;piping to 104°F. • C404.7 Demand recirculation water systems DComplies [PL8]3 !have controls that start the pump ElDoes Not upon receiving a signal from the action of a user of a fixture or ['Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. C404.7 Demand recirculation water systems DComplies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 13 of 27 • Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.7 ;Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or Not Observable ;appliance and limits the temperature ❑Not Applicable ;of the water entering the cold-water ;piping to 104°F. C404.7 ;Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the ['Not Observable ,action of a user of a fixture or 'appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. C404.7 Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or Not Observable }appliance and limits the temperature ❑Not Applicable of the water entering the cold-water ;piping to 104°F. C404.7 'Demand recirculation water systems '❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. C404.7 Demand recirculation water systems ['Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the ❑Not Observable ;action of a user of a fixture or !appliance and limits the temperature ❑Not Applicable ;of the water entering the cold-water 'piping to 104°F. C404.7 ;Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water piping to 104°F. C404.7 ;Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not ;upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ❑Not Applicable of the water entering the cold-water ;piping to 104°F. C404.7 ;Demand recirculation water systems j❑Complies [PL8]3 ;have controls that start the pump ❑Does Not ;upon receiving a signal from the ;action of a user of a fixture or Not Observable }appliance and limits the temperature ❑Not Applicable ;of the water entering the cold-water ;piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 14 of 27 Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 ;Thermally ineffective panel surfaces of❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C402.5.5, ;Stair and elevator shaft vents have ❑Complies C403.2.4. imotorized dampers that automatically ❑Does Not 3 ;close. Refernece section C403.7.7 for [MEW ;operational details. ['Not Observable ❑Not Applicable C403.11.31HVAC piping insulation insulated in ❑Complies [ME61]z accordance with Table C403.11.3. ❑Does Not Insulation exposed to weather is protected from damage and is Pilot Observable provided with shielding from solar ENot Applicable radiation. C403.11.31HVAC piping insulation insulated in ❑Complies [ME61]z i accordance with Table C403.11.3. ❑Does Not Insulation exposed to weather is 1 protected from damage and is :Not Observable provided with shielding from solar ❑Not Applicable radiation. C403.11.31HVAC piping insulation insulated in ❑Complies [ME61]2 i accordance with Table C403.11.3. ❑Does Not !Insulation exposed to weather is ['Not Observable protected from damage and is 1 provided with shielding from solar ❑Not Applicable ;radiation. C403.11.31HVAC piping insulation insulated in EComplies [ME61]z ,accordance with Table C403.11.3. ❑Does Not {Insulation exposed to weather is ❑Not Observable protected from damage and is provided with shielding from solar ❑Not Applicable radiation. C403.11.31HVAC piping insulation insulated in ❑Complies [ME61]z ;accordance with Table C403.11.3. ❑Does Not Insulation exposed to weather is 1 protected from damage and is [Not Observable provided with shielding from solar ❑Not Applicable radiation. C403.11.31HVAC piping insulation insulated in ❑Complies [ME61]2 accordance with Table C403.11.3. ❑Does Not Insulation exposed to weather is ;protected from damage and is [Not Observable l provided with shielding from solar ❑Not Applicable radiation. C403.8.4 Motors for fans that are not less than ❑Complies [ME142]2 ;1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or have a minimum motor efficiency of ❑Not Observable 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. C403.8.4 'Motors for fans that are not less than ❑Complies [ME142]2 1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or 1 have a minimum motor efficiency of :Not Observable 70 percent.These motors have the ❑Not Applicable I means to adjust motor speed. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 15 of 27 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.8.4 1 Motors for fans that are not less than ❑Complies [ME142]2 1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or ❑Not Observable have a minimum motor efficiency of 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. C403.8.4 'Motors for fans that are not less than ❑Complies [ME142]2 1 1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or have a minimum motor efficiency of ElNot Observable 70 percent.These motors have the ❑Not Applicable E means to adjust motor speed. C403.8.4 I Motors for fans that are not less than ❑Complies [ME142]2 11/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or 1have a minimum motor efficiency of ❑Not Observable 70 percent.These motors have the ❑Not Applicable I means to adjust motor speed. C403.8.4 Motors for fans that are not less than ❑Complies [ME142]2 1 1/12 hp and less than 1 hp are ❑Does Not electronically commutated motors or :Not Observable l have a minimum motor efficiency of 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. C403.8.5 Each DX cooling system >65 kBtu ❑Complies [ME143]2 !and chiller water/evaporative cooling ❑Does Not system with fans> 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.8.5 (Each DX cooling system >65 kBtu ❑Complies [ME143]2 and chiller water/evaporative cooling ❑Does Not system with fans> 1/4 hp are designed to vary the indoor fan airflow ['Not Observable as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.8.5 I Each DX cooling system> 65 kBtu ❑Complies [ME143]2 land chiller water/evaporative cooling ❑Does Not !system with fans> 1/4 hp are ;designed to vary the indoor fan airflow [Not Observable 'as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.8.5 lEach DX cooling system> 65 kBtu ❑Complies [ME143]2 and chiller water/evaporative cooling ElDoes Not system with fans> 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.8.5 i Each DX cooling system> 65 kBtu ❑Complies [ME143]2 s and chiller water/evaporative cooling ❑Does Not ;system with fans> 1/4 hp are ['Not Observable designed to vary the indoor fan airflow I as a function of load and comply with ❑Not Applicable detailed requirements of this section. C403.8.5 Each DX cooling system >65 kBtu ❑Complies [ME143]2 and chiller water/evaporative cooling ❑Does Not system with fans> 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with ❑Not Applicable detailed requirements of this section. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 16 of 27 • Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.12.1 1Systems that heat outside the building ❑Complies [ME71]2 envelope are radiant heat systems ❑Does Not ;controlled by an occupancy sensing ❑Not Observable ,device or timer switch. ❑Not Applicable C403.2.3 `HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]z ❑Does Not [Not Observable ❑Not Applicable C403.2.2 Natural or mechanical ventilation is ❑Complies [ME59]1 provided in accordance with ❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ['Not Observable capability to reduce outdoor air supply ❑Not Applicable to minimum per IMC Chapter 4. C403.7.1 Demand control ventilation provided ❑Complies [ME59]1 for spaces>500 ft2 and >25 ❑Does Not people/1000 ft2 occupant density and served by systems with air side ENot Observable economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.7.2 Enclosed parking garage ventilation ❑Complies [ME115]3 has automatic contaminant detection ❑Does Not and capacity to stage or modulate !fans to 50%or less of design capacity. Not Observable 1 ENot Applicable C403.7.6 HVAC systems serving guestrooms in ❑Complies [ME141]3 Group R-1 buildings with> 50 ❑Does Not guestrooms: Each guestroom is provided with controls that ['Not Observable {automatically manage temperature ENot Applicable isetpoint and ventilation (see sections 1C403.7.6.1 and C403.7.6.2). C403.7.4 Exhaust air energy recovery on '❑Complies [ME57]1 systems meeting Table C403.7.4(1) ❑Does Not and C403.7.4(2). ❑Not Observable ❑Not Applicable C403.7.5 Kitchen exhaust systems comply with ❑Complies [ME116]3 !replacement air and conditioned ❑Does Not ;supply air limitations, and satisfy hood {rating requirements and maximum ENot Observable I exhaust rate criteria. ❑Not Applicable C403.11.1 j HVAC ducts and plenums insulated in ❑Complies {accordance with C403.11.1 and ❑Does Not C403.11.2 constructed in accordance with [ME60]z #C403.11.2,verification may need to ENot Observable {occur during Foundation Inspection. ENot Applicable C403.4.1. }Heating for vestibules and air curtains ❑Complies 4 1with integral heating include EDoes Not [ME63]z ;automatic controls that shut off the heating system when outdoor air ['Not Observable ;temperatures>45F.Vestibule ❑Not Applicable heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint<= 1 60F and cooling setpoint>=80F. C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not [Not Observable ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 17 of 27 • Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not [Not Observable ❑Not Applicable C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% ElDoes Not ❑Not Observable ❑Not Applicable C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not ❑Not Observable ❑Not Applicable C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% ❑Does Not ['Not Observable ❑Not Applicable C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50%>240 kBtu/h-25% EDoes Not ❑Not Observable ❑Not Applicable C408.2.2. ;Air outlets and zone terminal devices ❑Complies 1 'have means for air balancing. ❑Does Not [ME53]3 [Not Observable ❑Not Applicable C403.5, ;Refrigerated display cases,walk-in ❑Complies C403.5.1, Icoolers or walk-in freezers served by ❑Does Not C403.5.2 I remote compressors and remote [ME123]3 !condensers not located in a ❑Not Observable condensing unit, have fan-powered ElNot Applicable condensers that comply with Sections IC403.5.1 and refrigeration compressor ;systems that comply with C403.5.2.. Additional Comments/Assumptions: ]. High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 18 of 27 • Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. Spaces required to have light- ❑Complies 2 reduction controls have a manual ❑Does Not (EL22]1 control that allows the occupant to reduce the connected lighting load in Not Observable a reasonably uniform illumination ❑Not Applicable pattern >=50 percent. C405.2.1, Occupancy sensors installed in ❑Complies C405.2.1. classrooms/lecture/training rooms, ❑Does Not 1 conference/meeting/multipurpose [EL18]1 rooms, copy/print rooms, ❑Not Observable lounges/breakrooms,enclosed offices, ❑Not Applicable open plan office areas, restrooms, storage rooms,locker rooms, warehouse storage areas, and other spaces<=300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies 2 warehouses: In warehouses,the ❑Does Not [EL19]1 lighting in aisleways and open areas is controlled with occupant sensors that Not Observable automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ❑Complies 3 open plan office areas: Occupant ❑Does Not [EL2O]1 sensor controls in open office spaces ❑Not Observable >= 300 sq.ft.have controls 1) ❑Not Applicable configured so that general lighting can pP be controlled separately in control zones with floor areas<=600 sq.ft. within the space, 2)automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space,3)are configured so that general lighting power in each control zone is reduced by>=80%of the full zone general lighting power within 20 minutes of all occupants leaving that control zone,and 4)are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, Each area not served by occupancy ❑Complies C405.2.2. sensors(per C405.2.1) have time- ❑Does Not 1, switch controls and functions detailed C405.2.2. in sections C405.2.2.1 and C405.2.2.2. ['Not Observable 2 ❑Not Applicable [EL21]2 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 19 of 27 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with ❑Complies C405.2.3. R individual controls that control the ❑Does Not 1, ;lights independent of general area ❑Not Observable C405.2.3. S lighting.See code section C405.2.3 ❑Not Applicable 2 Daylight-responsive controls for pP e [EL23)2 i applicable spaces,C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for ❑Complies [EL26]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies [EL27]1 allowed for special functions per the ['Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. ❑Not Applicable C405.2.5 Automatic lighting controls for exterior ❑Complies [EL28]no° lighting installed.Controls will be ❑Does Not daylight controlled,set based on business operation time-of-day,or ['Not Observable reduce connected lighting >30%. ❑Not Applicable C405.3 :Exit signs do not exceed 5 watts per ❑Complies [EL6]1 'face. ElDoes Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 20 of 27 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed only where the roof slope is<=3 in ❑Not Observable 12. ❑Not Applicable C402.2.1 Insulation installed on a suspended ❑Complies [IN20]i ceiling having ceiling tiles is not being ❑Does Not specified for roor/ceiling assemblies. Continuous insulation board installed ❑Not Observable in 2 or more layers with edge joints ❑Not Applicable offset between layers. C303.1 Building envelope insulation is labeled ❑Complies I[IN10]2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. ['Not Observable ❑Not Applicable C303.2 Above-grade wall insulation installed EComplies [IN7]1 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 I Exterior insulation is protected from ❑Complies [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ❑Not Observable 'Foundation Inspection. ❑Not Applicable C105 Installed above-grade wall insulation ❑Complies See the Envelope Assemblies table for values. [IN6]' type and R-value consistent with ❑Does Not insulation specifications reported in plans and COMcheck reports. ❑Not Observable ❑Not Applicable C402.2.3 I Installed floor insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN8]2 'value consistent with insulation EDoes Not specifications reported in plans and COMcheck reports. ❑Not Observable :Not Applicable C402.2.6 'Radiant panels and associated ❑Complies [IN18]3 ;components,designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are [Not Observable ;insulated with a minimum of R-3.5. ❑Not Applicable C105 Installed roof insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN2]1 value consistent with insulation ❑Does Not specifications reported in plans and COMcheck reports.For some ceiling ❑Not Observable systems,verification may need to ❑Not Applicable occur during Framing Inspection. C402.5.1. All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked,gasketed,weather stripped ['Not Observable or wrapped with moisture vapor- permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 ,Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 21 of 27 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, ;Furnished O&M instructions for ❑Complies C408.2.5. ;systems and equipment to the ❑Does Not 2 ;building owner or designated [FI17]3 ;representative. [Not Observable ❑Not Applicable C303.3, `Furnished O&M manuals for HVAC ❑Complies C408.2.5. !systems within 90 days of system ❑Does Not 3 ;acceptance. [F18]3 ; ❑Not Observable ❑Not Applicable C402.5 Building envelope contains a ❑Complies [FI55]1 continuous air barrier that has been ❑Does Not tested and deemed to limit air leakage ❑Not Observable <=0.40 cfm/ft2. ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [F137]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. [Not Observable ❑Not Applicable C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. ❑Not Observable ❑Not Applicable C403.2.2 HVAC systems and equipment ❑Complies [FI27]3 I capacity does not exceed calculated ❑Does Not Toads. [Not Observable ❑Not Applicable C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 I controlled by a thermostat control. ❑Does Not [FI47]3 ;Minimum one humidity control device ;per installed ❑Not Observable ;humidification/dehumidification ❑Not Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ❑Not Applicable ;system. C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 :controlled by a thermostat control. ❑Does Not • [FI47]3 ;Minimum one humidity control device ;per installed ['Not Observable humidification/dehumidification ❑Not Applicable ;system. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 22 of 27 • Section # Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 :controlled by a thermostat control. ❑Does Not [FI47]3 ;Minimum one humidity control device ;per installed ['Not Observable humidification/dehumidification ONot Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed [Not Observable ';humidification/dehumidification ❑Not Applicable system. C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 Icontrolled by a thermostat control. ❑Does Not [FI47]3 ;Minimum one humidity control device ;per installed ❑Not Observable humidification/dehumidification ❑Not Applicable I system. C403.4.1. ;Thermostatic controls have a 5 °F ❑Complies 2 deadband. ❑Does Not [FI38]3 ['Not Observable ❑Not Applicable C403.2.4. ;Temperature controls have setpoint ❑Complies 1.3 ;overlap restrictions. ❑Does Not [FI20]3 i ❑Not Observable ❑Not Applicable C403.2.4. ;Each zone equipped with setback ❑Complies 2 'controls using automatic time clock or ❑Does Not [FI39]3 programmable control system. ['Not Observable ❑Not Applicable C403.2.4. 'Automatic Controls:Setback to 55°F ❑Complies 2.1, (heat)and 85°F(cool); 7-day clock,2- EDoes Not C403.2.4. hour occupant override, 10-hour 2.2 backup [Not Observable [F140]3 ❑Not Applicable C403.2.4. {Systems include optimum start ❑Complies 2.3 Icontrols. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C403.2.4. ;Systems include optimum start ❑Complies 2.3 Icontrols. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C403.2.4. ;Systems include optimum start ❑Complies 2.3 }controls. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C403.2.4. ;Systems include optimum start ❑Complies 2.3 ;controls. ❑Does Not [FI41]3 I ❑Not Observable ❑Not Applicable C403.2.4. ;Systems include optimum start ❑Complies 2.3 controls. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 23 of 27 Section Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. 'Systems include optimum start ❑Complies 2.3 controls. ❑Does Not [FI41]3 ['Not Observable ❑Not Applicable C404.3 Heat traps installed on supply and ❑Complies [FI11]3 discharge piping of non-circulating ❑Does Not systems. [Not Observable ❑Not Applicable C404.3 ;Heat traps installed on supply and EComplies [FI11]3 discharge piping of non-circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable C404.3 ;Heat traps installed on supply and ❑Complies [FI11]3 'discharge piping of non-circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable C404.3 ;Heat traps installed on supply and ❑Complies [FI11]3 I discharge piping of non-circulating ❑Does Not systems. ['Not Observable ❑Not Applicable C404.3 Heat traps installed on supply and ❑Complies [FI11]3 !discharge piping of non-circulating ❑Does Not systems. ❑Not Observable { ❑Not Applicable C404.3 ;Heat traps installed on supply and ElComplies [FI11]3 discharge piping of non-circulating ❑Does Not ;systems. ['Not Observable ❑Not Applicable • C404.4 (All piping insulated in accordance with ❑Complies [Fi25]2 section details and Table C403.11.3. ❑Does Not ❑Not Observable ❑Not Applicable C404.4 All piping insulated in accordance with ❑Complies [FI25]z section details and Table C403.11.3. ❑Does Not ❑Not Observable ❑Not Applicable C404.4 (All piping insulated in accordance with ❑Complies [FI25]z section details and Table C403.11.3. ❑Does Not ['Not Observable ❑Not Applicable C404.4 f All piping insulated in accordance with ❑Complies [F125]2 section details and Table C403.11.3. ❑Does Not [Not Observable ❑Not Applicable C404. lies [Fl25]4 piping section details insulatedwith p and Table C403 11 3 ❑Do sNot ['Not Observable :Not Applicable C404.4 'All piping insulated in accordance with ❑Complies [FI25]2 section details and Table C403.11.3. EDoes Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 24 of 27 ' . G Section # Final Inspection Complies? Comments/Assumptions & Req.ID C404.6.1 ;Controls are installed that limit the ❑Complies [F112]3 l operation of a recirculation pump ❑Does Not ;installed to maintain temperature of a ;storage tank.System return pipe is a [Not Observable idedicated return pipe or a cold water ❑Not Applicable ;supply pipe. C404.6.1 Controls are installed that limit the ❑Complies [FI12]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a storage tank.System return pipe is a ❑Not Observable dedicated return pipe or a cold water ❑Not Applicable supply pipe. C404.6.1 Controls are installed that limit the ❑Complies [FI12]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a storage tank.System return pipe is a ❑Not Observable dedicated return pipe or a cold water ❑Not Applicable ;supply pipe. C404.6.1 Controls are installed that limit the ❑Complies [FI12]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a ;storage tank. System return pipe is a ❑Not Observable dedicated return pipe or a cold water ❑Not Applicable ;supply pipe. C404.6.1 ;Controls are installed that limit the ❑Complies [FI12]3 'operation of a recirculation pump ❑Does Not ;installed to maintain temperature of a ;storage tank.System return pipe is a [Not Observable (dedicated return pipe or a cold water ❑Not Applicable ;supply pipe. C404.6.1 ;Controls are installed that limit the ❑Complies [FI12]3 'operation of a recirculation pump ❑Does Not installed to maintain temperature of a ;storage tank.System return pipe is a ❑Not Observable dedicated return pipe or a cold water ❑Not Applicable ;supply pipe. C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans,demonstrating proposed watts ❑Not Observable are less than or equal to allowed ❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent EComplies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating proposed watts are less than or equal ['Not Observable to allowed watts. ❑Not Applicable C408.2.1 Commissioning plan developed by ❑Complies [FI28]1 registered design professional or ❑Does Not approved agency. :Not Observable ❑Not Applicable C408.2.3. HVAC equipment has been tested to ❑Complies 1 ensure proper operation. ❑Does Not [FI31]1 ❑Not Observable ENot Applicable C408.2.3. HVAC control systems have been ❑Complies 2 tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls. [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 25 of 27 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.4 Preliminary commissioning report ❑Complies [FI29]1 completed and certified by registered ❑Does Not design professional or approved agency. ❑Not Observable ❑Not Applicable C408.2.5. Furnished HVAC as-built drawings ❑Complies 1 :submitted within 90 days of system ❑Does Not [FI7]3 I acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies 1 I electric power systems within 90 days ElDoes Not [FI16]3 :of system acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies 3 balancing report is provided for HVAC ❑Does Not [FI43]1 systems. [Not Observable ElNot Applicable C408.2.5. Final commissioning report due to ❑Complies 4 building owner within 90 days of ❑Does Not [FI30]'i receipt of certificate of occupancy. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies [FI33]1 ensure proper calibration,adjustment, ❑Does Not programming,and operation. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 26 of 27 Project Title: New 6 Unit Townhouse Apartment Report date: 05/22/22 Data filename: Y:\Racicot Development\Newcomb Street Apartments\Racicot-6 plex.cck Page 27 of 27