ChecklistReport010-22-24 013202INSPECTION WORKSHEET
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number: 2024-0106 Case Module:
Application
Inspection Date:
October 22, 2024 Inspection Status:
Reinspect
Inspector:
Charles Dyer Inspection Type:
Framing
Job Address:
10 POLK DR
Lake George,NY 12845
Parcel Number:
239.12-2-35.1
Contact Type
Company Name
Name
Contractor
Abele Builders
Owner
Rockhurst LLC
Rockhurst LLC
Checklist Item
Status
Permit card visible from road
PASS
Building Inspector notes
Framing
Ice and water shield 24 inches from wall
partial only/east side 10/22/24 for remainder of ice&water barrier/approved
PASSN/O
Less than 4:12 pitch install double layer of ice and water shield
Attic Access 22 inch x 30 inch minimum with 30 inch head clearance
Crawl space 18 inches x 24 inches access, 1 sq. ft. per 150 sq. ft. vents
Jack Studs, headers and double jack studs 6' or greater
Garage portal framing
Truss Specification Provided on site
Bracing and bridging
Hurricane Clips and Uplift Screws all nail holes filled as per manufacturer
Jack Posts and Main Beams
Lag top plates and bottom plates of steel columns
Exterior sheeting nailed properly
Notches, Holes and Bearing Walls
Headroom 6 ft. 8 in.
Deck post beam connections must use hex head bolts
Joist hangers
Metal Strapping for Notches Top Plate
/
Charles Dyer
Code Enforcement Officer