AST-0539-2023 Office Use Only
'�� ACCESSORY STRUCTURE Permit#: I)ST' v53 ?-7-6z3
Town ofQuuee sn bury PE j RiaLf A I 73ermit Fee:$ 1-7 't 2-742 Bay Road,Queensbury,NY 12804 nvoice#: ut,3 cp
P:518-761-8256 www.queensbury.net AUG 30 2023
Flood Zone? Y Reviewed By:OAD
TOWN OF QUEENSBURY
11 BUILDING&CODES
Project Location: 2$ (w+�'L1.I ) n c Oute€4136Gt,rili,
Tax Map ID#: Subdivision Name:
PROJECT INFORMATION: 1�
TYPE: Residential ❑ Commercial, Proposed Use:
STRUCTURE:
El Boathouse(with or w/o sundeck) ❑ Canopy ❑ Carport ❑ Cell Tower Deck
❑ Detached Garage (>300 s.f.) ❑ Dock ❑ Gazebo ❑ Pavilion ❑ Pole Barn YPorch ❑ Ramp
❑ Shed (<300 s.f.) ❑ Solar Panels(w/o rafter upgrades) ❑ 3-Season Porch ❑ Other:
SQUARE FOOTAGE OF STRUCTURE:
1st floor:
god floor: see- $ r-7
Total square feet:
Brief description of scope of project:
AbDCTIDK)
H Art N Dot 251 x tet I Indm 4 at rMI Fe2 Foe_ 'Ri`r Dc 4111 'Fr
Be►b( tEt ea) .sc,cze Rx:oM zo'A = 17 o 5t?.F t:
III X ID( 110 Sze-
ONE St De of CokattJUbJS tb c tL- t S ATE tt -RD o-VolZE, Z2E ST rs+J
PtE;fLS 14S 'D2AtZliUIG 5> StDL
Accessory Structure Application Revised January 2021
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$ Cli SVC)
2. Are there any structures not shown on the plot plan? DYES 'NO Explain:
3. Are there any easements on the property? ❑ YES )749 NO
DECLARATION:
1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. I certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
VOteL / 602EENA CccistesS
PRINT NAME:
SIGNATURE: "i /Ja &a %e DATE: OS q i17Z3
Accessory Structure Application Revised January 2021
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Sekeeak C66 f5 4 KITH Ui?C L
Mailing Address, C/S/Z: 29T(..tki(( aocad Q sb NY DY
Cell Phone: 51%1,21 aft i(61$33g(42Land Line:
Email: Se,r acOo#s tla t00.cc / ge,",volt C C 6
141
• Primary Owner(s):
Name(s):
Mailing Address, C/S/Z: 6Opl2 as &ODA.
Cell Phone: Land Line:
Email: !oi4(p-2Co'S- (97 7
❑ Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contractor Name(s): C.f'l.(Aghnaditer ac5(65 (,LC
Contractor Trade: at/ 6e
U
Mailing Address, C/S/Z: ( rAN p�� c� eflrcv4-t La-t. 1'41 c
Cell Phone: Land Line: (02 to +
Email:
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Engineer(s):
Business Name:
Contact Name(s):
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
Contact Person for any questions regarding this project:
Cell Phone: Land Line: r\` k\---
Email: )
Accessory Structure Application Revised January 2021
a
(3) PT2X10 BEAMS
NOTES �yyyp/�
FILM IS 1.100, EXCEPT AS NOTED.
BEAM MEMBER. SIZE do SPACING AS INDICATED.
FIELD VERRIIFIICA�TIIONNpOFF DIIMpE�N�SIIONSTNEECpESSAARpY.pp�� g �p g� 2 p�
2 ' 10 MATOFI Wff Ads EQUIVALENT IN%UMBER TO I BEAM BEINd4SUPPORTED.
C#WNS'&A ACT WITH CONCRE7EAOR �Y TO PRESSURE
BEARING LENGTHS AMING CONNECTORS TO BE SIZED TO DEVELOP FULL
SMTIAIINE DDECCKO- M46E77 SQUARE FEET
BRIDGE DECK TO SCREEN ROOM - 120 SQUARE FEET
SCREENROOM 10'-0" X 11'-0" - 110 SQUARE FEET
SEE SHEET 4 FOR WINDOW SCHEDULE
BATH
C
w.i.a
ED]
%
WIG
C
(2) PT2X10 BEAMS
alEAMAN
III
FILE DOPY
1 11
25'-0"
_ 55' 1 0" -
14 1
n
c
,...r:4V
Q RNX Of
307.-1-20 AST-0539-2023
Coombes, Sereena & Keith Vogel
28 Tuthill Rd
Deck 697 s.f.
=FILEPY
TOWN OF QUEENSBURY
BUILDiig
G D PT.
Revie
Date:
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
Based on our limited examination, compliance
with our comments shall not be construes' as
indicating the plans and specifications are in
full compliance with the Building Codes of
New York State.
LcUx t1.UU1L1v11 LU the Residence of
Sereena Coombes
28 Tuthill Road
Queensbury New York 12804
SHEET 1 OF 4 MAIN FLOOR PLAN
6$-0"
CONTINUOUS FLASHING
FOR RAILING DETAILS
SEE SHEET 4 ,
TIMBERTECH AZEK
SILVER MAPLE
5-1/4"X1" DECKING
(2) 3/4" BOLTS THRU
/ WITH WASHERS/NUTS
PT2X8 JOISTS
JOIST HANGER
NOTCH POST
J
CONTINUOUS FLASHING
(2) PT2X10 BEAMS
Q
PT2X10 HEADER
x
TIMBERTECH AZEK
LAG TO WALL
SILVER MAPLE
PT6X6 POST
p
5-1/4"X1" DECKING
W
a
a
Q
PT2X8 JOISTS
JOIST HANGER :
POST ANCHOR
GRADE
6" MINIMUM ABOVE GRADE
(2) 1/2" BOLTS THRU
NOTCH POST
o WITH WASHERS/NUTS
w
I
Q
PT2X8 HEADER
ANCHOR BOLT
..
C9
LAG TO WALL (2) PT2X8 BEAMS
!.
3
PT6X6 POST
Q
w
8" DIAMETER
•'':,
`•
aD
0
CONCRETE POST
a
a
Q
BELL BOTTOM —4111.
•'
of
OF PIER TYP.
v
POST ANCHOR
GRADE
ANCHOR BOLT
6" MINIMUM ABOVE GRADE
w
w '
O
8" DIAMETER
.' ,
CONCRETE POST
'^
O
:•
m
BELL BOTTOM
OF PIER TYP.
►•
A
o
SECTION C-C
JOISTS CENTERS JOIST
DATA-
PT2X8 1'-4" 5'-
SPAN BEAMS SPACING SPAN POSTS
w
SPACING
SECTION D-D
DECK D DATA
JOISTS
CENTERS
JOIST SPAN
I BEAMS
SPACING
SPAN
POSTS
SPACING
PT2X8
1'-0"1
10'-0"
10'-0"
10'-0"
PT6X6
10'-0"
SCREEN ROOM ABOVE THIS PORTION OF DECK
.r
a
Deck Addition to the Residence of
Sereena Coombes
2 � Tuthill Road
Queensb'Ar, New York 12804
SHEET, 2 OF 4 DETAILS
6" MINIMUM
ABOVE GRADE
W
0.
W
m
z
0
Z],
I SPAC�q
JOISTS I CENTERS JOIST SPAN BEAMS I SPACING SPAN POSTS
(2) 3/4" BOLTS THRU
WITH WASHERS/NUTS
H POST
F2X10 BEAMS
;POST
OR BOLT
METER CONCRETE
0
PT2X8 JOISTS
8" SPACING FOR HOT
TUB
TIMBERTECH AZEK
SILVER MAPLE
5-1/4"X1" DECKING
PT2X10 HEADER ON
HOUSE
(2) PT2X10 BEAMS
14
SECTION A -A
DECK A DATA
JOISTS
CENTERS
JOIST SPAN
BEAMS
I SPACING
I SPAN
POSTS
SPACING
PT 2X8
0'-8"
1 10'-0"
1 (Z) F I ZAIU
1 101-01,
1 9'-0" 1
PT6X6
1 9'-0"
HOT TUB ABOVE THIS PORTION OF DECK
Deck Addition to the Residence of
ereena oom es
28 Tuthill Road
Queensbury New York 12804
. SHEET 3 OF 4 DETAILS
z
o -555'
0
WE«
BECK
397=1-19
307.4-21
-475'
307:1-26
1-480'
PLOT PLAN
Sereena Coombes
28 Tuthill Road
Queensbury, NY 12804
based on Wayne Raymond survey (1987)